1.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

2.
A collaborative study on the robustness and portability of a capillary electrophoresis‐mass spectrometry method for peptide mapping was performed by an international team, consisting of 13 independent laboratories from academia and industry. All participants used the same batch of samples, reagents and coated capillaries to run their assays, whereas they utilized the capillary electrophoresis‐mass spectrometry equipment available in their laboratories. The equipment used varied in model, type and instrument manufacturer. Furthermore, different types of sheath‐flow capillary electrophoresis–mass spectrometry interfaces were used. Migration time, peak height and peak area of ten representative target peptides of trypsin‐digested bovine serum albumin were determined by every laboratory on two consecutive days. The data were critically evaluated to identify outliers and final values for means, repeatability (precision within a laboratory) and reproducibility (precision between laboratories) were established. For relative migration time the repeatability was between 0.05 and 0.18% RSD and the reproducibility between 0.14 and 1.3% RSD. For relative peak area repeatability and reproducibility values obtained were 3–12 and 9–29% RSD, respectively. These results demonstrate that capillary electrophoresis‐mass spectrometry is robust enough to allow a method transfer across multiple laboratories and should promote a more widespread use of peptide mapping and other capillary electrophoresis‐mass spectrometry applications in biopharmaceutical analysis and related fields.  相似文献   

3.
A chiral capillary monolithic column for enantiomer separation in capillary electrochromatography was prepared by coating cellulose tris(3,5‐dimethylphenylcarbamate) on porous glycidyl methacrylate‐co‐ethylene dimethacrylate monolith in capillary format grafted with chains of [2(methacryloyloxy)ethyl] trimethylammonium chloride. The surface modification of the monolith by the photografting of [2(methacryloyloxy)ethyl] trimethylammonium chloride monomer as well as the coating conditions of cellulose tris(3,5‐dimethylphenylcarbamate) onto the grafted monolithic scaffold were optimized to obtain a stable and reproducible chiral stationary phase for capillary electrochromatography. The effect of organic modifier (acetonitrile) in aqueous mobile phase for the enantiomer separation by capillary electrochromatography was also investigated. Several pairs of enantiomers including acidic, neutral, and basic analytes were tested and most of them were partially or completely resolved under aqueous mobile phases. The prepared monolithic chiral stationary phases exhibited a good stability, repeatability, and column‐to‐column reproducibility, with relative standard deviations below 11% in the studied electrochromatographic parameters.  相似文献   

4.
Wei W  Ju H 《Electrophoresis》2005,26(3):586-592
A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.  相似文献   

5.
The first application of charged polymer‐protected gold nanoparticles (Au NPs) as semi‐permanent capillary coating in CE‐MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run‐to‐run and capillary‐to‐capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin‐related alkaloids was achieved on the PDDA‐protected Au NPs‐coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20°C, applied voltage ?20 kV, and capillary effective length 60.0 cm. CE‐MS analysis with run‐to‐run RSDs (n=5) of migration time in the range of 0.43–0.62% and RSDs (n=5) of peak area in the range of 1.49–4.68% was obtained. The established CE‐MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC‐MS and GC‐MS for illicit drug control.  相似文献   

6.
We present a novel easy‐to‐operate and efficient method to improve the separation efficiency in short‐capillary electrophoresis by introducing steady backflow to counterbalance electro‐osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run‐to‐run repeatability and capillary‐to‐capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure‐driven backflow to enhance separation efficiency in short‐capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples.  相似文献   

