首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Methacrylate-ester-based monoliths containing quaternary ammonium groups were prepared in situ in capillary columns and in simultaneous experiments in vials, employing thermal initiation. The chromatographic properties of the monoliths were determined with capillary electrochromatography (CEC), and their morphology was studied with mercury-intrusion porosimetry on the bulk materials. Materials with different, well repeatable pore-size distributions could be prepared. A satisfactory column-to-column and run-to-run repeatability was obtained for the electro-osmotic mobility, the retention characteristics (k-values) and the efficiency on the columns prepared and tested in the CEC mode. A relatively high electro-osmotic flow was observed in the direction of the positive electrode. The electro-osmotic mobility was found to be influenced only marginally by mobile-phase parameters such as the pH, ionic strength, and acetonitrile content. The retention behavior of the monolithic columns was similar to that of columns packed with C18-modified silica particles. Columns could be prepared with optimum plate heights ranging from 6 microm for unretained compounds to 20 microm for well retained (k=2.5) polyaromatic hydrocarbons. However, for specific analytes a - still unexplained - lower chromatographic column efficiency was observed.  相似文献   

2.
Allen D  El Rassi Z 《The Analyst》2003,128(10):1249-1256
Three different synthetic routes have been introduced and evaluated for the preparation of amphiphilic silica-based monoliths possessing surface-bound octadecyl ligands and positively charged groups. The amphiphilic silica monoliths (designated as cationic C18-monoliths) have been designed for use in reversed-phase capillary electrochromatography (RP-CEC) with hydro-organic mobile phases. These amphiphilic stationary phases yielded anodic electroosmotic flow (EOF) over a wide range of mobile phase pH. The magnitude of EOF remained constant up to pH 4.0 and then decreased at pH > 4.0 due to the ionization of silanol groups and the subsequent decrease in the net positive surface charge density of the amphiphilic monoliths. The cationic C18-monoliths exhibited reversed-phase chromatography (RPC) behavior toward non-polar solutes (e.g., alkyl benzenes), which parallels that observed with octadecyl-silica (ODS) monoliths. On the other hand, the amphiphilic stationary phases exhibited both non-polar and polar interactions toward slightly polar solutes such as anilines and PTH-amino acids. CEC retention factor k* and velocity factor k*e, which reflects the contribution of the electrophoretic mobility, were evaluated for charged solutes such as anilines and proteins.  相似文献   

3.
A neutral octadecyl monolithic (ODM) column for RP capillary electrochromatography (RP-CEC) has been developed. The ODM column was prepared by the in situ polymerization of octadecyl acrylate (ODA) as the monomer and trimethylolpropanetrimethacrylate (TRIM) as the crosslinker, in a ternary porogenic solvent containing cyclohexanol, ethylene glycol, and water. The ODM column exhibited cathodal EOF over a wide range of pH and ACN concentration in the mobile phase despite the fact that it was devoid of any fixed charges. It is believed that the EOF is due to the adsorption of ions from the mobile phase onto the surface of the monolith thus imparting to the neutral ODM column the zeta potential necessary to support the EOF required for mass transport across the monolithic column. Furthermore, the adsorption of mobile phase ions to the neutral monolith modulated solute retention and affected the separation selectivity. The wide applications of the neutral ODM column were demonstrated by its ability to separate a wide range of small and large solutes, both neutral and charged. While the separation of the neutral solutes was based on RP retention mechanism, the charged solutes were separated on the basis of their electrophoretic mobility and hydrophobic interaction with the C18 ligands of the stationary phase. As a typical result, the neutral monolithic column was able to separate peptides quite rapidly with a separation efficiency of nearly 200,000 plates/m, and this efficiency was exploited in tryptic peptide mapping of standard proteins, e. g., lysozyme and cytochrome C, by isocratic elution.  相似文献   

