首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
《Analytical letters》2012,45(17):3177-3186
Abstract

A capillary electrophoresis (CE) method for the simultaneous separation of geometry isomers and enantiomers of nateglinide was built. Several different dyclodextrin (CD) derivatives were tested for the chiral separation of nateglinide, and it was proved that ionic CDs [i.e., carboxymethy-β-CD (CM-β-CD) and sulphonic-β-CD (S-β-CD)] could show better chiral selectivity for both geometry isomers and enantiomers than the neutral CDs. The separation of geometry of both isomers and enantiomers of nateglinide was obtained by CE in a 75-µm i.d. × 60 cm (effective length 45 cm) fused-silica capillary at 11 kV voltage, while 30 mM phosphate (pH = 8.38) acted as running buffer and a mixture of 40 mM S-β-CD + 21 mM CM-β-CD served as chiral selector. The detective wavelength was set at 254 nm.  相似文献   

2.
Separations of neutral and basic racemates were performed using five different anionic cyclodextrin (CD) derivatives as chiral selectors, viz. carboxymethylated β-CD, β-CD phosphate sodium salt, sulfobutyl ether β-CD sodium salt, carboxymethylated γ-CD, and γ-CD phosphate sodium salt. For the separation of neutral racemates, an untreated fused silica capillary was employed and various neutral racemates were successfully separated. Since the pH of the buffer affected the electroosmotic flow (EOF), the resolution was improved by changing the buffer pH. A polyacrylamide coated capillary was employed for the separation of basic racemates to suppress EOF and to prevent adsorption of cationic analyte on the capillary surface. By choosing an appropriate type and concentration of anionic CD, about 40 basic racemates were successfully separated. Some rough binding constants of basic analytes with an anionic β-CD were measured to discuss the optimum concentration of the CD. The migration direction was dependent on the binding constants and the concentration of the CD. The analyte strongly bound to the anionic CD migrated towards the anode but the weakly bound one moved towards the cathode. Anionic γ-CDs were also very useful for the separation of basic enantiomers. Five neutral CDs were employed as chiral selectors to compare selectivity between charged and neutral CDs, and eleven racemates could only be resolved using anionic CDs. The separation of some basic racemates in human plasma was also described. The direct injection of plasma samples was possible for some enantiomers that did not interact strongly with plasma proteins.  相似文献   

3.
Novel capillary electrophoresis methods using CDs as chiral selectors were developed and validated for the chiral separation of lansoprazole and rabeprazole, two proton pump inhibitors. Fourteen different neutral and anionic CDs were screened at pH 4 and 7 in the preliminary analysis. Sulfobutyl‐ether‐β‐CD with a degree of substitution of 6.5 and 10 at neutral pH proved to be the most suitable chiral selector for both compounds. Various dual CD systems were also compared, and the possible mechanisms of enantiomer separation were investigated. A dual selector system containing sulfobutyl‐ether‐β‐CD degree of substitution 6.5 and native γ‐CD proved to be the most adequate system for the separations. Method optimization was carried out using an experimental design approach, performing an initial fractional factorial screening design, followed by a central composite design to establish the optimal analytical conditions. The optimized methods (25 mM phosphate buffer, pH 7, 10 mM sulfobutyl‐ether‐β‐CD/20 mM γ‐CD, +20 kV voltage; 17°C temperature; 50 mbar/3 s injection, detection at 210 nm for lansoprazole; 25 mM phosphate buffer, pH 7, 15 mM sulfobutyl‐ether‐β‐CD/30 mM γ‐CD, +20 kV voltage; 18°C temperature; 50 mbar/3 s injection, detection at 210 nm for rabeprazole) provided baseline separation for lansoprazole (Rs = 2.91) and rabeprazole (Rs = 2.53) enantiomers with favorable migration order (in both cases the S‐enantiomers migrates first). The optimized methods were validated according to current guidelines and proved to be reliable, linear, precise, and accurate for the determination of 0.15% distomer as chiral impurity in dexlansoprazole and dexrabeprazole samples.  相似文献   

4.

