首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 668 毫秒
1.
A novel method for the characterization of metal containing biological compounds has been developed which utilizes both nuclear activation [e.g.,12C(3He, α)11C] and atomic activations (X-ray emission) induced by 8 MeV3He bombardment. Detection limits for carbon (≈1 μg), oxygen (≈1μg), and metals (1 to 10 ng for elements between P and Zn) were obtained under routine experimental conditions. The metal stoichiometry of six different compounds (alkaline phosphatase, amylase, carbonic anhydrase, diamine oxidase, my oglobin, vitamin B12) were determined with typical relative precisions of ±25% for a 40 μg sample. A comparison of these ratios with carbon and metal measurements obtained by other methods showed a relative accuracy of 1 to 20%.  相似文献   

2.
A sensitive analytical method was established for the determination of Th and U in activated concrete samples. The method combines an anion-exchange separation step with an ICP-MS determination technique. In the ICP-MS measurement, a few μg mL–1 of Al and Ca, a few ng mL–1 of Mn, La, Ce, Nd and Pb and pg mL–1 amounts of Li, Zr, Nb and Ba coexisting in the anion-exchange fraction of Th and U did not interfere. No adverse interference effects were observed in real sample analyses. The obtained detection limits (3σ, n = 10) of Th and U were 2.3 and 1.8 pg mL–1, respectively. The analytical precisions for ca. 5 μg g–1 Th and ca. 1 μg g–1 U in real activated concrete samples were equally less than 7% RSD. The accuracies obtained by the analysis of GSJ rock standard samples were –18.1 to 0.4% for the Th determination and –14.0 to –5.7% for the U determination. The method uses the conventional absolute calibration curve. The internal standard calibration is unnecessary. Received: 14 March 1999 / Revised: 13 July 1999 / Accepted: 15 July 1999  相似文献   

3.
Guanidinoacetate methyltransferase deficiency is a recently discovered inborn defect of creatine biosynthesis which reduces serum creatinine concentrations to as low as 0.58 μg mL−1 (or 0.00058 μg mL−1 after 1,000-fold dilution). To measure ultra trace levels of creatinine in diluted samples, molecularly imprinted solid-phase extraction (MISPE) and molecularly imprinted polymer (MIP) sensor techniques have been found to be inadequate. A combination of these techniques (i.e. MISPE hyphenated with use of an MIP-sensor), reported in this paper, has been found to be highly suitable for direct assay of creatinine in highly diluted human blood serum without complicated pretreatment of the sample. The proposed technique has the potential to enhance the sensitivity of creatinine measurement from μg mL−1 to ng mL−1 in highly dilute aqueous samples in which the concentrations of interfering constituents are reduced to negligible levels. In this work the sensitivity to creatinine was found to be improved compared with that of the MIP-sensor method alone (limit of detection, LOD, 0.00149 μg mL−1). After preconcentration by MISPE and use of the sensor the detection limit for creatinine was as low as 0.00003 μg mL−1 (RSD = 0.94%, S/N = 3; 50-fold preconcentration factor) in aqueous samples.  相似文献   

4.
 A method for direct analysis of tea and coffee samples by using electrothermal atomic absorption spectrometry is described. Coffee and tea from different sources were analyzed without digestion step. For slurry analyses the samples were ground, sieved at 105 μm and then suspended in 0.2% v/v HNO3 and 10% v/v Triton X-100 medium. For liquid phase aluminium determination the samples were prepared in the same way and only the liquid is introduced directly into the graphite furnace. Calibration was performed by aqueous standards for both cases and the determinations were carried out in the linear range between 50 and 250 μg L−1. The characteristic mass of aluminium and the detection limit were 45 pg and 2 μg L−1, respectively. Using a typical 0.1% m/v coffee slurry sample, the relative standard deviation of measurements (n=15) for repeatability was about 8.2%. Received December 27, 1998. Revision March 18, 1999.  相似文献   

5.
Summary An ion-chromatographic procedure is described for the determination of selenium (VI) at μg L−1 level in the presence of anions and heavy metal ions. Maximum permissible concentrations and effects from each interfering substance were investigated for the Se concentration range 12.5–1,000 μg L−1. The method, optimized for the detection of SeO 4 2− , gives results suitable for speciation analysis. Total selenium can be determined after complete conversion to selenate ion by oxidation with KMnO4. The detection limit of selenium is 4.8 μg L−1 (0.96 ng for 200 μL sample). Paper presented at the 41st Pittsburgh Conference, New York, March 5–9, 1990.  相似文献   

