首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
A method for the determination of phenoxyalkanoic acids and other polar compounds in environmental water samples without pH adjustment before extraction has been developed. Recoveries were calculated from 500 ml of milliQ water spiked at the level of 0.5 ng/ml using solid-phase extraction (SPE) and HPLC-DAD. Different SPE materials (RP-C18, ENV+, ENV+-C8, SAX and Oasis HLB) were tested. After method optimization, 15 of the 16 compounds studied could be extracted with recoveries better than 70% on the most suitable copolymeric poly(divinylbenzene-co-N-vinylpyrrolidone) material (Oasis HLB cartridges).  相似文献   

2.
Two GC-MS methods, based on the application of N,O-bis(trimethylsilyl)trifluoroacetamide-derivatization-GC-MS (selected-ion monitoring) and GC-MS-MS without derivatization, respectively, were optimised and applied to the determination of a group of five selected endocrine disrupting compounds (EDCs) in wastewaters. Both methods included solid-phase extraction with Oasis HLB cartridges allowing an enrichment factor for wastewater samples of 100-fold. The investigated EDCs were estrone, 17beta-estradiol, 17alpha-ethynylestradiol, 4-tert-octylphenol and bisphenol A. Results obtained from the validation studies yielded comparable results in both cases. Recoveries in spiked wastewaters at 50 ng/l were higher than 90% for all the compounds, except for 4-tert-octylphenol (75%). Repeatability and reproducibility were adequate, varying from 1.6 to 14%, except for estrone which reproducibility was 28% when the derivatization-GC-MS method was applied. Limits of detection calculated ranged from 2.5 to 27.5 ng/l with differences between both methods from 1.1 (estrone) to 10.4 (bisphenol A) times. Both methods were successfully applied to the analysis of the target compounds in sewage treatment plant influents and effluents. Traces of bisphenol A, 4-tert-octylphenol, estrone and 17beta-estradiol were detected at concentration levels ranging from 13.3 to 1105.2 ng/l.  相似文献   

3.
This study describes an in‐depth investigation of the parameters involved in the solid‐phase extraction performance of perfluoroalkylated compounds (seven carboxylates and one sulfonate), particularly with sea water samples. The two most popular sorbents, Oasis WAX and Oasis HLB, were considered and it was observed that the high ionic strength of sea water may impair solid‐phase extraction recoveries. In the final protocol, Oasis HLB cartridges were selected, incorporating a 10% methanol clean‐up step before elution with methanol, since less matrix effects were obtained. The proposed method allows successful recoveries, higher than 71%, and relative standard deviations lower than 20%. It also provides excellent limits of detection values between 0.01 and 0.21 ng/L. Finally, the method was applied to fresh and sea water samples, where several perfluoroalkylated compounds were found at concentrations ranging between 0.16 and 64 ng/L. In the case of perfluorooctane sulfonate, recently included in the Water Frame Directive, its concentration reached the highest values among the perfluoroalkylated compounds measured (64 ng/L in river samples).  相似文献   

4.
A new, single-step extraction and purification method based on matrix solid-phase dispersion (MSPD) was developed to determine 17 polycyclic aromatic hydrocarbons (PAHs) in sewage sludge samples. The MSPD method consists of sample homogenisation, exhaustive extraction and clean-up by a single process. The different operational parameters of the method, such as the type of dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated. Reversed-phase (C18) and polymeric (Oasis HLB and Oasis MAX) materials, as well as normal phase sorbents (Florisil, silica, neutral alumina) and an inert support (sand) were tested to assess the sorbents effect on the yield and selectivity of the MSPD process. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection.Quantification limits obtained for all of these considered compounds (between 0.0001 and 0.005 μg g−1 dry mass) were well below of the limits recommended in the EU. The extraction yields for the different compounds obtained by MSPD ranged from 76.3% to 103.6%. On the other hand, the extraction efficiency of the optimised method is compared with that achieved by microwave-assisted extraction and the method was applied to the analysis of real sewage sludge samples. A certified reference material (sewage sludge (BCR 088)) and a reference material (sewage sludge (RTC-CNS312-04)) were used to validate the proposed method.  相似文献   

