首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Indirect ultraviolet detection was conducted in ultraviolet‐absorption‐agent‐added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li+, Na+, K+, and NH4+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography‐indirect ultraviolet detection. The successful separation and detection of Li+, Na+, K+, and NH4+ within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded.  相似文献   

2.
The behavior of acids (citric acid, nitric acid, oxalic acid, tartaric acid) as a mobile phase and imidazolium ionic liquids (the bromides, tetrafluoroborates and hexafluorophosphates of 1‐ethyl, 1‐butyl, and 1‐hexyl‐3‐methylimidazolium) as additives in ion exchange chromatography for cations (Na+, K+, Mg2+, Ca2+) separation were studied. The results showed that nitric acid and 1‐hexyl‐3‐methyl‐imidazolium hexafluorophosphate offered the most interesting features in the separation of cations, such as lower retention time and better resolution. The selected optimal conditions were achieved by adding 0.10 mM 1‐hexyl‐3‐methyl‐imidazolium hexafluorophosphate in 4.0 mM HNO3 mobile phase for the separation of four cations with the flow rate of 0.9 mL/min at room temperature (25°C). The linear regression equations of Na+, K+, Mg2+, Ca2+ were = 4.4763c  + 0.0209, = 3.8903c  – 0.0087, = 6.3974c  – 0.0173, and = 7.601c  – 0.0339 and the limits of detection of Na+, K+, Mg2+, Ca2+ were 0.296, 4.98, 0.0970, and 1.22 μg/L, respectively. In this work, four cations in samples were successfully detected.  相似文献   

3.
Separation and determination of some common metal ions was achieved with methyl 3‐amino‐3‐(pyridin‐3‐yl)propanoate dihydrochloride (MAPP) as an ion‐pairing reagent and pyridine as a detectable counter‐ion for indirect UV detection at 254 nm. The effects of the complexing reagent and chromophore concentrations, applied voltage, and organic solvent content on the separation were investigated. The optimized separation was carried out in a running electrolyte containing 16 mM MAPP and 20 mM pyridine at pH 4.0 and was successfully applied to the qualitative and quantitative analysis of Li+, Na+, Mg2+, Ca2+, Ba2+, Ni2+, and Zn2+ in pharmaceutical vitamin preparations and various water samples.  相似文献   

4.
The potentialities of new ionic liquids (ILs) based on choline were evaluated as an electrophoretic medium in capillary electrophoresis for the analysis of alkaline and alkaline earth cations (Li+, K+, Na+, Cs+, Mg2+, Ba2+, Ca2+, and Sr2+) with indirect UV detection. Two types of capillaries were tested: an untreated fused silica and fused silica coated with a film of polyvinylalcohol. The coated capillary proved to be the best adapted for the metal ions studied. Moreover, it appeared that the nature of the ionic liquid anion influenced the baseline stability, and the bis(trifluoromethylsulfonyl) imide (NTf2 ) anion seemed to be the most efficient. These preliminary studies led us to synthesize a new ionic liquid, 2-hydroxy-N,N,N-trimethyl-1-phenylethanaminium NTf2 (phenylcholine NTf2). This liquid was able to act as the running electrolyte and probe, generating the background signal in indirect UV light and consequently simplifying the electrophoretic medium. Excellent baseline stability, good reproducibility, as well as good sensitivity of detection were obtained with this new ionic liquid. Thus, 510,000 plates/meter for Li+ with 40 mM IL were successfully obtained. The optimal concentration of IL was 20 mM with a detection limit ranging from 28 μg L−1 for Li+ to 1,000 μg L−1 for Cs+. This method (phenylcholine NTf2 with polyvinylalcohol capillary) was applied to analyze different commercial source and mineral waters. Finally, the potentiality of this ionic liquid in nonaqueous capillary electrophoresis was explored. The use of phenylcholine NTf2 with a fused silica capillary, in pure methanol medium and in the presence of acetic acid, made it possible to obtain separation selectivity different from that obtained in aqueous medium.  相似文献   

5.
A method of simultaneous separation and indirect ultraviolet detection of different valence iron ions Fe2+ and Fe3+ by using ionic liquids as mobile phase additives and ultraviolet absorption reagents on a cation exchange column functionalized with carboxylic acid group was developed. The effects of ionic liquids, organic acids, detection wavelength, etc. on separation and detection of Fe2+ and Fe3+ were investigated and the mechanism was discussed. The pyridinium and imidazolium ionic liquids were not only ultraviolet absorption reagents of indirect ultraviolet detection but also effective components for separating Fe2+ and Fe3+. The separation and detection of Fe2+ and Fe3+ can be achieved using 0.5 mmol/L pyridinium ionic liquid?1.2 mmol/L methanesulfonic acid as the mobile phase. The determination of Fe2+ and Fe3+ had a good linear relationship in the concentration range of 1?100 mg/L. The limits of detection of Fe2+ and Fe3+ were 0.12 and 0.09 mg/L, respectively. This method was applied to the actual sample detection in the field of medical analysis. The spiked recoveries were between 97.3 and 99.5%, and the relative standard deviations were less than 0.6%. The method is simple, accurate, and reliable, and is an analytical method with universal and practical value.  相似文献   

