首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns.The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS.The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers.  相似文献   

2.
Haloperidol, paracetamol, metronidazole and metamizole have been tested as tune compounds for electrospray ionisation in-source collision-induced dissociation MS (ESI-CID-MS) with two different mass spectrometers (Sciex API 365 and Agilent 1100 MSD SL). The different electrospray sources of API 365 and MSD 1100 SL consist of an orifice with nitrogen curtain gas and a capillary interface, respectively. In-source CID occurs in both interfaces in front of the skimmers, which separate a region with a vacuum of approximately 300 Pa and the high vacuum (<10(-3) Pa). Comparison of the breakdown curves of selected tune compounds, depending on collision energy (orifice or fragmentor voltage), showed, that very similar fragmentation can be obtained with both instruments, when adjusting the fragmentor voltage of the MSD 1100 SL to higher values than the orifice voltage of the API 365. For three energy levels--low, medium and high--the corresponding voltages were 20, 50 and 80 V for the API 365 and 110, 190, 230 V for the MSD 1100 SL. These voltages resulted in the most similar spectra for haloperidol and paracetamol with both instruments. The comparison of ESI-CID-MS of all tune compounds at three energy levels showed, that - despite variations in relative ion abundances - all significant ions were present in one of the three CID spectra. Therefore, mass spectral library searching of an ESI-CID-MS library set-up with one of the two instruments should be possible with the other instrument after adjusting the CID energies by means of at least two tune compounds such as haloperidol and paracetamol, metronidazole or metamizole.  相似文献   

3.
Tuning compounds for positive and negative electrospray ionization (ESI) were tested for the tuning of in-source collision-induced dissociation (ESI/CID) with three types of SCIEX API instruments (API 365, 2000 and 3000) in the single-quadrupole mode. The vacuum interfaces of these instruments differ slightly in geometry, but the principles of ionization and solvent evaporation by nebulizer and curtain gases, orifice and skimmer are identical. For comparison of in-source CID, breakdown curves of haloperidol, paracetamol, metronidazole and metamizole were acquired by increasing the orifice voltages. The API 2000 and 3000 required higher orifice voltages than did the API 365 to induce a similar degree of fragmentation of the protonated or deprotonated molecules to characteristic fragment ions. This increase of orifice voltage could be demonstrated with each of the four compounds tested by a shift of the maxima of the breakdown curves to higher orifice voltages. A procedure with three collision energy (CE) levels for drug identification with a mass spectra library set up with an API 365 therefore required an adjustment of the orifice voltages to higher values when being transferred to an API 2000 or API 3000. The corresponding orifice voltages for the three instruments were 20/50/80 V (API 365), 30/90/130 V (API 2000) and 40/80/120 V (API 3000). However, a change in orifice voltage of +/-10 V (with the API 2000 and 3000) hardly influenced the fit values of a library search for each single CE level. For adjusting orifice voltages with different instruments, a tuning procedure with haloperidol and paracetamol is presented. With this tuning procedure an ESI/CID mass spectra library set up for API 365 and API 150 could also be used for drug identification with an API 2000 and an API 3000 with good library search results.  相似文献   

4.
Reproducibility of product ion spectra acquired using a liquid chromatography/triple-quadrupole mass spectrometry (LC/MS/MS) instrument over a 4-year period, and with three other LC/MS/MS instruments, one from the same manufacturer and two from a different manufacturer, was examined. The MS/MS spectra of 30 drug substances were generated in positive electrospray ionization mode at low, medium, and high collision energies (20, 35, and 50 eV). Purity and Fit score percentages against a 400-compound LC/MS/MS spectral library were calculated using an algorithm in which fragment intensity ratios and weighting factors were included. The long-term reproducibility study was conducted using a brand A instrument; after 4 years the reproducibility of the product ion spectra was still 94%, expressed as average Purity score. The inter-laboratory study involved two parts. Firstly, two LC/MS/MS spectral libraries, created independently in separate laboratories using brand A instruments, were compared with each other. The average Fit and Purity scores of spectra from one library against the other were better than 93 and 91%, respectively, when the same collision energies were used. Secondly, for the comparison of product ion spectra between brand A and brand B instruments, fragmentation conditions were first standardized for amitriptyline as the standard analyte. The average Fit scores of brand B spectra against the brand A spectral library varied between 79 and 85% at all three collision energies. These results indicate that, after standardizing the instrumental conditions, LC/MS/MS spectral libraries of drug substances are suitable for inter-laboratory use.  相似文献   