5.
In this study an analytical procedure of solid-phase extraction (SPE) followed by gas chromatography mass spectrometry (GC-MS) was elaborated and validated for simultaneous determination of 11 acidic, neutral and basic emerging contaminants in wastewater. The most frequently used pharmaceuticals were studied, i.e. five anti-inflammatory drugs – ibuprofen, diclofenac, ketoprofen, naproxen and salicylic acid, an antiepileptic drug carbamazepine, clofibric acid, antibacterial triclosan, a plasticiser bisphenol A and two β-blockers – propranolol and metoprolol. Sample enrichment was performed using Oasis HLB sorbent. Sample pH and sorbent washing step during the solid-phase extraction were optimised on real wastewater samples. Recoveries of the most polar acidic compounds diminished substantially when the alkalinity of the sample loaded into the cartridge increased. Thus finally wastewater was extracted at pH 2.0. Before elution, sorbent was washed subsequently with 5% methanol in water and n-hexane, which resulted in best recoveries of most of the target compounds and reduced a co-elution phenomena with respect to β-blockers. The optimised method was successfully applied to influent and effluent samples from wastewater treatment plant, Krakow, Poland. All target compounds except propranolol were identified in wastewater at a concentration up to 12.8 µg L?1.  相似文献   

6.
A new hypercrosslinked polymer (HXLGp) with hydrophilic character due to the presence of hydroxyl moieties has been tested as a sorbent for the solid-phase extraction (SPE) of several polar compounds from water samples. This new sorbent enables the on-line extraction of 300 ml of sample with recoveries higher than 80% for polar compounds such as oxamyl, methomyl or desisopropylatrazine (DIA). The HXLGp has also been compared to other commercially available sorbents such as Oasis HLB (hydrophilic macroporous), to hydrophobic hypercrosslinked resins and to a previously synthesized sorbent based on N-vinylimidazole-divinylbenzene. The results are consistently better with the new synthesized sorbent. The method was successfully applied to the on-line SPE-HPLC of tap and river water samples. The validation with river water samples provided good linearity range and detection limits between 0.03 for methomyl and 4-nitrophenol (4NP) to 0.2 microg l(-1) for phenol (Ph).  相似文献   

7.
An integrated analytical method for the simultaneous determination of 4-n-nonylphenol (4-n-NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), bisphenol A (BPA) and triclosan (TCS) in wastewater (dissolved and particulate phase) and sewage sludge was developed based on gas chromatography-mass spectrometry. Chromatographic analysis was achieved after derivatization with bis(trimethylsilyl)trifluoroacetamide (BSTFA). Extraction from water samples was performed by solid-phase extraction (SPE). The optimization of SPE procedure included the type of sorbent and the type of the organic solvent used for the elution. Referred to solid samples, the target compounds were extracted by sonication. In this case the optimization of the extraction procedure included the variation of the amount of the extracted biomass, the duration and the temperature of sonication and the type of the extraction organic solvent. The developed extraction procedures resulted in good repeatability and reproducibility with relative standard deviations (RSDs) less than 13% for all the tested compounds for both types of samples. Satisfactory recoveries were obtained (>60%) for all the compounds in both liquid and solid samples, except for 4-n-NP, which gave recoveries up to 35% in wastewater samples and up to 63% in sludge samples. The limits of detection (LODs) of the target compounds varied from 0.03 (4-n-NP) to 0.41 microg l(-1) (NP2EO) and from 0.04 (4-n-NP) to 0.96 microg kg(-1) (NP2EO) for liquid and solid samples, respectively. The developed methods were successfully applied to the analysis of the target compounds in real samples.  相似文献   

