首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
He JT  Shi ZH  Yan J  Zhao MP  Guo ZQ  Chang WB 《Talanta》2005,65(3):621-626
A biotin-avidin amplified enzyme-linked immunosorbent assay (BA-ELISA) method was developed and optimized for the determination of a weakly estrogenic isoflavone daidzein in serum, urine and Puerariae radix. Specific polyclonal antibody was produced against daidzein by immunization of rabbits with a conjugate of 7-O-(carboxymethyl)-daidzein and bovine serum albumin (BSA). The polyclonal antibody showed specific recognition of daidzein, while cross-reactivities to coumarin, 4-hydroxycoumarin, phenol, and other isoflavones such as puerarin and rutin were all lower than 1%. The linear range of daidzein calibration curve was 0.1-1000 ng mL−1. The detection limit was found to be 0.04 ng mL−1, and the intra-assay and inter-assay coefficients of variation were 7 and 16%, respectively. Human serum and urine samples were spiked with known amounts of daidzein and measured by the established BA-ELISA. Recoveries were between 91 and 107%. Daidzein in P. radix was determined by the BA-ELISA method and HPLC method, and the content of daidzein was determined to be 0.0219 and 0.0194%, respectively. The results indicated that there was a good agreement between the two methods. The established method is very useful for monitoring daidzein in biological samples and traditional Chinese medicine.  相似文献   

2.
Dan Wang 《Talanta》2010,82(1):432-436
A simple competitive enzyme-linked immunosorbent assay (cELISA) was established for rapid measurement of secretory immunoglobulin A (sIgA) in saliva. The method was based on competitive reaction between the immobilized IgA and free IgA in the solution for the limited amount of horseradish peroxidase-conjugated rabbit anti-human IgA. In comparison with the conventionally used Sandwich ELISA, the cELISA is simpler, low-cost, and shows better reproducibility since it is not affected by the variation of capture antibodies from different batches. The assay time was also significantly reduced from more than 5 h to less than 3 h. Different curve-fitting models were compared, among which the fully specified logit-log model gave the best results. The linear working range and limit of detection were found to be 0.1-100 μg mL−1 and 0.05 μg mL−1, respectively. Matrix effects of saliva samples were investigated and a reasonable range of dilution factors were proposed. The developed method offers a very practical approach for high-throughput measurement of sIgA in saliva samples.  相似文献   

3.
A specific polyclonal anti-norfloxacin antibody was obtained, and a sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed for determining trace amounts of norfloxacin in various waters. Good linearity was achieved in the range from 0.1 to 10 μg L−1. The average IC50 value was determined to be 2.2 μg L−1 and the limit of detection was 0.016 μg L−1 at a signal-to-noise ratio of 3 in phosphate-buffered saline buffer. Recoveries of norfloxacin at various spiking levels ranged from 74 to 105% in groundwater, surface water, treated and untreated wastewater samples, with relative standard deviations of 3–5%. The assay was applied for determining norfloxacin in municipal wastewater, surface water, and groundwater collected in a metropolis of China. Raw wastewater samples were only submitted to filtration and pH adjustment while the other water samples were pre-concentrated by solid phase extraction prior to the icELISA assay. Good agreement of the results obtained by the icELISA and liquid chromatography tandem mass spectrometry further confirmed the reliability and accuracy of the icELISA for rapid detection of norfloxacin in waters.  相似文献   

4.
Wang N  He M  Shi HC 《Analytica chimica acta》2007,590(2):224-231
In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 × 105. The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 104 CFU (colony forming units) L−1. The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method.  相似文献   

5.
Sensitive detection of pesticides is of utmost importance in environment and food analysis. Immunological methods are widely used to detect pesticides in agricultural and environmental samples wherein antibodies are employed against the target molecules. Accurate diagnosis depends on the affinity and specificity of the antibody preparation used, and high affinity antibodies are essential for the detection of very small amounts of pesticides. Enzyme linked immuno sorbent assay (ELISA) coupled with flow injection analysis (FIA) technique provides a very high sensitivity with high throughput of analyses. Automation of this analysis scheme ensures precise detection with high accuracy. The present development aims at providing a user-friendly system for achieving this objective. It employs a 8952 microcontroller for precise flow of reagents, samples, substrate and conjugates used for analysis to be passed through an immobilized antibody column at predetermined time. With the sequence and flow control of buffers used, it also provides the option for reuse of the immobilized antibody column. The system is flexible to accommodate multiple sequences up to a maximum of 99 steps. It is customizable for different flow ELISA applications. It can control up to eight solenoid valves (dc 24 V) and two peristaltic pumps and has one 12 bit analog channel for data acquisition. With the serial interface port, the system provides convenient means for data acquisition into the computer. The system has been successfully tested for immuno analysis of organophosphorous pesticide methyl parathion.  相似文献   