5.
Although data-dependent LC-MS-MS with database searching has become au courant for identifying proteins, the technique is constrained by duty-cycle inefficiency and the inability of most tandem mass analyzers to accurately measure peptide product ion masses. In this work, a novel approach is presented for simultaneous peptide fragmentation and accurate mass measurement using in-source collision-induced dissociation (CID) on electrospray ionization (ESI)-time-of-flight (TOF) MS. By employing internal mass reference compounds, mass measurement accuracy within +/-5 ppm for tryptic peptide precursors and +/-10 ppm for most sequence-specific product ions was consistently achieved. Analysis of a complex solution containing several digested protein standards did not adversely affect instrument performance.  相似文献   

6.
Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.  相似文献   

7.
MJ Smith  NR Cameron  JA Mosely 《The Analyst》2012,137(19):4524-4530
Atmospheric pressure Solids Analysis Probe (ASAP) mass spectrometry has facilitated the ionisation of oligomers from low molecular weight synthetic polymers, poly(ethylene glycol) (PEG: M(n) = 1430) and poly(styrene) (PS: M(n) = 1770), directly from solids, providing a fast and efficient method of identification. Ion source conditions were evaluated and it was found that the key instrument parameter was the ion source desolvation temperature which, when set to 600 °C was sufficient to vapourise the heavier oligomers for ionisation. PS, a non-polar polymer that is very challenging to analyse by MALDI or ESI without the aid of metal salts to promote cationisation, was ionised promptly by ASAP resulting in the production of radical cations. A small degree of in-source dissociation could be eliminated by control of the instrument ion source voltages. The fragmentation observed through in-source dissociation could be duplicated in a controlled manner through Collision-Induced Dissociation (CID) of the radical cations. PEG, which preferentially ionises through adduction with alkali metal cations in MALDI and ESI, was observed as a protonated molecular ion by ASAP. In-source dissociation could not be eliminated entirely and the fragmentation observed resulted from cleavage of the C-C and C-O backbone bonds, as opposed to only C-O bond cleavage observed from tandem mass spectrometry.  相似文献   

8.
Protonated molecules of 2,5-di-R1,R2-substituted-1,3,4-oxadiazoles lose isocyanic acid (loss of mass 43) via skeletal rearrangement. This was observed in low-energy CID mass spectra recorded by using electrospray ionisation (ESI). On electron ionisation induced decomposition these compounds also reveal complex skeletal rearrangement, consisting on N2 and CO elimination, leading to the formation of fluorene or indene type ions. It was found that abundances of fragment ions formed in these processes are in good agreement with their theoretically calculated stabilities. In the case of ESI use the fragment ion abundances were calculated in relation to [M+H]+ ion abundances and for EI use, where extensive fragmentations proceed, the sums of the abundances of [M-N2-CO]+. ions and abundances of fragment ions derived from them, were expressed as a percentage of total-ion current.  相似文献   

