首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analytical model and equations for describing the field of a planar magnetic lens with two concentric nonmagnetic gaps are developed. It is demonstrated that the “half-width” of the magnetic field of the lens can be controlled by varying independently the currents in the excitation coils of the two gaps. This makes it possible to control the focal length and the spherical aberration of the lens. It is shown that when oppositely directed currents are used in the excitation coils, a planar magnetic lens that does not rotate the image can be obtained. Zh. Tekh. Fiz. 69, 133–134 (August 1999)  相似文献   

2.
分析了由六极磁场构成了原子束磁透镜的原理及像差。在比较了热原子束和单色冷原子束的会聚效果后得出结论:影响它成像的主要因素是色差。应用激光冷却技术能使这一影响减小,从而使磁透镜在原子光学领域得到更广泛的应用。  相似文献   

3.
李楠  黄凯凯  陆璇辉 《物理学报》2013,62(13):133201-133201
本文报道了一种基于激光抽运射频共振的铯原子磁力仪. 通过圆偏振光将铯原子抽运到暗态, 实现偏极化. 外磁场存在时, 原子磁矩将以拉莫尔频率绕外磁场进动. 在共振射频磁场的作用下, 原子被去极化而重新吸收光子. 通过探测出射光光谱可以测得拉莫尔频率进而得到外磁场的信息. 本文通过运用自制的894 nm 外腔半导体激光器, 建立了激光稳频装置和低噪声磁场测量环境, 实现了一种基于铯原子激光抽运射频共振的磁力仪. 通过磁力仪参数优化以及闭环测量, 磁力仪测量的外磁场达到了19 fT/Hz1/2的极限灵敏度和1.8 pT/Hz1/2的本征灵敏度, 空间分辨率小于2 cm. 关键词: 光抽运 塞曼效应 光探测磁共振 磁力仪  相似文献   

4.
Electrons from a source in a solenoidal magnetic field emerge from that field with a characteristic angular momentum. This behavior can be used to produce a flat ribbon-like electron beam with zero thickness (to first order). We show that this can be done using a quadrupole triplet and provide analytical expressions for the focal length of each lens. Solutions can be found over a wide range of practical values of the parameters.  相似文献   

5.
高能质子照相系统由四极磁透镜和准直器组成,实际透镜的边缘场将影响成像系统的性能.本文将含边缘场的磁场梯度用贝尔函数近似,提出了一种含边缘场的成像系统优化方法.通过Geant 4程序模拟了能量为1.6 GeV的质子成像系统,并通过优化方法给出了考虑边缘场的优化后的系统参数.研究了考虑边缘场时的成像系统参数对准直器孔径的影响.通过对比理想成像系统和优化前后的成像系统在使用准直器时的客体通量分布,研究了边缘场对质子通过客体的通量影响.结果表明,优化后的成像系统可以减小质子通过客体后的通量误差,并且积分差值在10^–2量级时,准直器的孔径参数变化亦在10^–2量级.  相似文献   

6.
黄兰友 《物理学报》1977,26(5):250-258
用假设弱透镜焦距表达式是一个幂级数中的第一项的方法,可以导出相当准确且便于实用的电磁电子透镜物镜焦距公式。这个外推了的弱透镜近似公式能在即使相当强的激励下仍保持准确。这个方法也能用于其他一些光学参量。对于不能用此方法的光学参量,本文也导出了实用的经验公式。式中的常数是用前人发表的数据确定的。公式的准确度足够满足电子光学设计要求。  相似文献   

7.
Detection of NMR signals with a radio-frequency atomic magnetometer   总被引:1,自引:0,他引:1  
We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.  相似文献   

8.
本文基于卡塞格林系统设计了红外制冷型长焦分档变倍光学系统,计算、推导了光学初始参数及组元的光焦度分配。采用了二次成像结构形式,主物镜组采用R-C光学结构用于缩短筒长,使用投影镜组解决冷屏匹配问题,利用调焦镜实现调焦,通过切换投影镜组后组实现变倍,然后对光学系统像差进行了优化设计,分别给出了长焦系统和短焦系统不同视场的成像质量优化结果,0.8视场内光学传递函数在空间频率17 lp/mm时均大于0.4。最后对主要结构进行了相应的精度分析,结果表明该设计能够很好地满足工程实际需要。  相似文献   

9.
The coherent repopulation of a quantum system consisting of three nonequidistant levels in the field of a resonant bichromatic rf wave is studied. The atoms are assumed to have an impulsive interaction with the rf wave in which the pulse duration is less than any of the relaxation times. The hyperfine structure of gas atoms and a system of atomic oscillator levels in a magnetic trap are considered as examples of such a quantum system. It is shown that in the second case, the coherent repopulation effect can be used to cool neutral atoms in magnetic traps. Zh. éksp. Teor. Fiz. 113, 1181–1192 (April 1998)  相似文献   

10.
This paper reports on a detailed deformation model of varifocal liquid lenses fabricated by Parylene-on-liquid-deposition (POLD), which can be applied to measure and adjust the focal length of such lenses without using extra sensors or sensing mechanisms. The lens was fabricated by encapsulating a liquid between a transparent electrode and a polymer film that was covered with a metal electrode. When voltage is applied to the two electrodes, the lens deforms due to the electrostatic force, and its focal length and the capacitance between the two electrodes change simultaneously. This characteristic enables the focal length of the lens to be adjusted and detected by measuring the capacitance change. The focal length of the fabricated varifocal liquid lens changed from 153.6 to 82.6 mm by applying 150-V. The focal length change of the liquid lens was calculated from the change in its capacitance. Finally, to confirm the efficiency of this varifocal liquid lens, we fabricated a confocal distance sensor using the lens for laser scanning and demonstrated that this system can be used to measure distances of 94–140 mm with an average error of 0.83 mm and a standard deviation of 0.77 mm.  相似文献   