6.
A technical modification of the traditional method of decomposition of carbonates in phosphoric acid was proposed for the determination of δ13C and δ18O in organogenic carbonate samples weighing 10–30 μg with an accuracy of 0.05%. The extraction of CO2 was carried out under a vacuum at 95°C in 105% phosphoric acid. The isotopic composition of CO2 was measured by CG-IRMS. The used feed-motion of samples to the reactor provides a consecutive delivery of the samples from the sample holders to the acid. This sample feeding method prevents the contamination of the acid with impurities from the surface of the sample, obviates the necessity of removing the sample holders from the acid, and allows the use of the same acid for performing a very large numbers of analyses. The accuracy and reproducibility of the δ13C and δ18O values was estimated by measuring international standards and comparing with the δ13C and δ18O values for organogenic carbonate samples obtained by the proposed method of analysis at a microgram level and the traditional method at a milligram level. The proposed technology was successfully used to study the isotopic composition of oxygen and carbon in the plankton and benthos foraminifers in order to reconstruct the Okhotsk Sea palaeotemperatures.  相似文献   

7.
A minicolumn packed with poly(aminophosphonic acid) chelating resin incorporated in an on-line preconcentration system for flame atomic-absorption spectrometry was used to determine ultratrace amounts of lead in mussel samples at μg L–1 level. The preconcentrated lead was eluted with hydrochloric acid and injected directly into the nebulizer for atomization in an air-acetylene flame for measurement. The performance characteristics of the determination of lead were: preconcentration factor 26.8 for 1 min preconcentration time, detection limit (3σ) in the sample digest was 0.25 μg g–1 (dry weight) for a sample volume of 3.5 mL and 0.2 g sample (preconcentration time 1 min), precision (RSD) 2.3% for 25 μg L–1 and 2.0% for 50 μg L–1. The sampling frequency was 45 h–1. The method was highly tolerant of interferences, and the results obtained for the determination of lead in a reference material testify to the applicability of the proposed procedure to the determination of lead at ultratrace level in biological materials such as mussel samples. Received: 1 November 2000 / Revised: 8 January 2001/ Accepted: 11 January 2001  相似文献   

8.
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L−1 HCl and 1% m/v K3[Fe(CN)6] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 μg L−1 and 1 μg L−1, respectively. The relative standard deviation varies between 2–6% (within-run) and 4–11% (between-run) at 3–30 μg L−1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2–25.8 μg L−1 Pb.  相似文献   

9.
A method is described for the determination of carbon in iron, chromium, nickel, and molybdenum, using the12C (γ, n)11C reaction. The samples are irradiated with the bremstrahlung from a 35 MeV electron beam impinging a platinum target. Two apparatuses for the separation of carbon are described. The11C* activity of the sample is compared with the activities of two graphite standards, counting the positron annihilation gamma rays. The limit of detection is 0.02 μg/g of carbon in high-purity iron.   相似文献   

10.
Summary A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and the results have been compared with those obtained by derivatizing the analyte in pre-column mode. The method described has been applied to the determination of amphetamine in plasma and urine. Good linearity and reproducibility were obtained in the 0.1–10.0 μg mL−1 concentration range, and limits of detection were 25 ng mL−1 and 10 ng mL−1 with UV and fluorescence detection, respectively. The procedure described is very simple and rapid, because no off-line manipulation of the sample is required; the total analysis time is approximately 8 min.  相似文献   

11.
A method for the determination of cyanide in blood plasma by differential pulse polarography (DPP) is described without a drastic acidification of the sample. Cyanide was determined as tetracyanonickelate(II)-anion complex after a microwave-acid assisted cleanup and a selective complex extraction in a polyethylene methylene blue (PE-MB) impregnated column. The cyano complex was eluted from the column with water/acetonitrile and determined by pulse-polarography at –380 mV (Ag/AgCl). The linear range of calibration was obtained from 1.2 to 9.6 μg of cyanide with r = 0.99 and RSD = 9% of 1.2 μg of cyanide. A detection limit of 40 μg L–1 was calculated and the recoveries of cyanide from spiked samples were about 80%. This method was compared with the classical pyridine-pyrazolone method. Received: 3 September 1997 / Revised: 21 January 1998 / Accepted: 24 January 1998  相似文献   

