首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
《Electroanalysis》2018,30(3):402-414
A sensitive electrochemical immunosensor for Hepatitis B virus surface antigen (HBsAg) detection was fabricated based on hemin/G‐quadruplex interlaced onto Fe3O4‐AuNPs or hemin ‐amino‐reduced graphene oxide nanocomposite (H‐amino‐rGO‐Au). G‐quadruplex DNAzyme, which is composed of hemin and guanine‐rich nucleic acid, is an effective signal amplified tool for its outstanding peroxidase activity and Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites with quasi‐enzyme activity provide appropriate support for the immobilization of hemin/G‐quadruplex. The target protein was sandwiched between the primary antibody immobilized on the GO and secondary antibody immobilized on the Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites and glutaraldehyde was used as linking agent for the immobilization of primary antibody on the surface of GO. Both Fe3O4‐AuNPs and H‐amino‐rGO‐Au nanocomposite and also hemin/G‐quadruplex can cooperate the electrocatalytic reduction of H2O2 in the presence of methylene blue as mediator. The proposed immunosensor has a wide linear dynamic range of 0.1 pg/ml to 300 pg/ml with a detection limit of 60 fg/ml when Fe3O4‐AuNPs was used for immobilization of hemin/G‐quadruplex, while the dynamic range and DL were 0. 1–1000 pg/mL and 10 fg/mL, respectively in the presence of H‐amino‐rGO‐ Au nanocomposite as platform for immobilizing of hemin/G‐quadruplex. The proposed immunosensor was also used for analysis of HBsAg in spiked human serum samples with satisfactory results.  相似文献   

2.
《Electroanalysis》2017,29(9):2098-2105
An ultrasensitive electrochemiluminescence (ECL) immunosensor for the detection of tetrodotoxin (TTX) is proposed, which are composed of the branched poly‐(ethylenimine) (BPEI) functionalized graphene (BGNs)/Fe3O4‐Au magnetic capture probes and luminol‐capped gold nanocomposites (luminol‐AuNPs) as the signal tag. Herein, a typical sandwich immunecomplex was constructed on the glassy carbon electrode. The BGNs/Fe3O4‐Au hybrids could efficiently conjugate primary antibody via the Au−S chemical bonds or Au−N chemical bonds and rapidly separate under external magnetic field. The introduction of BPEI to GO could enhance the luminol‐ECL intensity. Meanwhile, the multifunctional nanocomposites have been proved with good water‐solubility, excellent electron transfer, outstanding stability, etc. The luminescent luminol‐AuNPs, a high efficient electrochemiluminescence marker, can be assembled on the second antibody, which can produce the ECL signal to achieve the determination of TTX. This proposed ECL immunosensor with a linear range from 0.01–100 ng/mL can be applied in the detection of TTX in real samples with satisfactory results.  相似文献   

3.
A renewable potentiometric immunosensor for detection of immunoglobulin G (IgG) has been developed by magnetic force attraction of Fe3O4 nanoparticles immobilized goat‐anti‐human IgG antibody. For preparing sensitive film of the sensor, cysteine was bonded on the nano‐Fe3O4 particles surface. The cysteine functionalized magnetic nanoparticles was attracted on a solid paraffin carbon paste electrode surface to covalently immobilize of anti‐immunoglobulin G (anti‐IgG) by employing a conventional glutaraldehyde‐crosslinking method. The immunosensor showed a specific response to human immunoglobulin G in the range of 0.1–1.2 ng/mL with a detection limit of 0.023 ng/mL. The immunosensor based on the magnetic nanoparticles was made easily by this method. It can be used expediently, renewed easily and low‐cost relatively. The renewable potentiometric immunosensor with better stability and higher sensitivity can be employed extensively in clinical diagnosis, monitoring of disease and environmental studies and etc.  相似文献   

4.
A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of α-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe3O4-Au nanoparticles, which was first employed to capture AFP antigens to form Fe3O4-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe3O4-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe3O4-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL−1 with a detection limit of 0.2 pg mL−1. The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the amplification of the signal tag, the immunosensor is highly sensitive, which can offer great promise for rapid, simple, selective and cost-effective detection of effective biomonitoring for clinical application.  相似文献   

