首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An accurate LC method was developed and validated for simultaneous determination of irinotecan (CPT-11) and its active metabolite SN-38 in rat plasma. Plasma samples were pretreated with 0.4 g mL?1 sodium dodecyl sulfate to inactive the carboxylesterase and avoid the conversion of CPT-11 to SN-38. Chromatographic separation was achieved on a Diamaonsil C18 column using acetonitrile–50 mM phosphate buffered solution (30:70, v/v) at pH 4.0 as the mobile phase with the flow rate of 1 mL min?1. The linear quantitation ranges for CPT-11 and SN-38 were 5.05–3,030 and 3.15–315 ng mL?1 with r 2 > 0.99, respectively. The lower limit of quantification (LLOQ) was 2.33 ng mL?1 for CPT-11 and 0.26 ng mL?1 for SN-38 with intra- and inter-day relative standard deviation of <12% and the accuracy values of >90%. The method was proved to be accurate and sensitive enough and was successfully applied to a pharmacokinetic study of CPT-11 in rats.  相似文献   

2.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

3.
A reversed-phase LC method has been developed for quantitative analysis of lutein in rat plasma and applied to a study of the pharmacokinetics of lutein in rats. From a variety of compounds and solvents tested, astaxanthin was selected as the internal standard. n-Hexane was found to be the best solvent for extracting lutein from plasma. LC analysis of the extracts was performed on a C18 column equipped with a guard pre-column. Linearity was good (r > 0.99) over the range 10–100 ng mL?1. Recovery from plasma was 82.7–92.9% the intra-day and inter-day precision were always better than 3%. The limits of detection (LOD) and quantification (LOQ) were 2.5 and 8.3 ng mL?1, respectively. The LC method was used to quantify lutein and zeaxanthin in rat plasma in a 36-h pharmacokinetic study in which experimental rats received a single oral dose of lutein (20 mg kg?1). The results are presented.  相似文献   

4.
A rapid LC method with UV detection was developed for the quantification of carboxylic acid metabolite of clopidogrel in human plasma. Following a simple protein precipitation using a mixture of methanolic solution of ZnSO4, the analyte and commercially available internal standard were separated using a mobile phase of water–acetonitril (85:15, v/v) adjusted to pH 3.5 on a Chromolith C18 column at a flow rate of 2.5 mL min?1 with a total retention time of 4 min. Linearity was verified over the range of 20–3,000 ng mL?1 where the LOQ was 20 ng mL?1. This method was applied in a pharmacokinetic study.  相似文献   

5.
A simple, rapid, sensitive and reliable liquid chromatography–electrospray ionization mass spectrometry method for the quantification of imperatorin in rat plasma after oral administration and total furocoumarins of Radix Angelica dahuricae has been established. The plasma samples were deproteinized by adding internal standard (IS) osthole solution, which was prepared by acetonitrile. The analysis was performed on a Shim-pack C18 column (150 × 2.0 mm i.d., 5 μm) using acetonitrile and 0.5% formic acid solution (70:30, v/v) as a mobile phase. The detection was performed on a quadrupole mass spectrometer detector with an ESI interface operated in the selected ion monitoring mode. The linear quantification range of the method was 2–4000 ng mL?1 in rat plasma with a correlation coefficient greater than 0.99, the limit of detection (LOD) was 0.5 ng mL?1 and the lower limit of quantification (LLOQ) 2 ng mL?1. The intra- and inter-day relative standard deviations (RSD) were less than 2.5 and 3.5%, respectively. The recoveries were above 90%. The validated method was successfully applied to a pharmacokinetic study of imperatorin in rats after oral administration and total furocoumarins of Radix Angelica dahuricae.  相似文献   

