首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 906 毫秒
1.
Shamsi SA  Miller BE 《Electrophoresis》2004,25(23-24):3927-3961
We describe here the state-of-the-art development of on-line capillary electrophoresis-mass spectrometry (CE-MS) over the last two years. Technological developments included are novel designs of new interfaces and ionization sources, new capillary coatings, buffers, and micelles as well as application of various modes of CE-MS published in the recent literature. The areas of CE-MS application in analysis of small achiral and chiral solutes are covered in sections that highlight the recent advances and possibilities of each mode of CE-MS. Application areas reviewed in this paper include achiral and chiral pharmaceuticals, agrochemicals, carbohydrates, and small peptides. The separation of enantiomers using micellar electrokinetic chromatography (MEKC)-MS with molecular micelles and capillary electrochromatography (CEC)-MS using pack tapered columns appears to provide good tolerance to electrospray stability for routine on-line CE-MS. These two modes seem to be very suitable for sensitive detection of chiral pharmaceuticals in biological samples, but their use will probably increase in the near future. Overall, it seems that one mode of CE-MS, in particular capillary zone electrophoresis (CZE)-MS, is now recognized as established technique for analysis of small charged solutes, but other modes, such as MEKC-MS and CEC-MS, are still within a period of development in terms of both MS-compatible pseudostationary phases and columns as well as applications.  相似文献   

2.
The on-line coupling of capillary zone electrophoresis with mass spectrometry (CZE-MS) for the separation of enantiomers is hampered by the presence of nonvolatile chiral selectors such as cyclodextrins in the separation buffer. This problem can be overcome by use of the partial filling technique where only a part of the capillary is filled with the separation buffer containing chiral selectors. Since the electroosmotic flow is almost completely suppressed at acidic pH, that dimethyl-beta-cyclodextrin is neutral, no free cyclodextrin would reach the MS detector when using a partially filled capillary. By this method, clenbuterol enantiomers were successfully resolved and separated from salbutamol (internal standard) in aqueous solution and in plasma samples. A solid-phase extraction (SPE) was used for the preparation of plasma samples before analysis.  相似文献   

3.
Stutz H 《Electrophoresis》2005,26(7-8):1254-1290
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.  相似文献   

4.
The application of peptides in chiral separations using techniques such as capillary electrophoresis (CE), electrokinetic capillary chromatography (EKC) and liquid chromatography is the focus of this review. Methods for finding peptide selectors using combinatorial library approaches are discussed, as well as recent advances in the use of peptides as general chiral selectors for electrophoresis and liquid chromatography. One example shows the effectiveness of polymeric dipeptide surfactants as general chiral selectors for electrophoresis. Another example shows the versatility of oligoproline chiral stationary phases, exhibiting resolution for a number of racemic analytes comparable to other well-established chiral stationary phases.  相似文献   

5.
TANAKA Yoshihide 《色谱》2002,20(4):317-327
 Capillary electrophoresis (CE) has become a powerful tool for enantiomer separations during the last decade. Since 1993, the author has investigated enantiomer separations by affinity capillary electrophoresis (affinity CE) with some proteins and by cyclodextrin electrokinetic chromatography (CDEKC) with some charged cyclodextrins (CDs). Many successful enantiomer separations are demonstrated from our study in this review article. In the enantiomer separations by affinity CE, the deterioration of detection  相似文献   

6.
微量金属元素的毛细管电泳分析方法及应用   总被引:9,自引:1,他引:8  
屈锋  王敏  林金明 《分析化学》2005,33(4):562-568
综述了毛细管电泳分析微量金属元素的基本原理、分离模式(CZE、MKEC、非水电泳、芯片分离等)、检测方法(紫外、荧光、化学发光、安培、电导、质谱联用技术)等的进展和该技术在环境、生物医学领域的研究与应用。引用文献94篇。  相似文献   

7.
Recent progress in chiral separation principles in capillary electrophoresis   总被引:11,自引:0,他引:11  
Gübitz G  Schmid MG 《Electrophoresis》2000,21(18):4112-4135
This review summarizes recent developments in the field of chiral separations by electromigration techniques including capillary zone electrophoresis (CZE), capillary gel electrophoresis (CGE), isotachophoresis (ITP), electrokinetic chromatography (EKC), and capillary electrochromatography (CEC). This overview focuses on the development of new chiral selectors and the introduction of new techniques rather than applications of already established selectors and methods. The mechanisms of the different chiral separation principles are discussed.  相似文献   

8.
The capillary electrophoretic (CE) separation of the enantiomers of three binaphthyl compounds is investigated. Several CE modes such as cyclodextrin (CD) modified capillary zone electrophoresis (CZE) (CD-CZE), micellar electrokinetic chromatography (MEKC), cyclodextrin electrokinetic chromatography (CD-EKC), etc. are employed for the simultaneous enantiomer separation of the three solutes. The successful separation was achieved by combining two modes, in other words by using more than two chiral selectors. A development of the CE enantiomer separation is demonstrated for the binaphthyl compounds. The enantioselectivity of binaphthyl compounds is alo briefly discussed.  相似文献   

