Summary A new method has been developed for the quantitative determination of gas mixture composition where air penetration during gas sample collection would lead to erroneous results. It requires the use of a stationary phase that separates gas sample components and the air and involves 4–5 analyses of samples of equal volumes containing different amounts of air. By graphical extrapolation of the air peak area (S air ) as a function of the peak areas of the individual components (S comp ) the areas for these components in the absence of air can be obtained forS air =0. Using calibration curves for the pure gas components the true quantitative composition of the gas mixture is estimated.  相似文献   

3.
Gas chromatography–combustion–isotope mass spectrometry was employed for the assessment of the Carbon isotope ratios of volatiles in Italian mandarin and lemon petitgrain oils. In addition, the composition of the whole oil and the enantiomeric distribution of selected chiral compounds were determined for all the samples by using gas chromatography and by multidimensional and conventional enantioselective gas chromatography. The composition of the oils was compared with previous studies. The enantiomeric distribution of lemon petitgrain oils is here reported for the first time. On the composition of mandarin petitgrain oil, the information available in literature, to date, is relative only to one sample from Egypt. Carbon isotope ratio of several terpene hydrocarbons and of their oxygenated derivatives contained in petitgrains was compared with the δ 13CVPDB values of the same compounds present in the corresponding genuine Italian Citrus peel oil. The results prove that the isotopic values obtained for lemon and mandarin petitgrain oils are very close to those relative to the corresponding peel oils determined in previous studies.  相似文献   

4.
For two-dimensional reversed-phase liquid chromatography–gas chromatography (2D RPLC–GC), a specially-designed needle packed with a polymer-coated fibrous stationary phase was introduced as a novel interface. The bundle of synthetic fibers coated with polydimethylsiloxane (PDMS) was packed into the head section of the needle, and served as the extraction medium. Using the post-column dilution of the LC eluent by water and subsequent extraction with the needle interface, the analyte was successfully concentrated to the PDMS phase on the fibrous support in the needle. The concentrated analytes were directly injected to GC system by inserting the needle to a heated GC injector. 2D separations of aliphatic and aromatic hydrocarbons, and also kerosene-extract were performed with the off-line RPLC–GC system interfaced by the needle extractor. The results suggested that the fiber-packed needle interface could be one of the simple and effective approaches to develop an on-line coupled LC–GC system.  相似文献   

5.
Monoacylglycerols (MAGs) are lipids found in trace amounts in plants and animal tissues. While they are widely used in various industrial applications, accurate determination of the regio-specific distribution is hindered by the lack of stable, commercially available standards. Indeed, unsaturated β-MAG (or Sn-2 MAG) readily undergoes isomerization into α-MAG (acyl chain is attached to the Sn-1 or the Sn-3 position). In the present study, we describe structural elucidation of α- and β-regio-isomers of monopalmitoyl-glycerol (MAG C16:0) as model compounds in their silylated forms using gas chromatography–mass spectrometry (GC–MS) with electronic impact (EI) ionization. MS fragmentation of α-MAG C16:0 is characterized by the loss of methylene(trimethylsilyl)oxonium (103 amu) and the consecutive loss of acyl chain yielding a fragment ion at m/z 205. The fragmentation pattern of β-MAG C16:0 shows a series of diagnostic fragments at m/z 218, 203, 191 and 103 that are not formed from the α-isomer and hereby enable reliable distinction of these regio-isomers. Possible fragmentation scenarios are postulated to explain the formation of these marker ions, which were also applied to characterize the regio-isomer composition of a complex mixture of MAG sample containing n-3 long-chain polyunsaturated fatty acids.  相似文献   

6.
Although comprehensive 2-D GC is an established and often applied analytical method, the field is still highly dynamic thanks to a remarkable number of innovations. In this review, we discuss a number of recent developments in comprehensive 2-D GC technology. A variety of modulation methods are still being actively investigated and many exciting improvements are discussed in this review. We also review interesting developments in detection methods, retention modeling, and data analysis.  相似文献   

