首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
In this contribution, linear poly(ethylene imine) (PEI) polymers, which are of importance in gene delivery, are investigated in detail by using electrospray ionization‐quadrupole‐time of flight (ESI‐Q‐TOF) and matrix‐assisted laser desorption/ionization‐time of flight (MALDI‐TOF) mass spectrometry (MS). The analyzed PEIs with different end groups were synthesized using the polymerization of substituted 2‐oxazoline via a living cationic ring‐opening polymerization (CROP) and a subsequent hydrolysis under acidic conditions. The main goal of this study was to identify linear PEI polymers in a detailed way to gain information about their fragmentation pathways. For this purpose, a detailed characterization of three different linear PEIs was performed by using ESI‐Q‐TOF and MALDI‐TOF MS in combination with collision‐induced dissociation (CID) experiments. In ESI‐MS as well as MALDI‐MS analysis, the obtained spectra of PEIs resulted in fitting mass distributions for the investigated PEIs. In the tandem MS analysis, a 1,2‐hydride shift with a charge‐remote rearrangement via a four‐membered cyclic transition state, as well as charge‐induced fragmentation reactions, was proposed as the main fragmentation mechanisms according to the obtained fragmentation products from the protonated parent peaks. In addition, heterolytic and homolytic cleavages were proposed as alternative fragmentation pathways. Moreover, a 1,4‐hydrogen elimination was proposed to explain different fragmentation products obtained from the sodiated parent peaks. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time‐of‐flight MS coupled with LC (LC‐IT‐TOF‐MS) has successfully integrated ease of operation, compatibility with LC flow rates and data‐dependent MSn with high mass accuracy and mass resolving power. The MSn and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC‐IT‐TOF‐MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT‐TOF instrument. Then, a general workflow for metabolite profiling using LC‐IT‐TOF‐MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC‐IT‐TOF‐MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
We present the MALDI‐TOF/TOF‐MS analyses of various hapten–bovine serum albumin (BSA) neoglycoconjugates obtained by squaric acid chemistry coupling of the spacer‐equipped, terminal monosaccharide of the O‐specific polysaccharide of Vibrio cholerae O1, serotype Ogawa, to BSA. These analyses allowed not only to calculate the molecular masses of the hapten–BSA neoglycoconjugates with different hapten–BSA ratios (4.3, 6.6 and 13.2) but, more importantly, also to localize the covalent linkages (conjugation sites) between the hapten and the carrier protein. Determination of the site of glycation was based on comparison of the MALDI‐TOF/TOF‐MS analysis of the peptides resulting from the digestion of BSA with similar data resulting from the digestion of BSA glycoconjugates, followed by sequencing by MALDI‐TOF/TOF‐MS/MS of the glycated peptides. The product‐ion scans of the protonated molecules were carried out with a MALDI‐TOF/TOF‐MS/MS tandem mass spectrometer equipped with a high‐collision energy cell. The high‐energy collision‐induced dissociation (CID) spectra afforded product ions formed by fragmentation of the carbohydrate hapten and amino acid sequences conjugated with fragments of the carbohydrate hapten. We were able to identify three conjugation sites on lysine residues (Lys235, Lys437 and Lys455). It was shown that these lysine residues are very reactive and bind lysine specific reagents. We presume that these Lys residues belong to those that are considered to be sterically more accessible on the surface of the tridimensional structure. The identification of the y‐series product ions was very useful for the sequencing of various peptides. The series of a‐ and b‐product ions confirmed the sequence of the conjugated peptides. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Liquid chromatography/mass spectrometry (LC/MS) was used as a method for analyzing the metabolites of a model short interfering RNA (siRNA) duplex. The model siRNA duplex incorporated oligonucleotide stabilizing and protecting chemistries as these have been shown to increase the half-life of oligonucleotides. Two complementary 23 nucleotide single strands were joined to form the duplex. The intact duplex was analyzed using ion-pair reversed-phase chromatography coupled to electrospray ionization mass spectrometry (ESI-MS). The method used a hexafluoroisopropanol/triethylamine ion-pairing buffer with a methanol gradient to separate single-stranded oligonucleotide components from the duplex. This buffer system with ESI also preserved the duplex in the gas phase for analysis by a triple quadrupole mass spectrometer. Using this methodology, in vitro and in vivo metabolites from urine and rabbit ocular vitreous humor were determined and a pattern of duplex siRNA degradation was established. The masses of the metabolites were determined by ESI-MS and used with the known sequence of the siRNA duplex to identify the metabolites. Over the time course of the metabolism experiments it was shown that the breakdown products of the siRNA are consistent with the nuclease protection given by chemical modifications and that the duplex structure adds additional stability compared to the single strands alone. This study demonstrates that the ability of LC/MS to analyze duplex oligonucleotides has unique benefits for the study of siRNA metabolism.  相似文献   

5.