Two separation techniques were developed for the determination of S-(−)darifenacin (DAR) in the presence of its R-(+) isomer: The first method is high performance liquid chromatography (HPLC) and the second is capillary electrophoresis (CE). Chiral separation for chromatographic HPLC method development was carried out for S-DAR on Daicel CROWNPAK CR (+) (5 μm, 4.0 × 150 mm) column which contains (3,3-diphenyl-1,1-binaphthyl)-crown-6 coated onto a 5.5 μm silica support. The mobile phase system was aqueous acidic 70 % HClO4 (pH 2.5): methanol in the proportion of 90:10 v/v. This current mobile phase was delivered at flow rate 0.8 mL min−1 using UV detector adjusted at 286 nm. In CE method, the enantiomers were separated using 50 μm inner diameter fused-silica capillary cut to total lengths of 31.2 cm using 50 mM phosphate buffer as background electrolyte adjusted to pH 2.5 by triethanolamine. A wide range of cyclodextrins (CDs) were used such as highly sulfated α, γ CDs, hydroxyl propyl-β-CD and sulfobutyl ether-β-CD as chiral selectors. The effects of chiral additives regarding its concentration and content of organic modifier on the enantioseparation were investigated. Linear concentration ranges were from 2.5 to 50 and 40 to 300 μg mL−1 with detection limits 0.67 and 12.28 μg mL−1 for chromatographic HPLC and electrophoretic CE methods, respectively. The two methods were validated according to ICH guidelines with respect to linearity, accuracy, precision, LOQ, LOD and robustness. The suggested methods are suitable for separation and quantitation of S-DAR in tablets.

  相似文献   

5.
The enantiomeric separation of chiral pharmaceuticals was investigated using dual systems with mixtures of cyclodextrin derivatives. The dual cyclodextrin systems, consisting of one highly-sulfated (α-, β-, and γ-HSCD) and one neutral cyclodextrin, i.e. either heptakis (2,3,6-tri-O-methyl)-β-CD (TMCD), heptakis (2,6-di-O-methyl)-β-CD (DMCD) or hydroxypropyl-β-CD (HPCD), are tested on 25 pharmaceutical compounds with different acid-basic properties (16 basics, 8 acids and 1 neutral). The influence on the separation of the type and concentration of neutral CD in highly-sulfated cyclodextrins-based dual selector systems, is investigated. For 11 of 16 basic compounds, a better separation is obtained with the CD mixtures compared to the use of only a highly-sulfated CD. Mixtures with TMCD give better results than those with DMCD and HPCD. Results showed that dual CD systems are useful to achieve and to optimise chiral separations of compounds not (sufficiently) separated with HSCDs alone. For example, ibuprofen was not resolved with α-, β- or γ-HSCD, but could be separated with the mixture 25 mM TMCD and 5% HS-β-CD. Based on the obtained results, a dual CD systems based separation strategy is defined.  相似文献   

6.
R-solriamfetol is a recently approved drug used for the treatment of excessive sleepiness associated with narcolepsy and sleep apnea. Herein, a capillary electrophoretic method was developed, enabling the simultaneous analysis of the API and its S-enantiomer in addition to the enantiomers of its major impurity phenylalaninol. Twenty-nine different cyclodextrins (CDs), including native, neutral, and charged ones were screened as potential chiral selectors, and the best results were obtained with sulfated CDs. Randomly sulfated-β-CD exhibited outstanding enantioresolution, the peaks of phenylalaninol enantiomers inserted between the two peaks of solriamfetol enantiomers, while sulfated-γ-CD (S-γ-CD) showed remarkable resolution values in a much shorter analysis time with the optimal enantiomer migration order. Among the single isomer sulfated CD derivatives, substituent dependent enantiomer migration order reversal could also be observed in the case of heptakis(6-O-sulfo)-β-CD (HS-β-CD) or heptakis(2,3-O-dimethyl-6-O-sulfo)-β-CD (HDMS-β-CD) with R-,S-solriamfetol, and heptakis(2,3-O-diacetyl-6-O-sulfo)-β-CD (HDAS-β-CD) resulting S-,R-solriamfetol migration order. The sulfated-γ-CD system was chosen for method optimization applying orthogonal experimental design. The optimized method (45 mM Tris-acetate buffer, pH 4.5, 4 mM S-γ-CD, 21°C, +19.5 kV) was capable for the baseline separation of solriamfetol and phenylalaninol enantiomers within 7 min. The optimized method was validated according to the ICH guidelines and successfully applied for the analysis of pharmaceutical preparation (Sunosi® 75 mg tablet), thus it may serve as a routine procedure for the laboratories of regulatory authorities as well as in Pharmacopoeias.  相似文献   

7.
Szwed  Kamila  G&#;recki  Marcin  Frelek  Jadwiga  Asztemborska  Monika 《Chromatographia》2013,76(23):1603-1611

The distribution coefficients and enantioseparation of cyclopentolate were studied in an extraction system containing d-tartaric acid ditertbutyl ester in organic phase and 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) in aqueous phase. Various parameters involved in the enantioseparation such as the type and the concentration of chiral selectors, pH value and a wide range of organic solvents were investigated. The maximum enantioselectivity (α = 2.13) and optimum distribution coefficients (K R = 0.85, K S = 0.40) were obtained under the following conditions: 0.10 mol/L HP-β-CD in aqueous phase and 0.20 mol/L d-tartaric acid ditertbutyl ester in decanol as organic phase. Cyclopentolate is present as a racemic mixture to the aqueous phase. The potentially different biological activities of cyclopentolate enantiomers have not been examined yet. Two chiral liquid chromatography methods have been developed for the direct separation of the enantiomers of cyclopentolate. First method was used for the quantification analysis of cyclopentolate enantiomers in aqueous phase. Second method used two chiroptical detectors: electronic circular dichroism (ECD) and optical rotation (OR) for the identification of individual cyclopentolate enantiomers from the organic phase enriched with (R)-enantiomer. The absolute stereochemistry was determined by means of the comparison of the experimental and computed ECD spectra and signs of OR. The ECD spectra of chiral analytes were measured on-line using HPLC-ECD technique.