8.
A highly sensitive and selective method for simultaneous determination of some hydroxyl group-containing endocrine disruptors, including bisphenol A (BPA), bisphenol B (BPB), bisphenol E (BPE), bisphenol F (BPF) and 4-nonylphenol (4-NP), was developed. The method consists of precolumn derivatization of the analytes, solid-phase extraction (SPE) and subsequent chromatographic analysis by high-performance liquid chromatography (HPLC) with fluorescence detection. 4,4'-Cyclohexylidenebisphenol (BPZ) was used as an internal standard. Derivatization was carried out using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label. Parameters of the derivatization reaction (temperature, time, concentration of reagent, stability, etc.) and of the solid-phase extraction (recovery, solvent, etc.) were studied in detail. Detection limits of compounds studied in standard solutions ranged from 0.08-1.3 ppb (ng/ml). The proposed method was successfully applied to plastic samples; BPA was found in both polycarbonate and polyvinyl chloride plastics, while 4-NP was found in plastics made of polyvinyl chloride and another polymer.  相似文献   

9.
This article presents an analytical method based on solid-phase extraction (SPE) and gas chromatography coupled with mass spectrometry for the simultaneous determination of the most frequently used acidic pharmaceutical residues, ibuprofen, diclofenac, naproxen and ketoprofen (KFN), and phenolic endocrine disruptors, bisphenol (BPA), triclosan (TCS), nonylphenol, nonylphenol monoethoxylate and nonylphenol diethoxylate, in wastewater and sewage sludge samples. In the first phase of the study, each compound has been characterized individually and afterwards in mixture as a trimethylsilyl derivative in order to identify the characteristic ions (m/z ratio) constituting the mass spectrum and to choose the ions for quantification and confirmation. Subsequently, derivatization was evaluated by testing different variables such as the volume of the derivatization solvent bis(trimethylsilyl)trifluoroacetamide and the effect of each catalyst, pyridine and 1% trimethyl chlorosilane, in the derivatized solution. For the analysis of wastewater samples, two commercial SPE cartridges, C18 and Oasis HLB, were compared for their extraction efficiency of the target compounds. The key parameter of extraction procedure included the effect of pH (2.5, 5.3 and 7) of the loading solution. For solid samples, parameters such as the extracted biomass, the volume of the extraction organic solvent and the effect of matrix interferences in chromatographic analysis were evaluated. By using C18 cartridges as purification procedure and ultrasound sonication, satisfactory mean relative recoveries with BPA-d16 and meclofenamic acid as surrogates were obtained ranging from 91% to 117% for wastewater and 84% to 107% for sewage sludge samples. Nine-point calibration of the standard mixture was performed by linear regression analysis with a correlation coefficient >0.99 for all the tested compounds. Limits of detection for the developed methods were established between 0.3 (KFN) and 14.8 (BPA) ng L−1, and 15.0 (TCS) and 32.9 (BPA) ng g−1 for wastewater and sewage sludge, respectively. Application to real samples of the wastewater treatment plant in Athens, the capital of Greece, demonstrated the presence of all tested compounds in most of the samples.  相似文献   

10.
This paper describes the development of a multi-residue method for the determination of 36 emerging organic pollutants (26 biocides, 5 UV-filters and 5 benzothiazoles) in raw and treated wastewater, activated sludge and surface water using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The target analytes were enriched from water samples adjusted to pH 6 by solid-phase extraction (SPE) on Oasis HLB 200 mg cartridges and eluted with a mixture of methanol and acetone (60/40, v/v). Extraction of freeze-dried sludge samples was accomplished by pressurized liquid extraction (PLE) using a mixture of methanol and water (50/50, v/v) as extraction solvent followed by SPE. LC–tandem MS detection was compared using electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in positive and negative ionization mode. ESI exhibited strong ion suppression for most target analytes, while APCI was generally less susceptible to ion suppression but partially leading to ion enhancement of up to a factor of 10. In general, matrix effects could be compensated using stable isotope-labeled surrogate standards, indicated by relative recoveries ranging from 70% to 130%. In wastewater, activated sludge and surface water up to 33 analytes were detected. Maximum concentrations up to 5.1 and 3.9 μg L−1 were found in raw wastewater for the water-soluble UV-filters benzophenone-4 (BZP-4) and phenylbenz-imidazole sulfonic acid (PBSA), respectively. For the first time, the anti-dandruff climbazole was detected in raw wastewater and in activated sludge with concentrations as high as 1.4 μg L−1 and 1.2 μg g TSS−1, respectively. Activated sludge is obviously a sink for four benzothiazoles and two isothiazolones, as concentrations were detected in activated sludge between 120 ng g TSS−1 (2-n-octyl-4-isothiazolin-3-one, OIT) to 330 ng g TSS−1 (benzothiazole-2-sulfonic acid, BTSA).  相似文献   

