首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: This study used an experimental arterial stenosis model in pigs to evaluate the utility of a new medium-weight MRI contrast agent, NMS60 (a synthetic oligomeric Gd complex containing three Gd(3+) atoms, molecular weight of 2158 Da) compared to Gd-DTPA for contrast-enhanced MRA. MATERIALS AND METHODS: We used six male white hybrid pigs. Under anesthesia, one femoral artery was exposed and an inflatable cuff placed around it. The cuff was tightened around the vessel until 80-90% stenosis was achieved using digital subtraction angiography as a guide. Animals were then immediately transferred to the MRI scanner and images acquired pre- and postcontrast injection (0.1 or 0.2 mmol Gd/kg Gd-DTPA or NMS60, as a rapid bolus) using high-resolution and dynamic MRA. RESULTS: The dynamic MRA scans acquired during contrast bolus injection clearly showed the stenosed femoral artery as a segment of close to zero enhancement during the arterial phase of the bolus transit, while on the high-resolution scans the stenosis was difficult to detect due to venous signal contamination. The signal-to-noise at peak enhancement on the dynamic scans was significantly greater with 0.1 mmol Gd/kg NMS60 compared to 0.1 mmol Gd/kg Gd-DTPA (14.6 vs. 9.9, P < .05) and not significantly greater than 0.2 mmol Gd/kg (14.6 vs. 12.8). DISCUSSION AND CONCLUSION: This new medium-weight contrast agent demonstrated significantly greater enhancement than Gd-DTPA and may be valuable to aid detection of vascular stenosis in humans.  相似文献   

2.
In a canine model the signal dynamics of a new oligomer-based MR contrast agent (NMS60, 2158 Da) were compared to Gd-DTPA to investigate the agents' potential for magnetic resonance angiography (MRA). Twelve male mongrel dogs were imaged sequentially under anesthesia with two different MRA sequences (Tlw 3DSPGR). Initial enhancement was measured every 9 s for eight points in time. Thereafter, spatial highly resolved MRAs were obtained at 5, 10, 15, 20, 30, 45, and 60 min post-injection of two different dosages. Over the first 20 s following bolus administration the average arterial enhancement of 0.1 mmol(Gd)kg NMS60 was 44% greater than Gd-DTPA. Twenty minutes post-injection the relative signal intensity of NMS60 was as high as the peak signal intensity with Gd-DTPA at the same dosage level (0.1 mmol(Gd)/kg). In the animals that received NMS60 injections the vascular conspicuity was overly superior to those who received Gd-DTPA. No significant toxicity effects were noted for either dosage level. The intermediate weight contrast agent NMS60 offers greater vascular enhancement and retention time than Gd-DTPA. For a given set of optimized imaging parameters this offers improved spatial details, less arterial/venous overlap, and better vascular contrast.  相似文献   

3.
We studied the dynamics of injected contrast enhancement in implanted VX2 tumors in rabbit thigh muscle. We compared two contrast agents Gd-DTPA and NMS60, a novel gadolinium containing trimer of molecular weight 2.1 kd. T1-weighted spin echo images were acquired preinjection and at 5-60 min after i.v. injection of 0.1 mmol/kg of agent. Dynamic T1-weighted SPGR images (1.9 s/image) were acquired during the bolus injection. Male NZW rabbits (n = 13) were implanted with approximately 2 x 10(6) VX2 tumor cells and grew tumors of 28+/-27 mL over 12 to 21 days. NMS60 showed significantly greater peak enhancement in muscle, tumor rim, and core compared to DTPA in both T1-weighted and SPGR images. NMS60 also showed delayed peak enhancement in the dynamic scans (compared to Gd-DTPA) and significantly reduced leakage rate constant into the extravascular space for tumor rim (K21 = 5.1 min(-1) vs. 11.5 min(-1) based on a 2 compartment kinetic model). The intermediate weight contrast agent NMS60 offers greater tumor enhancement than Gd-DTPA and may offer improved regional differentiation on the basis of vascular permeability in tumors.  相似文献   

4.
通过二乙三胺五乙酸单环酸酐(DTPA-MA)分别与L-赖氨酸的十八酯、十六酯、十四酯和十二酯的双酰化反应, 制得四种含有双DTPA螯合单元的新型配体. 它们与GdCl3·6H2O配合得到相应的双核钆(Ⅲ)配合物. 表征了配体和配合物的结构, 测试了配合物的纵向弛豫效能(R1). 结果表明: 这四种新钆配合物的R1都高于Gd-DTPA.  相似文献   