9.
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers.  相似文献   

10.
Mass spectral libraries represent versatile tools for the identification of small bioorganic molecules. Libraries based on electron impact spectra are rated robust and transferable. Tandem mass spectral libraries are often considered to work properly only on the instrument that has been used to build the library. An exception from that rule is the ‘Wiley Registry of Tandem Mass Spectral Data, MSforID’. In various studies with data sets from different kinds of tandem mass spectrometric instruments, the outstanding sensitivity and robustness of this tandem mass spectral library search approach was demonstrated. The instrumental platforms tested, however, mainly included various tandem‐in‐space instruments. Herein, the results of a multicenter study with a focus on upfront and tandem‐in‐time fragmentation are presented. Five laboratories participated and provided fragment ion mass spectra from the following types of mass spectrometers: time‐of‐flight (TOF), quadrupole–hexapole–TOF, linear ion trap (LIT), 3‐D ion trap and LIT–Orbitrap. A total number of 1231 fragment ion mass spectra were collected from 20 test compounds (amiloride, buphenin, cinchocaine, cyclizine, desipramine, dihydroergotamine, dyxirazine, dosulepin, ergotamine, ethambutol, etofylline, mefruside, metoclopramide, phenazone, phentermine, phenytoin, sulfamethoxazole, sulfamoxole, sulthiame and tetracycline) on seven electrospray ionization instruments using 18 different instrumental configurations for fragmentation. For 1222 spectra (99.3%), the correct compound was retrieved as the best matching compound. Classified matches (matches with ‘relative average match probability’ >40.0) were obtained for 1207 spectra (98.1%). This high percentage of correct identifications clearly supports the hypothesis that the tandem mass spectral library approach tested is a robust and universal identification tool. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Fruitbodies of the genus Hygrophorus (Basidiomycetes) contain a series of anti-biologically active compounds. These substances named hygrophorones possess a cyclopentenone skeleton. LC/ESI-MS/MS presents a valuable tool for the identification of such compounds. The mass spectral behaviour of typical selected members of this group under positive and negative ion electrospray conditions is discussed. Using the ESI collision-induced dissociation (CID) mass spectra of the [M + H]+ and [M - H]- ions, respectively, the compounds can be classified with respect to the substitution pattern at the cyclopentenone ring and the type of oxygenation at C-6 (hydroxy/acetoxy or oxo function) of the side chain. The elemental composition of the fragment ions was determined by ESI-QqTOF measurements. Thus, in case of the negative ion CID mass spectra an unusual loss of CO2 from the deprotonated molecular ions could be observed.  相似文献   

12.
Liquid chromatography coupled with negative and positive electrospray ionisation (ESI) tandem mass spectrometry (MS/MS) and diode-array detection (DAD) was used for determination of phenols in rose hip (Rosa canina) extract. ESI mass spectra of the chromatographically separated phenols gave the molecular weight of the compounds through prominent [M - H](-) ions for most of the compounds and M(+) ions for the anthocyanins. Collision induced dissociation (CID) of the [M - H](-) (or M(+)) precursor ions yielded product ions which determined the molecular weight of the aglycones. In-source fragmentation followed by CID of the resulting deprotonated aglycone ([A - H](-)) provided product ions for the identification of the unconjugated phenols. The identification was based on comparison with product ion spectra of commercial standards. UV-diode-array spectra were used for identity confirmation. This combined approach allowed the identification in rose hip extract of an anthocyanin, i.e. cyanidin-3-O-glucoside, several glycosides of quercetin and glycosides of taxifolin and eriodictyol. Phloridzin was identified, and several conjugates of methyl gallate were also found, one of which was tentatively identified as methyl gallate-rutinoside. Catechin and quercetin were found as the aglycones in the extract.  相似文献   

13.
A study of the fragmentation and ion formation of three major families of pesticides (including herbicides, insecticides, and fungicides) by liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS) and liquid chromatography/quadrupole time-of-flight mass spectrometry (LC/Q-TOF-MS) was carried out using positive electrospray ionization (ESI) and the results compared with those by gas chromatography (GC)/TOF-MS with electron ionization (EI) in order to test the validity of the even-electron rule in electrospray ionization. First, the majority of the fragmentations by positive ion ESI were even electron (EE) ions (93% of the fragment ions). Secondly, the formation of odd-electron (OE) fragment ions was greater with EI, where the fragment ions were present in a ratio of approximately 1:2 (35% OE ions and 65% EE ions). Thirdly, in-source collision-induced dissociation (CID) fragmentation by LC/TOF-MS and CID fragmentation in the collision cell by LC/Q-TOF-MS/MS resulted in 95% of the fragment ions being identical between the two types of fragmentation. As ESI in the positive ion mode yields an EE precursor ion (normally a protonated molecule), this commonly leads to EE fragment ions by elimination of molecules - a process called the even-electron rule. Neutral radical losses were less common in ESI but were common in the EI spectra of the same compounds. The structures that did lead to OE ions in ESI (exceptions to the even-electron rule approximately 7% of all ESI ions) favored electronegative radical losses in approximately the following order: .SO(2)CH(3), .NO(2), .CH(3), .Cl, .SCH(3), .CH(2)CH, and .OH.  相似文献   