6.
In this study, a panel of haptens was synthesized for immunoconjugate preparation, and several haptens for heterologous tracer conjugates were also prepared. A highly sensitive polyclonal antibody against the organophosphorus insecticide phosmet was obtained and competitive direct enzyme-linked immunosorbent assays (cd-ELISA) for this pesticide were developed. In the cd-ELISA, the limit of detection (IC15) was 0.6 μg kg−1 and the sensitivity (IC50) was 20 μg kg−1. The suitability of the ELISA for pesticide quantification in peach, apple, orange juice, and apple juice was also studied. Good accuracy and precision were obtained with mean recoveries between 78% and 102.3% and mean coefficients of variation below 13.63%. Validation of the ELISA was conducted by high-performance liquid chromatography. The correlation between the data obtained using the microwell assay and the high-performance liquid chromatography was good (R 2 = 0.9849). The developed immunoassay methods were suitable for the rapid quantitative or qualitative determination of phosmet in food samples.  相似文献   

7.
Yan J  Mi JQ  He JT  Guo ZQ  Zhao MP  Chang WB 《Talanta》2005,66(4):1005-1011
Papaverine (1-(3,4-dimethoxybenzyl)-6,7-dimethoxyisoquinoline, PAP) is a member of the benzylisoquinoline sub-group of the opium alkaloids. It has been widely used for treating diseases like pulmonary arterial embolism and renal or biliary colic. In this paper, a specific conjugate of mono-demethylated papaverine-O-carboxylmethyl ether (MDMPAP-O-CME) and bovine serum albumin (BSA) was synthesized and used as the complete antigen (PAP-BSA), with which we successfully obtained a high-titer anti-PAP polyclonal antibody (pAb) by immunization of rabbits. The anti-PAP pAb showed high affinity to papaverine with an affinity constant (Kaff) of 7.3 × 107 L/mol. With this antibody, we established a sensitive immunochemical method for the determination of papaverine based on indirect competitive enzyme-linked immunosorbent assay (ELISA). The optimal concentrations of the coated antigen (PAP-OVA) and purified pAb used in the ELISA were 5 and 1.2 μg/mL, respectively. The cross reactivity of other benzylisoquinoline derived substances, including 1-(3,4-dihydroxybenzyl)-7-hydroxy-6-methoxy-isoquinoline (6-methoxy-papaveroline, MPAPO), morphine (MP) and codeine (CD) were all lower than 1%. The linear range of the calibration curve was 0.1-1000 ng/mL. Normal human serum samples were spiked with known amount of papaverine and measured by the ELISA. Recoveries were between 102% and 105%. Papaverine content in a commercial papaverine hydrochloride injection sample was also determined using the established ELISA. Compared with the results given by the control experiment of HPLC, the recoveries of ELISA to detect injection samples were 102-110%. The limits of detection for synthetic serum samples and injection samples of papaverine hydrochloride were 0.25 and 0.06 ng/mL, respectively.  相似文献   

8.
Development of an enzyme-linked immunosorbent assay for pentachlorophenol   总被引:5,自引:0,他引:5  
Pentachlorophenol (PCP) is a hazardous pollutant with toxicity and potential carcinogenic properties being a serious threat to the environment. In this work, the development of an immunoassay for PCP is presented. A hapten was synthesised and conjugated to protein for rabbit immunisation. Three polyclonal antibodies were obtained and the best results were achieved in the antibody-coated format using antiserum R3. Calibration range was 0.3–30.5 ng ml−1, with an average I50 value of 2.9 ng ml−1 and a detection limit of 0.1 ng ml−1. The specificity of the assay was tested against PCP structurally related compounds. The method is highly specific for PCP and shows low cross-reactivity (CR) for chlorine-containing phenols, nitrophenols, benzenic and piridinic compounds. The good recoveries achieved with different water samples indicate that this assay can be a good alternative method for the determination of PCP in this kind of samples.  相似文献   