5.
This study compared two methods, corrected (separation of T(1) and T(2)* effects) and uncorrected, in order to determine the suitability of the perfusion and permeability measures through Delta R(2)* and Delta R(1) analyses. A dynamic susceptibility contrast dual gradient echo (DSC-DGE) was used to image the fixed phantoms and flow phantoms (Sephadex perfusion phantoms and dialyzer phantom for the permeability measurements). The results confirmed that the corrected relaxation rate was linearly proportional to gadolinium-diethyltriamine pentaacetic acid (Gd-DTPA) concentration, whereas the uncorrected relaxation rate did not in the fixed phantom and simulation experiments. For the perfusion measurements, it was found that the correction process was necessary not only for the Delta R(1) time curve but also for the Delta R(2)* time curve analyses. Perfusion could not be measured without correcting the Delta R(2)* time curve. The water volume, which was expressed as the perfusion amount, was found to be closer to the theoretical value when using the corrected Delta R(1) curve in the calculations. However, this may occur in the low concentration of Gd-DTPA in tissue used in this study. For the permeability measurements based on the two-compartment model, the permeability factor (k(ev); e = extravascular, v = vascular) from the outside to the inside of the hollow fibers was greater in the corrected Delta R(1) method than in the uncorrected Delta R(1) method. The differences between the corrected and the uncorrected Delta R(1) values were confirmed by the simulation experiments. In conclusion, this study proposes that the correction for the relaxation rates, Delta R(2)* and Delta R(1), is indispensable in making accurate perfusion and permeability measurements, and that DSC-DGE is a useful method for obtaining information on perfusion and permeability, simultaneously.  相似文献   

6.
The arterial input function (AIF) is important for quantitative MR imaging perfusion experiments employing Gd contrast agents. This study compared the accuracy of T(2)*-weighted magnitude and phase imaging for noninvasive measurement of the AIF in the rat aorta. Twenty-eight in vivo experiments were performed involving simultaneous arterial blood sampling and MR imaging following Gd injection. In vitro experiments were also performed to confirm the in vivo results. At 1.89 T and TE=3 ms, the relationship between changes in 1/T(2)* in blood (estimated from MR signal magnitude) and Gd concentration ([Gd]) was measured to be approximately 19 s(-1) mM(-1), while that between phase and [Gd] was approximately 0.19 rad mM(-1). Both of these values are consistent with previously published results. The in vivo phase data had approximately half as much scatter with respect to [Gd] than the in vivo magnitude data (r(2)=.34 vs. r(2)=.17, respectively). This is likely due to the fact that the estimated change in 1/T(2)* is more sensitive than the phase to a variety of factors such as partial volume effects and T(1) weighting. Therefore, this study indicates that phase imaging may be a preferred method for measuring the AIF in the rat aorta compared to T(2)*-weighted magnitude imaging.  相似文献   

7.
Two gadolinium-sandwiched complexes with tungstosilicates, K(13)[Gd(SiW(11)O(39))(2)] (Gd(SiW(11))(2)) and K(11)H(6)[Gd(3)O(3)(SiW(9)O(34))(2)] (Gd(3)(SiW(9))(2)), have been investigated by in vitro and in vivo experiments as potential contrast agents for magnetic resonance imaging (MRI). T(1)-relaxivity of Gd(SiW(11))(2)was 6.59 mM(-1).s(-1) in aqueous solution and 6.85 mM(-1).s(-1) in 0.725 mmol.L(-1) bovine serum albumin solution at 25 degrees C and 9.39 T, respectively. The corresponding T(1)-relaxivity of Gd(3)(SiW(9))(2) was 12.6 and 19.3 mM(-1).s(-1) per Gd, respectively. MRI for Sprague-Dawley rats showed longer and more remarkable enhancement in rat liver after i.v. injection of these two complexes: 39.4 +/- 3.9% and 57.4 +/- 11.6% within the first 30 min after injection, 31.2 +/- 2.6% and 39.9 +/- 7.6% in the next 60 min for Gd(SiW(11))(2) and Gd(3)(SiW(9))(2) at doses of 0.081 and 0.084 mmol Gd/kg, respectively. Our preliminary in vitro and in vivo study indicates that Gd(SiW(11))(2) and Gd(3)(SiW(9))(2) are favorable candidates for hepatic contrast agents for MRI. However, the two complexes exhibit higher acute toxicity and need to be modified and studied further before clinical use.  相似文献   