4.
In the last decade, silica monolithic capillaries have focused more and more attention on miniaturized separation techniques like capillary electrochromatography (CEC), nano-liquid chromatography (nano-LC) and chip electrochromatography owing to their unique chromatographic properties and their simplified preparation compared with packed columns. They are synthesized according to a sol-gel multi-step process that includes, after a gelation step at 40 degrees C leading to the formation of the macropores network and the silica skeleton, a post-gelation step (hydrothermal treatment at 120 degrees C in basic medium) that allows to tailor the mesopores and finally a calcination or a washing step to remove remaining polymers. In order to reduce the synthesis time, the number of synthesis steps and above all the temperature synthesis, to adapt the synthesis of such silica monoliths in polymeric microsystem devices, we extensively studied the influence of the hydrothermal treatment and its duration on textural (pore size distribution) and chromatographic properties (retention, efficiency) of in situ-synthesized capillary monoliths in nano-LC and CEC. This study was performed on pure silica and octyl chains grafted silica monoliths. Untreated monoliths show small pores (<6 nm), whereas hydrothermally treated monoliths exhibit medium and large mesopores (8-17 nm). It was demonstrated that the hydrothermal treatment at 120 degrees C was not necessary for pure silica monolithic capillaries dedicated to normal phase liquid chromatography or hydrophilic interaction liquid chromatography (HILIC) and electrochromatography: the suppression of the hydrothermal treatment did not impair efficiencies in CEC and in nano-LC but contributed to increase in retention factors. Minimal plate heights of ca. 5 microm in CEC and 6 microm in nano-LC were obtained with or without hydrothermal treatment with bare silica. In the same way, the hydrothermal treatment was not necessary for grafted silica monoliths only dedicated to CEC. However, the results clearly indicate that the hydrothermal treatment becomes essential before grafting in order to preserve the efficiency of the monolithic silica capillaries dedicated to nano-LC: in this particular case, the suppression of the hydrothermal treatment leads approximately to a loss of a factor two in efficiency.  相似文献   

5.
Bedair M  El Rassi Z 《Electrophoresis》2002,23(17):2938-2948
A novel monolithic stationary phase having long alkyl chain ligands (C17) was introduced and evaluated in capillary electrochromatography (CEC) of small neutral and charged species. The monolithic stationary phase was prepared by the in situ copolymerization of pentaerythritol diacrylate monostearate (PEDAS) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent consisting of cyclohexanol/ethylene-glycol/water. While AMPS was meant to support the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary, the PEDAS was introduced to provide the nonpolar sites for chromatographic retention. Monolithic columns at various EOF velocities were readily prepared by conveniently adjusting the amount of AMPS in the polymerization solution as well as the composition of the porogenic solvent. The monolithic stationary phases thus obtained exhibited reversed-phase chromatography behavior toward neutral solutes and yielded a relatively strong EOF. For charged solutes (e.g., dansyl amino acids), nonpolar as well as electrostatic interaction/repulsion with the monoliths were observed in addition to electrophoretic migration. Therefore, for charged solutes, selectivity and migration can be readily manipulated by changing various parameters including the nature of the monolith and the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). Ultrafast separation on the time scale of seconds of 17 different charged and neutral pesticides and metabolites were performed using short capillary columns of 8.5 cm x 100 microm ID.  相似文献   

6.
During the last decade, silica monolithic capillaries have focused more and more attention on miniaturized separation techniques like CEC, nano-LC, and chip electrochromatography owing to their unique chromatographic properties and to their possible in situ synthesis. Nevertheless, the preparation of conventional silica-based individual monolithic columns is time consuming, owing to the individual steps involved, including the synthesis of the silica matrix and its subsequent on-column chemical grafting. The hybrid organic-inorganic monoliths, whose synthesis is based on the polycondensation of siloxane with organosiloxane precursors, seems to be an attractive alternative since their direct synthesis leads to silica monoliths with organic moieties covalently linked to the inorganic silica matrix through hydrolytically stable Si-C bonds. This study describes the synthesis of hybrid monoliths using propyltrimethoxysilane (C3-TriMOS) as a new kind of silica coprecursor to subsequently increase the hydrophobicity of the stationary phase. The influence of several experimental parameters (pH, gelation temperature, relative proportion of the precursors) on the textural (skeleton and macropore size) and chromatographic properties (efficiency, retention, and electroosmotic mobility) of the obtained monoliths are discussed. The results show that the optimal coprecursor incorporation is obtained after a postgelation step during which the condensation of the C3-TriMOS coprecursor is favored by an increase in the pH medium. Thermal hydrolysis of urea previously added to the polymerization mixture allows this in situ pH increase. These hybrid monoliths present hydrophobic properties and allow the separation of test mixtures in the RP mode without any further modification. Moreover, they present excellent efficiencies since reduced plate height as low as 5 and 15 microm are obtained in the electrodriven mode (CEC) and in the hydrodynamic one (nano-LC), respectively.  相似文献   

7.
A comparison is made between the efficiency of microparticulate capillary columns and silica and polymer-based monolithic capillary columns in the pressure-driven (high-performance liquid chromatography) and electro-driven (capillary electrochromatography) modes. With packed capillary columns similar plate heights are possible as with conventional packed columns. However, a large variation is observed in the plate heights for individual columns. This can only be explained by differences in the quality of the packed bed. The minimum plate height obtained with silica monolithic capillary columns in the HPLC mode is approximately 10 microm, which is comparable to that of columns packed with 5-microm particles. The permeability of wide-pore silica monoliths was found to be much higher than that of comparable microparticulate columns, which leads to much lower pressure drops for the same eluent at the same linear mobile phase velocity. For polymer-based monolithic columns (acrylamide, styrene/divinyl benzene, methacrylate, acrylate) high efficiencies have been found in the CEC mode with minimum plate heights between 2 and 10 microm. However, in the HPLC mode minimum plate heights in the range of 10 to 25 microm have been reported.  相似文献   

