首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
An autonomous DNA nanomachine based on rolling circle amplification (RCA)-bridged two-stage exonuclease III (Exo III)-induced recycling amplification (Exo III-RCA-Exo III) was developed for label-free and highly sensitive homogeneous multi-amplified detection of DNA combined with sensitive fluorescence detection technique. According to the configuration, the analysis of DNA is accomplished by recognizing the target to a unlabeled molecular beacon (UMB) that integrates target-binding and signal transducer within one multifunctional design, followed by the target-binding of UMB in duplex DNA removed stepwise by Exo III accompanied by the releasing of target DNA for the successive hybridization and cleavage process and autonomous generation of the primer that initiate RCA process with a rational designed padlock DNA. The RCA products containing thousands of repeated catalytic sequences catalytically hybridize with a hairpin reporter probe that includes a “caged” inactive G-quadruplex sequence (HGP) and were then detected by Exo III-assisted recycling amplification, liberating the active G-quadruplex and generating remarkable ZnPPIX/G-quadruplex fluorescence signals with the help of zinc(II)-protoporphyrin IX (ZnPPIX). The proposed strategy showed a wide dynamic range over 7 orders of magnitude with a low limit of detection of 0.51 aM. In addition, this designed protocol can discriminate mismatched DNA from perfectly matched target DNA, and holds a great potential for early diagnosis in gene-related diseases.  相似文献   

2.
Li N  Li J  Zhong W 《Electrophoresis》2008,29(2):424-432
Here we describe an assay which combines CE with rolling circle amplification (RCA) for sensitive DNA detection and quantification. RCA is an isothermal DNA replication technique that generates a long ssDNA with tandem repeats. It requires simpler temperature control in reaction and offers higher sequence specificity and greater quantitation capability compared to other amplification technologies. In this study, RCA amplified the DNA target via a circular template, and the product was digested into monomers for CE analysis. Less than 2 fmol of the DNA target could easily be detected using this RCA-CE assay and the assay has a dynamic range of two orders of magnitudes. Moreover, simultaneous detection of both the target DNA and the internal standard was achieved by designing two padlock probes with different sizes, which could significantly improve the quantification accuracy. The RCA-CE assay is easy to perform, readily adaptable for detection of multiple targets because of the high resolution power of CE, and is compatible with other applications employing RCA as a signal amplification tool. Additionally, this assay can be used with a capillary array system to perform sensitive, high-throughput genetic screening.  相似文献   

3.
Fei Y  Jin XY  Wu ZS  Zhang SB  Shen G  Yu RQ 《Analytica chimica acta》2011,691(1-2):95-102
In order to develop a highly sensitive and selective piezoelectric transducer for the detection of DNA, the bio-recognizing probe is for the first time designed by introducing a hairpin structure and a recognition site for EcoRI into an oligonucleotide sequence and signal amplifiers are prepared by modifying gold nanoparticles (GNPs) with biomolecules, deepening the application and understanding of biomaterials. The piezoelectric transducer is prepared by immobilizing designed hairpin recognition probe onto the quartz-crystal-microbalance (QCM). In the absence of target DNA, the hairpin probe is removed from the QCM surface after exposure to endonuclease, inhibiting the subsequent signaling reaction. In contrast, introduction of target DNA can open the hairpin probe due to the probe/target hybridization, dissociating the cleavable double-stranded portion. In this case, even if being treated with endonuclease, the integrated hairpin probe is maintained. Subsequent introduction of GNPs modified with detection probes that can hybridize to the terminal sequence of hairpin probe results in a many-folds increase of the frequency response. Utilizing the proposed transduction scheme, the reliable target DNA detection can be accomplished. The detection limit of 2 pM and dynamic response range for target DNA from 2 to 300 pM are obtained. Furthermore, single-base mismatched DNAs can be easily identified. The developed proof-of-principle of a novel piezoelectric transduction scheme is expected to establish a potential platform for the disease-associated mutation analysis and DNA hybridization detection in biotechnology and medical diagnostics.  相似文献   

4.
Unique base sequences derived from RNA of both infectious hematopoietic necrosis virus (IHNV) and infectious salmon anemia virus (ISAV) were detected and identified using a combination of surface-associated molecular padlock DNA probes (MPPs) and rolling circle amplification (RCA) in microcapillary tubes. DNA oligonucleotides with base sequences identical to RNA obtained from IHNV or ISAV were recognized by MPPs. Circularized MPPs were then captured on the inner surfaces of glass microcapillary tubes by immobilized DNA oligonucleotide primers. Extension of the immobilized primers by isothermal RCA produced DNA concatamers, which were labeled with fluorescent SYBR Green II nucleic acid stain, and measured by microfluorimetry. Molecular padlock probes, combined with this method of surface-associated isothermal RCA, exhibited high selectivity without the need for thermal cycling. This method is applicable to the design of low-power field sensors capable of multiplex detection of viral, bacterial, and protozoan pathogens within localized regions of microcapillary tubes.   相似文献   