8.
The DTPA ligand modified by heterocyclic compound and linked through double alkyl ester covalent bond was synthesized by acylation reaction between diethylenetriamine pentaacetic (DTPA) bisanhydride and a novel heterocyclic compound. The corresponding paramagnetic Gd(III) complex was gained by the reaction of the DTPA ligand with GdCl3.6H2O. The structure of the ligand and its Gd(III) complex was characterized by elemental analysis, FTIR and 1H NMR, and the longitudinal relaxivity (R1) was measured. Besides, the magnetic resonance imaging of the new Gd(III) complex in vitro was studied. The result suggested that the stability of the complex was well, and when the Gd(III) quantity was identical, the R1 of the Gd(III) complex (5.12 mmol x L(-1) x s(-1)) was higher than the clinical magnetic resonance imaging contrast agent Gd-DTPA (3.64 mmol x L(-1).  相似文献   

9.
Gd2O3 particles (less than 2 microns) in suspension were evaluated as a potential contrast agent for liver-spleen imaging with magnetic resonance. The agent was administered IV to rabbits in doses ranging from 10 to 120 mumol/kg and the tissues removed after sacrifice for in vitro T1 and T2 analysis. The temporal response was determined in liver and spleen samples of rabbits given a fixed dose (60 mumol/kg) and sacrificed at intervals from 15 min to 60 hr later. Documentation of the subanatomic location of Gd2O3 particles in tissue was accomplished by electron microscopy and x-ray dispersion microanalysis. T1 weighted images were obtained at 0.12T on a prototype resistive scanner. The liver, spleen, and lung relaxation times are very responsive to Gd2O3 IV and the effect is dose related. A peak effect is observed between 3-7 hr after injection and relaxation times may normalize by 60 hr. By electron microscopic and x-ray analysis, Gd2O3 is most prominently found in the hepatic and splenic sinusoids. The images show marked enhancement of liver and splenic tissues, aiding in the clear delineation of these tissues from neighboring structures.  相似文献   

10.
The structural effect of biodegradable macromolecular magnetic resonance imaging (MRI) contrast agents, polydisulfide gadolinium (Gd)(III) chelates, on their in vitro degradability, and cardiovascular and tumor imaging were evaluated in mice. Polydisulfide Gd(III) chelates, Gd-DTPA cystamine copolymers (GDCC), Gd-DTPA l-cystine copolymers (GDCP), Gd-DTPA d-cystine copolymers (dGDCP) and Gd-DTPA glutathione (oxidized) copolymers (GDGP), with different sizes and narrow molecular weight distribution were prepared and evaluated both in vitro and in vivo in mice bearing MDA-MB-231 tumor xenografts. GDGP with large steric hindrance around the disulfide bonds had greater T(1) and T(2) relaxivities than GDCC, GDCP and dGDCP. The degradability of the polydisulfide by the endogenous thiols decreased with increasing steric effects around the disulfide bonds in the order of GDCC>GDCP, dGDCP>GDGP. The size and degradability of the contrast agents had a significant impact on vascular contrast enhancement kinetics. The agents with a large size and low degradability resulted in more prolonged vascular enhancement than the agents with a small size and high degradability. It seems that the size and degradability of the agents did not significantly affect tumor enhancement. All agents resulted in significant contrast enhancement in tumor tissue. This study has demonstrated that the vascular enhancement kinetics of the polydisulfide MRI contrast agents can be controlled by their sizes and structures. The polydisulfide Gd(III) chelates are promising biodegradable macromolecular MRI contrast agents for magnetic resonance angiography and cancer imaging.  相似文献   