12.
Hollow-fiber liquid-phase microextraction (HF-LPME), a relatively new sample preparation technique, has attracted much interest in the field of environmental analysis. In the current study, a novel method based on hollow-fiber liquid-phase microextraction with in situ derivatization and gas chromatography–mass spectrometry for the measurement of triclosan in aqueous samples is described. Hollow-fiber liquid-phase microextraction conditions such as the type of extraction solvent, the stirring rate, the volume of derivatizing reagent, and the extraction time were investigated. When the conditions had been optimized, the linear range was found to be 0.05–100 μg l−1 for triclosan, and the limit of detection to be 0.02 μg l−1. Tap water and surface water samples collected from our laboratory and Wohushan reservoir, respectively, were successfully analyzed using the proposed method. The recoveries from the spiked water samples were 83.6 and 114.1%, respectively; and the relative standard deviation (RSD) at the 1.0 μg l−1 level was 6.9%.  相似文献   

13.
A highly sensitive and very simple spectrophotometric flow-injection analysis (FIA) method for the determination of iron(III) at low concentration levels is presented. The method is based on the measurement of absorbance intensity of the red complex at 410 nm formed by iron(III) and diphenylamine-4-sulfonic acid sodium salt (DPA-4-SA). It is a simple, highly sensitive, fast, and low cost alternative method using the color developing reagent DPA-4-SA in acetate buffer at pH 5.50 and the flow-rate of 1 mL min−1 with the sample throughput of 60 h−1. The method provided a linear determination range between 5 μg L−1 and 200 μg L−1 with the detection limit (3S) of 1 μg L−1 of iron(III) using the injection volume of 20 μL. FIA variables influencing the system performance were optimized. The amount of iron(III) and total iron in river and seawater samples was successfully determined. Repeatability of the measurements was satisfactory at the relative standard deviation of 3.5 % for 5 determinations of 10 μg L−1 iron(III). The accuracy of the method was evaluated using the standard addition method and checked by the analysis of the certified material Std Zn/Al/Cu 43 XZ3F.  相似文献   

14.
Red clover (Trifolium pratense L.) is an important forage plant that contains the isoflavones daidzein, genistein, formononetin, and biochanin A. These compounds have been studied lately due to their human health benefits. The aim of this study was to develop and validate an HPLC method with simplified sample preparation to quantify daidzein, genistein, formononetin and biochanin A simultaneously in red clover leaves. The validation showed that the method is specific, accurate, precise and robust, not to mention that the sample preparation is easier and faster than those described earlier. The response was linear over a range of 0.01–0.2 μg mL−1 for daidzein, 0.05–0.5 μg mL−1 for genistein, 4–40 μg mL−1 for formononetin and 2–20 μg mL−1 for biochanin A. The range of recoveries was 85.6–101.0%. The RSD for intra- and inter-day precision were <2.54 and <7.22%, respectively. Five populations of red clover, from the National Plant Germplasm System-USDA were analyzed and the content of daidzein, genistein, formononetin and biochanin A ranged from 7.87–91.31, 51.60–131.30, 6568.33–23461.82, to 2499.55–10337.33 μg g−1 of dried material, respectively.  相似文献   

15.
An analytical method is described for the determination of erbium in rock samples using γ-rays from a24Na radiation source. A detection limit of 1 μg erbium in 10 g samples can be achieved using a 200 Ci24Na source. The time required for a single analysis is about 5 minutes.  相似文献   

16.
A continuous flow-through solid phase spectrophotometric system was developed for the determination of ascorbic acid based on the measurement of its intrinsic absorbance in the UV region when retained on a 1 mm Sephadex QAE A-25 anion exchanger gel layer which is placed into an appropriate quartz flow-through cell, the absorbance exhibited by this solid phase being monitored at 267 nm. A monochannel manifold was used, the sample (300, 600 or 1000 μL) being injected into the carrier solution (acetate buffer). This solution also elutes the analyte after developing the analytical signal, and regenerates the resin layer which, therefore, remains ready for the next sample. The linear dynamic range and other analytical parameters vary according to the sample volume injected. Three calibration lines were established for 300, 600 and 1000 μL sample volume, which ranged from 1.0 to 20.0, 0.5 to 10.0 and 0.2 to 6.0 μg mL–1, respectively. The detection limits were 0.04 (300 μL), 0.03 (600 μL) and 0.02 μg mL–1 (1000 μL), the sampling rates 28, 24 and 21 h–1, and the RSDs (n = 10) 0.87%, 1.08% and 0.90%, respectively. The amount of ascorbic acid in various samples (pharmaceuticals, sweets and urine) were successfully determined with this method. Received: 28 April 1998 / Revised: 3 June 1998 / Accepted: 30 June 1998  相似文献   