7.
A novel and simple coating method was developed by coating bovine serum albumin (BSA) onto the inner surface of a fused-silica capillary, to avoid the adsorption of analytes during CE. The advantage presented here was that the coating process is more simple, fast, stable, and reproducible. The coated capillary avoided the adsorption of analytes onto the inner surface of a fused-silica capillary and might be a promising candidate for separation of complex biological samples with further development. Meanwhile, the efficiencies of the coated capillary were evaluated by EOF, chromatographic peak shape, and theoretical plate number (N m?1) of RNase A. The optimal coating conditions were obtained from the results. The pH value of coating buffer PB was 4.2, the standing time was 12 h at 4 °C, and the coating concentration of BSA was 1.5 mg mL?1. The stability of the coating on the inner wall of the capillary and the reproducibility of the coated capillaries were good. The theoretical plate number values of RNase A were over 1.3 × 105 (N m?1) in the coated capillary. After successive electrophoresis for 48 h using the coated capillary, the RSD values of EOF and the theoretical plate number were 4.14 % and 9.14 %, respectively. In addition, the RSD values of EOF and the theoretical plate number (N m?1) in the coated capillaries were 13.19 % and 8.96 %, respectively. Finally, the coated capillary was successfully applied to separate the mixture of four basic proteins (RNase A, lysozyme, trypsin and myoglobin).  相似文献   

8.
[2‐(Methacryloyl)oxyethyl]trimethylammonium chloride was successfully polymerized by surface‐initiated atom transfer radical polymerization method on the inner surface of fused‐silica capillaries resulting in a covalently bound poly([2‐(methacryloyl)oxyethyl]trimethylammonium chloride) coating. The coated capillaries provided in capillary electrophoresis an excellent run‐to‐run repeatability, capillary‐to‐capillary and day‐to‐day reproducibility. The capillaries worked reliably over 1 month with EOF repeatability below 0.5%. The positively charged coated capillaries were successfully applied to the capillary electrophoretic separation of three standard proteins and five β‐blockers with the separation efficiencies ranging from 132 000 to 303 000 plates/m, and from 82 000 to 189 000 plates/m, respectively. In addition, challenging high‐ and low‐density lipoprotein particles could be separated. The hydrodynamic sizes of free polymer chains in buffers used in the capillary electrophoretic experiments were measured for the characterization of the coatings.  相似文献   

9.
A stable polyelectrolyte multilayer (PEM) coating was investigated for use in open-tubular capillary electrochromatography (o-CEC). In this approach, the PEM consisted of the cationic polymer of a quaternary ammonium salt, poly(diallyldimethylammonium chloride) and the anionic polymeric surfactant, poly(sodium undecylenic sulfate). Both the cationic and anionic polymers were physically adsorbed to the surface of a fused-silica capillary by use of a simple coating procedure. This procedure involved an alternate rinse of the positively and negatively charged polymers. The performance of the PEM coating as a dynamic stationary phase was evaluated by use of electrochromatographic experiments and showed good selectivity for both phenols and benzodiazepines. Reproducibility of the PEM coating was also evaluated by calculating the relative standard deviations (RSDs) of the electroosomotic flow (EOF). The run-to-run and capillary-to-capillary RSD values of the EOF were less than 1.5%. The endurance of the coating was more than 100 runs. The importance of the PEM coating was illustrated by comparing separations on a bare uncoated capillary with the coated capillary. In addition, the chromatographic performance using o-CEC and micellar electrokinetic chromatography (MEKC) was compared for the separation of benzodiazepines.  相似文献   

10.
We evaluated the potential of CE to analyse different isoforms of unphosphorylated recombinant tau protein and for separating one phosphorylated tau from the respective unphosphorylated protein. Different capillary coatings such as polyacrylamide, poly‐(ethylene oxide) and polybrene (PB) were evaluated to overcome the poor efficiencies obtained with fused‐silica capillary. Although peak asymmetry values were quite similar for the three investigated coatings, the peak efficiencies were 35‐fold and 5‐fold higher with PB coating than with polyacrylamide and poly(ethylene oxide) coatings, respectively. The recovery percentage (over 97%) was satisfactory and confirmed the efficacy of PB coating to limit the adsorption of tau protein to capillary walls. Moreover, PB coating produced higher repeatability for migration times (RSD values <1.2%) in comparison to the neutral coatings. The potential of PB‐modified capillary in producing high resolutive separations of one phosphorylated tau isoform from its unphosphorylated counterpart and of a mixture of phosphorylated and unphosphorylated tau peptides was demonstrated with 50 mM phosphate buffer pH 3.0. The separation of unphosphorylated tau isoform 352 (Tau‐352) from Tau‐352 phosphorylated in vitro by the mitogen‐activated protein kinase ERK2, was accomplished in less than 15 min.  相似文献   