9.
Pasquet C  Vulliet E 《Talanta》2011,85(5):2492-2497
Among the wide range of substances discharged continuously in the environment, alkylphenols became a major focus of environmental research in the last decades, as it was found that they possess endocrine disrupting properties. Knowledge about the occurrence and levels of alkylphenols in environment is critical for the risk assessment of these compounds on both ecosystem and human health. However, the analysis of traces of alkylphenols in environmental matrices is a very difficult task, and the suitable methods involve generally an extraction followed by an extensive sample clean-up before detection, steps often time-consuming and costly.In order to reduce the analysis time, obtain a high throughput of analysis and thus improve work efficiency, the objective of the present study is to investigate the use of immunochemical technique (ELISA) for the determination of nonylphenol and octylphenol in soils and various kinds of water. To our knowledge, this is the first time that the determination of alkylphenols in soil using immunoassay technique is described. A methodology is developed, based on the combination of a single preparation step and the use of a simply ELISA kit. The performances of the method are compared with LC-MS/MS, considered as reference. The developed procedure offers the sensitivity and selectivity necessary for the detection of the target alkylphenols in the ng/g or ng/L range, and is successfully applied to the analysis of several samples. Results indicate that alkylphenols are quantified with concentrations in the same order than LC-MS/MS, meaning that ELISA may be useful not only in screening the samples and get a positive/negative response, but also it allows a good approximation of the concentrations.  相似文献   

10.
A polyclonal antibody against ochratoxin A (OTA) was produced from rabbits immunized with the OTA–BSA conjugate. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a membrane-base colloidal gold immunoassay in flow-through format were developed for the rapid detection of OTA in various food matrices. In the cdELISA, the concentration causing 50% inhibition was 0.07 ng mL−1, and the effects of different chemical conditions (ionic strength, pH value, and organic solvent) were studied. The sensitivity of the assay was higher than those previously reported. A simple, rapid, and efficient extraction method was developed and 74–110% recoveries of spiked samples were obtained. Fifty percent methanol extracts of some food samples such as barley, wheat, oat, corn, rice, and raisins could be analyzed directly by immunoassay after dilution in PBS; grape juice and beer samples could be analyzed directly after dilution with PBS; for coffee samples, a more complex method was used to remove the matrix effect effectively. Membrane-based colloidal gold immunoassays had a visual detection limit of 1.0 ng mL−1 for OTA with a detection time of less than 10 min. For the validation of the cdELISA and membrane-based colloidal gold immunoassay, samples were analyzed by high-performance liquid chromatography. The correlation between data obtained using the microwell assay and HPLC was good (R 2 = 0.984). The developed immunoassay methods are suitable for the rapid quantitative or qualitative determination of OTA in food samples.  相似文献   

11.
分别将酮洛芬与牛血清白蛋白(BSA)及卵清蛋白(OVA)偶联制得免疫原和包被原,经过免疫新西兰白兔制备多克隆抗体,抗体经纯化后效价为1:128000。使用自制的抗体,建立了测定酮洛芬的间接竞争酶联免疫吸附(ic-ELISA)新方法。ic-ELISA的线性范围为0.010~10.0μg/L,IC50为0.235μg/L,最低检测限为0.0040μg/L,线性回归方程为y=-22.97ρ+104.5(R2=0.980),与布洛芬、双氯酚酸的交叉反应率均小于4%,方法可用于水体中酮洛芬的检测。  相似文献   

12.
A flow-based enzyme-linked immunosorbent assay (ELISA) on a polydimethylsiloxane (PDMS) microchip has been developed for the rapid determination of immunoglobulin A (IgA). The analytical principle of this integrated method is the same as the conventional sandwich-type ELISA. A primary antibody (anti-IgA) was adsorbed on the surface of a PDMS microchannel, and then an antigen (IgA) and a secondary antibody (anti-IgA HRP labeled) were reacted successively. The resulting antigen-antibody complex, fixed on the surface of the microchannel, was detected using Amplex® Red and a fluorescent imaging system. The calibration curve of the IgA standard solution was linear in the range of 0-50 ng/mL at the flow rate of 10 μL/min. This flow rate corresponds to the reaction time of 4.8 s. Compared to the conventional assay on a 96-well microtiter plate, the present assay on the microchip dramatically shortened the reaction time necessary for the enzyme-substrate reaction from 30 min to 4.8 s, i.e., to 1/375. The amounts of the reagent and sample were also reduced to 1/100 compared to the 96-well microtiter plate.  相似文献   