6.
A hybrid monolithic column with sulfonate functionality was successfully prepared for the simultaneous separation of common inorganic cations in ion‐exchange chromatographic mode through a simple and easy single‐step preparation method. The strong cation‐exchange moieties were provided directly from allylsulfonate, which worked as an organic monomer in the single‐step reaction. Inorganic cations (Li+, Na+, K+, NH4+, Cs+, Rb+, Mg2+, Ca2+, and Sr2+) were separated satisfactorily by using CuSO4 as the eluent with indirect UV detection. The allysulfonate hybrid monolith showed a better performance in terms of speed and pressure drop than the capillary packed column. The number of theoretical plates achieved was 19 017 plates/m (in the case of NH4+ as the analyte). The relative standard deviations (n = 6) of both retention time and peak height were less than 1.96% for all the analyte cations. The allysulfonate hybrid monolithic column was successfully applied for the rapid and simultaneous separation of inorganic cations in groundwater and the effluent of onsite domestic wastewater treatment system.  相似文献   

7.
Chao Guan  Hong Yu 《中国化学快报》2015,26(11):1371-1375
A method of hydrophilic interaction liquid chromatography with indirect ultraviolet detection was developed to determine three pyrrolidinium ionic liquid cations, i.e. N-methyl-N-ethyl pyrrolidinium cation ([MEPy]+), N-methyl-N-propyl pyrrolidinium cation ([MPPy]+) and N-methyl-N-butyl pyrrolidinium cation ([MBPy]+). Chromatographic separation was achieved on a hydrophilic column using imidazolium ionic liquids and organic solvents as the mobile phase. The effects of the background ultraviolet absorption reagents, the imidazolium ionic liquids, detection wavelength, organic solvents, column temperature and the pH value of the mobile phase on the separation and determination of pyrrolidinium cations were investigated and the retention behaviors in hydrophilic interaction chromatography were discussed. The optimized chromatographic conditions were selected. Under the optimal conditions, the detection limits (S/N = 3) for [MEPy]+, [MPPy]+ and [MBPy]+ were 0.59, 0.53 and 0.46 mg/L, respectively. The method has been successfully applied to the determination of the three ionic liquids synthesized in our chemistry laboratory. This research results may improve the analytical method of ionic liquid cations.  相似文献   

8.
Five new lipophilic dicarboxylic acids with systematic structural variation in the bridge which joins the two lipophilic carboxylic acid units have been synthesized. Potentiometric equilibrium measurements of hydrogen ion concentrations have been employed to determine the protonation constants for these lipophilic di-ionizable acyclic ligands in 90% methanol-10% water (v/v) at 25.0 °C and an ionic strength of 0.10 M and the stability constants for their complexes with Mg2+, Ca2+, and Sr2+. Although all five ligands exhibit the highest stability constants for Ca2+, the magnitude of the differences between the stability constants for complexation of Ca2+ versus Mg2+ or Sr2+ is found to vary widely depending upon the identity of the bridging unit which joins the two carboxylic acid end groups.  相似文献   

9.
The modification of silica gel with aluminium and zirconium can be used for the preparation of advanced silica-based cation-exchange stationary phases for use in ion chromatography with conductimetric detection (IC-CD) for cations. Silica gels modified with aluminium (Al-silica) and zirconium (Zr-silica) act as cation-exchangers under strongly acidic conditions. Highly sensitive indirect conductimetric detection and excellently simultaneous separation for common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) can be achieved on the Al-silica and Zr-silica columns in IC-CD by using acidic eluents containing 15-crown-5 (1,3,7,10,13-pentaoxacyclopentadecane). The Al-silica and Zr-silica can also be applied successfully as cation-exchange stationary phases in ion-exclusion chromatography for the separation of various aliphatic and benzenecarboxylic acids.  相似文献   

10.
《Analytical letters》2012,45(5):922-931
An investigation into the determination of four imidazolium ionic liquid cations by ion chromatography using a carboxyl acid cation exchange column and direct conductivity detection was carried out. This research has developed a simple, selective, and accurate ion chromatographic method for separation of imidazolium ionic liquid cations. Detection limits (S/N = 3) for the cations were 3.2–24.3 mg/L. Relative standard deviations (RSD, n = 5) for peak areas were less than 1.6%. The method has been successfully applied to the determination of two ionic liquids synthesized by organic chemistry lab.  相似文献   