5.
《Supramolecular Science》1998,5(5-6):733-735
A nonradioactive probe was utilized in dot-blot hybridization for the detection of infectious Epstein-Barr virus. A polymerase chain reaction PCR-generated oligonucleotide, a 121 bp segment was labeled with digoxigenin (DIG)-11-dUTP. The hybridization results were detected by using an alkaline phosphatase-conjugated antibody to DIG and the enzyme substrates. The DIG-EB DNA allowed the detection limit in 0.1 pg of DNA. The samples from fifteen patients with nasopharyneal cancer (NPC) were examined.  相似文献   

6.
Zhu N  Zhang A  He P  Fang Y 《The Analyst》2003,128(3):260-264
A novel, sensitive electrochemical DNA hybridization detection assay, using cadmium sulfide (CdS) nanoclusters as the oligonucleotide labeling tag, is described. The assay relies on the hybridization of the target DNA with the CdS nanocluster oligonucleotide DNA probe, followed by the dissolution of the CdS nanoclusters anchored on the hybrids and the indirect determination of the dissolved cadmium ions by sensitive anodic stripping voltammetry (ASV) at a mercury-coated glassy carbon electrode (GCE). The results showed that only a complementary sequence could form a double-stranded dsDNA-CdS with the DNA probe and give an obvious electrochemical response. A three-base mismatch sequence and non-complementary sequence had negligible response. The combination of the large number of cadmium ions released from each dsDNA hybrid with the remarkable sensitivity of the electrochemical stripping analysis for cadmium at mercury-film GCE allows detection at levels as low as 0.2 pmol L(-1) of the complementary sequence of DNA.  相似文献   

7.
Aberrant DNA methylation of CpG sites has been confirmed to be closely associated with carcinogenesis.Based on the hyperbranched rolling circle amplification(HRCA) and microarray techniques,a new method for qualitative detection of methylation was developed.In the present study,padlock probes hybridize the sample DNA at the methylation site to form a probe-DNA complex which is ligated and digested simultaneously by methylation specific enzymes.Only at the methylated CpG site is the padlock probe ligated successfully to form a circle template for the HRCA reaction.Utilizing the method of 3-dimensional polyacrylamide gel-based microarray,the HRCA product will be immobilized on the slide to form a DNA microarray,which can universally hybridize the Cy3-labeled oligonucleotide probe to detect the methylation status of CpG sites.To control the false positive signals,DNA ligase and temperature of ligation/digestion are optimized.Methylation status of four CpG sites located in P15,Ecadherin,hMLH1 and MGMT genes were analyzed successfully with this method and all the results were compatible with that of methylation-specific PCR.Our research proves that this method is simple and inexpensive,and could be applied as a high-throughput tool to qualitatively determine the methylation status of CpG sites.  相似文献   

8.
Cai H  Xu Y  Zhu N  He P  Fang Y 《The Analyst》2002,127(6):803-808
A novel, sensitive electrochemical DNA hybridization detection assay, using silver nanoparticles as the oligonucleotide labeling tag, is described. The assay relies on the hybridization of the target DNA with the silver nanoparticle-oligonucleotide DNA probe, followed by the release of the silver metal atoms anchored on the hybrids by oxidative metal dissolution and the indirect determination of the solubilized Ag(I) ions by anodic stripping voltammetry (ASV) at a carbon fiber ultramicroelectrode. The influence of the relevant experimental variables, including the surface coverage of the target oligonucleotide, the duration of the silver dissolution steps and the parameters of the electrochemical stripping measurement of the silver(I) ions, is examined and optimized. The combination of the remarkable sensitivity of the stripping metal analysis at the microelectrode with the large number of silver(I) ions released from each DNA hybrid allows detection at levels as low as 0.5 pmol L(-1) of the target oligonucleotides.  相似文献   

