The adsorptive properties and electrochemical behavior of ketoconazole, an oral anti-fungal agent, are demonstrated at a glassy carbon electrode. The adsorption of the compound obeys the Frumkin isotherm with an interaction factor (alpha) of 0.985 and adsorptive coefficient (beta) of 1.98 x 10(6) L mol(-1). The Gibbs energy of adsorption (deltaG) is -3.59 x 10(4) J mol(-1) at 25 degrees C. A very sensitive electroanalytical method has been developed for determination of the drug with a detection limit of 4.0 x 10(-11) mol L(-1). Relationships between stripping current and concentration of ketoconazole were linear in the range 10(-6)-10(-10) mol L(-1) with different preconcentration periods. The method has been used to measure the ketoconazole content of tablets.  相似文献   

2.
Shamsipur M  Farhadi K 《The Analyst》2000,125(9):1639-1643
The oxidation of ketoconazole on a bare carbon paste electrode was studied voltammetrically. The results indicated that the process is irreversible and controlled by an adsorption-extraction process which allows the accumulation of the drug at the electrode surface. After the optimization of solution pH, accumulation variables and instrumental parameters, sensitive differential pulse and linear sweep voltammetric peaks were obtained whose peak currents were linearly proportional to the ketoconazole concentration over the ranges 2.4 x 10(-8)-4.8 x 10(-7) and 9.1 x 10(-7)-1.0 x 10(-5) M, respectively. Based on these findings, a simple procedure was developed for the determination of ketoconazole in human urine and formulations.  相似文献   

3.
用伏安法研究了维生素B6(VB6)在碳纤维微电极(CFME)上的电化学行为及其测定。以0.1 mol/L的邻苯二甲酸氢钾(pH 5)的缓冲液为底液,在最佳实验条件下,VB6在0.94 V(vs,SCE)的氧化峰峰电流与VB6在5.0×10-6~8.0×10-4mol/L范围内呈良好的线性关系,检出限为1.0×10-6mol/L(S/N=3)。方法用于药剂中的VB6的分析。  相似文献   

4.
在0.3mol·L-1KH2PO4-Na2HPO4(pH6.40)底液中,加雷沙星(Garenoxacin,简称GRX)在汞电极上有一线性扫描还原峰,峰电位EP=-1.12V(vsAg/AgCl),该峰具有明显的吸附性;吸附粒子为GRX中性分子,测得GRX在汞电极上的饱和吸附量Гs=3.92×10-11 mol·cm-2,每个GRX分子所占电极面积为1.94nm2,GRX在汞电极上的吸附符合Langmuir吸附等温式;测得吸附系数β=1.14×106,25℃时的吸附自由能ΔGθ=-29.62kJ·mol-1,电极反应电子数n=2,不可逆体系动力学参量αna=1.04,表面电极反应速率常量ks=0.25s-1;建立了吸附溶出伏安法测定GRX的最佳条件,方法的检出限为2.0×10-8 mol·L-1.  相似文献   

5.
The adsorptive and electrochemical behaviors of azithromycin were investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to +1.0 V. The resulting electrode showed good activity to improve the electrochemical response of the drug. An adsorptive stripping voltammetric method for the determination of azithromycin at an electrochemically activated glassy carbon electrode has been developed. Azithromycin was accumulated in phosphate buffer, pH 6, at a potential of +0.3 V (vs. Ag/AgCl electrode) for a certain time, and then determined by differential pulse voltammetry. The oxidative peak current at +0.82 V, at a scan rate of 20 mV s(-1), was a linear function of the concentration in the ranges of 0.25 - 2 microg mL(-1) and 1 - 10 microg mL(-1) using a 240 or 60 s(-1) preconcentration time, respectively. Application of the method to the determination of azithromycin in pharmaceuticals resulted in an acceptable deviation from the stated concentration. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine samples with satisfactory results. The peak current was linear with the drug concentration in the range of 0.5 - 3.5 microg per mL urine. The detection limit was 0.2 microg mL(-1) urine. The recovery levels of the method reached 96.3%.  相似文献   