11.
Exposure of adult male mice to a magnetic resonance imaging (MRI) procedure has been shown to abolish the nocturnal analgesic responses observed following treatment with morphine. The field component(s) responsible for this inhibitory effect were examined by exposing mice to either the static, time-varying or rf magnetic field components associated with an MRI procedure. In the middle of the night portion of their day-night cycle, mice were exposed for 23.2 min to one of the above field components, intraperitoneally injected with morphine sulphate (10 mg/kg) and then exposed to the field conditions for another 23.2 min, after which analgesic responses were determined. Analgesia was quantitated by determining the length of time mice were content to be on a hot surface (50 degrees C) before they showed discomfort by licking their paws. It was observed that the time-varying magnetic field completely abolished, the rf field significantly reduced, while the static field component (0.15 T) had no evident effect on morphine-induced analgesia. These results indicate that the time-varying, and to a lesser extent the rf, fields associated with the MRI procedure inhibit morphine-induced analgesia in mice. These data also raise the possibility that exposure in humans to some of the magnetic field components associated with MRI may have clinically relevant effects on the actions of narcotic drugs such as morphine.  相似文献   

12.
尹向宝  刘永军  张伶莉  吕月兰  霍泊帆  孙伟民 《物理学报》2015,64(18):184212-184212
基于向列相液晶指向矢随施加电场作用发生变化的特性, 结合几何光学和液晶理论提出了一种液晶透镜结构模型, 研究了电极大小、隔垫物厚度等液晶透镜参数对液晶透镜焦距的影响. 通过优化参数, 得到结构简单、变焦范围较大的新型液晶透镜样品, 在驱动电压0 VRMS–250 VRMS下可调的焦距范围为75–230 mm, 达到155 mm.  相似文献   

13.
Modulating permanent magnet sextupole lens (PMSx) for focusing pulsed cold neutrons is under development. The synchronized modulation of its field gradient suppresses the chromatic aberration which arises from the Time Of Flight method. The strength of the magnetic field, the torque, and the rise of temperature during its operation are studied on a fabricated prototype. Experiments on focusing pulsed very cold neutrons (VCN) at ILL (Institute of Laue Langevin, France) were carried out and VCN with around λ=40 Å were focused by the PMSx at a focal length of about 0.5 m. The experimental results are presented in conjunction with the principle of the neutron focusing and the modulating method of the focal strength of permanent magnet lens with the double ring structure.  相似文献   

14.
15.
利用准直管法测凹透镜的焦距   总被引:1,自引:0,他引:1  
介绍了利用准直管精确测量凹透镜焦距的方法,该方法借助一个焦距较长的凸透镜与被测凹透镜组成无焦系统,可以使准直管出射光束的张角发生改变;用一辅助凸透镜与一测微目镜进行平行光束的会聚,测出准直管玻罗板线对在辅助凸透镜焦平面上所成像的大小;经过相应计算可得到被测凹透镜的焦距。  相似文献   

16.
The properties of an axisymmetric electrostatic lens used for focusing atomic or molecular beams were studied. The lens was formed by a dip in an electric field in the axial direction. Two types of interaction between the particles and the electric field were studied: quadratic and linear in field. An analytical approximation of the dependence of the focal distance of the lens on the beam energy and the parameters of the electric field was obtained. Chromatic and spherical aberrations of the lens were determined.  相似文献   

17.
提出一种数字全息定量测量半导体激光二极管侧面泵浦Nd∶YAG晶体热透镜效应的方法。CCD采集Nd∶YAG晶体在不同泵浦电流下的数字全息图,通过数值重建得到热透镜效应引起的相位分布及其变化过程。再由相位分布计算得到对应的热透镜焦距。实验结果表明,利用数字全息技术可以准确和有效测量热透镜效应及热透镜焦距。  相似文献   

18.
We propose to use diffractive optical element in combination with high NA lens axicon to achieve a high depth of focus when illuminated by a circularly polarized beam. With this kind of system, the focal depth is increased to 12.816λ and the magnetic spot size is reduced to 0.3764λ. However, in the conventional lens with same NA, the FWHM of the magnetic spot is found to be 0.4308λ and its corresponding magnetization depth is only 0.888λ. The author expects that such a high focal depth strong longitudinal magnetic field with large magnetization depth can be widely used in high density magneto optic recording, laser machining, laser cutting and the scanning near-field magnetic microscope.  相似文献   

19.
一种利用傅立叶频谱测量透镜焦距的新方法   总被引:2,自引:0,他引:2  
本文介绍了一种利用傅立叶频谱测量球面透镜、柱面透镜及环曲面透镜单色光焦距的新方法,这种新方法不需要高精度的平行光管,用激光器作为光源,仪器调式简单,测量结果可靠,测量精度可达0.3%。如果采用光电扫描及微机处理,这种方法还可以实现自动化测量,而且可以测量不可见光工作情况下的透镜焦距。  相似文献   

20.
We develop a theoretical model to describe the radio-frequency (rf) induced coupling of a pair of colliding atoms to a Feshbach molecule when a magnetic field arbitrarily far from the Feshbach resonance is modulated in time. We use the dressed atom picture, and show that the coupling strength in presence of rf is equal to the Feshbach coupling strength multiplied by the square of a Bessel function. The argument of this function is equal to the ratio of the atomic rf Rabi frequency to the rf frequency. We experimentally demonstrate this law by measuring the rate of rf-association of molecules using a Feshbach resonance in d wave collisions between ultra-cold chromium atoms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号