5.
A novel electrochemical immunosensor based on a magnetic glassy carbon electrode (MGCE) was developed for the quantitative determination of human immunoglobulin G (IgG). The immunosensing interface was fabricated by initially depositing silver nanoparticles on the MGCE surface and then immobilizing anti‐human IgG antibodies via the magnetic force between MGCE and Fe3O4 nanoparticles. The antibodies were covalently bonded to the amine‐functionalized Fe3O4 nanoparticles. Under optimal conditions, the magnetism‐assisted immunosensor exhibited a wide linear range from 0.1 pg/mL to 1.0 µg/mL with the detection limit of 0.05 pg/mL. Furthermore, the immunosensor displayed the advantages of good reproducibility and satisfactory stability.  相似文献   

6.
A rapid and ultrasensitive electrochemiluminescence (ECL) competitive immunoassay based on CdSe quantum dots (QDs) and the shorter chain as possible (cysteamine and glutaraldehyde) has been designed for the detection of salbutamol (SAL). Cysteamine and glutaraldehyde made coating antigen immobilize well on the gold electrode surface through the reaction between functional groups, which brought about the simplicity of the immunosensor to some extent. Transmission electron microscopy image, dynamic light scattering, photoluminescence, ultraviolet‐visible absorption and electrochemical impedance spectra were used to characterize the prepared CdSe QDs and the cysteamine/glutaraldehyde/Ovalbumin‐SAL/anti‐SAL‐QDs immunosensor. In the air‐saturated PBS buffer containing 0.1 M K2S2O8 and 0.1 M KCl (pH 9.0), a strong ECL emission of QDs can be observed which depended linearly on the logarithm of the salbutamol concentration with a wide range from 0.05 ng mL?1 to 100 ng mL?1, and a detection limit of 0.0056 ng mL?1. The sensitivity, repeatability, and specificity of the ECL immunosensor have been evaluated. The sensor has been applied to real samples with satisfactory results. This work will open new ways of detecting food additive residue based on QDs ECL in immunoassays.  相似文献   

7.
Present work demonstrates the fabrication of new and facile sandwich‐type electrochemical immunosensor based on palladium nanoparticles (PdNPs), polyaniline (PANI) and fullerene‐C60 nanocomposite film modified glassy carbon electrode (PdNP@PANI‐C60/GCE) for ultrasensitive detection of Prostate‐specific antigen (PSA) biomarker. PdNP@PANI‐C60 was electrochemically synthesized on GCE and used as an electroactive substrate. PdNP@PANI‐C60 was characterized by scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Primary antibody anti‐PSA (Ab1) was covalently immobilized on PdNP@PANI‐C60/GCE using NHS/EDC linkers. In the presence of PSA antigen, horseradish peroxidase secondary antibody (HRP‐Ab2) was brought into the surface of the electrode, developing stable amplified signals of H2O2 reduction. Under the optimal conditions, a linear curve for determination of PSA at the proposed immunosensor was 1.6×10?4 ng.mL?1 to 38 ng.mL?1 with a limit of detection (LOD) of 1.95×10?5 ng.mL?1. The proposed immunosensor was successfully validated in serum and urine samples towards PSA detection with satisfactory and acceptable results.  相似文献   

8.
本文研制了一种用金胶壳聚糖仿生膜来同时固定四甲基联苯胺(TMB)和酶标抗体的新型电化学免疫传感器,用于检测血清肿瘤标志物前列腺特异性抗原(PSA)的含量。固定的TMB作为电子传递媒介体,在扫速小于45 mV/s时,电极表现为一个表面控制过程,而在扫速大于45 mV/s时则表现为一个扩散控制过程。将固定有酶标抗体和TMB的免疫传感器与待测PSA抗原一起培育,在该传感器上形成的免疫复合物通过TMB-H2O2-HRP电化学体系进行了测定。在优化实验条件下,PSA的线性检测范围为5-30 ng·mL-1,检测限为1.0 ng·mL-1。该PSA免疫传感器制备方法简单,成本低廉,具有较好的稳定性和重现性。  相似文献   