6.
A sensitive and specific LC–MS-MS method is described for the simultaneous quantification of risperidone and 9-hydroxyrisperidone in human plasma. After extraction with tert-butyl methyl ether, plasma samples were separated on an Atlantis HILIC Silica C18 column (4.6 × 150 mm, 5 μm)with a mobile phase of ammonium formate buffer (10 mM, pH 4.0)/acetonitrile (40/60, v/v). Detection was by MS-MS. The method was fully validated according to the accuracy profile theory. It is based on β-expectation tolerance interval for the total measurement error which includes trueness and intermediate precision. The measurement uncertainty derived from β-expectation tolerance interval was estimated at each of the validation standards. The linearity fitted well over the range of 0.11–26.75 ng mL?1 for risperidone with an LLOQ of 0.11 ng mL?1, and for 9-hydroxyrisperidone, at a range of 0.15–37.8 ng mL?1 with an LLOQ of 0.15 ng mL?1. The intra- and inter-batch precision of risperidone were <5.71 and 8.22%, respectively. For 9-hydroxyrisperidone, the data were 5.78 and 6.48%. The recoveries were 88.78% (risperidone) and 70.35% (9-hydroxyrisperidone). The developed method was applied to a pharmacokinetic study of risperidone.  相似文献   

7.
A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min?1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL?1 for wogonin and 10.8–271 ng mL?1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL?1 for wogonin and 10.8 ng mL?1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.  相似文献   

8.
A new LC method has been developed and validated for the direct determination of bupropion and its main metabolite, hydroxybupropion in human plasma. Plasma samples were analyzed after a simple, one step protein precipitation with trichloroacetic acid using a C8 column and mobile phase, consisting of methanol/acetonitrile/phosphate buffer (10 mM, pH 3.0) (40:10:50, v/v/v) and 20 mM 1-heptane sulfonic acid sodium salt with carbamazepine as the internal standard. UV detection was performed at 214 and 254 nm. The method was validated over the concentration range of 60–2,400 and 150–4,700 ng mL?1 for bupropion and hydroxybupropion, respectively. The intra- and inter-day assay variability was less than 15% for the two analytes. Limit of detection values were 24.8 and 63.4 ng mL?1 for bupropion and hydroxybupropion, respectively. The method developed was applied to quantification of bupropion and hydroxybupropion in human plasma.  相似文献   

9.
A rapid and sensitive LC–MS–MS method was developed and validated for the determination of asiaticoside in rat plasma. Asiaticoside was extracted by protein precipitation with acetonitrile, and separated on a C18 column. The total analytical time was relatively short (4 min), and the limit of quantification was 38 ng mL?1 using 100 μL of rat plasma. Asiaticoside and the internal standard (felodipine) were monitored in the multi-reaction-monitoring mode as follows: m/z 957.4 → 469.3 and m/z 382.2 → 145.1, respectively. Calibration was linear over a concentration range from 38 to 7,600 ng mL?1, and the correlation coefficient was greater than 0.998. The recoveries of asiaticoside from plasma were better than 85%, and RSDs of inter-day and intra-day assays were below 10.1%. The method is sensitive and specific, and suitable for pharmacokinetic studies of asiaticoside in rats.  相似文献   

10.
A sensitive and selective analytical method for the quantification of pregabalin, sildenafil and the active desmethyl metabolite of sildenafil (UK-103320) has been developed. The method can simultaneously quantify the three analytes within the expected in vivo concentration ranges using 50 ??L of rat plasma. It utilises solid-phase extraction followed by high performance liquid chromatography coupled with tandem mass spectrometry. Quantitation in rat plasma demonstrated good accuracy and precision over the following dynamic ranges for each analyte: pregabalin (70?C10,000 ng mL?1), sildenafil (1?C2,000 ng mL?1) and UK-103320 (1?C2,000 ng mL?1). For each analyte, the following lower limits of quantitation were obtained: 70 ng mL?1 for pregabalin and 1 ng mL?1 for sildenafil and UK-103320, respectively. The method was successfully used to analyse plasma samples from rats when pregabalin and sildenafil were administered in combination.  相似文献   