  相似文献   

8.
Krait  Sulaiman  Dou&#;a  Michal  Scriba  Gerhard K. E. 《Chromatographia》2016,79(19):1343-1350

A quality by design approach utilizing experimental design methodologies was applied to develop a CE method to evaluate the enantiomeric purity of (S)-ambrisentan, a selective endothelin receptor antagonist used for the treatment of pulmonary arterial hypertension. Initial method scouting was performed by screening native cyclodextrins (CDs) as well as neutral CD derivatives and a positively charged derivative at pH 5 and pH 9, identifying γ-CD as suitable selector at pH 5. Upon defining the critical quality attributes and the critical process parameters, i.e., chiral resolution and run time, method development was performed by application of a screening design for the identification of the significant variables and, subsequently, by a response surface methodology for obtaining the design space. A Plackett–Burman design was employed for robustness testing. The final working point conditions used a background electrolyte composed of a 50-mM sodium acetate buffer, pH 4.0, containing 30 mM γ-CD in a 75-μm ID fused-silica capillary with an effective length of 40 cm at an applied voltage of 25 kV and a capillary temperature of 25 °C. The method was validated according to the ICH Q2(R1) guideline and allowed the determination of a relative concentration of the (R)-enantiomer of 0.1 %.

  相似文献   

9.
A CE method using CDs as chiral selectors was developed and validated to achieve the separation of glycidyl tosylate enantiomers originated by in situ derivatization of glycidol enantiomers obtained in asymmetric epoxidation of allyl alcohol with chiral titanium‐tartrate complexes as catalysts. The effects of the nature, pH and concentration of the buffer, the nature and concentration of chiral selector, the addition of SDS, methanol, ethanol or 2‐propanol, the capillary temperature, the effective capillary length and the applied voltage on the chiral resolution of glycidyl tosylate enantiomers were investigated. The best separation conditions were achieved using a Tris‐borate buffer mixture (50 and 25 mM, respectively) at pH=9.3 with a dual CD system consisting of 2.5% succinyl‐β‐CD and 1.0% β‐CD w/v at 15°C. A baseline separation (resolution~2.0) of the glycidyl tosylate enantiomers was obtained in a relatively short time (less than 12 min). Satisfactory results were obtained in terms of linearity (r>0.99) and intermediate precision (RSD below 8.5%). The LOD and LOQ were 3.0 and 10.0 mg/L, respectively, and the recoveries ranged from 99.8 to 108.8%. Finally, the method was applied to the determination of the enantiomeric excess and the yield obtained in the asymmetric epoxidation of allyl alcohol employing chiral titanium‐tartrate complexes as catalysts after an in situ derivatization of glycidol enantiomers to glycidyl tosylate.  相似文献   

10.
An efficient method for the simultaneous enantioseparation of cyproconazole, bromuconazole, and diniconazole enantiomers was developed by CD‐modified MEKC using a dual mixture of neutral CDs as chiral selector. Three neutral CDs namely hydroxypropyl‐β‐CD, hydroxypropyl‐γ‐CD, and γ‐CD were tested as chiral selectors at different concentrations ranging from 10, 20, 30 and 40 mM, but enantiomers of the studied fungicides were not completely separated. The best dual chiral recognition mode for the simultaneous separation of cyproconazole, bromuconazole, and diniconazole enantiomers was achieved with a mixture of 27 mM hydroxypropyl‐β‐CD and 3 mM hydroxypropyl‐γ‐CD in 25 mM phosphate buffer (pH 3.0) containing 40 mM SDS to which methanol‐acetonitrile (10%:5% v/v) was added as organic modifiers. The best separation was based on the appearance of 10 peaks simultaneously, with good resolution (Rs 1.1–15.9), and peak efficiency (N>200 000). Good repeatabilities in the migration time, peak area, and peak height were obtained in terms of RSD ranging from (0.72 to 1.06)%, (0.39 to 3.49)%, and (1.90 to 4.84)%, respectively.  相似文献   