9.
Developing non‐noble‐metal electrocatalyst for non‐enzymatic H2O2 sensing is highly attractive. A facile, two‐step approach has been utilized for the synthesis of PBNCs/SnO2 QDs/RGO ternary nanocomposite. TEM, SEM, XPS, and XRD techniques were used to the characterize the structural and morphological properties of synthesized ternary nanocomposite. The synthesized ternary nanocomposite has been examined as an electrode material for the electrochemical detection of H2O2 using the Amperometry technique. Under optimum conditions, PBNCs/SnO2 QDs/RGO ternary nanocomposite performed very well in the electrocatalytic reduction of H2O2 with a linear dynamic range from 25–225 μM (R2=0.996) with a low detection limit of 71 nM (S/N=3). Compared to the recent literature, PBNCs/SnO2QDs/RGO ternary nanocomposite based modified electrode exhibit a wider linear dynamic range with a low detection limit. Furthermore, PBNCs/SnO2 QDs/RGO ternary nanocomposite based modified electrode showed an excellent anti‐interference ability against various common interfering agents. The practical applicability of this ternary nanocomposite based modified electrode was further extended to determine the H2O2 in tap water with acceptable recovery. The present performance of PBNCs/SnO2 QDs/RGO ternary nanocomposite material towards H2O2 sensing might widen its application for developing a new type of non‐noble metal‐based non‐enzymatic electrochemical biosensors.  相似文献   

10.
Bidentate chelation, meso‐2,3‐dimercaptosuccinic acid (DMSA), was used as a stabilizer for the synthesis of CdTe quantum dots (QDs). The bidentate chelate QDs, characterized with FT‐IR, PL, and UV/Vis spectroscopy; element analysis; and high‐resolution transmission electron microscope, exhibited surface traps due to the large surface/volume ratio of QD particle and the steric hindrance of the DMSA molecule. The unpassivated surface of the QDs produced a narrower band gap than the core and electrochemiluminescent (ECL) emission at relatively low cathodic potential. In air‐saturated pH 7.0 buffer, the QDs immobilized on electrode surface showed an intense ECL emission peak at ?0.85 V (vs. Ag/AgCl). H2O2 produced from electrochemical reduction of dissolved oxygen was demonstrated to be the co‐reactant, which avoided the need of strong oxidant as the co‐reactant and produced a sensitive analytical method for peroxidase‐related analytes. Using hydroquinone/horseradish peroxidase/H2O2 as a model system, a new, reagentless, phenolic, ECL biosensor for hydroquinone was constructed, based on the quenching effect of ECL emission of QDs by consumption of co‐reactant H2O2. The biosensor showed a linear range of 0.2–10 μM with acceptable stability and reproducibility. This work opens new avenues in the search for new ECL emitters with excellent analytical performance and makes QDs a more attractive alternative in biosensing.  相似文献   

11.
A signal‐enhanced label‐free electrochemical immunosensor was constructed by the employment of Prussian blue doped silica dioxide (PB‐SiO2) nanocomposite. At first, PB‐SiO2 nanocomposite which was produced by using a microemulsion method was used to obtain a nanostructural monolayer on a glassy carbon electrode (GCE) surface. Next amino‐functionalized interface were prepared by self‐assembling 3‐aminopropyltriethoxy silane (APTES) on the PB‐SiO2 nanoparticle surface. Then chitosan stabled gold nanoparticle (CS‐nanoAu) was subsequently attached, while the entire surface was finally loaded with neuron‐specific enolase antibody (anti‐NSE) via the adsorption of gold nanoparticle. The sensitivity of the proposed immunosensor has greatly improved as the PB‐SiO2 nanostructural sensing film provides plenty of active sites which might catalyze the reduction of H2O2. The immunosensor exhibited good linear behavior in the concentration range from 0.25–5.0 and 5.0–75 ng/mL for the quantitative analysis of neuron‐specific enolase (NSE), a putative serum marker of small‐cell lung carcinoma (SCLC), with a limit of detection of 0.08 ng/mL. The resulting NSE immunosensor showed high sensitivity and long‐term lifetime which can be attributed to the extremely high catalytic activity and biocompatibility of CS‐nanoAu/APTES/PB‐SiO2 nanostructural multilayers.  相似文献   