14.
Structure analyses of underivatized neutral lacto oligosaccharides are systematically performed by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (UV-MALDI TOF MS) and UV-MALDI ion-trap time-of-flight mass spectrometry (ion-trap/TOF MS) acquired in negative-ion mode. Interestingly, their fragmentation significantly differ each other. In postsource decay (PSD) in UV-MALDI TOF MS, cross-ring cleavage at the reducing terminal predominates. On the other hand, glycosyl bond cleavage (C-type fragmentation) takes place preferentially in collision induced dissociation (CID) in UV-MALDI ion-trap/TOF MS. The cross-ring cleavage in PSD similar to that in in-source decay occurs via a prompt reaction path characteristic of the UV-MALDI process itself. The product ion spectra of UV-MALDI ion-trap/TOF MS are similar to the electrospray ionization (ESI) ion-trap or quadrupole/TOF CID product ion spectra. During ion-trap/TOF MS experiments, the deprotonated molecular ions survive for several tens of milliseconds after CID event because the high internal energy chlorinated precursor ions are cooled by collisional cooling in the ion trap. The results obtained suggest that the PSD from the chlorinated precursor ion in UV-MALDI TOF MS might proceed as a two-step reaction; in the first, a high internal energy deprotonated molecular ion is generated as a reaction intermediate during the flight in the drift tube, and in the second, the rapid decomposition from the deprotonated molecular ion takes place.  相似文献   

15.
The electrospray ionisation (ESI) of selected coumarin derivatives and their subsequent fragmentation using an ion trap mass spectrometer have been investigated. Sequential product ion fragmentation experiments (MS(n)) were performed in order to elucidate the degradation pathways for these compounds. A comparison was also made between these ESI spectra and those obtained under electron impact (EI) conditions. The data presented in this paper provides useful information on the effect of different substituents on the ionisation/fragmentation processes and can be used in the characterisation of these compounds.  相似文献   

16.
In order to develop a robust and easy-to-use technique for characterization of bacterial polysaccharides, a pseudo-hydrolysis strategy was investigated. Based on in-source collision-induced dissociation, polysaccharide molecular ions were fragmented within the orifice-skimmer region of an electrospray ionization (ESI) mass spectrometer. The fragment ions thus generated were then analyzed similarly to the conventional ESI mass spectrometry approach. MS/MS scanning was applied to obtain product-ion spectra of the primary fragments for sequencing. To further improve the sensitivity and separation of polysaccharides from other components in the samples, a pressure-assisted capillary electrophoresis/mass spectrometry (CE/MS) system was employed. Using bacterial polysaccharides as model compounds, the mass spectra obtained for polysaccharide repeating units generated through chemical hydrolysis and in-source fragmentation were directly compared, both in positive and negative ion modes. With the additional separation of impurities provided by CE, the success of this technique has been demonstrated for structural analysis of O-chain polysaccharides (O-PS) and capsular polysaccharides (CPS). In-source fragmentation was applied to promote the formation of structurally relevant repeating units of heterogeneous CPS that would remain undetected using conventional ESI conditions. This approach was proven to be particularly useful for probing the subtle structural differences in monosaccharide composition and functionalities arising across bacterial serotypes.  相似文献   

17.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry can yield important structural information on organic compounds which can aid in their identification. However, differences in experimental conditions may have a strong effect on the degree of product ion formation and therefore on the features observed in product ion spectra. For this reason, a common approach for library building is the acquisition of several spectra, typically between 5 and 10, each at a different collision energy level. In this study, the use of an alternative approach was investigated, where a tuning point protocol was applied to tune the instruments in an attempt to standardise CID conditions prior to data acquisition. With this approach, the acquisition of a single mass spectrum was sufficient. The stability of the tuning point was investigated and the choice of a commercially available search package to assess spectral comparability was discussed. Finally, the product ion spectra of 33 compounds were acquired on twelve tandem-in-space instruments, including nine triple quadrupoles, one hybrid triple quadrupole linear ion trap and two quadrupole time-of-flight mass spectrometers, resulting in 2178 spectral comparisons being carried out. The results from the spectral comparisons suggest that the use of a tuning point enables the standardisation of the experimental conditions that affect the degree of product ion formation. Indeed, 84.5% of the comparisons demonstrated a good degree of spectral agreement with match scores greater than 700, which we believe is the minimum score for a tentative library match.  相似文献   