11.
董影杰  于泓  王婧菲  黄旭 《分析化学》2011,39(8):1251-1255
建立了四甲基铵根离子的反相高效液相色谱-间接紫外检测分析法.以ZORBAX ODS反相色谱柱为分离柱,采用间接紫外检测方法,考察了紫外检测波长和离子液体+有机溶剂(乙腈、甲醇)流动相对分离和测定四甲基铵根离子的影响.最佳色谱条件为:以80% 1-乙基-3-甲基咪唑四氟硼酸盐水溶液(0.5 mmol/L,乙酸调pH 3....  相似文献   

12.
Summary The batch removal ofCs+, Sr2+, Ca2+and Mg2+ions from aqueous solutions using synthetic zeolite A was investigated. The influence of the initial ion concentration, pH and temperature was studied. The obtained isotherm data have been correlated with Langumir, Freundlich, and Dubinin-Radushkevich(D-R) isotherm models. The effect of the temperature on the equilibrium distribution values has been utilized to evaluate the standard thermodynamic parameters such as free energy (DG), enthalpy (DH) and entropy (DS). Based on the D-R isotherm expression, the maximum ion-exchange capacity and the mean free energy of each studied ion has been determined. The selectivity sequence, deduced from the equilibrium isotherm data is: Sr2+>Ca2+>Mg2+>Cs+>Na+.</p> </p>  相似文献   

13.
《中国化学会会志》2018,65(6):726-734
A method was developed for the separation and detection of morpholinium ionic liquid cations by hydrophilic interaction column combined with indirect ultraviolet detection using imidazolium ionic liquids as ultraviolet absorbents in high‐performance liquid chromatography. The effects of the ultraviolet absorbents, organic solvents, and the pH value of the aqueous solution in the mobile phase for the determination of morpholinium cations were investigated by using a hydrophilic column with carbamoyl group as the analytical column. The retention and detection behavior of morpholinium cations was discussed. The suitable chromatographic conditions were 0.8 mmol/L 1‐ethyl‐3‐methyl‐imidazolium tetrafluoroborate aqueous solution (pH 3.5 adjusted with acetic acid)/acetonitrile (45/55, v/v) as the mobile phase and a detection wavelength of 210 nm. Under these conditions, the baseline separation of N‐methyl‐N‐ethyl‐morpholinium cation ([MEMo]+) and N‐methyl‐N‐propyl‐morpholinium cation ([MPMo]+) was successfully achieved in 15 min. The detection limits of [MEMo]+ and [MPMo]+ were 0.595 and 0.531 mg/L, respectively. Relative standard deviations were less than 0.2%. This method has been successfully applied to the analysis of morpholinium ionic liquid samples synthesized in chemical laboratories, which is simple, reliable, and practical.  相似文献   

14.
The thermodynamic measurements was carried out to study the selectivity of cation exchange resin Amberlite IR-120 in protonated form with respect to Mg2+, Ca2+, Sr2+ and Ba2+ ions in solution. The equilibrium constant K was calculated using the activity coefficients of ions in solution as well as in the resin. The K values calculated for the reacting systems increase with temperature that suggests the endothermic exchange reactions with estimated enthalpy values of 38.8, 20.6, 8.45, and 7.24 kJ mol−1, respectively. On the basis of calculated parameters, the selectivity of ion exchange resin with respect to various bivalent ions in the solution was predicted. The method used in our experimental work provides a basis for characterization of ion exchange resins, which can be promising materials for efficient separation of ions from industrial waste effluents.  相似文献   

15.
Summary A pure silica gel (Pia Seed 5S-60-SIL), synthesized by the hydrolysis of pure tetraethoxysilane [Si(OCH2CH3)4], was applied as a cation-exchange stationary phase in ion chromatography with indirect photometric detection for common mono-and divalent cations (Li+, Na+, NH4 +, K+, Mg2+, and Ca2+) using various protonated aromatic monoamines (tyramine [4-(2-aminethyl) phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine) as eluet ions. When using 0.75 mM tyramine-0.25 mM oxalic acid-1.5 mM 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) at pH 5.0 as the eluent, excellent simultaneous separation and highly sensitive detection at 275 nm for these mono-and divalent cations were achieved on the Pia Seed 5S-60-SIL column (150×4.6 mm I.D.) in 20 min.  相似文献   