8.
Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.  相似文献   

9.
A hydride-based octadecyl stationary phase on both 4.0 and 1.8 microm silica particles is tested in both the capillary LC and the pressurized capillary electrochromatography (pCEC) modes. These two materials are compared to standard C18 stationary phase made by organosilanization and to the hydride material packed into a convention 4.6mm I.D. column. The performance of the capillary columns is evaluated in terms of analysis times for various mixtures as well as efficiency. Of particular interest are the differences between the LC mode where only laminar flow is present and pCEC operation where a flat electrodriven flow profile is superimposed on the parabolic pressurized flow. Differences in performance between columns packed with 4.0 and 1.8 microm particle silica are also evaluated.  相似文献   

10.
A method is described for the synthesis of rigid, macroporous polymers (monoliths) to be used as stationary phases in capillary electrochromatography (CEC). The procedure reproducibly results in columns with good mechanical and chemical stability. Once the procedure was optimized, it yielded the desired CEC columns in nearly 100% of the cases. The batch-to-batch standard deviation of the migration of the electroosmotic flow (EOF) marker for nine randomly chosen columns was 5%. The polymerization is carried out inside the capillary, an aqueous phase is used as solvent. Monomers based on acrylamides with varying hydrophilicity were used to introduce the interactive moieties together with piperazine diacrylamide as cross-linker and vinylsulfonic acid as provider of the charged, EOF-producing moieties. The pore size of the monoliths was adjusted by adding varying amounts of ammonium sulfate to the reaction mixture. In this manner, the average pore size of a given monolith could be reproducibly adjusted to values ranging from 50 nm to 1.3 microm. The procedure was optimized for four particular types of monoliths, which differed in hydrophobicity. The latter was adjusted by introducing suitable co-monomers, such as alkyl chain-bearing molecules, into the monolithic structure. Attempts to systematically investigate the chromatographic behavior of the monolithic stationary phases were made, using a model mixture of aromatic compounds as sample. The standard deviations for the run-to-run reproducibility of the retention times for unretained and retained analytes were <1.5%. Flat Van Deemter curves were measured even at elevated flow-rates (2 mm/s). Plate heights between 10 and 15 microm were measured in this range. The retention order was taken as the principal indication for the chromatographic mode. The separation was found to be governed neither by pure reversed-phase nor by pure normal-phase chromatography, even on monoliths, where large amounts of C6 ligands had been introduced.  相似文献   

11.
Continuous-bed columns containing sol-gel bonded 3 microm silica particles with mixed-mode octadecyl and propylsulfonic acid functional groups (ODS/SCX) were prepared by first packing the ODS/SCX particles into a fused-silica capillary, then filling the packed capillary with a siliceous sol-gel, curing the sol-gel, and finally drying the column with supercritical carbon dioxide. The performance of the sol-gel bonded ODS/SCX columns was evaluated for capillary electrochromatography using acetonitrile aqueous mobile phase containing phosphate buffer. The columns were mechanically strong and permeable. Both EOF velocity and current increased linearly with elevation of the applied electric field strength. The EOF velocity was high at low pH and nearly constant over a range of pH 2-9. Higher buffer concentration resulted in higher current and lower EOF velocity. The acetonitrile content had no significant effect on the EOF. Without thermosetting the column, no bubble formation was noticed with currents up to 2.5 microA. The minimum plate height of a 25/34 cm x 75 microm I.D. sol-gel bonded 3 microm ODS/SCX column was 5.7 microm (1.75 x 10(5) plates per meter) at an optimum EOF velocity of 0.92 mm s(-1). Mixtures of test aromatic compounds and aromatic hydrocarbon homologues gave symmetrical peaks when using a low pH mobile phase. The retention and elution order of aromatic compounds represented a typical reversed-phase separation mechanism similar to conventional ODS columns. The run-to-run and column-to-column retention factor reproducibility was better than 2.5% and 8.0% RSD, respectively.  相似文献   

12.
High efficiency and highly retentive monolithic silica capillary columns were obtained by polymerization of octadecyl methacrylate using alpha,alpha'-azobis-isobutyronitrile (AIBN) as a free radical initiator. Hybrid type monolithic silica columns (25 cm total length x 200 microm I.D.) prepared from a mixture of tetramethoxysilane and methyltrimethoxysilane were used as a support. The effects of the monomer and the radical initiator concentrations in the reaction mixture were examined. The performance of the columns was tested in terms of column efficiency and retention behavior by using alkylbenzenes and a few other compounds as solutes and compared with that of hybrid monolithic silica columns modified with octadecylsilyl-(N,N-diethylamino)silane (ODS-DEA). Highly retentive monolithic silica columns were obtained by polymerization at high monomer concentrations. Although a decrease in column efficiency was observed with the increase in the monomer concentration in a feed mixture, an improvement in efficiency was achieved (a plate height value lower than 10 microm) by increasing an initiator concentration without significant variations in column retention properties. Results obtained by polymerization using other monomers are also presented to demonstrate the applicability of the preparation method.  相似文献   