MS/MS experiment and accurate mass measurement are powerful tools in metabolite identification. However, sometimes these data do not provide enough information to assign an unambiguous structure to a metabolite. In combination with MS techniques, hydrogen/deuterium (H/D) exchange can provide additional information for structural elucidation by determination of the number of exchangeable hydrogen atoms in a structure. In this study, the principal phase I metabolites of iso‐phenylcyclopentylamine in rat bile were identified by high‐performance liquid chromatography with electrospray ionization quadrupole time‐of‐flight mass spectrometry (ESI‐Q‐TOF‐MS). Since N‐oxidation may occur because of the existence of the primary amino group in the structure, it was difficult to differentiate the hydroxylated metabolites from N‐oxides by ESI‐Q‐TOF‐MS alone. Therefore, online H/D exchange technique was applied to solve this problem. Finally, 25 phase I metabolites were detected and structurally described, in which 11 were confirmed to be N‐oxides. This study demonstrated the effectiveness of high‐resolution mass spectrometry in combination with an online H/D exchange technique in rapid identification of drug metabolites, especially in discriminating hydroxylated metabolites from N‐oxides. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Analyzing brain microdialysate samples by mass spectrometry is challenging due to the high salt content of the artificial cerebral spinal fluid (aCSF), low analyte concentrations and small sample volumes collected. A drug and its major metabolites can be examined in brain microdialysates by targeted approaches such as selected reaction monitoring (SRM) which provides selectivity and high sensitivity. However, this approach is not well suited for metabolite profiling in the brain which aims to determine biotransformation pathways. Identifying minor metabolites, or metabolites that arise from brain metabolism, remains a challenge and, for a drug in early discovery, identification of metabolites present in the brain can provide useful information for understanding the pharmacological activity and potential toxicological liabilities of the drug. A method is described here for rapid metabolite profiling in brain microdialysates that involves sample clean‐up using C18 ZipTips to remove salts followed by direct infusion nanoelectrospray with an LTQ/Orbitrap mass spectrometer using real‐time internal recalibration. Full scan mass spectra acquired at high resolving power (100 K at m/z 400) were examined manually and with mass defect filtering. Metabolite identification was aided by sub‐parts‐per‐million mass accuracy and structural characterization was accomplished by tandem mass spectrometry (MS/MS) experiments in the Orbitrap or LTQ depending on the abundance of the metabolite. Using this approach, brain microdialysate samples from rats dosed with one of four CNS drugs (imipramine, reboxetine, citalopram or trazodone) were examined for metabolites. For each drug investigated, metabolites, some of which not previously reported in rat brain, were identified and characterized. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Isopropyl 3‐(3,4‐dihydroxyphenyl)‐2‐hydroxypropanoate (IDHP) is an investigational new drug having the capacity for treating ailments in the cardiovascular and cerebrovascular system. In this work, a rapid and sensitive method using high‐performance liquid chromatography coupled with electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (HPLC‐ESI‐Q‐TOF‐MS) was developed to reveal the metabolic profile of IDHP in rats after oral administration. The method involved pretreatment of the samples by formic acid–methanol solution (v/v, 5:95), chromatographic separation by an Agilent Eclipse XDB‐C18 column (150 × 4.6 mm i.dx., 5 μm) and online identification of the metabolites by Q‐TOF‐MS equipped with electrospray ionizer. A total of 16 metabolites from IDHP, including four phase I metabolites and 12 phase II metabolites, were detected and tentatively identified from rat plasma, urine and feces. Among these metabolites, Danshensu (DSS), a hydrolysis product of IDHP, could be further transformed to 11 metabolites. These results indicated that DSS was the main metabolite of IDHP in rats and the major metabolic pathways of IDHP in vivo were hydrolysis, O‐methylation, sulfation, glucuronidation and reduction. The results also demonstrated that renal route was the main pathway of IDHP clearance in rat. The present study provided valuable information for better understanding the efficacy and safety of IDHP. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
9.