16.
The complexation reactions between Mg2+, Ca2+, Sr2+ and Ba2+ cations with the macrocyclic ligand, 18-Crown-6 (l8C6) in water–methanol (MeOH) binary systems as well as the complexation reactions between Ca2+ and Sr2+ cations with 18C6 in water–ethanol (EtOH) binary mixtures have been studied at different temperatures using conductometric method. The conductance data show that the stoichiometry of all the complexes is 1:1. It was found that the stability of 18C6 complexes with Mg2+, Ca2+, Sr2+ and Ba2+ cations is sensitive to solvent composition and in all cases, a non-linear behaviour was observed for the variation of log K f of the complexes versus the composition of the mixed solvents. In some cases, the stability order is changed with changing the composition of the mixed solvents. The selectivity order of 18C6 for the metal cations in pure methanol is: Ba2+ > Sr2+ > Ca2+ > Mg2+. The values of thermodynamic parameters (Δ H c ° and Δ S c °) for formation of 18C6–Mg2+, 18C6–Ca2+, 18C6–Sr2+ and 18C6–Ba2+complexes were obtained from temperature dependence of the stability constants. The obtained results show that the values of (Δ H c ° and Δ S c °) for formation of these complexes are quite sensitive to the nature and composition of the mixed solvent, but they do not vary monotonically with the solvent composition.This revised version was published online in July 2005 with a corrected issue number.  相似文献   

17.
An investigation was carried out into the fast determination of five homologue imidazolium cations in ionic liquids by ion chromatography using a cation-exchange column and direct conductivity detection. Ethylenediamine, complex organic acid (citric acid, oxalic acid and tartaric acid) and organic modifiers (acetonitrile) were used as mobile phase. The influences of the eluent types, eluent concentration, eluent pH and column temperature on separation of the cations were discussed. Simultaneous separation and determination of the five homologue imidazolium cations in ionic liquids were achieved under an optimum condition. The optimized mobile phase was consisted of 0.25 mmol L?1 ethylenediamine + 0.5 mmol L?1 citric acid + 3% acetonitrile (v/v) (pH 4.1), set at a flow rate of 1.0 mL min?1. The column temperature was 40 °C and detection limits were obtained in the range of 1.1–45.6 mg L?1. The relative standard deviations of the chromatographic peak areas for the cations were <3.0% (n = 5). This method was successfully applied to separate imidazolium cations in ionic liquids produced by organic synthesis. The recoveries of spiked components were 92.5–101.9%.  相似文献   

18.
19.
Indirect ultraviolet detection method is a simple and effective method for the determination of ionic liquid cations without ultraviolet absorption group. This paper focused on the influence of different background ultraviolet absorption reagents on the determination of piperidinium ionic liquid cations by ion pair chromatography with indirect ultraviolet detection. Ultraviolet absorption reagents are divided into cationic (4-aminophenol hydrochloride, 1-ethyl-3-methylimidazolium tetrafluoroborate, and N-ethylpyridinium tetrafluoroborate), anionic (potassium biphthalate and 5-sulfosalicylic acid), and amphiprotic (p-aminobenzoic acid). The results showed that piperidinium cations can be separated and detected by cationic and anionic ultraviolet absorption reagents. In general, the cationic ultraviolet absorption reagents have the best effect for separation and detection of the piperidinium cations by ion pair chromatography with indirect ultraviolet detection.  相似文献   

20.
Summary Pure silica gel (Pia Seed 5S-60-SIL) has been investigated as a cation-exchange stationary phase for ion chromatography of common monovalent and divalent cations (Li+, Na+, NH4+, K+, Mg2+, and Ca2+) with conductimetric detection; dilute oxalic acid (0.05 mm oxalic acid, pH 4.1, to 1 mm oxalic acid, pH 3.0) was used as mobile phase. The Pia Seed 5S-60-SIL silica gel acted as a cation-exchange stationary phase for these cations when 0.2 mm oxalic acid at pH 3.6 was used as the mobile phase. Excellent simultaneous separation and highly sensitive indirect conductimetric detection of these cations were achieved in 20 min on a 150 mm × 4.6 mm i.d. Pia Seed 5S-60-SIL silica gel column with 0.2 mm oxalic acid containing 4 mm 18-crown-6 (1,4,7,10,13,16-hexaoxacycloctadecane), pH 3.7, as mobile phase (detection limits (signal-to-noise ratio, 3, injection volume, 20 L), were 0.15 m for Li+, 0.16 m for Na+, 0.21 m for NH4+, 1.0 m for K+, 0.17 m for Mg2+, and 0.25 m for Ca2+). The proposed IC–CD method was successfully applied to the separation and detection of major cations (Na+, NH4+, K+, Mg2+, and Ca2+) in rain and river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