9.
An allele‐specific voltammetric genoassay for the detection of allele‐specific toll‐like receptor‐2 gene arg753gln polymorphism (TLR‐2) from polymerase chain reaction (PCR) amplified real samples was described in this study. Meldola blue (MDB), an intercalator molecule, was used as hybridization label. The wild‐type and mutant type oligonucleotide probes were immobilized onto disposable graphite electrode surfaces by covalent attachment method. The extent of hybridization between probe and target sequences was determined by using differential pulse voltammetry (DPV). As a result of the interaction between MDB and DNA at electrode surface, the MDB signal observed from probe sequence before hybridization and after hybridization with MM sequence is lower than that observed after hybridization with complementary sequence. The differences between the MDB reduction peaks obtained from probe modified, hybrid modified and MM modified electrode were used to detect TLR‐2 from PCR amplified real samples. The discrimination of homozygous and heterozygous alleles was also established by comparing the peak currents of MDB reduction signals. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.  相似文献   

10.
A two-probe tandem nucleic acid hybridization assay for detection of Staphylococcus aureus is presented. It is based on a europium(III) complex as a marker that has a long fluorescence lifetime, high quantum yield and can be easily conjugated to an oligonucleotide signaling probe. The amino-modified capture probe was associated with the signaling probe to form a two-probe tandem DNA pattern that is complementary to the target DNA. The method was optimized in terms of hybridization temperature, hybridization time and washing time. This resulted in good specificity and sensitivity when detecting such bacteria in food samples.
Figure
A europium complex as a long fluorescent lifetime marker was conjugated to an oligonucleotide. The amino-modified capture probe was associated with the signaling probe to form a two-probe tandem DNA pattern that is complementary to the target DNA. The results are shown that this method has good specificity and sensitivity.  相似文献   

11.
A new DNA hybridization analytical method using a microfluidic channel and a molecular beacon-based probe (MB-probe) is described. A stem-loop DNA oligonucleotide labeled with two fluorophores at the 5′ and 3′ termini (a donor dye, TET, and an acceptor dye, TAMRA, respectively) was used to carry out a fast and sensitive DNA analysis. The MB-probe utilized the specificity and selectivity of the DNA hairpin-type probe DNA to detect a specific target DNA of interest. The quenching of the fluorescence resonance energy transfer (FRET) signal between the two fluorophores, caused by the sequence-specific hybridization of the MB-probe and the target DNA, was used to detect a DNA hybridization reaction in a poly(dimethylsiloxane) (PDMS) microfluidic channel. The azoospermia gene, DYS 209, was used as the target DNA to demonstrate the applicability of the method. A simple syringe pumping system was used for quick and accurate analysis. The laminar flow along the channel could be easily controlled by the 3-D channel structure and flow speed. By injecting the MB-probe and target DNA solutions into a zigzag-shaped PDMS microfluidic channel, it was possible to detect their sequence-specific hybridization. Surface-enhanced Raman spectroscopy (SERS) was also used to provide complementary evidence of the DNA hybridization. Our data show that this technique is a promising real-time detection method for label-free DNA targets in the solution phase. Figure FRET-based DNA hybridization detection using a molecular beacon in a zigzag-shaped PDMS microfluidic channel  相似文献   

12.
A novel base-mismatched oligonucleotide assay method based on label-free electrochemical biosensor was developed, in which the L-cysteine (Cys)-dihydroartemisinin (DHA) complex was used as a new electroactive indicator. In DNA sensor, Cys-DHA complex was initially formed on electrode surface by cathodic scanning, and target oligonucleotide was conjugated with Cys-terminated DHA indicator through electrostatic interaction under optimal pH. The subsequent sequence assay was responsive to hybridization recognition, which target oligonucleotide was captured by the surface-anchored DNA/Cys-DHA probe. The electrochemical signals of biosensor before and after hybridization were compared basing the measurements of semi-derivative linear scan voltammetry (SDLSV) and electrochemical impedance spectroscopy (EIS). On the basis of signal amplification of electroactive indicator and specific recognition of DNA probe, five target oligonucleotides with different mismatched bases were assayed, and a detection limit reached 0.3 nM. Furthermore, atomic force microscopy (AFM) was used to visually characterize specific recognition spots of biosensor at nanoscale. This study demonstrated a new electroactive molecule-based, biomolecule-involved electroactive indicator and its application in recognition and detection of complementary and base-mismatched oligonucleotide.  相似文献   

13.
A chemiluminescent (CL) detection method has been developed for DNA hybridization. The assay relies on a sandwich-type DNA hybridization in which gold nanoparticles modified with alkylthiol-capped oligonucleotide strands are used as probes to monitor the presence of the specific target DNA. The , which is the dissolving product of the gold nanoparticles anchored on the DNA hybrids, serves as an analyte in the H2O2–luminol– CL reaction for the indirect measurement of the target DNA. The combination of the remarkable sensitivity of the CL analysis with the large number of released from each DNA hybrid allows a detection limit at levels as low as 0.1 pM of the target DNA. Moreover, with a further silver amplification step, the detection limit will be pushed down to the femtomolar domain.   相似文献   