7.
n-Butyl benzyl phthalate (BBP) is an endocrine-disrupting chemical. A bacterium species capable of using BBP as the sole source of carbon and energy was isolated from mangrove sediment. Effects of BBP concentration, pH, temperature, and salinity on BBP biodegradation were studied. The optimum pH, temperature, and salinity for the BBP biodegradation were 7.0, 37°C, and 15 g L−1, respectively. BBP was completely degraded within 6 days under optimum conditions, and the biodegradation of BBP could be fitted to a first-order kinetic model. The major metabolites of BBP biodegradation were identified as mono-butyl phthalate, mono-benzyl phthalate, phthalic acid, and benzoic acid by using high-performance liquid chromatography and gas chromatography–mass spectrometry. A preliminary metabolic pathway was proposed for the biodegradation of BBP.   相似文献   

8.
Pyrolysis gas chromatography–mass spectrometry (PyGC-MS) was used as a rapid method for the characterization of permanent marker ink. Twenty-four samples of various colours purchased from different manufacturers were characterised. Four main typologies of polymer-binding medium could be distinguished on the basis of the pyrolysis products, and differentiation between permanent markers of different manufacturers could be accomplished. For some permanent marker samples, PyGC-MS analysis allowed pigment identification as well.  相似文献   

9.
The performance of Fourier transform infrared spectroscopy (FT-IR) detection coupled to high-performance liquid chromatography for the analysis of C60 and C70 fullerenes was investigated. The isocratic separation method involved an octadecylsilane (ODS) column and an acetonitrile–toluene (1:1) mobile phase. The hyphenated system was designed with a split valve to control eluent volume leading to the FT-IR detector; this allowed for additional coupling of the liquid chromatograph to ultraviolet–visible detection. On-line FT-IR spectra of C60 and C70 were matched with standard off-line FT-IR spectra from the literature. In addition, with band chromatograms individual fullerenes can be identified using FT-IR active modes known specifically for each fullerene. Few changes to a pre-existing HPLC–UV method were necessary for the HPLC–FT-IR method, and there was no need for fraction collection to identify the fullerenes C60 and C70.  相似文献   

10.
11.
The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have been evaluated using pyrolysis–gas chromatography–mass spectrometry (Py–GC–MS) and gas chromatography–mass spectrometry (GC–MS). The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC–MS. Two types of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally, the studied biocides—Biotin, New-Des and Nipagine—generally exhibited good inhibiting effects on the microorganisms studied, although some interesting differences were found between them regarding the application method and type of biocide.  相似文献   

12.
Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis–gas chromatography–mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL?1 is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time.
Figure
SEC/-/Py-GC-MS (reconstructed, chromatograms) of dissolved polymer in ACN/THF%.  相似文献   

13.
A method for the determination of S0 in coal based on the extraction with cyclohexane with subsequent quantitative analysis of elemental sulfur in the extract by GC/MS is described. The quantity of elemental sulfur was determined in four coal samples with different distribution of sulfur forms. The effect of solvent and extraction time on the efficiency of sulfur removal was studied. The elemental sulfur extracted from coal occurred in the form of S6, S7 and S8. Calibration solutions were prepared from freshly recrystalized elemental sulfur. It was found that the injection temperature has a crucial influence on the m/z 64 ion chromatogram.  相似文献   

14.
A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor ( stationary phase loading, carrier gas flow rate and column temperature ) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted.  相似文献   

15.
A computer-assisted method is presented for simultaneous optimization of three-factor of temperature programming (initial temperature, temperature rising rate and carrier gas flow rate) for the separation of eleven compounds in capillary gas chromatography. The optimization of the separation over the experimental region is based on a special polynomial from fifteen preliminary experiments using the resolution as the selection criterion. Computer scanning technique was used for optimum selection on three dimensions. Excellent agreement was found between the predicted data and the experimental results.  相似文献   

16.
The application of ionic liquids (ILs) as nonderivatizing solvents for the pretreatment and regeneration of cellulose is a growing area of research. Here we report the development of a rapid and simple method for the determination of residual ethanol content in two hydrophilic ILs, 1-butyl-3-methylimidazolium chloride and 1-ethyl-3-methylimidazolium acetate. The method utilizes headspace solid-phase microextraction coupled with gas chromatography at elevated extraction temperatures, resulting in rapid equilibration times. The effect of IL water content on the ethanol extraction efficiency is presented. Recovery experiments carried out in real samples gave recoveries ranging from 96.8 to 98.2%.  相似文献   