12.
Magnetic electrochemiluminescent Fe3O4/CdSe–CdS nanoparticle/polyelectrolyte nanostructures have been synthesized and used to fabricate an electrochemiluminescence (ECL) immunosensor for the detection of carcinoembryonic antigen (CEA). CEA is a protein used as a biomarker for several cancers; particularly, to monitor response to treatment in colon and rectal cancer patients. The nanocomposites can be easily separated and firmly attached to an electrode owing to their excellent magnetic properties. This represents a promising advantage for bioassay applications. More importantly, the nanostructures exhibit intense and stable ECL emissions in neutral solution, which makes them ideal for ECL immunosensing. The 3‐aminopropyltriethoxysilane (APS) polyelectrolyte shell on the nanostructure surface not only enhances the intensity and stability of the ECL signal, but also acts as a crosslinker for immunosensor fabrication. A CEA antibody immobilized onto a nanocomposite/APS/electrode with gold nanoparticles comprises the ECL immunosensor. The principle of ECL detection for CEA is based on a change in steric hindrance after immunoreaction, which leads to a decrease in ECL intensity. A wide detection range (0.064 pg ml?1–10 ng ml?1) and low detection limit (0.032 pg ml?1) are achieved. The immunosensor is highly sensitive and selective, and exhibits excellent stability and good reproducibility. It thus has great potential for clinical protein detection. In particular, this approach uses a novel class of bifunctional nanocomposites that display both intense ECL and excellent magnetism, which renders them suitable for a large range of bioassay applications.  相似文献   

13.
A novel amperometric immunosensor based on L ‐cysteine/nanosized Prussian blue bilayer films ({NPB/L ‐cys}2) and gold nanoparticles (nano‐Au) was fabricated for determination of human chorionic gonadotrophin (HCG). First, L ‐cys and NPB was self‐assembled by layer‐by‐layer (LBL) technology to form {NPB/L ‐cys}2 bilayer films on the gold electrode. Subsequently, nano‐Au layer was immobilized on the {NPB/L ‐cys}2 bilayer films by electrodepositing gold chloride tetrahydrate and then anti‐HCG was assembly on the nano‐Au layer. Finally hemoglobin (Hb) was employed to block sites against nonspecific binding. With the electrocatalytic ability of Hb and NPB for the reduction of H2O2, the current signal of the antigen‐antibody reaction was amplified and the enhanced sensitivity was achieved. In this study, the assembly process and performance of the immunosensor were characterized by cyclic voltammetry (CV) and the morphology was researched by scanning electron microscopy (SEM). The immunosensor performed a high sensitivity and a wide linear response to HCG in two ranges from 0.5 to 10 mIU/mL and from 10 to 200 mIU/mL with a relatively low detection limit of 0.2 mIU/mL at 3 times the background noise, as well as good stability and long‐term life.  相似文献   

14.
A new electrochemical sensor based on Fe3O4@SiO2‐PANI‐Au nanocomposite was fabricated for modification of glassy carbon electrode (Fe3O4@SiO2‐PANI‐Au GCE). The Fe3O4@SiO2‐PANI‐Au nanocomposite was characterized by TEM, FESEM‐EDS‐Mapping, XRD, and TGA methods. The Fe3O4@SiO2‐PANI‐Au GC electrode exhibited an acceptable sensitivity, fast electrochemical response, and good selectivity for determination of quercetin. Under optimal conditions, the linear range for quercetin concentrations using this sensor was 1.0×10?8 to 1.5×10?5 mol L?1, and the limit of detection was 3.8×10?9 mol L?1. The results illustrated that the offered sensor could be a possible alternative for the measurement of quercetin in food samples and biological fluids.  相似文献   