13.
The use of Sudan I as an additive in food products has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific monoclonal antibody (mAb)-based indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I in food samples was developed. The hapten derivative with a three-carbon-atom length of carboxylic spacer at the azobound para-position was synthesized and coupled to carrier proteins. The hapten-bovine serum albumin (BSA) conjugate was used as an immunogen, while the hapten-ovalbumin (OVA) conjugate was applied as a coating antigen. The mAb against Sudan I was produced by hybridoma technique and the corresponding ELISA was characterized in terms of sensitivity, specificity, precision and accuracy. At optimal experimental conditions, the standard curve was constructed in concentrations of 0.1-100 ng mL−1. The values of IC50 for nine standard curves were in the range of 1.1-2.0 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.07-0.14 ng mL−1. The cross-reactivity values of the mAb with Sudan II, III and IV were 9.5%, 33.9% and 0.95%; no cross-reactivity was found with other six edible colorants: Lemon yellow, Bright blue, Indigotin, Kermes, Amarant and Sunset yellow, indicating the assay displays not only high sensitivity but also high specificity as well. The organic solvent effect on the assay was tested. It was observed that the ELISA was tolerated to 30% of methanol and 10% of acetonitrile without significant loss of IC50 value. Six food samples were spiked with Sudan I and the methanolic extracts after appropriate dilution were analyzed by ELISA. Acceptable recovery rates of 88.2-110.5% and coefficients of variation of 2.5-17.4% were obtained. The ELISA for nine spiked samples was confirmed by high-performance liquid chromatography (HPLC) with a high correlation coefficient of 0.9840 (n = 9). The mAb-based ELISA proven to be a feasible quantitative/screening method for Sudan I analysis in food samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput and low expense.  相似文献   

14.
Estrone has been identified as a potential endocrine-disrupting chemical (EDC). To facilitate its analysis, a highly selective and sensitive enzyme-linked immunosorbent assay (ELISA) method with a simple solid-phase extraction (SPE) for analysis of estrone in aquatic environments has been developed. The specific polyclonal antibody was produced against a conjugate of estrone-3-hemisuccinate and keyhole limpet hemocyanin (KLH). The obtained ELISA showed specific recognition of estrone, without cross-reactions for three other major estrogenic compounds (17β-estradiol, estriol, and 17α-ethynylestradiol) commonly found in water. The ELISA had a limit of detection of 0.14 μg/l estrone in water. Combining a SPE method to extract and pre-concentrate estrone from water samples and ELISA to specifically quantify estrone content, the SPE-ELISA can detect estrone down to 1.25 ng/l level in water. Good recovery with spiked river water was obtained with this SPE-ELISA method. The developed SPE-ELISA system was applied to analyze the real influent and effluent samples of sewage treatment plant in Penrith (Australia) and the results correlated well with those obtained using GC and HPLC methods. The developed SPE-ELISA method is capable of being applied for the specific detection and routine monitoring of estrone in environmental water samples.  相似文献   

15.
A new method describing direct attachment of carboxylated haptens on a polystyrene support, using 3-aminopropyltriethoxysilane (3-APTES) as a linker, is reported. The hapten coated polystyrene support showed excellent stability as a function of the buffer pH and reaction time, and was successfully used to demonstrate its application in enzyme-linked immunosorbent assay (ELISA).  相似文献   

16.
Method validation was conducted for an enzyme-linked immunosorbent assay (ELISA) for the determination of domoic acid (DA) toxins, known to give amnesic shellfish poisoning (ASP) symptoms, in shellfish. The calibration curve range of the assay is approximately 10-260 pg/mL, with a dynamic working range for DA toxins in shellfish from 0.01 to at least 250 mg/kg. The ASP ELISA showed no significant cross-reactivity to structural analogs, and proved to be robust to deliberate alterations of the optimal running conditions. The shellfish matrix effects observed with mussels, oysters, and scallops were eliminated by diluting shellfish extracts 1:200 prior to analysis, leading to a limit of detection at 0.003 mg/kg. Thirteen blank shellfish homogenates were spiked with certified mussel material containing DA to levels in the range of 0.1-25 mg DA/kg, and analyzed in quadruplicate on 3 different days. The relative standard deviation (RSD) under intra-assay repeatability conditions ranged from 6.5 to 13.1%, and under interassay repeatability conditions the RSD ranged from 5.7 to 13.4%, with a mean value of 9.3%. The recoveries ranged from 85.5 to 106.6%, with a mean recovery of 102.2%. A method comparison was conducted with liquid chromatography with ultraviolet detection, using naturally contaminated scallop samples (n = 27) with DA levels at 0-244 mg/kg. The overall correlation coefficient was 0.960 and the slope of the regression was 1.218, indicating a good agreement between the methods.  相似文献   