13.
Stationary phase selectivities for halogenated compounds in reversed-phase HPLC were compared using C18 monolithic silica capillary columns modified with poly(octadecyl methacrylate) (ODM) and octadecyl moieties (ODS). The preferential retention of halogenated benzenes on ODM was observed in methanol/water and acetonitrile/water mobile phases. In selectivity comparison of selected analytes on ODM and ODS, greater selectivities for halogenated compounds were obtained with respect to alkylbenzenes on an ODM column, while similar selectivities were observed with a homologous series of alkylbenzenes on ODM and ODS columns. These data can be explained by greater dispersive interactions by more densely packed octadecyl groups on the ODM polymer coated column together with the contribution of carbonyl groups in ODM side chains. For the positional isomeric separation of dihalogenated benzenes (ortho-, meta-, para-), the ODM column also provided better separation of these isomers for the adjacently eluted isomers that cannot be completely separated on an ODS column in the same mobile phase. These results imply that the ODM column can be used as a better alternative to the ODS column for the separation of other halogenated compounds.  相似文献   

14.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

15.
Monolithic columns have been prepared with a novel bonded silica stationary phase, tetradecylamine bonded silica (TDAS), and used in pressurized capillary electrochromatography (pCEC). The monolithic silica column matrix was prepared by a sol-gel process and then chemically modified with the spacer (3-glycidoxypropyl)trimethoxysilane and tetradecylamine. The introduced embedded polar amine groups dominated the charge on the surface of the monolithic stationary phase and generated an EOF from cathode to anode under acidic conditions. The tetradecyl hydrophobic chains in TDAS provide chromatographic interactions. The chromatographic characteristics of the prepared monolithic column were studied. Some aromatic compounds including alkylbenzenes, aromatic hydrocarbons, phenols, and anilines were successfully separated on the TDAS monolithic column in pCEC mode. As expected, the TDAS monolithic stationary phases exhibit typical reversed-phase electrochromatographic behavior toward neutral solutes due to the introduced tetradecyl groups. Hydrophobic as well as electrophoretic migration processes within the monoliths were observed in the separation of basic anilines. Symmetrical peaks can be obtained for anilines because the embedded polar amine groups on the surface can effectively shield the adsorption of positively charged analytes onto the stationary phase.  相似文献   

16.
This review summarizes the contributions to the rapidly growing area of monolithic columns based on both silica and synthetic polymers for capillary electrochromatography and chip electrochromatography, with a focus on those published during the year 2004. A wide variety of both modified approaches to the "old" monoliths and new monoliths have been reported despite the very short period of time covered. This demonstrates that monolithic stationary phases have become a well-established format in the field of electrochromatography. The simplicity of their preparation as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials.  相似文献   

17.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

18.
This paper describes the fabrication of RP/ion-exchange mixed-mode monolithic materials for capillary LC. Following deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (gamma-MAPS), monoliths were formed by copolymerisation of pentaerythritol diacrylate monostearate (PEDAS), 2-sulphoethyl methacrylate (SEMA) with/without ethylene glycol dimethacrylate (EDMA) within 100 microm id capillaries. In order to investigate the porous properties of the monoliths prepared in our laboratory, mercury intrusion porosimetry, SEM and micro-HPLC were used to measure the monolithic structures. The monolithic columns prepared without EDMA showed bad mechanical stability at high pressure, which is undesirable for micro-HPLC applications. However, it was observed that the small amount (5% w/w) of EDMA clearly improved the mechanical stability of the monoliths. In order to evaluate their application for micro-HPLC, a range of neutral, acidic and basic compounds was separated with these capillaries and satisfactory separations were obtained. In order to further investigate the separation mechanism of these monolithic columns, comparative studies were carried out on the poly(PEDAS-co-SEMA) monolithic column and two other monoliths, poly(PEDAS) and poly(PEDAS-co-2-(methacryloyloxy)ethyl-trimethylammonium methylsulphate (METAM)). As expected, different selectivities were observed for the separation of basic compounds on all three monolithic columns using the same separation conditions. The mobile phase pH also showed clear influence on the retention time of basic compounds. This could be explained by ion-exchange interaction between positively charged analytes and the negatively charged sulphate group.  相似文献   

19.
20.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号