14.
采用电化学石英晶体微天平, 现场监测不同界面电场下完全匹配的靶标DNA和不完全匹配的靶标DNA分别与寡聚核苷酸探针分子杂交的过程. 结果表明, 电极表面荷正电时DNA表观杂交效率比电极表面荷负电时高, 但假阳性比较显著; 而电极表面荷负电时能有效地抑制错配杂交. 探讨了引入界面电场后探针分子取向和微观作用力对DNA杂交的影响.  相似文献   

15.
A label-free electrochemical detection protocol for DNA hybridization is reported for the first time by using a gold electrode (AuE). The oxidation signal of guanine was monitored at +0.73 V by using square wave voltammetry (SWV) on self-assembled l-cysteine monolayer (SAM) modified AuE. The electrochemical determination of hybridization between an inosine substituted capture probe and native target DNA was also accomplished. 6-mer adenine probe was covalently attached to SAM via its amino link at 5 end. Then, 6-mer thymine-tag of the capture probe was hybridized with the adenine probe, thus left the rest of the oligonucleotide available for hybridization with the target. The dependence of the guanine signal upon the concentration of the target was observed. Probe modified AuE was also challenged with non-complementary and mismatch containing oligonucletides. Label-free detection of hybridization on AuE is greatly advantageous over the existing carbon and mercury electrode materials, because of its potential applicability to microfabrication techniques. Performance characteristics of the genosensor are described, along with future prospects.  相似文献   

16.
A new strategy for homogeneous detection of DNA hybridization in single-step format was developed based on fluorescence quenching by gold nanoparticles. The gold nanoparticle is functionalized with 5’-thiolated 48-base oligonucleotide (probe sequence), whose 3’-terminus is labeled with fluorescein (FAM), a negatively charged fluorescence dye. The oligonucleotide adopts an extended configuration due to the electrostatic repulsion between negatively charged gold nanoparticle and the FAM-attached probe sequence. After addition of the complementary target sequence, specific DNA hybridization induces a conformation change of the probe from an extended structure to an arch-like configuration, which brings the fluorophore and the gold nanoparticle in close proximity. The fluorescence is efficiently quenched by gold nanoparticles. The fluorescence quenching efficiency is related to the target concentration, which allows the quantitative detection for target sequence in a sample. A linear detection range from 1.6 to 209.4 nmol/L was obtained under the optimized experimental conditions with a detection limit of 0.1 nmol/L. In the assay system, the gold nanoparticles act as both nanoscaffolds and nanoquenchers. Furthermore, the proposed strategy, in which only two DNA sequences are involved, is not only different from the traditional molecular beacons or reverse molecular beacons but also different from the commonly used sandwich hybridization methods. In addition, the DNA hybridization detection was achieved in homogenous solution in a single-step format, which allows real-time detection and quantification with other advantages such as easy operation and elimination of washing steps.  相似文献   

17.
Yang M  Liu C  Qian K  He P  Fang Y 《The Analyst》2002,127(9):1267-1271
The electrogenerated chemiluminescence (ECL) behavior of N-(4-aminobutyl)-N-ethylisoluminol (ABEI) was studied and it was found that ABEI could produce emission light when oxidized at a +1.0 V (vs. Ag/AgCl) potential in alkaline solution. The addition of H2O2 markedly improved the ECL sensitivity. The pH value of the solution as well as the H2O2 concentration and working potential all have influences on the ECL response. Under optimal conditions, ABEI can be detected in the range 1.3 x 10(-6)-6.5 x 10(-12) mol L(-1). A detection limit of 2.2 x 10(-12) mol L(-1) for ABEI was obtained at a signal-to-noise ratio of 3. ABEI was then used as a marker to label a known sequence oligonucleotide, which was used as a DNA probe for identifying a target ssDNA immobilized on a PPy modified electrode based on a specific hybridization reaction. The hybridization events were evaluated by the ECL measurements. The results showed that only a complementary sequence could form a double-stranded DNA with the DNA probe and give a strong ECL response. A three-base mismatch sequence and non-complementary sequence have no response. The intensity of the ECL was linearly related to the concentration of the complementary sequence in the range 9.6 x 10(-11)-9.6 x 10(-8) mol L(-1), the detection limit was 3.0 x 10(-11) mol L(-1).  相似文献   