11.
The aim of the present study is the CE performance evaluation for the separation of 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs. In particular, the separation of indoprofen, carprofen, ketoprofen, ibuprofen, and flurbiprofen was obtained by supporting the BGE either with SDS or an amino acid ester‐based ionic liquid (AAIL). The performance of these additives was evaluated by comparing migration times, efficiencies and %RSD values. The addition of the AAIL into the BGE provided baseline separation within 10 min, while in the case of SDS, the analytes eluted within 23 min. The optimum conditions involve a BGE of 100 mM Tris/10 mM sodium tetraboratedecahydrate (pH 8) and 40 mM l ‐alanine tert butyl ester lactate or 10 mM SDS and a temperature of 35°C for AAIL and 20°C for SDS. The run‐to‐run reproducibility was evaluated by computing the %RSD values of the EOF and the analyte peaks. When the AAIL was used, an excellent reproducibility was obtained, since all %RSD values were below 1.3%. On the contrary, the addition of SDS resulted in much higher RSD values (2.1–11.7%). The efficiency values of all analyte peaks were above 102 000 for l ‐AlaC4Lac, in comparison to SDS, which provided efficiency values between 47000 and 76000. Finally, in an attempt to study the synergistic effect of SDS and AAIL, both additives were added into the BGE at concentrations of 10 and 40 mM, respectively. The results were similar to the ones obtained when SDS was used as the sole additive.  相似文献   

12.
With unique 3‐D architecture, the application of core‐based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, Mw ≈? 5000 and CHPEI25, Mw ≈? 25 000) were physically adsorbed onto the inner surface of bare fused‐silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0–9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three‐fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) ? 2 was obtained. Effect of ionic strength, stability of the coating (% RSD = 0.3) and the dependence of the EOF on pH (% RSD = 0.5) were also investigated. The CHPEI‐coated capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (<20 min) and acceptable migration‐time repeatability (<0.7% RSD for intra‐capillary and <2% RSD for inter‐capillary).  相似文献   

13.
Fused-silica capillaries chemically derivatized with silane/poly(vinylpyrrolidone) (PVP) or dynamically modified with plexiglas [poly(methyl methacrylate)] were prepared and evaluated with regard to column stability and separation performance for capillary isoelectric focusing of standard proteins. The PVP coating showed the better stability and was good for at least 100 runs while the plexiglas coating started to deteriorate after about 30 runs. The time spent for the plexiglas coating is about 40 minutes while the PVP coating requires two days. The migration time reproducibility was better with the PVP capillary (RSD 0.7-1.6%, n = 5) compared to the plexiglas-coated column (RSD 1.2-2.9%, n = 5) while peak area and height varied over a similar interval (RSD 2-28.1% area; 0.9-22.7% height, n = 5). The two most consistent proteins in this evaluation, viz. myoglobin A and carbonic anhydrase II, showed linear dynamic ranges between 5-150 and 5-50 microg/mL, and limits of detections at 2 and 1 microg/mL, respectively, employing UV detection at 280 nm.  相似文献   

14.
Quasi‐interpenetrating network (quasi‐IPN) of linear polyacrylamide (LPA) with low molecular mass and poly(N,N‐dimethylacrylamide) (PDMA), which is shown to uniquely combine the superior sieving ability of LPA with the coating ability of PDMA, has been synthesized for application in dsDNA and basic protein separation by CE. The performance of quasi‐IPN on dsDNA separation was determined by polymer concentration, electric field strength, LPA molecular masses and different acrylamide (AM) to N,N‐dimethylacrylamide (DMA) ratio. The results showed that all fragments in Φ×174/HaeIII digest were achieved with a 30 cm effective capillary length at –6 kV at an appropriate polymer solution concentration in bare silica capillaries. Furthermore, EOF measurement results showed that quasi‐IPN exhibited good capillary coating ability, via adsorption from aqueous solution, efficiently suppressing EOF. The effect of the buffer pH values on the separation of basic proteins was investigated in detail. The separation efficiencies and analysis reproducibility demonstrated the good potentiality of quasi‐IPN matrix for suppressing the adsorption of basic proteins onto the silica capillary wall. In addition, when quasi‐IPN was used both as sieving matrix and dynamic coating in bare silica capillaries, higher peak separation efficiencies, and better migration time reproducibility were obtained.  相似文献   

15.