11.
A sensitive LC–MS–MS method with electrospray ionization has been developed for determination of nikethamide in human plasma. After addition of atropine as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 mm × 2.1 mm, 5 μm particle, Agilent Zorbax SB-C18 column, with 45:55 (v/v) methanol–water containing 0.1% formic acid as mobile phase. LC–MS–MS was performed in multiple reaction monitoring mode using target fragment ions m/z 178.8 → 107.8 for nikethamide and m/z 289.9 → 123.8 for the internal standard. Calibration plots were linear over the range of 20.0–2,000 ng mL?1. The lower limit of quantification was 20.0 ng mL?1. Intra-day and inter-day precisions were better than 4.2 and 6.1%, respectively. Mean recovery of nikethamide from human plasma was in the range 65.3–71.1%.  相似文献   

12.
A simple, rapid and sensitive liquid chromatography–mass spectrometry (LC–MS) method was developed for the quantification of salidroside in rat plasma and the study of its pharmacokinetics after oral administration of 15 g kg?1 Rhodiola crenulata extract to Wistar rats. A 200 μL plasma sample was extracted by acetonitrile and performed on Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with the mobile phase of acetonitrile–water (11:89) within a run time of 8 min. The analyte was monitored with electrospray ionization (ESI) by selected ion monitoring (SIM) mode. The target ions were m/z 299.20 for salidroside and m/z 150.00 for internal standard (IS) paracetamol. A good linear relationship was obtained over the range of 100–20,000 ng mL?1 and the lower limit of quantification was 100 ng mL?1. The validated method was successfully applied for the pharmacokinetic study of salidroside in rat. After oral administration of Rhodiola crenulata extract, the main pharmacokinetic parameters T max, T 1/2, C max, AUC 0?t and AUC 0?∞ were 0.56 ± 0.21 h, 7.91 ± 4.42 h, 3,386 ± 2,138 ng mL?1, 16,146 ± 6,558 ng h mL?1 and 18,599 ± 6,529 ng h mL?1, respectively.  相似文献   

13.
A simple, sensitive and selective LC–MS–MS method has been developed for the simultaneous determination of acyclovir and valacyclovir in human plasma. Acyclovir and valacyclovir in plasma were concentrated by solid phase extraction and chromatographed on a C18 column using a mobile phase of 0.1% formic acid: methanol (30:70% v/v). The method was validated over a linear range of 47–10,255 and 5–1,075 ng mL?1 for acyclovir and valacyclovir respectively. The LOQs were 47.6 and 5.0 ng mL?1. The validated method was applied for the quantitation of acyclovir and valacyclovir from plasma samples in a pharmacokinetic study.  相似文献   

14.
A simple, rapid, and sensitive liquid chromatography–mass spectrometric (LC–MS) method was developed and validated for the determination of isoniazid in dog plasma. Plasma samples were deproteined with methanol and separated on a C18 column interfaced with a single quadrupole mass spectrometer, using 0.1% formic acid–acetonitrile (91:9 v/v) as mobile phase. Detection was performed by positive electrospray ionization with selected ion monitoring at m/z 138 for isoniazid and 152 for entecavir maleate internal standard. Linearity was obtained over the range of 25–5,000 ng mL?1, with a lower limit of quantification of 25 ng mL?1. The intra- and inter-day precision was less than 2.7% in terms of relative standard deviation. Accuracy, expressed as relative error, ranged from ?2.0 to 8.0%. Plasma samples were analysed within 5 min. The method was successfully applied to the evaluation of the pharmacokinetics of isoniazid in dog plasma.  相似文献   

15.
The purpose of this article was to develop a rapid and robust LC–MS–MS method for quantifying shikonin and deoxyshikonin simultaneously in rat plasma using emodin as internal standard. The LC system consisted of an Agilent ZORBAX SB-C18 (1.8 μm, 250 × 4.6 mm, 20 °C) column. Elution with an isocratic mobile phase consisted of methanol/10 mM ammonium acetate in water/acetonitrile containing 0.05% formic acid (45:10:45, v/v/v) at a flow rate of 0.8 mL min?1 yielded sharp, high-resolved peaks within 12 min. The lower limits of quantitation were 0.5 ng mL?1 for shikonin, and 8 ng mL?1 for deoxyshikonin. Correlation coefficient (r) values for the linear range of two analytes were greater than 0.99. Assay precision was <13% and accuracy was 87–99%. This newly developed method was used to the pharmacokinetic studies of the shikonin analogues in rats after intravenous administration (n = 4).  相似文献   