15.
In this paper, a novel, low-cost electrochemiluminescence (ECL) immunosensor using core–shell Fe3O4–Au magnetic nanoparticles (AuMNPs) as the carriers of the primary antibody of carbohydrate antigen 125 (CA125) was designed. Graphene sheet (GS) with property of good conductivity and large surface area was a captivating candidate to amplify ECL signal. We successively synthesized functionalized GS by loading large amounts of quantum dots (QDs) onto the poly (diallyldimethyl-ammonium chloride) (PDDA) coated graphene sheet (P-GS@QDs) via self-assembly electrostatic reactions, which were used to label secondary antibodies. The ECL immunosensors coupled with a microfluidic strategy exhibited a wide detection range (0.005–50 U mL−1) and a low detection limit (1.2 mU mL−1) with the help of an external magnetic field to gather immunosensors. The method was evaluated with clinical serum sample, receiving good correlation with results from commercially available analytical procedure.  相似文献   

16.
《Electroanalysis》2017,29(12):2832-2838
In this study, a bimetallic nanomaterial‐based electrochemical immunosensor was developed for the detection of carcinoembryonic antigen (CEA) and vascular endothelial growth factor (VEGF) cancer biomarkers at the same time. CEA and VEGF biomarkers are indicators for colon and breast cancers and stomach cancers, respectively. During the study, gold nanoparticle (AuNp), lead nanoparticle (PbNp), copper nanoparticle (CuNp) and magnetic gamma iron(III)oxide (γFe2O3 Np) were synthesized, characterized and used together for the first time in the structure of an electrochemical biosensor based on anti‐CEA and anti‐VEGF. For this purpose, Au SPE based sandwich immunosensor was fabricated by using labeled anti‐CEA (labeled with Pb+2) and labeled anti‐VEGF (labeled with Cu+2). As a result, CEA and VEGF biomarkers were detected following the oxidation peaks of label metals (Pb+2 and Cu+2) by using differential pulse voltammetry. After the experimental parameters were optimized, the linear range was found in the concentration range between 25 ng/mL and 600 ng/mL with the relative standard deviation (RSD) value of (n=3 for 600 ng/mL) 3.33 % and limit of detection (LOD) value of 4.31 ng/mL for CEA biomarker. On the other hand, the linear range was found in the concentration range between 0.2 ng/mL and 12.5 ng/mL with the RSD value of (n=3 for 12.5 ng/mL) 5.31 % and LOD value of 0.014 ng/mL for VEGF biomarker. Lastly, sample application studies for synthetic plasma sample and interference studies with dopamine, ascorbic acid, BSA, cysteine and IgG were carried out.  相似文献   

17.
In this work, a novel multiplex electrochemiluminescence (ECL) DNA sensor has been developed for determination of hepatitis B virus (HBV) and hepatitis C virus (HCV) based on multicolor CdTe quantum dots (CdTe QDs) and Au nanoparticles (Au NPs). The electrochemically synthesized graphene nanosheets (GNs) were selected as conducting bridge to anchor CdTe QDs551-capture DNAHBV and CdTe QDs607-capture DNAHCV on the glassy carbon electrode (GCE). Then, different concentrations of target DNAHBV and target DNAHCV were introduced to hybrid with complementary CdTe QDs-capture DNA. Au NPs-probe DNAHBV and Au NPs-probe DNAHCV were modified to the above composite film via hybrid with the unreacted complementary CdTe QDs-capture DNA. Au NPs could quench the electrochemiluminescence (ECL) intensity of CdTe QDs due to the inner filter effect. Therefore, the determination of target DNAHBV and target DNAHCV could be achieved by monitoring the ECL DNA sensor based on Au NPs-probe DNA/target DNA/CdTe QDs-capture DNA/GNs/GCE composite film. Under the optimum conditions, the ECL intensity of CdTe QDs551 and CdTe QDs607 and the concentration of target DNAHBV and target DNAHCV have good linear relationship in the range of 0.0005–0.5 nmol L−1 and 0.001–1.0 nmol L−1 respectively, and the limit of detection were 0.082 pmol L−1 and 0.34 pmol L−1 respectively (S/N = 3). The DNA sensor showed good sensitivity, selectivity, reproducibility and acceptable stability. The proposed DNA sensor has been employed for the determination of target DNAHBV and target DNAHCV in human serum samples with satisfactory results.  相似文献   