17.
Soybean protein has long been recognized as a source of dietary allergens for humans and animals with β-conglycinin being the major allergen. This paper presents a sandwich enzyme-linked immunosorbent assay (ELISA) that allows for the detection of trace amount of β-conglycinin in soybean and soybean products. In the sandwich ELISA, mouse anti-β-conglycinin monoclonal antibody (Mab 5C5) was used as coating antibody, and rabbit anti-β-conglycinin polyclonal antibody (Pab) was used as secondary antibody. The assay showed high specificity for β-conglycinin with minimum cross-reactions with other soy proteins. The practical working range for the determination of β-conglycinin using the developed assay was 3–100 ng mL−1 and the limit of determination (LOD) was 1.63 ng mL−1. The recoveries of β-conglycinin in spiked soybean samples were between 88.1% and 106.6% with relative standard deviation less than 8.9% (intra-day) and 13.1% (inter-day). The developed method was used to analyze 469 soybean seed samples from different sources as well as five soybean products treated with different processing techniques. The data showed that the concentration of β-conglycinin decreased significantly after processing, especially for soybean protein isolation, where the concentration of β-conglycinin dropped to nearly zero. The assay provides a specific and sensitive method for the screening of β-conglycinin and allows for further investigation into hypersensitive mechanisms of soybean proteins and development of soybean processing techniques to reduce their negative effects.  相似文献   

18.
4-Nonylphenol (NP) and octylphenol (OP) were measured by direct ELISA in both laboratory-fortified and surface water samples collected monthly from 10 rivers. In this procedure, samples were concentrated by solid phase extraction (SPE) using Lichrolut RP-18 sorbent with good recoveries obtained for both LC-MS and ELISA, giving a low level of detection (LOD) at the range of low μg L−1 and good reproducibility. Analysis of 40 surface water samples demonstrated that the ELISA may be a useful screening tool for the determination of the alkylphenols in surface water matrices. The concentration of NP and OP in surface waters ranged from 0.11 to 6.58 μg L−1. A good correlation of results obtained by ELISA and LC-MS within the concentration range of 0.08-6.86 μg L−1 was found in the river samples [R2 = 0.924, n = 39]. The influence of various factors on assay determination was also discussed.  相似文献   

19.
Plumbagin (PL; 5-hydroxy-2-methyl-1,4-naphthoquinone) is a natural compound mainly isolated from Plumbago zeylanica. This plant is distributed in Southeast Asia, and well known as Ayurvedic medicine in India for its medicinal properties. PL has been shown to have various pharmacological activities. We have successfully prepared monoclonal antibodies against PL, and developed an enzyme-linked immunosorbent assay (ELISA) system for determination of PL. 3-(5-Hydroxy-2-methyl-1,4-naphthoquinone-3-yl) propanoic acid was synthesized and purified to prepare PL-bovine serum albumin conjugate (PL-BSA), which was used as an immunogen. PL-BSA conjugate was administered into BALB/c male mice for production of monoclonal antibodies against PL. The monoclonal antibody against PL which is secreted from established hybridoma cell line 3A3 (MAb 3A3) has been proven to have highly-specific to PL resulting from cross-reactivities test. The range for calibration of PL by ELISA was 0.2-25 μg mL−1. Based on validation analysis, this analytical method by ELISA is a precise, accurate, and sensitive method for the determination of PL in plant.  相似文献   

20.
The use of olaquindox (OLA) as an additive in animal feedstuffs has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for determination of OLA in animal feed samples was developed. OLA was activated by NN-carbonyldiimidazole and coupled with bovine serum albumin (BSA) and ovalbumin (OVA). It was found that the sensitivity and specificity of the two antisera were very similar, with the IC50 values of 16 ng mL−1 and 19 ng mL−1, respectively. Cross-reactivity was less than 35% for four structurally related compounds and no recognition of five other antibiotics was observed. The better antiserum I was selected for further experiments, for example testing stability, solvent effect, accuracy, and precision. The IC50 value for eight standard curves was in the range 12–18 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.31 ± 0.11 ng mL−1. The ELISA tolerated 5% methanol without significant influence on IC50 value. The recoveries of spiked OLA in five different animal feed types including auxin, pig complex feed, fish complex feed, broiler concentrated feed, and pig premix feed were in the range 88.3–119.0% and the intra-assay relative standard deviation (RSD) was within 4.7–33.5% (n = 3). The ELISA for unspiked feed samples was confirmed by high-performance liquid chromatography (HPLC), with a high correlation coefficient of 0.9862 (n = 5). The proposed ELISA could be a feasible quantitative/screening method for OLA analysis in feed samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput, and low expense. Figure Polyclonal antibody based ELISA for detection of olaquindox  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号