6.
Zhou CL  Lu Y  Li XL  Luo CN  Zhang ZW  You JM 《Talanta》1998,46(6):1531-1536
A new method is described for the determination of antimony based on the cathodic adsorptive stripping of Sb(III) complexed with 2′,3,4′,5,7-pentahydroxyflavone(morin) at a static mercury drop electrode (SMDE). The reduction current of the adsorbed antimony complex was measured by 1.5th-order derivative linear-sweep adsorption voltammetry. The peak potential is at −0.51 V (vs. SCE). The effects of various parameters on the response are discussed. The optimized analytical conditions were found to be: supporting electrolyte, chloroacetic acid (0.04 mol/l, pH 2.3); concentration of morin, 5×10−6 mol/l; accumulation potential, −0.25 V (vs. SCE); scan rate, 100 mV/s. The limit of detection and the linear range were 7×10−10 mol/l and 1.0×10−93.0×10−7 mol/l Sb(III) for a 2-min accumulation time, respectively. This method has been applied to the determination of Sb(III) in steel and brass samples and satisfactory results were obtained. The adsorptive voltammetric characteristics and composition of the Sb(III)–morin complex were studied.  相似文献   

7.
The fluoroquinolone antibacterial agent ofloxacin was studied by adsorptive stripping voltammetry. Controlled interfecial accumulation of ofloxacin on a static mercury drop electrode in the hanging mercury drop mode provides high sensitivity. The linear concentration range was 0.079–197.5 μg ml?1 when using a 60-s preconcentration at ?1 V vs. Ag/AgCl in Britton-Robinson buffer of pH 6.00. The detection limit of ofloxacin was 1 ng ml?1. The precision is excellent with a relative standard deviation of ca. 0.75% at a concentration of 0.848 μg ml?1.  相似文献   

8.
氯冉酸可见分光光度法快速测定酮康唑   总被引:1,自引:0,他引:1  
建立了快速测定酮康唑含量的可见分光光度法。实验结果表明:酮康唑与氯冉酸在甲醇-丙酮混合溶剂中发生电荷转移反应,产物的最大吸收波长是524 nm,表观摩尔吸光系数为1.04×103L·mol-1·cm-1。酮康唑质量浓度在20~400 mg·L-1范围内服从比耳定律,相关系数为0.9995。当酮康唑浓度为200 mg·L-1时,五次测定结果的相对标准偏差为1.03%。测得荷移络合物的组成比和稳定常数分别为1∶1和3.9×103。回收率在98.0%以上。本方法简便、快速、准确,可作为制剂的质量控制方法。  相似文献   

9.
Mao Y  Hu J  Li Q  Xue P 《The Analyst》2000,125(12):2299-2302
In 0.005 mol dm-3 Tris-0.05 mol dm-3 NaCl buffer solution (pH 7.10), the electrochemical behavior of mitoxantrone was studied by linear-sweep voltammetry and cyclic voltammetry at a Co-carbon fiber ion implantation modified ultramicroelectrode. A sensitive reduction peak was obtained. The peak potential was -0.798 V (vs. SCE), the peak current was proportional to the concentration of mitoxantrone over the range of 2.0 x 10(-7)-6.0 x 10(6) mol dm-3 and the detection limit was 4.2 x 10(-8) mol dm-3. This method was applied to the direct determination of mitoxantrone in urine. Recoveries were in the range 95.4-105.8%. The reduction process was quasi-reversible with absorptive characteristics at a Co-C ultramicroelectrode. According to Laviron's theory, the electrode reaction rate constant ks and the electron transfer alpha of mitoxantrone were 4.4 s-1 and 0.48, respectively. The composition and depth distribution of elements on the surface of the Co-C ultramicroelectrode were determined by Auger electron spectroscopy. The experiments showed that Co was implanted into the surface of the carbon fiber, and the Co-C ultramicroelectrode had good stability and reproducibility.  相似文献   

10.
The synthesis of 5-Br-PADNm and the polarographic characteristics of this cobalt(II) complex are reported. In 0.15 mol/l sodium hydroxide cobalt(II) forms a 1 2 complex with 5-Br-PADNm. In the presence of 0.0030% Triton X-100 the complex gives an adsorptive polarographic wave at — 0.90 V, which is recommended for determination of cobalt down to 10–10 mol/l. The proposed method has been applied to the trace cobalt in natural water, hair and tea samples, with a relative error less than 10%.  相似文献   