9.
毛细管电泳在手性分离中的应用进展   总被引:5,自引:0,他引:5  
李洪霞  李伟  谷学新 《化学研究》2005,16(2):96-100
本文以手性选择剂为线索综述了近五年来毛细管区带电泳和胶束电动毛细管电色谱在手性药物拆分中的应用进展,列举了部分手性药物拆分实例.  相似文献   

10.
The concept of interfacing a large-size column for capillary electrophoresis (CE) to electrospray ionization mass spectrometry (ESI-MS) for robust and automatic CE-MS operation is reported. Both standard ionspray interface and microionspray interface have been modified to operate in a sheath flow pattern to overcome the common stability problem in CE-MS coupling. To make the interface sensitive, a step-down stainless steel tube with smaller inner diameter and tapered tip was incorporated onto a larger tube embracing the CE column via cold soldering. The devices were evaluated for quantitative analysis of nucleotides at femtomole level and stable analytical performance in peptide profiling.  相似文献   

11.
Gübitz G  Schmid MG 《Electrophoresis》2004,25(23-24):3981-3996
This review summarizes recent developments in chiral separation in capillary zone electrophoresis (CZE), electrokinetic chromatography (EKC), and capillary electrochromatography (CEC) covering literature published since the year 2000. New chiral selectors and innovative approaches for CE and CEC are introduced. Recent progress in column technology for CEC is highlighted and the development of new chiral stationary phases is discussed. This review is not dedicated to list applications but will focus on new developments.  相似文献   

12.
The prediction of peptide mobility by capillary electrophoresis (CE) coupled to electrospray mass spectrometry (MS) is studied in order to verify the validity of the semi-empirical models developed in classical CE. This work relies on the experimental determination of the electrophoretic mobilities of 68 peptides, different in charge and in size. The results indicate that the prediction is possible in CE-MS experiments, in spite of the restraints inherent in the coupling conditions. The best fit of experimental data was obtained with the Offord's model. The efficiency of the model was confirmed by the analysis of a peptide mixture in CE-MS.  相似文献   

13.
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.  相似文献   

14.
Simó C  Rizzi A  Barbas C  Cifuentes A 《Electrophoresis》2005,26(7-8):1432-1441
In this work, the development of a new chiral capillary electrophoresis-mass spectrometry (CE-MS) method to separate D- and L-amino acids is shown. On-line coupling between CE and MS is established through an electrospray-coaxial sheath flow interface. Enantiomer separation is achieved by using a cheap, nonvolatile, chiral selector as beta-cyclodextrin in the background electrolyte (BGE) together with a physically coated capillary that is aimed to prevent contamination of the electrospray. The capillary coating is simple and easy to obtain as it only requires flushing of the capillary with a polymer aqueous solution for 3 min. Optimization of CE parameters (pH of BGE, type and concentration of chiral selector, and capillary inner diameter) and electrospray-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure) is carried out. Two different derivatization protocols of amino acids using dansyl chloride (DNS) and fluorescein isothiocyanate (FITC) are compared in terms of MS sensitivity and chiral resolution. Under optimum CE-MS conditions it is observed that the MS sensitivity obtained for FITC- and DNS-amino acids is similar (with limit of detection (LOD) in the microM range, corresponding to amounts injected in the fmol range) while chiral resolution is better for FITC-amino acids. The optimized method is demonstrated to provide the simultaneous analysis of 15 selected amino acids (i.e., FITC-D/L-Asp, -Glu, -Ser, -Asn, -Ala, -Pro, -Arg, and FITC-gamma-aminobutyric acid (GABA) in a single chiral CE-MS run, corresponding to the main amino acids that can be found in orange. Moreover, as a result of the high resolution achieved, it is possible to detect down to 2% of D-Asp in the presence of 98% of L-Asp. The good possibilities of chiral CE-MS in food analysis are corroborated through the detection of the main amino acids in a commercial orange juice (i.e., FITC-L-Asp, -Glu, -Ser, -Asn, -Pro, -Arg, and the nonchiral FITC-GABA) as well as the determination of the fraudulent addition of synthetic amino acids (containing D- and L-forms) to a fresh orange juice.  相似文献   

15.
Highly reliable and accurate analytical methods are needed for the determination of magnetic resonance imaging (MRI) contrast agents in complex matrices of clinical interest. We demonstrate the reliability of capillary zone electrophoresis (CZE) coupled with electrospray ionization-mass spectrometry (ESI-MS) for the analysis of MultiHance (gadobenate dimeglumine), a gadolinium-based MRI agent. A sheath liquid interface connected the CE system with an electrospray mass spectrometer equipped with an ion-trap analyzer. CZE with ultraviolet (CZE-UV) and with mass detection (CZE-MS) were compared by analyzing gadobenate dimeglumine and the free ligand diluted in water and in biological fluids (i.e., human serum and urine). The optimization of some relevant CZE-MS parameters was accomplished, like CE buffer composition, sheath liquid composition and flow, and type and length of the separation capillary. CZE-UV was highly influenced by the biological sample components, which hindered a reliable quantification of both gadobenate and free ligand in serum and urine. In CZE-MS, on the other hand, the electrophoretic runs turned out to be independent of the clinical matrices, due to the informative potential and to the selectivity of MS detection.  相似文献   