A capillary column with a teicoplanin aglycone (TAG) stationary phase (CSP) was used for enantioselective separation of selected profen non-steroidal anti-inflammatory drugs in capillary liquid chromatography (cLC). The effect of variations in the mobile phase composition on the retention and enantioselective separation was examined. The best resolution was attained in the mobile phase composed of 40/60 (v/v) methanol/1.0% triethylamine acetate buffer, pH 4.0 or 4.5. Under the optimized separation conditions, five of the set of eight analytes were enantioresolved with resolution values better than 0.9. Only fenoprofen was not enantioseparated in any system tested. The optimized separation conditions were used for evaluation of three chiral capillary columns (all prepared in the same way in our laboratory) in terms of the repeatability and reproducibility of the results. The run-to-run repeatability was expressed in terms of the relative standard deviation (RSD) values, obtained from ten independent measurements, for the following parameters: the retention factor for the first eluted enantiomer (k 1), the selectivity (α), the enantioresolution (R), the theoretical plate count per meter for the first eluted enantiomer (N 1) and the elution curve asymmetry for the first eluted enantiomer (As 1). None of the RSD values exceeded 8%. The column-to-column reproducibility of these parameters ranged between 1 and 9%. The results obtained with TAG based CSPs in cLC (a laboratory packed capillary column) were compared with those obtained by classical high-performance liquid chromatography (HPLC) with a commercially available column. The cLC procedure provided a better enantioresolution and the elution curves had a better symmetry.

  相似文献   

16.
Graphene oxide (GO) has been considered as a promising stationary phase for chromatographic separation. However, the very strong adsorption of the analytes on the GO surface lead to the severe peak tailing, which in turn resulting in decreased separation performance. In this work, GO and silica nanoparticles hybrid nanostructures (GO/SiO2 NPs@column) were coated onto the capillary inner wall by passing the mixture of GO and silica sol through the capillary column. The successful of coating of GO/SiO2 NPs onto the capillary wall was confirmed by SEM and electroosmotic flow mobilities test. By partially covering the GO surface with silica nanoparticles, the peak tailing was decreased greatly while the unique high shape selectivity arises from the surface of remained GO was kept. Consequently, compared with the column modified with GO (GO@column), the column modified with GO and silica nanoparticles through layer‐by‐layer method (GO‐SiO2 NPs@column), or the column modified with silica nanoparticles (SiO2 NPs@column), GO/SiO2 NPs@column possessed highest resolutions. The GO/SiO2 NPs@column was applied to separate egg white and both acidic and basic proteins as well as three glycoisoforms of ovalbumin were separated in a single run within 36 min. The intra‐day, inter‐day, and column‐to‐column reproducibilities were evaluated by calculating the RSDs of the retention of naphthalene and biphenyl in open‐tubular capillary electrochromatography. The RSD values were found to be less than 7.1%.  相似文献   

17.
In this work, a new copolymer synthesized in our laboratory is used as physically adsorbed coating for capillary electrophoresis (CE). The copolymer is composed of ethylpyrrolidine methacrylate (EPyM) and methylmethacrylate (MMA). The capillary coating is easily obtained by simply flushing into the tubing an EPyM/MMA solution. It is demonstrated that the composition of the EPyM/MMA copolymer together with the selection of the background electrolyte (BGE) and pH allow tailoring the direction and magnitude of the electroosmotic flow (EOF) in CE. It is also shown that the EOF obtained for the EPyM/MMA-coated capillaries was reproducible in all cases independently on pH or polymer composition. Thus, RSD values lower than 1.9% (n=5) for the same capillary and day were obtained for the migration time, while the repeatability interdays (n=5) was observed to provide RSD values lower than 0.5%. The stability of the coating procedure was also tested between capillaries (n=3) obtaining RSD values lower than 0.6%. It is demonstrated with several examples that the use of EPyM/MMA coatings in CE can drastically reduce the analysis time and/or to improve the resolution of the separations. It is shown that EPyM/MMA-coated capillaries allow the separation of basic proteins by reducing their adsorption onto the capillary wall. Also, EPyM/MMA-coated capillaries provide a faster separation of samples containing simultaneously positive and negative analytes. Moreover, it is demonstrated that the use of EPyM/MMA-coated capillaries can incorporate an additional chromatographic-like interaction with nucleosides that highly improves the separation of this group of solutes.  相似文献   