Modern glycan analysis is primarily based on mass spectrometry, where instruments based on electrospray or matrix-assisted laser desorption ionization are currently the most frequently used. In the present study, electrospray ionization (ESI) coupled with a high-resolution Fourier transform mass spectrometer (LTQ Orbitrap) and matrix-assisted laser desorption/ionization (MALDI) coupled with a time-of-flight (TOF/TOF) detector were used to analyze two N-glycan standards with intact free reducing ends (disialo biantennary and asialo triantennary) and representative PA-labeled human serum N-glycan structures isolated by hydrophilic interaction anion-exchange chromatography (HIAX), confirmed by 1H NMR analysis and consequently compared with the ProteinScape Glycome database. Different combinations of ion sources with fragmentation devices results in various fragmentation patterns and adducts. Also, the effect of sample derivatization on the acquired signals is discussed. Compared to the MALDI technique, free glycans did not lose labile sialic acids easily in the ESI source. On the other hand, fluorescent PA-labeling leads to improved core fragmentation and signal intensities; linkage-specific ethyl esterification leads to reduced adduct and fragment formation and enhanced stability of sialic acids in the MALDI ion source. Thereby, both methods have their advantages and disadvantages in terms of detection, fragmentation and robustness.  相似文献   

10.
The Orbitrap: a new mass spectrometer   总被引:15,自引:0,他引:15  
  相似文献   

11.
A transmission geometry optical configuration allows for smaller laser spot size to facilitate high‐resolution matrix‐assisted laser/desorption ionization (MALDI) mass spectrometry. This increase in spatial resolution (ie, smaller laser spot size) is often associated with a decrease in analyte signal. MALDI‐2 is a post‐ionization technique, which irradiates ions and neutrals generated in the initial MALDI plume with a second orthogonal laser pulse, and has been shown to improve sensitivity. Herein, we have modified a commercial Orbitrap mass spectrometer to incorporate a transmission geometry MALDI source with MALDI‐2 capabilities to improve sensitivity at higher spatial resolutions.  相似文献   

12.
Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measurements by high-resolution TOFMS are equally important. This paper describes the role that high mass measurement accuracy can play in DNA composition assignment and discusses the influence of several parameters on mass measurement accuracy in both MALDI and ESI mass spectra. Five oligonucleotides (5-13mers) were used to test the resolving power and mass measurement accuracy obtained with MALDI and ESI instruments with reflectron TOF mass analyzers. The results from the experimental studies and additional theoretical calculations provide a basis to predict the practical utility of high-resolution TOFMS for the analysis of larger oligonucleotides.  相似文献   

13.