11.
In this study five different commercial sorbents C18, SCX, CN, Certify and Oasis HLB were compared for the solid-phase extraction of potato glycoalkaloids. The recoveries were determined using alpha-solanine, alpha-chaconine and alpha-tomatine, which contained dehydrotomatine as an impurity, as standard compounds. The samples were analysed by reversed-phase liquid chromatography under gradient elution conditions using a Zorbax Rx-C18 column and acetonitrile-25 mM triethylammonium phosphate buffer (pH 3.0) as the mobile phase. The highest recovery (approximately 100%) was achieved with Oasis HLB (60 mg) cartridges. An acetic acid extract of wild Solanum brevidens leaf material was used for the testing of a clean-up procedure. The SCX proved to be the most selective and efficient for removing the undesired components from the leaf extract.  相似文献   

12.
The present work describes the development of a highly sensitive analytical method based on liquid chromatography-quadrupole linear ion trap-mass spectrometry (LC-QqLIT-MS) for the determination of nine sulfonamide antibiotics and one N4-acetylated metabolite in environmental waters (wastewater, surface water and groundwater) and bottled mineral water. Special emphasis was devoted to the elimination of matrix components during solid-phase extraction (SPE) by the evaluation of three different extraction/purification strategies: single cartridges (Oasis HLB and Oasis MCX) and tandem (TD) extraction (combination of both). The method developed proved to be suitable for sulfonamide determination in all kinds of waters tested. The method was shown to be linear in a wide concentration range, with correlation coefficients higher than 0.999 for all compounds except for sulfadimethoxine (R2 0.997). The overall instrumental repeatability was satisfactory, with the exception of the metabolite (RSD 34%). Method limits of detection achieved for sulfonamides were in the range 0.01-1.13 ng L(-1) and for the metabolite 0.08-461 ng L(-1). Recovery rates were estimated at 500 ng L(-1) spike level in the four water matrices selected. The highest recovery achieved in all matrices was that corresponding to the Oasis HLB cartridge. In environmental waters, recovery values obtained were higher than 61% for the surface water and, in general, higher than 90% for groundwater and wastewater. Bottled mineral water exhibited recovery rates higher than 92%, with the exception of sulfamethoxypiridazine (82%) and sulfapyridine (86%) In order to demonstrate the applicability of the developed method, several water samples were analyzed. Results evidenced the requirement for consideration of N4-acetylated metabolites of sulfonamides in environmental residue analysis to avoid the underestimation of removal rates of such pharmaceutical compounds during wastewater treatments.  相似文献   

13.
This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norfloxacin and penicillin G/procaine. Five different SPE materials (Strata‐X, Strata‐X‐C, Strata SDB‐L, Strata C8 and Strata C18) from Phenomenex were compared with Oasis HLB with a view to obtaining the best cartridges for all pharmaceuticals investigated. Extraction efficiency was determined by HPLC with diode array detection (DAD). HPLC‐DAD separation and quantification of the selected pharmaceuticals were carried out under gradient elution by a binary mixture of 0.01 M oxalic acid and ACN based on cyano modified column (LiChrosphere 100 CN) from Merck. Strata‐X provided the best results in the preconcentration of 100 mL water samples, yielding average pharmaceutical recoveries of higher than 90%, except for sulfaguanidine (76.1%). The developed Strata‐X‐HLPC‐DAD method was validated and applied, for the efficient investigation of reverse osmosis/nanofiltration membranes and for the removal of these eight pharmaceuticals from the production wastewater samples. NF90 and XLE membranes were shown to be the best for the rejection of all investigated pharmaceuticals.  相似文献   