17.
Cacha?a samples were studied by means of comprehensive two-dimensional gas chromatography and time-of-flight mass spectrometry (GCxGC/TOFMS) during the fermentation process and after ageing in different wood materials. The analyses of the aroma compounds were performed after headspace-solid phase microextraction method (HS-SPME) using an 85microm polyacrylate (PA) fibre. Fingerprint monitoring of the distillation process allowed the easy determination of the turning points of the process and high-resolution comparison of cabe?a (head), cora??o (core) and cauda (tail) fractions. The ageing process in different wood materials was well characterised through fingerprint similarity observations; in the absence of a suitable metric for expressing the overall similarity, here we use a visual and retention time comparison to identify co-incident peaks and those that differ between samples. For quality control purposes, a simple observation of the contour plots obtained can thus allow the identification of the type of wood used in the ageing process, and the process of ageing, without further statistical treatment or peak identifications. In this manner, peaks, which discriminated most between the different mixtures studied were readily found, i.e. unique compounds were identified in each stage of the distillation process. Approximate first dimension linear retention indices (LRI) for these identified compounds were calculated in a bi-dimensional polar/non-polar column set in the GCxGC experiment and were used in conjunction with mass spectral library searching for tentative identification. Along the progression of the distillation process, 70 compounds appear to visually discriminate between samples and their retention indices are indicated, presenting good correlation with literature data.  相似文献   

18.
Isothermal Kováts' retention indices are currently reported as whole numbers, and are frequently deduced from a linear least mean squares fitting of the logarithms of adjusted retention times of a number of n-alkanes versus carbon number, following an iterative method that minimises errors. The currently accepted accuracy is about one retention index unit for apolar stationary phases, and lower for polar stationary phases. This paper presents results that show how the accuracy of the retention index may be safely reported to one-tenth of a retention index unit by the use of a non-linear equation, with present day gas chromatographs without electronic flow controllers. Results are presented that prove the correctness of the retention indices found for several substances on one particular capillary column. Hints on the minimum retention times needed to achieve the 0.1 retention index accuracy are mentioned, for retention times recorded in minutes and in seconds. According to results of this paper, two chromatograms, run under the appropriate conditions, are sufficient to obtain the desired accuracy. The method proposed in this paper does not require knowledge of the hold-up time of the chromatogram.  相似文献   

19.
There is a growing demand for the rapid screening of multiple β-blockers and β-agonists in a single analytical run in clinical toxicology, antidoping control, forensic and environmental science. Although GC-MS is very often used to determine pharmaceuticals from these groups of drugs, the literature data on the derivatization and MS analysis of mixtures of these compounds is limited. This paper compares and evaluates derivatization procedures for the determination of six β-blockers (acebutolol, atenolol, metoprolol, nadolol, propranolol, pindolol) and two β-agonists (salbutamol, terbutaline) using GC techniques. Nineteen different derivatizing reagents (nine of them used for the first time with almost all the drugs) were employed in order to obtain a single derivative for each target compound with the greatest effectiveness of this reaction. Trimethylsilylation, tert-butyldimethylsilylation, acylation (e.g. trifluoroacetylation), combined trimethylsilylation and acylation, and the formation of cyclized silyl derivatives were carried out and the mass spectra (EI, 70 eV) recorded. The influence of the reaction time and temperature on these procedures was investigated. Additionally, the effects of the type of solvent and the amount of added trimethylchlorosilane (TMCS) on the silylation of the target compounds using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) were tested. Among of the five mentioned above derivatization procedures applied - trimethylsilylation was found to be the most effective for derivatizing the analytes. The best results were obtained with a 1:1 (v/v) mixture of 99% BSTFA+1% TMCS and ethyl acetate at 60 °C for 30 min. The MS data for different types of β-blocker and β-agonist derivatives is presented. The information in this paper is valuable for scientists working on the determination of β-blockers and β-agonists in biological and environmental matrices.  相似文献   

20.
A preliminary investigation using gas chromatography–mass spectrometry (GC–MS) to analyze the nicotine contained in tobacco leaves was carried out. Nicotine is an alkaloid and tobacco leaves was extracted with methanol and determined by GC–MS. The detection limit for nicotine was at the ppm level for non selective monitoring and the nanogram level for selective detection. This is a simple chromatography–mass spectrometry method for the analysis of nicotine in tobacco leave. Compared to other currently utilized methods for the detection of nicotine in tobacco leaves, the GC–MS provided advantages of high sensitivity, nicotine specific detection and lower instrumentation cost.  相似文献   