A new tandem time‐of‐flight mass spectrometer with an electrospray ionization ion source ‘ESI‐TOF/quadTOF’ was designed and constructed to achieve the desired aim of structural elucidation via high‐energy collision‐induced dissociation (CID), and the simultaneous detection of all fragment ions. The instrument consists of an orthogonal acceleration‐type ESI ion source, a linear TOF mass spectrometer, a collision cell, a quadratic‐field ion mirror and a microchannel plate detector. High‐energy CID spectra of doubly protonated angiotensin II and bradykinin were obtained. Several fragment ions such as a‐, d‐, v‐ and w‐type ions, characteristic of high‐energy CID, were clearly observed in these spectra. These high‐energy CID fragment ions enabled confirmation of the complete sequence, including leucine–isoleucine determinations. It was demonstrated that high‐energy CID of multiply protonated peptides could be achieved in the ESI‐TOF/quadTOF. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
High‐resolution matrix‐assisted laser desorption/ionization (MALDI) time‐of‐flight mass spectrometry (TOF MS) was used for the analysis of the low‐molecular‐weight products from the photo‐oxidation of poly(3‐hexylthiophene) (P3HT) in solution and thin film. Eight new peak series were observed in the low‐mass range of the mass spectra of the products degraded in solution, and the formulas of the eight components were determined from the accurate mass. From SEC/MALDI‐TOF MS, two components were identified as the degraded products, and the other six components were derived from the fragmentation of the degraded products during the MALDI process. A mechanism for the formation of these components was proposed on the basis of the results of MALDI‐TOF MS. For the thin film degradation, a part of products in the solution degradation were observed, which supports that the oxidation of P3HT in solution and thin film proceeded in the same mechanism. This study shows that high‐resolution MALDI‐TOF MS is effective for the analysis of the low‐molecular‐weight products from P3HT photo‐oxidation and expected to be feasible for the degradation analyses of other polymers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Oligosaccharides represent complex class of analytes for mass spectrometric analysis due to the high variety of structural isomers concerning glycosidic linkages and possible branching. A systematic study of the negative ion mode matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry of various neutral oligosaccharides under selection of an appropriate matrix, like 2,5‐dihydroxyacetophenone (2,5‐DHAP) is reported here, without commonly used anion dopant strategies. Nevertheless, we were able to generate relevant in‐source decay (ISD) cross‐ring fragment ions, typically obtained in the negative ion mode. Data observed indicate that the intrinsic property of the terminal non‐reduced aldose is crucial for this behavior. A systematic study of the post source decay (PSD) of molecular, pseudomolecular and ISD cross‐ring cleavage precursor ions is reported here. A direct comparison of the positive and negative ion mode MALDI MS1 and PSD behavior of neutral oligosaccharides could also be performed under the use of the same matrix preparation, because 2,5‐DHAP is fully compatible with positive ion mode acquisition. We found that PSD spectra of deprotonated neutral oligosaccharides obtained in the negative ion mode are richer, because they contained both glycosidic and cross‐ring fragment ions. However, we also found that cross‐ring fragment ions are readily produced in the positive ion mode when potassiated precursor ions were selected. In addition, we show evidence that non‐anionic dopants and specific instrumental parameters can also significantly influence the ISD fragmentation. Taken together, our results should increase our understanding of oligosaccharide behavior in the negative ion mode as well as increase our knowledge regarding many aspects of in‐source MALDI chemistry. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
On-line liquid chromatography/electrospray ionization high-resolution mass spectrometry (LC/ESI-HRMS) using an LTQ-Orbitrap mass spectrometer was employed to investigate the metabolite profiles of a model siRNA duplex designated HBV263. The HBV263 duplex was incubated in rat and human serum and liver microsomes in vitro. The siRNA drug and its metabolites were then extracted using a liquid-liquid extraction followed by solid-phase extraction (LLE-SPE), and analyzed by LC/ESI-MS. High-resolution accurate mass data enabled differentiation between two possible metabolite sequences with a monoisotopic molecular mass difference of less than 1 Da. ProMass deconvolution software was used to provide semi-automated data processing. In vitro serum and liver microsome incubation samples afforded different metabolite patterns: the antisense strand of the duplex was degraded preferentially in rat and human serum, while the sense strand of the duplex was less stable in rat and human liver microsomes.  相似文献   

17.