17.
A continuous flow-through solid phase spectrophotometric system was developed for the determination of ascorbic acid based on the measurement of its intrinsic absorbance in the UV region when retained on a 1 mm Sephadex QAE A-25 anion exchanger gel layer which is placed into an appropriate quartz flow-through cell, the absorbance exhibited by this solid phase being monitored at 267 nm. A monochannel manifold was used, the sample (300, 600 or 1000 μL) being injected into the carrier solution (acetate buffer). This solution also elutes the analyte after developing the analytical signal, and regenerates the resin layer which, therefore, remains ready for the next sample. The linear dynamic range and other analytical parameters vary according to the sample volume injected. Three calibration lines were established for 300, 600 and 1000 μL sample volume, which ranged from 1.0 to 20.0, 0.5 to 10.0 and 0.2 to 6.0 μg mL–1, respectively. The detection limits were 0.04 (300 μL), 0.03 (600 μL) and 0.02 μg mL–1 (1000 μL), the sampling rates 28, 24 and 21 h–1, and the RSDs (n = 10) 0.87%, 1.08% and 0.90%, respectively. The amount of ascorbic acid in various samples (pharmaceuticals, sweets and urine) were successfully determined with this method. Received: 28 April 1998 / Revised: 3 June 1998 / Accepted: 30 June 1998  相似文献   

18.
Summary This paper describes an HPLC method for the determination of meropenem in human plasma. The method uses solid phase extraction (SPE) of the samples and has good sensitivity, precision and accuracy. The limit of quantification in plasma samples is 0.02 μg mL−1. Calibration curves were linear over a large dynamic range, namely within 0.02–50 μg mL−1. The method was applied to the determination of meropenem levels in patients receiving meropenem, as a single dose or at steady state.  相似文献   

19.
Simple, sensitive, and reproducible off-line solid-phase microextraction and liquid chromatography (SPME/LC) methods are described for the determination of seven anticonvulsants and tricyclic antidepressants in human plasma. Factorial design and simplex methodology were applied in the optimization of the SPME procedure for tricyclic antidepressants analyses. Important factors in the SPME efficiency are discussed, such as the fiber coatings (both lab-made and commercial), extraction time, pH, ionic strength, influence of plasma proteins, and desorption conditions. The development of the lab-made fiber coatings, namely, octadecylsilane, aminosilane, and polyurethane, are further described and applied to anticonvulsants analyses. The investigated plasmatic range for the evaluated anticonvulsants, using CW-TPR fiber, were the following: phenylethylmalonamide (3.00–40.0 μg mL−1), phenobarbital (5.00–40.0 μg mL−1), primidone (3.00–40.0 μg mL−1), carbamazepine and carbamazepine-epoxide (2.00–24.0 μg mL−1), phenytoin (2.00–40.0 μg mL−1), and lamotrigine (0.50–12.0 μg mL−1). The antidepressants’ linear plasmatic concentration ranged from 75.0 to 500 ng mL−1 for imipramine, amitriptyline, and desipramine, and from 50.0 to 500 ng mL−1 for nortriptyline, being in all cases, the limit of quantification represented by the lowest value. The precision (interassays) for all investigated drugs in plasma sample spiked with different concentrations of each analyte and submitted to the described procedures were lower than 15%. The off-line SPME/LC methodologies developed allow anticonvulsants and antidepressants analyses from therapeutic to toxic levels for therapeutic drug monitoring.  相似文献   

20.
A method is described for the use of212Pb to measure overall recovery in lead analyses. Other modifications of published procedures are also outlined. Most difficulties occur with samples containing small amounts (<10 μg) of Pb. In addition to low recovery factors, spectra are often obscured by the presence of dithizone oxidation product: a procedure for dealing with this is given.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号