11.
The neurotoxicity of intravenously injected Gadolinium (Gd) complexes to rats with disrupted blood-brain barrier (BBB) was evaluated. After disruption of the BBB by infusion of mannitol solution, one of several contrast agents tested was injected intravenously at a dose of 1 or 3 mmol Gd/kg, and neurological symptoms were graded. The concentrations of Gd in brain and plasma were also measured. Injection of Gd-DTPA at a dose of 3 mmol Gd/kg did not change behavior. On the other hand, Gd-DTPA-BMA, Gd-DO3A-butrol, and Gd-DO3A-HP each induced behavioral impairments, and some animals died within 1 h after injection. Gd-DO3A-HP showed lethal effect even at a dose of 1 mmol/kg. The concentration of Gd in the brain of the animals injected with Gd-DO3A-HP at 3 mmol Gd/kg was essentially the same as that of animals injected with Gd-DTPA at the same dose. The neurotoxicity of the contrast agents tested was graded as follows: Gd-DTPA ≤ Gd-DTPA-BMA = Gd-DO3A-butrol < Gd-DO3A-HP.  相似文献   

12.
The transverse relaxation rate (R2=1/T2) of many biological tissues are altered by endogenous magnetized particles (i.e., ferritin, deoxyhemoglobin), and may be sensitive to the pathological progression of neurodegenerative disorders associated with altered brain-iron stores. R2 measurements using Carr-Purcell-Meiboom-Gill (CPMG) acquisitions are sensitive to the refocusing pulse interval (2taucp), and have been modeled as a chemical exchange (CE) process, while R2 measurements using a localization by adiabatic selective refocusing (LASER) sequence have an additional relaxation rate contribution that has been modeled as a R2rho process. However, no direct comparison of the R2 measured using these two sequences has been described for a controlled phantom model of magnetized particles. The three main objectives of this study were: (1) to compare the accuracy of R2 relaxation rate predictions from the CE model with experimental data acquired using a conventional CPMG sequence, (2) to compare R2 estimates obtained using LASER and CPMG acquisitions, and (3) to determine whether the CE model, modified to account for R2rho relaxation, adequately describes the R2 measured by LASER for a full range of taucp values. In all cases, our analysis was confined to spherical magnetic particles that satisfied the weak field regime. Three phantoms were produced that contained spherical magnetic particles (10 microm diameter polyamide powders) suspended in Gd-DTPA (1.0, 1.5, and 2.0 mmol/L) doped gel. Mono-exponential R2 measurements were made at 4T as a function of refocusing pulse interval. CPMG measurements of R2 agreed with CE model predictions while significant differences in R2 estimates were observed between LASER and CPMG measurements for short taucp acquisitions. The discrepancy between R2 estimates is shown to be attributable to contrast enhancement in LASER due to T2rho relaxation.  相似文献   

13.
通过二乙三胺五乙酸(DTPA)酸酐与一种新型杂环化合物的酰化反应,得到了双酰胺共价键链接、杂环化合物修饰的DTPA配体。再与GdCl3·6H2O反应得到相应的顺磁性钆(Ⅲ)配合物。通过元素分析、FTIR、1H NMR等手段表征了配体和金属配合物的结构,进而测定了配合物的纵向弛豫率(R1)。结果表明,配合物分子稳定性很好,且在同等含钆量条件下,这种新型钆(Ⅲ)金属配合物的R1(5.12 mmol·L-1·s-1)高于临床应用的磁共振成像对比剂Gd-DTPA(3.64 mmol·L-1·s-1)。  相似文献   

14.
Because meningiomas tend to recur after (partial) surgical resection, radiotherapy is increasingly being applied for the treatment of these tumors. Radiation dose levels are limited, however, to avoid radiation damage to the surrounding normal tissue. The radiosensitivity of tumors can be improved by increasing tumor oxygen levels. The aim of this study was to investigate if breathing a hyperoxic hypercapnic gas mixture could improve the oxygenation of meningiomas. Blood oxygen level-dependent magnetic resonance imaging and dynamic Gadolinium (Gd)-DTPA contrast-enhanced MRI were used to assess changes in tumor blood oxygenation and vascularity, respectively. Ten meningioma patients were each studied twice; without and with breathing a gas mixture consisting of 2% CO(2) and 98% O(2). Values of T(2)* and the Gd-DTPA uptake rate k(ep) were calculated under both conditions. In six tumors a significant increase in the value of T(2)* in the tumor was found, suggesting an improved tumor blood oxygenation, which exceeded the effect in normal brain tissue. Contrarily, two tumors showed a significant T(2)* decrease. The change in T(2)* was found to correlate with both k(ep) and with the change in k(ep). The presence of both vascular effects and oxygenation effects and the heterogeneous response to hypercapnic hyperoxia necessitates individual assessment of the effects of breathing a hyperoxic hypercapnic gas mixture on meningiomas. Thus, the current MRI protocol may assist in radiation treatment selection for patients with meningiomas.  相似文献   