14.
Two 4-vinylimidazole-divinylbenzene (4VIm-DVB) polymers were synthesized and applied as sorbents for on-line solid-phase extraction (SPE) followed by liquid chromatography for analyzing polar compounds in aqueous samples. The new sorbents (4VIm-DVB) were compared to another sorbent that had been previously synthesized by our group (N-vinylimidazole-divinylbenzene (NVIm-DVB)) and to the commercial OASIS® HLB and StrataTM X. All the sorbents enabled 100 mL of sample to be on-line concentrated with good recoveries for the studied polar compounds. Real water samples were analyzed using NVIm-DVB and OASIS® HLB as SPE sorbent, for which the best results were obtained.  相似文献   

15.
A procedure for the determination of six natural and synthetic estrogens (diethylstilbestrol, estrone, 17beta-estradiol, mestranol, 17alpha-ethinylestradiol and estriol) in water samples is described. Samples, up to 2000 ml, were concentrated using Oasis HLB solid-phase extraction cartridges. Analytes were derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide and determined by GC-MS or GC-MS-MS. The reactivity of several silylation reagents versus aliphatic and aromatic hydroxyl groups contained in the structure of the selected analytes was evaluated. Influence of parameters such as sample pH, nature of the water samples and derivatization conditions on the performance of the whole analytical procedure was systematically studied. Under optimal conditions, quantification limits between 1 and 3 ng/l were achieved for the determination of the considered estrogens in sewage water.  相似文献   

16.
This article discusses the preparation of different polymeric sorbents for solid phase extraction. Various monomers like acrylamide, methacrylic acid and 4-vinylpyridine (VP), cross-linkers such as divinylbenzene (DVB) and ethyleneglycoldimethacrylate (EDMA), porogens like tetrahydrofuran (THF) and dimethylsulphoxide (DMSO) / acetonitrile (ACN) with different ratios were investigated in order to optimize recoveries. Resulting polymers were characterized through scanning electron microscope (SEM) and compared with Oasis HLB (Waters, MA, USA) and Strata-X (Phenomenex, Torrance, USA) on the basis of extraction performance, recovery efficiency and loading capacity. Sample applied was a mixture of flavonoid standards (rutin, myricetin, luteolin, quercetin, apigenin and kaempferol). HPLC hyphenated with PDA was used for the analysis of samples. Results showed that among the prepared SPE materials, 4-VP-co-EDMA produced best results. Comparison of the produced polymers with of Oasis HLB and Strata-X resulted in comparable efficiencies; especially the polymer 4-VP-co-EDMA gave almost similar results for all analytes to those of commercially available SPE materials. A general trend of decrease in retention efficiency with increase in polarity has been observed in both synthesized and already available SPE materials. The newly synthesized polymeric materials can be employed as SPE sorbents for efficient extraction of polyphenolic compounds especially for flavonoid aglycons.  相似文献   

17.
A new method for determining the endocrine disrupting substance 4-nonylphenol (technical grade = mixture of isomers, 4-NP) from water samples has been developed by using 4-(2,6-dimethylhept-3-yl)phenol (4-sec-NP) as model compound. This branched monoalkylphenol is shown to serve as internal standard (IS) for the determination of technical 4-nonylphenol. To the best of our knowledge, 4-(2,6-dimethylhept-3-yl)phenol (racemic mixture) is a newly synthesized 4-nonylphenol isomer and has not been described elsewhere. Recoveries have been determined by analyzing spiked water samples from distilled water, river water and wastewater. Following acetylation, the compounds were enriched via solid phase extraction (SPE). Analyses of the compounds were performed by capillary column gas chromatography/mass spectrometry (GC/MS), operating in selected ion-monitoring (SIM) mode. The recovery of technical 4-NP using either the newly prepared 4-sec-NP or 4-n-nonylphenol (4-n-NP) as IS have been compared. 4-sec-NP showed slightly better results. However, in the first series of experiments using wastewater, the yields for the derivatization of the two standard compounds were remarkably different. The yield for derivatization of 4-n-NP was approximately 20%, probably due to the difficult matrix of the wastewater. In contrast, the yield for the derivatization of 4-sec-NP was considerably higher (approximately 63%). This problem can be solved by increasing the concentration of the reagent used for derivatization. For better control of the clean-up process, we recommend application of 4-sec-NP as internal standard, at least in water samples with complex matrices (e.g., high content of hydroxylated compounds).  相似文献   