18.
Apurinic/apyrimidinic endonuclease 1 (APE-1), a kind of multifunctional protein widely-distributed in the body, plays an essential role in the DNA base excision repair and serves as multiple possible roles in the response of human cancer to radiotherapy and chemotherapy. In this work, an ultrasensitive solid-state electrochemiluminescence (ECL) immunosensor is designed to determine APE-1 based on the new Ru(bpy)32+/bi-arginine system. The bi-arginine (bi-Arg) is decorated on the Au nanoparticles functionalized magnetic Fe3O4/reduced graphene oxide (bi-Arg/Au@Fe3O4–rGO) according to the self-assembling and covalent cross-linking interaction to obtain the functionalized nanocomposite of bi-Arg/Au@Fe3O4–rGO. Herein, the bi-Arg/Au@Fe3O4–rGO plays not only an amplification label to enhance the ECL signal of Ru(bpy)32+ due to the coreactant of bi-Arg but also an ideal nanocarrier to load numerous secondary antibody. Based on sandwich-type immunoassay format, this proposed method offers a linear range of 1.0 fg mL−1–5.0 pg mL−1 and an estimated detection limit of 0.3 fg mL−1 for the APE-1. Moreover, the reagentless ECL immunosensor also exhibits high sensitivity, excellent selectivity and good stability, which has greatly potential development and application in clinical diagnostics, immunology and biomedical research.  相似文献   

19.
We design well‐defined metal‐semiconductor nanostructures using thiol‐functionalized CdTe quantum dots (QDs)/quantum rods (QRs) with bovine serum albumin (BSA) protein‐conjugated Au nanoparticles (NPs)/nanorods (NRs) in aqueous solution. The main focus of this article is to address the impacts of size and shape on the photophysical properties, including radiative and nonradiative decay processes and energy transfers, of Au‐CdTe hybrid nanostructures. The red shifting of the plasmonic band and the strong photoluminescence (PL) quenching reveal a strong interaction between plasmons and excitons in these Au‐CdTe hybrid nanostructures. The PL quenching of CdTe QDs varies from 40 to 86 % by changing the size and shape of the Au NPs. The radiative as well as the nonradiative decay rates of the CdTe QDs/QRs are found to be affected in the presence of both Au NPs and NRs. A significant change in the nonradiative decay rate from 4.72×106 to 3.92×1010 s?1 is obtained for Au NR‐conjugated CdTe QDs. It is seen that the sizes and shapes of the Au NPs have a pronounced effect on the distance‐dependent energy transfer. Such metal‐semiconductor hybrid nanostructures should have great potentials for nonlinear optical properties, photovoltaic devices, and chemical sensors.  相似文献   

20.
Anodic electrochemiluminescence (ECL) of 3‐mercaptopropionic acid (MPA)‐ capped CdTe/CdS core‐shell quantum dots (QDs) with tripropylamine (TPrA) as the co‐reactant were studied in aqueous (Tris buffer) solution for the first time. The results suggest that the oxidation of TPrA at a glassy carbon electrode (GCE) surface participated in the ECL of QDs, and the onset potential and the intensity of ECL of CdTe/CdS QDs were affected seriously by TPrA, as the co‐reactant, in Tris buffer solution. The onset potential of ECL in this new system was about +0.5 V (vs. Ag/AgCl) and the ECL intensity greatly enhanced when TPrA was present. Various influencing factors, such as the electrolyte, pH, QDs concentration, potential range and scan rates on the ECL were studied. Based on the selective quenching by Cu2+ to the light emission from CdTe/CdS QDs/TPrA system, a highly sensitive and selective method for the determination of Cu2+ was developed. At the optimal conditions, the relative ECL intensity, I0/I, was proportional to the concentration of Cu2+ from 14 nM to 0.21 μM with the detection limit of 6.1 nM based on the signal‐to‐noise ratio of 3. The possible ECL mechanism of QDs and the quenching mechanism of ECL were proposed.  相似文献   