15.
In order to assess the sensitivity of nuclear magnetic resonance (NMR) in detecting acute renal vascular insufficiency, in vitro NMR spectroscopy (at 0.25 T) was performed on rabbit renal cortices following 45 min of unilateral renal artery (RAO) or renal vein occlusion (RVO). Data were obtained both with and without paramagnetic enhancement with gadolinium-DTPA (Gd-DTPA). In the absence of contrast material, RVO was distinguished by markedly elevated spin-lattice (T1) and spin-spin (T2) relaxation times when compared to the contralateral control kidney [mean increase of 29% in T1 (p less than 0.001) and 19% in T2 (p less than .001)]. RAO produced no change in T1 (p = N.S.) and a small change in T2 (mean increase of 11%, p less than .01). Five min following injection of 0.05 mM/kg of Gd-DTPA, relaxation times of control kidneys were markedly shortened [mean decrease 75% in T1 (p less than .001) and 12% in T2 (p less than 0.01)]. With Gd-DTPA, kidneys with RVO continued to have elevated T1 and T2 relaxation time, and kidneys with RAO maintained their essentially normal pre-contrast relaxation time values. We conclude that non-contrast NMR tissue analysis clearly differentiated normal from congested (RVO) kidneys, but not from acutely ischemic (RAO) kidneys. Paramagnetic enhancement with Gd-DTPA allows the differentiation of normally perfused from acutely ischemic or congested kidneys.  相似文献   

16.
GD HP-DO3A, a neutral (nonionic) IV MR contrast agent presently in clinical trials, was evaluated with respect to imaging characteristics in rats. Following administration of 0.25 mmol/kg I.V., 58 +/- 19%, i.e. (n = 6) enhancement was noted in a brain gliosarcoma model. Meningeal spread of neoplasia could be identified due to its enhancement (69 +/- 26%) in nine animals. The time course of renal enhancement was quantitated at two dosages, 0.05 (n = 4) and 0.25 mmol/kg (n = 8). At the higher dose, enhancement of both cortex and medulla plateaued between 9 and 23 min postinjection. At the lower dose, enhancement of renal medulla was maximum at 2 min postinjection. These enhancement characteristics (both brain and kidney), at equivalent contrast dosages, are comparable to that previously published for Gd-DTPA. However, Gd HP-DO3A has the potential to be utilized clinically at higher doses than Gd-DTPA, with no reported adverse effects in initial trials employing up to 0.3 mmol/kg.  相似文献   

17.
Proton NMR longitudinal and transverse relaxation rates of unlabelled proteins are generally dominated by the many 1H-1H dipolar interactions so that spin diffusion, rather than molecular or internal motions, governs longitudinal relaxation. Here, relaxation measurements of backbone amide proton (1H(N)) magnetisations have been carried out employing the 99% 2H, 98% 15N labelled, small 2F2 protein domain in 10%/90% H(2)O/D(2)O solution. Under these conditions, the longitudinal relaxation rates exhibit time constants, T(1)*=1/R(1)* if described by a mono-exponential, within the range of 3.0 to 18.7s-a wide range which indicates that the phenomenon of spin diffusion has been greatly reduced. The majority of 1H(N) nuclei in this sample (pH 4.0 and 5 degrees C) exhibit chemical exchange with solvent that couples their longitudinal relaxation to that of the solvent. For the subset of 1H(N) nuclei not undergoing detectable solvent chemical exchange, the R(1)* rates correlate well with their individual 1H(N,O)/2H(N,O) structural environments. The correlation for corresponding transverse relaxation rates, R(2)* was found to be less good. Longitudinal relaxation measurements in 1%/99% H(2)O/D(2)O solution identify a further subset of 1H(N) nuclei which exhibit essentially indistinguishable R(1)* rates in both 1% and 10% H(2)O, implying that averaging of rates from spin diffusion processes and different 2F2 isotopomer populations are negligible for these 1H(N) sites. In addition to a high sensitivity to structural parameters, model calculations predict 1H(N) relaxation rates to exhibit pronounced sensitivity to internal dynamics.  相似文献   