11.
Duan JP  Chen GN  Chen ML  Wu XP  Chen HQ 《The Analyst》1999,124(11):1651-1655
It was found that estradiol valerate could be adsorbed at a mercury electrode under open circuit. The adsorptive and electrochemical behaviors of estradiol valerate on a static mercury electrode were investigated by cyclic voltammetry, linear scan voltammetry and chronocoulometry. Based on this, a sensitive and selective adsorptive stripping square-wave voltammetric method was developed for the determination of estradiol valerate based on the optimization of solution conditions and electrochemical parameters. It was found that in a Britton-Robinson buffer solution containing 18% alcohol (pH 9.5), estradiol valerate gave a sensitive reductive peak at potential -1.29 V (vs. SCE) and the peak current was linear with the concentration of estradiol valerate in the range 2.0 x 10(-8)-2.5 x 10(-6) mol L-1. The detection limit was 1.1 x 10(-8) mol L-1. The interference of some common steroid estrogens was examined and it was found that they did not interfere in the determination of estradiol valerate in the present system.  相似文献   

12.
吸附转移溶出伏安法测定氟罗沙星注射液含量   总被引:2,自引:0,他引:2  
氟罗沙星 (fleroxacin ,FLRX)是一种抗菌谱广 ,杀菌力强的三氟喹诺酮类抗菌药[1] 。FLRX含量的测定方式主要有HPLC法[2 ,3] 、紫外分光光度法[3,4 ] 和荧光分光光度法[5] 。本文研究FLRX在不同支持电解质中的电化学行为 ,发现其在石墨电极表面有很强的吸附性 ,在一定的电位下富集几分钟 ,电极冲洗后在底液中扫描 ,仍有很大的峰电流。在此基础上建立了吸附转移溶出伏安法(AdTSV) [6 ] 测定FLRX。方法的线性范围为 4~42 μg/ml,用于FLRX葡萄糖注射液中FLRX含量的测定 ,比其他方法灵敏、准确、…  相似文献   

13.
The adsorptive stripping voltammetric behavior of bovine insulin has been studied by both differential pulse and square-wave techniques, leading to analytical methodologies for its determination in aqueous samples and pharmaceutical preparations. The application of a square-wave mode for the stripping of adsorbed bovine insulin has proved to be much more sensitive, yielding signals 20 times larger than those obtained by applying a differential pulse scan. The precision obtained for the voltammetric method, at a concentration level as low as 0.77 mg L–1 of the protein, was found to be 1.45% (RSD., n = 8) by SWS and 2.20% (RSD., n = 8) by DPS. The pharmaceutical product Actrapid containing biosynthetic human insulin was analyzed by both methods. Received: 25 February 1999 / Revised: 6 April 1999 / Accepted: 12 April 1999  相似文献   

14.
Adsorption and reduction of rofecoxib were investigated by cyclic and square-wave voltammetry on a hanging mercury drop electrode in electrolytes of various pH values. The reduction process on hanging mercury drop electrodes gave rise to a single peak within the entire pH range (2.0-11.5). In alkaline solutions, rofecoxib gave a sensitive adsorptive reductive peak; approximately 10 times larger than those obtained by applying a square-wave scan without prior accumulation. Application of the method to the determination of rofecoxib in two pharmaceutical products (Vioxx 12.5 and 25 mg), without sample pretreatment, resulted in acceptable deviation from the stated concentrations.  相似文献   

15.
The adsorptive stripping voltammetric behavior of bovine insulin has been studied by both differential pulse and square-wave techniques, leading to analytical methodologies for its determination in aqueous samples and pharmaceutical preparations. The application of a square-wave mode for the stripping of adsorbed bovine insulin has proved to be much more sensitive, yielding signals 20 times larger than those obtained by applying a differential pulse scan. The precision obtained for the voltammetric method, at a concentration level as low as 0.77 mg L–1 of the protein, was found to be 1.45% (RSD., n = 8) by SWS and 2.20% (RSD., n = 8) by DPS. The pharmaceutical product Actrapid containing biosynthetic human insulin was analyzed by both methods. Received: 25 February 1999 / Revised: 6 April 1999 / Accepted: 12 April 1999  相似文献   

16.
Adsorptive stripping voltammetry of thiourea, α-naphthylthiourea and diphenyl-thiourea is discussed. In perchlorate solution, these compounds are adsorbed at the hanging mercury drop electrode at positive potentials (or at open circuit) and can be stripped in a cathodic scan. Detection limits are 2.5 ng l?1 for thiourea, 80 ng l?1 for α-naphthylthiourea and 50 ng l?4 for diphenylthiourea. The method is applicable in the determination of thiourea in cattle-feed and in the direct analysis of urine.  相似文献   