Mass spectrometry (MS) is used to quantify the relative distribution of glycans attached to particular protein glycosylation sites (micro‐heterogeneity) and evaluate the molar site occupancy (macro‐heterogeneity) in glycoproteomics. However, the accuracy of MS for such quantitative measurements remains to be clarified. As a key step towards this goal, a panel of related tryptic peptides with and without complex, biantennary, disialylated N‐glycans was chemically synthesised by solid‐phase peptide synthesis. Peptides mimicking those resulting from enzymatic deglycosylation using PNGase F/A and endo D/F/H were synthetically produced, carrying aspartic acid and N‐acetylglucosamine‐linked asparagine residues, respectively, at the glycosylation site. The MS ionisation/detection strengths of these pure, well‐defined and quantified compounds were investigated using various MS ionisation techniques and mass analysers (ESI‐IT, ESI‐Q‐TOF, MALDI‐TOF, ESI/MALDI‐FT‐ICR‐MS). Depending on the ion source/mass analyser, glycopeptides carrying complex‐type N‐glycans exhibited clearly lower signal strengths (10–50% of an unglycosylated peptide) when equimolar amounts were analysed. Less ionisation/detection bias was observed when the glycopeptides were analysed by nano‐ESI and medium‐pressure MALDI. The position of the glycosylation site within the tryptic peptides also influenced the signal response, in particular if detected as singly or doubly charged signals. This is the first study to systematically and quantitatively address and determine MS glycopeptide ionisation/detection strengths to evaluate glycoprotein micro‐heterogeneity and macro‐heterogeneity by label‐free approaches. These data form a much needed knowledge base for accurate quantitative glycoproteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A broadly applicable, robust, and rapid method for complete sequence confirmation of highly modified oligonucleotides containing a mixture of 2′‐deoxy, 2′‐fluoro, 2′‐o‐methyl, abasic and ribonucleotides is presented. The passenger (sense) and guide (antisense) strands from synthetic short interfering RNA duplexes (siRNA) were digested individually using both 5′‐ and 3′‐exonucleases and the resulting ladders were analyzed using matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Conditions for enzymatic digestion and MALDI‐TOF mass analysis were investigated and optimized, and the digestion pattern and sequence coverage of each strand was discussed. Complete sequence confirmation for the antisense strands of four synthetic RNA duplexes was obtained, whereas a three‐base sequence gap in the 5′‐end was observed for all four sense strands. A general strategy is proposed for routine sequence confirmation of highly modified oligonucleotides, and the potential for complete automation of the method is also discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
Chemical cross‐linking combined with a subsequent enzymatic digestion and mass spectrometric analysis of the created cross‐linked products presents an alternative approach to assess low‐resolution protein structures. By covalently connecting pairs of functional groups within a protein or a protein complex a set of structurally defined interactions is built up. We synthesized the heterobifunctional amine‐reactive photo‐cross‐linker N‐succinimidyl p‐benzoyldihydrocinnamate as a non‐deuterated (SBC) and doubly deuterated derivative (SBDC). Applying a 1:1 mixture of SBC and SBDC for cross‐linking experiments aided the identification of cross‐linked amino acids in the mass spectra based on the characteristic isotope patterns of fragment ions. The cross‐linker was applied to the calcium‐binding protein calmodulin with a subsequent analysis of cross‐linked products by nano‐high‐performance liquid chromatography matrix‐assisted laser desorption/ionization tandem time‐of‐flight mass spectrometry (nano‐HPLC/MALDI‐TOF/TOF‐MS) and nano‐HPLC/nano‐electrospray ionization (ESI)‐LTQ‐Orbitrap‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Matrix‐assisted laser desorption/ionization in‐source decay (MALDI‐ISD) has been used for characterization of a phosphorylated peptides and proteins because labile phosphate group is not lost during the MALDI‐ISD process. The conventional MALDI‐ISD is initiated by the hydrogen transfer from reducing matrix molecules to peptide backbone, leading to c′‐ and z′‐series ions. In contrast, when an oxidizing chemical 5‐nitrosalicylic acid (5‐NSA) is served as the MALDI‐ISD matrix, a‐ and x‐series ions are specifically generated by hydrogen abstraction from peptide backbone to matrix molecule. The 5‐NSA provides useful complementary information to the conventional MALDI‐ISD for the analysis of amino acid sequencing and site localization of phosphorylation in peptides. The MALDI‐ISD with reducing and oxidizing matrix could be a useful method for the de novo peptide sequencing. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号