18.
An analytical method based on gas chromatography-mass spectrometry (GC-MS) has been developed to simultaneously determine selected acidic and neutral pharmaceuticals and endocrine-disrupting substances in surface and tap water. Solid-phase extraction (SPE) with Oasis HLB cartridges is followed by derivatization of the target analytes in the eluted extract. Derivatization was systematically optimized by employing a factorial experimental design. More specifically a central composite design was applied to search for the optimal conditions of the derivatization process and it was demonstrated that N-methyl-N-tert-butyl-dimethysilyl-trifluoroacetamide (MTBSTFA) had a better overall performance compared to N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA). The influence of solvent ratios and elution volumes while using SPE were also studied using a factorial design. The method was developed successfully for most of the selected compounds [i.e. ibuprofen, salicylic acid, gemfibrozil, naproxen, triclosan, propranolol, diclofenac, carbamazepine, 4-octylphenol (OP), 4-nonylphenol (NP), nonylphenol-monoethoxylate (NP1EO), nonylphenoxyacetic acid (NP1EC), estrone (E1), and 17alpha-ethinyloestradiol (EE2)]. Relative recoveries for spiked river and tap water ranged from 47 to 130% and 60-109%, respectively. Typical limits of detection were less than 5 ng/L in tap water and less than 10 ng/L in river water. Twelve target compounds were detected in river and tap water samples using the developed method. This method is currently used in bench-scale drinking water treatment studies.  相似文献   

19.
The analysis of alkyl methylphosphonic acids (AMPAs) constitutes an important subject for verifying the compliance to the Chemical Weapons Convention (CWC). Indeed, alkyl methylphosphonic acids are the degradation products of V and G nerve agents such as VX, sarin or soman. Lowering the limits of detection of analytical methods for complex aqueous matrices implies the introduction of concentration and clean-up steps in the whole analytical process. Therefore a molecular imprinted polymer (MIP) has been previously developed for the selective extraction and the concentration of the alkyl methylphosphonic acids. Unfortunately, the selective retention process on this MIP has involved the development of hydrogen bonds and so does not allow the direct percolation of aqueous samples. A change of solvent is then necessary and can be performed using solid-phase extraction (SPE) with conventional non selective hydrophobic sorbents. Two polymeric sorbents, Oasis HLB and HR-P resins, were selected for their high specific surface area. The extraction recoveries obtained on both sorbents were compared and the Oasis HLB sorbent was further selected and used for the percolation of acidified aqueous samples. An optimised SPE procedure was then applied to concentrate an aqueous soil extract spiked with isobutyl methylphosphonic acid (iBMPA) and cyclopentyl methylphosphonic acid (cPMPA) that was further cleaned-up by passing through the MIP. The resulting LC-MS full scan chromatograms highlight the clean-up effect of the SPE-MIP association by the removal of the matrix substances and the preservation of 95% of the compounds of interest.  相似文献   

20.
Capillary zone electrophoresis (CZE) in an organic medium was used to analyse triazines at sub-ppb concentration levels in natural waters after a preconcentration step using conventional C18 cartridges and new Oasis HLB devices. With both sorbents, satisfactory results were obtained on analysing deionized water. However, on analysing natural waters, both sorbents showed very different types of behaviour. The different variables affecting the elution of both sorbents were studied, resulting in the choice of Oasis HLB as the most suitable for later separation by CZE in non-aqueous medium. Combination of a preconcentration step with electrokinetic injection revealed that capillary electrophoresis with simple UV detection can also be used satisfactorily for the quantification of micropollutants in natural waters. The detection limits obtained varied between 0.01 and 0.05 microg l(-1), depending on the type of matrix analysed. The day-to-day precision varied between 0.9% and 2.3%, expressed as the relative standard deviation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号