18.
Fragmentations of three triphenylethylene compounds (toremifene and its two metabolites) with different functional side-chain groups (alcohol, acid and amine) were studied. The compounds were dissociated by collision-induced dissociation (CID) in the interface region of an electrospray ionization source (ESI(+)) and in the collision cell of a triple quadrupole mass spectrometer. Fragmentation pathways for these molecules are proposed, based on accurate mass measurements of in-source fragment ions and MS/MS experiments using product and precursor ion scanning. The side-chain functional groups were found to strongly affect the fragmentations of the molecular ions. The fragmentation pathways of the protonated molecule and sodium ion adduct were quite similar, but the subsequent stabilities of certain common fragments were surprisingly different.  相似文献   

19.
Multistage mass spectrometry, as implemented using low-energy collision-induced dissociation (CID) analysis in three-dimensional (3D) quadrupole ion traps (QITs), has become a powerful tool for the investigation of protein glycosylation. In addition to the well-known combination of QITs with electrospray ionization (ESI), also a matrix-assisted laser desorption/ionization--quadrupole ion trap--reflectron time-of-flight (MALDI-QIT-rTOF) mass spectrometer has recently become available. This study systematically investigates the differences between these types of instrument, as applied to characterization of glycopeptides from human antithrombin. The glycopeptides were obtained by tryptic digestion followed by lectin-affinity purification. Some significant differences between the ESI-QIT and MALDI-QIT-rTOF approaches appeared, most of them are causally related to the desorption/ionization process. The combination of a vacuum MALDI source with an ion-trap analyzer accentuates some characteristic differences between MALDI and ESI due the longer time frame needed for the trapping process. In contrast to ESI, MALDI generated ions that exhibited considerable metastable fragmentation during trapping. The long time span of the QIT process (ms range) compared with that for conventional rTOF experiments (micros range) significantly magnified the extent of this metastable fragmentation. With the investigated glycopeptides, a complete depletion of the terminal sialic acids of the glycopeptides as well as a variety of other fragment ions was already found in the MS1 spectra from the MALDI-QIT-rTOF instrument. The positive ion low-energy CID spectra (MS2) of the selected glycopeptides obtained using the two different QIT equipped instruments were found to be quite similar. In both approaches, fragmentation of the glycan and peptide structures occurred sequentially, allowing unambiguous sequence determination. In the case of ESI-QIT-MS, fragmentation of the glycan structure occurred at the MS2 stage and fragmentation of the peptide structure was obtained only at the MS3 stage, which indicates the necessity of multistage CID experiments for complete structure elucidation. The MALDI-QIT-rTOF instrument yielded both kinds of fragments at the MS2 stage but without mutual interference.  相似文献   

20.
Zofenopril (1) is a new ACE inhibitor, used in therapy for hypertension and post-myocardial infarction. The protonated quasi-molecular ion (m/z 430) of 1, obtained under positive electrospray ionization conditions, loses a benzoic acid molecule (m/z 308), which in turn decomposes via loss of CO (m/z 280) when low-energy collisional-induced dissociation (CID) and in-source experiments are performed. This rearrangement is the main fragmentation process and can be observed both in-source and in the product ion tandem mass spectra, using either an ion trap or a triple quadrupole instrument. Other known diastereoisomers of 1, an impurity with an acetyl in the place of the benzoyl group (2) and an impurity with two propanoyl chains in series (3), give the same rearrangement. On the other hand, the mass spectra of the methyl ester (4) and an impurity with two proline moieties (5) do not show this unusual fragmentation. Time-resolved CID spectra of 1 show that the rearrangement occurs after about 2 ms, a time scale comparable to those of the other non-rearrangement cleavages. These experiments suggest a conformation in the gas phase for 1 in which the benzoyl group is close to the hydroxyl of the carboxylic acid group, from which the rearrangement could readily occur. Since compounds 4 and 5 do not show the same behaviour, the presence of a carboxylic acid in the proline ring seems to play a crucial role in the rearrangement, probably due to an intramolecular hydrogen bond. To confirm this hypothesis, deuterium exchanges in mass spectrometric experiments and a conformational analysis via computational methods were performed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