18.
Zou B  Ma Y  Wu H  Zhou G 《The Analyst》2012,137(3):729-734
Detection of nucleic acids with signal amplification is preferable in clinical diagnosis. A novel approach was developed for signal amplification by coupling invasive reaction with hyperbranched rolling circle amplification (HRCA). Invasive reaction, which does not rely on specific recognition sequences in a target but a specific structure formed by the specific binding of an upstream probe and a downstream probe to a target DNA, can generate thousands of flaps from one target DNA; then the flaps are ligated with padlock probes to form circles, which are the templates of HRCA. As HRCA amplicon sequence is free of target DNA sequence, signal amplification is achieved. Because flap sequence is the same to any target of interest, HRCA is universal; the detection cost is hence greatly reduced. The sensitivity of the proposed method is less than 1 fM artificial DNA targets; and the specificity of the method is high enough to discriminate one base difference in the target sequence. The feasibility was verified by detecting real biological samples from HBV carriers, indicating that the method is highly sensitive, cost-effective, and has a low risk of cross-contamination from amplicons. These properties should give great potential in clinical diagnosis.  相似文献   

19.
A miniaturized multiplex biosensor exploiting a microfluidic oligonucleotide array and chemiluminescence (CL) lensless imaging detection has been developed for parvovirus B19 genotyping. The portable device consists of a reaction chip, comprising a glass slide arrayed with three B19 genotype-specific probes and coupled with a polydimethylsiloxane microfluidic layer, and a charge-coupled device camera modified for lensless CL imaging. Immobilized probes were used in DNA hybridization reactions with biotin-labeled targets, and then hybrids were measured by means of an avidin-horseradish peroxidase (HRP) conjugate and CL detection. All hybridization assay procedures have been optimized to be performed at room temperature through the microfluidic elements of the reaction chip, with sample and reagents delivery via capillary force exploiting adsorbent pads to drive fluids along the microchannels. The biosensor enabled multiplex detection of all B19 genotypes, with detectability down to 80 pmol?L?1 for all B19 genotype oligonucleotides and 650 pmol?L?1 for the amplified product of B19 genotype 1, which is comparable with that obtained in traditional PCR-ELISA formats and with notably shorter assay time (30 min vs. 2 h). The specificity of the assay has been evaluated by performing DNA–DNA hybridization reactions among sequences with different degrees of homology, and no cross hybridizations among B19 genotypes have been observed. The clinical applicability has been demonstrated by assaying amplified products obtained from B19 reference serum samples, with results completely consistent with the reference PCR-ELISA method. The next crucial step will be integration in the biosensor of a miniaturized PCR system for DNA amplification and for heat treatment of amplified products.
Figure
A portable multiplex biosensor was developed for detection and genotyping of parvovirus B19 DNA, exploiting lensless CL imaging. The reaction chip is composed of a polydimethylsiloxane microfluidic layer coupled with a glass slide on which oligonucleotide probes specific for three different B19 genotypes are covalently immobilized in a 3?×?3 array. The reaction chip was used in hybridization reactions with biotin-labeled targets and then hybrids were then detected by means of an avidin-HRP conjugate, upon addition of a CL substrate for HRP  相似文献   

20.
Guven B  Boyacı İH  Tamer U  Çalık P 《The Analyst》2012,137(1):202-208
In this study, a new method combining magnetic separation (MS) and surface-enhanced Raman scattering (SERS) was developed to detect genetically modified organisms (GMOs). An oligonucleotide probe which is specific for 35 S DNA target was immobilized onto gold coated magnetic nanospheres to form oligonucleotide-coated nanoparticles. A self assembled monolayer was formed on gold nanorods using 5,5'-dithiobis (2-nitrobenzoic acid) (DTNB) and the second probe of the 35 S DNA target was immobilized on the activated nanorod surfaces. Probes on the nanoparticles were hybridized with the target oligonucleotide. Optimization parameters for hybridization were investigated by high performance liquid chromatography. Optimum hybridization parameters were determined as: 4 μM probe concentration, 20 min immobilization time, 30 min hybridization time, 55 °C hybridization temperature, 750 mM buffer salt concentration and pH: 7.4. Quantification of the target concentration was performed via SERS spectra of DTNB on the nanorods. The correlation between the target concentration and the SERS signal was found to be linear within the range of 25-100 nM. The analyses were performed with only one hybridization step in 40 min. Real sample analysis was conducted using Bt-176 maize sample. The results showed that the developed MS-SERS assay is capable of detecting GMOs in a rapid and selective manner.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