17.
Two chromatographic methods were developed for the determination of some anti-fungal drugs in the presence of either their degradation products or cortisone derivatives. The densitometric method determined mixtures of each of ketoconazole (KT), clotrimazole (CL), miconazole nitrate (MN) and econazole nitrate (EN) with the degradation products of each one. Mixtures of MN with hydrocortisone (HC) and of EN with triamcinolone acetonide (TA) were also successfully separated and determined by this technique. For KT and CL, a mixture of methanol:water:triethylamine (70:28:2 v/v) was used as a developing system and the spots were scanned at 243 nm and 220 nm for KT and CL, respectively. For MN and EN, a mixture of hexane:isopropyl alcohol:triethylamine (80:17:3 v/v) was used as a developing system and the spots were scanned at 225 nm for both drugs. The HPLC method determined mixtures of CL or EN with their degradation products which were separated and quantified on a Zorbax C8 column. Elution was carried out using methanol:phosphate buffer pH 2.5 (65:35 v/v) as a mobile phase at a flow rate of 1.5 ml/min and UV detection at 220 nm for CL. For EN, a mixture of methanol:water containing 0.06 ml triethylamine pH 10 (75:25 v/v) was used as a mobile phase at a flow rate of 1.5 ml/min and UV detection at 225 nm. The methods were also used to separate mixtures of CL with betamethasone dipropionate (BD) and EN with TA in a laboratory prepared mixture and in pharmaceutical preparations. The methods were sensitive, precise and applicable for determination of the drugs in pharmaceutical dosage forms.  相似文献   

18.
Palrecha MM  Mathur PK 《Talanta》1997,45(2):433-436
The electroanalytical chemistry of trace metals has progressed strongly with the development of cathodic stripping voltammetry (CSV) preceded by adsorption collection of organic metal complexes. A sensitive method for the determination of trace amount of chromium in gallium is described. Gallium is dissolved in sodium hydroxide containing hydrogen peroxide. The method is based on the catalytic activity of nitrate ions on the reduction of Cr(III)TTHA (triethylene tetramine-N,N,N',N',N',N'-hexaacetic acid) complex. The sensitivity of this method is further improved by adsorption preconcentration of Cr(III)TTHA complex at a hanging mercury drop electrode (HMDE). The Cr(III) formed at the electrode surface by the reduction of Cr(VI), which is present in the bulk solution, is immediately complexed by TTHA. The adsorbed complex is then reduced at a peak potential of - 1.26 V, and the peak height of Cr(III) reduction is measured. The determination limit was restricted by the amount of chromium present in the reagent blank solution. The method is suitable for the determination of chromium at level as low as 0.2 mug g(-1) (with about 50 mg of sample) and a relative standard deviation of 15%.  相似文献   

19.
抗坏血酸(AA)即维生素C (Vc)广泛存在于食品、动物体液、组织及药品中,它能激化羟化酶,促进组织中胶原的形成,同时参与体内许多物质的代谢过程.传统的AA分析检测方法很多,如吸光光度法、荧光光度法、化学发光法、滴定分析法和电化学方法[1-2].  相似文献   

20.
Imipenem shows a fast chemical conversion to a more stable imin form (identical to that of biochemical dehydropeptidase degradation) in aqueous solutions and stabilizing agents used avoid its electrochemical study and determination.The aim of this work is the proposal of urea as stabilizing agent which allows the electrochemical study of imipenem and the proposal of electrochemical methods for the determination of imipenem and its primary metabolite (M1) in human urine samples. Electrochemical studies were realized in phosphate buffer solutions over pH range 1.5-8.0 using differential-pulse polarography, DC-tast polarography, cyclic voltammetry and adsorptive stripping voltammetry. In acidic media, a non-reversible diffusion-controlled reduction involving a two steps mechanism which involves one electron and one proton in the first step and two electrons and two protons in the second step occurs and the mechanism for the reduction was suggested.A differential-pulse polarographic method for the determination of imipenem in the concentration range 3.2 × 10−6 to 2 × 10−5 M (0.95-3.4 mg/L) and its primary metabolite in the concentration range 1.4 × 10−6 to 10−4 M (0.43-26.1 mg/L) with detection limits of 9.6 × 10−7 M (0.28 μg/L imipenem) and 4.3 × 10−7 M (0.14 μg/L M1) was proposed. Also, a method based on controlled adsorptive pre-concentration of imipenem on the hanging mercury drop electrode followed by voltammetric measure, allows imipenem determination in the concentration range 1.8 × 10−8 to 1.2 × 10−6 M (5.42-347 μg/L) with a detection limit of 5.4 × 10−9 M (1.63 μg/L). The proposed methods have been used for the direct determination of the analytes in a pharmaceutical formulation and human urine.  相似文献   