18.
Depth and orientational dependencies of microscopic magnetic resonance imaging (MRI) T(2) and T(1ρ) sensitivities were studied in native and trypsin-degraded articular cartilage before and after being soaked in 1 mM Gd-DTPA(2-) solution. When the cartilage surface was perpendicular to B(0), a typical laminar appearance was visible in T(2)-weighted images but not in T(1ρ)-weighted images, especially when the spin-lock field was high (2 kHz). At the magic angle (55°) orientation, neither T(2)- nor T(1ρ)-weighted image had a laminar appearance. Trypsin degradation caused a depth- and orientational-dependent T(2) increase (4%-64%) and a more uniform T(1ρ) increase at a sufficiently high spin-lock field (55%-81%). The presence of the Gd ions caused both T(2) and T(1ρ) to decrease significantly in the degraded tissue (6%-38% and 44%-49%, respectively) but less notably in the native tissue (5%-10% and 16%-28%, respectively). A quantity Sensitivity was introduced that combined both the percentage change and the absolute change in the relaxation analysis. An MRI experimental protocol based on two T(1ρ) measurements (without and with the presence of the Gd ions) was proposed to be a new imaging marker for cartilage degradation.  相似文献   

19.
The biodistribution and relative molar effectiveness of the ionic (GdCl3) and chelated (Gd-DTPA) forms of gadolinium (Gd) to enhance proton relaxation rates in rat kidney, liver and spleen were evaluated. Rats were given intravenous injections of either GdCl3 (100 mumol/kg) or Gd-DTPA (178 mumol/kg). Gd-DTPA was primarily contained in the vascular compartment and was quickly accumulated in the kidney after injection with a relaxivity of 4.3 sec-1 (mumol/g kidney)-1. It was eliminated quickly from the body with only 2% of the injected dose remaining after 120 min. After GdCl3 injection, Gd was found primarily in liver and spleen. It accumulated continuously reaching 72% of the injected does in these two tissues after 120 min. Despite this continuous increase in tissue Gd concentration, the relaxation rates showed saturation in liver and spleen. The results suggest that after GdCl3 was injected it distributed either in a protein bound form that was effective at causing relaxation or in a colloid form that was not effective. The biodistribution of GdCl3 was such that it was determined by the phagocytic action of the recticuloendothelial system on a colloid. The biodistribution and tissue relaxivity of Gd-DTPA suggest it will be a useful vascular MRI contrast agent. However, the usefulness of GdCl3 as an MRI contrast agent is limited not only by its acute toxicity but also by its saturable effect on tissue relaxation rates. Consequently, GdCl3 has only a modest influence on tissue relaxivity.  相似文献   

20.
In this work an interleaved multiple-gradient-echo chemical shift imaging (IMGE-CSI) technique was designed, implemented and evaluated at 1.5 and 4T for high-resolution lipid quantification and R(2)* measurement in-vivo. The method is analogous to echo planar CSI but utilizes conventional gradient echoes, exploiting the principle of spectroscopic bandwidth extension by interleaving temporally offset gradient-echo trains. It is shown that IMGE-CSI is able to measure true fat volume fraction in oil/water mixtures with high accuracy, not possible with Dixon-type methods which approximate the spectrum as consisting of only two spectral components. Correlation of the CSI- derived volume fractions with volumetry afforded r(2) > 0.99 with a slope of 0.98. The method is shown to be able to quantify regional variations in bone marrow composition in vivo with a spatial resolution of 2.5 x 2.5 x 5 mm(3.) R(2)* was obtained by multi-line spectral curve fitting. For the measurement of R(2)* in cancellous bone marrow the method is shown to agree well with time-domain fitting techniques but is superior in instances where the marrow has both hematopoietic and fatty constituents. Finally, excellent inter-scan reproducibility (1% coefficient of variation for global means and medians) was achieved, yielding r(2) = 0.98 of the test-retest correlation for three scans in four test subjects. In conclusion, IMGE-CSI is found to enable highly accurate lipid quantification and measurement of cancellous bone marrow R(2)* at spatial resolutions and scan times typical of standard clinical protocols.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号