18.
Characterization of amino-terminated polyamidoamine dendrimers by CE suffers from a lack of resolution for higher generations and poor between-day reproducibility of retention times. Under optimal conditions of temperature, voltage, and sample amount, 0-5 generations of dendrimers could be resolved with a bare fused-silica capillary. However, reproducibility was poor due to potential interactions of the polycationic dendrimers with the uncoated quartz capillary wall. Use of a poly(vinyl alcohol)-coated capillary significantly decreased the migration times of the nanomolecules without compromising resolution. Dendrimer mixtures containing generations 0-5 are separated as discrete, nonoverlapping peaks in about 15 min. In addition, the between-day precision of retention times was dramatically improved without the need for internal standards or data normalization. Dendrimers of various generations and cores run on different days showed an RSD of retention times of less than 4%. The poly(vinyl alcohol) coating was very stable as shown by the excellent precision of migration times obtained on a capillary used for a month with more than 100 injections. Similar to PAGE, separation of polyamidoamine dendrimers on a bare fused-silica and poly(vinyl alcohol)-coated capillary showed an exponential relationship between migration times and calculated charge density of the nanomolecules.  相似文献   

19.
A capillary column with a teicoplanin aglycone (TAG) stationary phase (CSP) was used for enantioselective separation of selected profen non-steroidal anti-inflammatory drugs in capillary liquid chromatography (cLC). The effect of variations in the mobile phase composition on the retention and enantioselective separation was examined. The best resolution was attained in the mobile phase composed of 40/60 (v/v) methanol/1.0% triethylamine acetate buffer, pH 4.0 or 4.5. Under the optimized separation conditions, five of the set of eight analytes were enantioresolved with resolution values better than 0.9. Only fenoprofen was not enantioseparated in any system tested. The optimized separation conditions were used for evaluation of three chiral capillary columns (all prepared in the same way in our laboratory) in terms of the repeatability and reproducibility of the results. The run-to-run repeatability was expressed in terms of the relative standard deviation (RSD) values, obtained from ten independent measurements, for the following parameters: the retention factor for the first eluted enantiomer (k 1), the selectivity (α), the enantioresolution (R), the theoretical plate count per meter for the first eluted enantiomer (N 1) and the elution curve asymmetry for the first eluted enantiomer (As 1). None of the RSD values exceeded 8%. The column-to-column reproducibility of these parameters ranged between 1 and 9%. The results obtained with TAG based CSPs in cLC (a laboratory packed capillary column) were compared with those obtained by classical high-performance liquid chromatography (HPLC) with a commercially available column. The cLC procedure provided a better enantioresolution and the elution curves had a better symmetry.  相似文献   

20.
This paper describes the preparation and optimization of packed capillary columns for reversed‐phase separation of steroids with CEC. The fabrication of on‐column frits is considered to be the most important step for obtaining a reproducible packed column for CEC separation. Porous silicate frits were generated in a fused‐silica capillary by heating the silica gel/sodium hydroxide solutions electrically. The optimized conditions involve silica gel (10.8%), sodium hydroxide (5.8%), and heating time (5 sec) with heating voltage (5V) for obtaining a 100‐μ end‐frit that can withstand pressure over 6000 psi. A HPLC pump was utilized to pack the 5‐μm ODS particle slurry into the capillary column. The ODS packed capillaries were then utilized for the separation of four anabolic cholesterols with a capillary electrophoresis system without pressurization of the column. The reproducibility of the packed columns was evaluated by measuring the relative standard deviations of four steroids. The relative standard deviations of migration time for column‐to‐column, day‐to‐day, and run‐to‐run are less than 7%, 2%, and 1% for four steroids, respectively.  相似文献   