16.
A sheath-flow capillary electrophoresis-mass spectrometry (CE-MS) system utilizing a fully integrated large-bore stainless-steel emitter electrode tapered at the end for micro-ionspray operation has been developed and evaluated. A separation capillary with an outer diameter of up to 360 microm was inserted into the electrode thus forming a void volume of less than 15 nL between the capillary end and the electrospray ionisation (ESI) tip. The sheath liquid, usually methanol-water (80:20) with 0.1% formic acid for positive ion mode or methanol for negative ion mode, was delivered at 0.5-1.0 microL/min. Unlike previously reported CE-MS interfaces, the CE-MS probe was incorporated directly onto an Applied Biosystems/MDS SCIEX orthogonal-spray Turbo "V" ion source for ease of use and automatic operation. This integration enables fast and facile coupling and replacement of the separation capillary without interrupting the ion source configuration, and the sheath liquid supply. The reusable electrospray electrode was precisely fabricated and aligned with the length of the nebulizing gas tube for improved reproducibility. Automation was achieved through software control of both CE and tandem MS (MS/MS) for unattended batch sample analysis. The system was evaluated for attomole- to low femtomole-level profiling of model peptides and protein mixtures, bisphosphates, as well as antiviral nucleosidic drugs in cellular extracts.  相似文献   

17.
This work reviews the literature of chiral capillary electrokinetic chromatography from January 2016 to March 2021. This is done to explore the state-of-the-art approach and recent developments carried out in this field. The separation principle of the technique is described and supported with simple graphical illustrations, showing migration under normal and reversed polarity modes of the separation voltage. The most relevant applications of the technique for enantioseparation of drugs and other enantiomeric molecules in different fields using chiral selectors in single, dual, or multiple systems are highlighted. Measures to improve the detection sensitivity of chiral capillary electrokinetic chromatography with UV detector are discussed, and the alternative aspects are explored, besides special emphases to hyphenation compatibility to mass spectrometry. Partial filling and counter migration techniques are described. Indirect identification of the separated enantiomers and the determination of enantiomeric migration order are mentioned. The application of Quality by Design principles to facilitate method development, optimization, and validation is presented. The elucidation and explanation of chiral recognition in molecular bases are discussed with special focus on the role of molecular modeling.  相似文献   

18.
Tang FP  Leung GN  Wan TS 《Electrophoresis》2001,22(11):2201-2209
A capillary electrophoresis-mass spectrometry (CE-MS) method for the analysis of quaternary ammonium drugs in equine urine was developed. Quaternary ammonium drugs were first extracted from equine urine by ion-pair extraction and then analysed by CE-MS in the positive electrospray ionization (ESI) mode. Within 12 min, eight quaternary ammonium drugs, each at 1 ng/mL in horse urine, could be detected. The confirmation of these drugs in urine samples was achieved by capillary electrophoresis tandem mass spectrometry (CE-MS/MS). A direct comparison of this method was made with existing liquid chromatography/mass spectrometry (LC-MS) methods in the detection and confirmation of glycopyrrolate and ipratropium bromide in horse urine. While the two drugs could be detected within the same CE-MS run at 1 ng/mL in urine, they could only be detected in separate LC-MS runs at 5 ng/mL in urine. In addition, CE-MS consumed a much smaller volume of extract; the analyte peak widths, in some cases, were much narrower; and as the quaternary ammonium ions were well separated electrophoretically from the mainly neutral urine matrix, a much cleaner background in the CE-MS total ion trace was observed.  相似文献   

19.
Capillary electrophoresis (CE) is a powerful separation technique that was used in a wide range of analytical chemical applications. Cyclodextrins(CDs) are the most commonly used chiral selectors in chiral capillary electrophoresis at the present time. Under neutral conditions, however, native CDs are neutral and usually applicable only for the enantioseparation of charged analyses. To overcome this defect we modified α- and β-CD with a L-cysteine moiety and used the CD derivatives as chiral selectors for the separation of a-amino acid enantiomers by the ligand exchange mode.  相似文献   

20.
Two amphiphilic aminosaccharide derivatives were investigated as chiral selector additives in capillary electrophoresis. Each substance has a glucosamine backbone carrying three hydrocarbon chains as the hydrophobic region and three carboxylic groups as the hydrophilic region, which is an artificial biologically active compound. Using each compound as a chiral selector, the optical resolution of dansylated amino acids or new quinolone antibacterial agents (NQs) was observed. Increasing the concentration of the chiral selector or the ionic strength of running solution led to successful optical resolution. In consideration of the chemical structure of each selector and the migration behavior of the enantiomers, the resolution seemed to be based on micellar electrokinetic chromatography mode. Both selectors differed in their enantioselectivity for dansylated amino acids or NQs although the chemical structures were similar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号