16.
A sensitive LC–MS–MS method with electrospray ionization has been developed for analysis of mirtazapine in rat plasma. After addition of diazepam as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 × 4.6 mm, 5 μm particle, ODS column with 84:16 (v/v) methanol–water containing 0.1% ammonium acetate and 0.01% glacial acetic acid as mobile phase. LC–MS–MS was performed in selected-ion-monitoring (SIM) mode using target fragment ions m/z 195.09 for mirtazapine and m/z 192.80 for the IS. Calibration plots were linear over the range of 0.516–618.8 ng mL?1. The lower limit of quantification was 0.516 ng mL?1. Intra-day and inter-day precision were better than 12.6 and 8.8%, respectively. Mean recovery of mirtazapine from plasma was in the range 87.41–90.06%; average recovery was 88.40% (RSD 3.95%). Significant gender differences between mirtazapine pharmacokinetic data were observed in this study.  相似文献   

17.
A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL?1 for ferulic acid and 1.740–348.0 ng·mL?1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL?1 for ferulic acid and 1.740 ng·mL?1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.  相似文献   

18.
For the first time we report a rapid and sensitive LC–MS–MS method for quantification of rotenone, deguelin, and rotenolone in human serum. The analytical procedure involves extraction with ethyl acetate without further clean-up. The active ingredients were separated on a C8 reversed-phase column by isocratic elution. Eleven simultaneous transitions of precursor ions were monitored. Excellent selectivity and sensitivity enables quantification and identification of low levels of rotenoids (LOD 2 ng mL?1, LOQ 5 ng mL?1) in human serum.  相似文献   

19.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry quantitative detection method, using amantadine as internal standard, was developed for the simultaneous analysis of paracetamol, pseudoephedrine and chlorpheniramine concentrations. Analytes were extracted from plasma samples by liquid–liquid extraction with n-hexane–dichloromethane–2-propanol (2:1:0.1, v/v), separated on a C18 reversed-phase column with 0.1% formic acid–methanol (40:60, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves for plasma were linear over the concentration range 10–10,000 ng mL?1 of paracetamol, 2–2,000 ng mL?1 of pseudoephedrine and 0.2–200 ng mL?1 of chlorpheniramine. The method has a lower limit of quantitation of 10 ng mL?1 for paracetamol, 2.0 ng mL?1 for pseudoephedrine and 0.2 ng mL?1 for chlorpheniramine. Recoveries, precision and accuracy results indicate that the method was reliable within the analytical range, and the use of the internal standard was very effective for reproducibility by LC-MS-MS. This method is feasible for the evaluation of pharmacokinetic profiles of a novel multicomponent sustained release formulation containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride and 2 mg of chlorpheniramine maleate. It is the first time the pharmacokinetic evaluation of a novel sustained-action formulation containing paracetamol, pseudoephedrine and chlorpheniramine has been elucidated in vivo using LC-MS-MS.  相似文献   

20.
《Analytical letters》2012,45(14):2157-2169
Abstract

A rapid, sensitive, and specific liquid chromatography–tandem mass spectrometric (HPLC-MS/MS) method has been developed for quantification of ferulic acid in rat plasma. The analyte and docetaxel (internal standard) were extracted from plasma samples with diethyl ether and analyzed on a C18 column. The chromatographic separation was achieved within 3.5 min by using acetonitrile-water as the mobile phase and the flow rate was 0.2 mL · min?1. The method was linear within the range of 0.5 ? 800 ng · mL?1. The lower limit of quantification (LLOQ) was 0.5 ng · mL?1. Finally, the method is successfully applied for the pharmacokinetic study of ferulic acid in rats following intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号