11.
This study details the use of two permanently positively charged mono-substituted β-cyclodextrin derivatives, 6I -deoxy-6I-(N,N N′,N′,Nt’-pentamethyl-ethylene-1,2-diammonio)-cyclomaltoheptose dichloride (PEMEDA-β-CD) and the newly synthesised 6I-deoxy-6I-(N,N,N′,N′,N′-pentamethyl-propylene-1,3-diammonio)-cyclomaltoheptose (PEMPDA-β-CD) as chiral selectors in capillary electrophoresis. Cyclodextrin (CD) derivatives were tested as additives in various buffers at various pH values with the optional addition of an organic modifier. Fourteen anionogenic analytes were tested, including native amino acids, N-blocked amino acids and profens, which were detected using a UV-VIS detector at optimal wavelengths of 214 nm, 254 nm or 280 nm. A borate buffer (15 mmol L?1) at pH 9.5 without the addition of an organic modifier was chosen as a suitable background electrolyte. In addition, the effect of the concentration of the chiral selector on the separation and enantioseparation of selected analytes was monitored. The additions of cyclodextrin derivatives varied within the concentration range of 0.0–5.0 mmol L?1. Both chiral selectors were suitable for the enantioseparation of N-Boc-d,l-tryptophan, which was already separated on the baseline at 0.5 mmol L?1 concentration of the chiral selector.  相似文献   

12.
The enantioselectivity of three chiral selectors, 6-t-butyldimethyl-silyl-2,3-dimethyl-α-, β- and γ-cyclodextrin (TB-α-CD, TB-β-CD, TB-γ-CD), are compared and discussed for a range of chiral test compounds. TB-β-CD in particular offers high enantioselectivity for a variety of chiral compounds and has the special property of excellent solubility in different alkylpolysiloxanes, including the weakly polar variety, because of its weak self-association. To investigate the influence of the polarity of polysiloxane matrices this selector can be used at a wide range of concentrations in the most suitable polysiloxane matrices and at low separation temperatures without impairment of resolution by peak broadening and symmetry distortion.  相似文献   

13.
A fast capillary electrophoretic method is described for the separation and determination of the enantiomers of the novel wake-promoting agent, modafinil. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, buffer concentration, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 5 min with resolution factor Rs?=?2.51, using a bare fused-silica capillary and a background electrolyte (BGE) of 25 mM H3PO4?1 M tris solution; pH 8.0; containing 30 mg mL?1 of sulfated-β-cyclodextrin (S-β-CD). The separation was carried out in normal polarity mode at 25 ?C, 18 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were included. The developed method was successfully applied to the assay of enantiomers of modafinil in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the modafinil enantiomers.  相似文献   

14.
Chiral separation method development is usually very time-consuming due to the diversity in chemical structures of pharmaceutical drug substances as well as the suitable separation conditions and the problem to choose the appropriate chiral selector. This paper shows capillary zone electrophoresis (CZE) which was developed for chiral separation of a basic compound - rivastigmine (RIV) using 30 cm × 50 μm i.d. polyacrylamide (PAA)-coated fused-silica capillary (effective length 20 cm), amine-modified phosphate buffer of pH 2.5 and sulfated-β-CD (S-β-CD) as chiral selector. Other selected native or derivatized cyclodextrins (CDs) were also tested: β-CD (5, 30 mM), carboxymethyl-β-CD (5, 30 mM), dimethyl-β-CD (15 mM), hydroxypropyl-β-CD (5, 30 mM), hydroxypropyl-α-CD (5, 30 mM) and hydroxypropyl-γ-CD (5, 30 mM). Complete enantiomeric separation of RIV was achieved at 20 kV, 18 °C and detection at 200 nm within 8 min with R.S.D. for the absolute migration time reproducibility of less than 2.1%. Rectilinear calibration range was 5.0-500.0 μM of each enantiomer (r = 0.9994-0.9995). The CZE method proposed was used for the control of chiral purity of pharmaceutically active S-RIV and for the analysis of Exelon caps preparation.  相似文献   

15.
Three new chiral selectors, 6-tert-butyldimethylsilyl-2,3-diethyl-a-cyclodextrin, 6-tert-butyldimethylsilyl-2,3-diethyl- and dipropyl-β-cyclodextrin (TBDE-α-CD, TBDE-β-CD, TBDP-β-CD) were synthesized and tested as chiral stationary phases in capillary gas chromatography. TBDE-β-CD in particular showed a high enan-tioselectivity for test chiral compounds due to good solubility in a polar polysiloxane (OV-1701). Enantioselectivity obtained with TBDE-β-CD was compared with that of 6-tert-butyldimethylsilyl-2,3-di-O-methyl-β-cyclodextrin (TBDM-β-CD). Better enantiose-lectivity was obtained with TBDE-P-CD than with TBDM-β-CD for the test chiral compounds studied. This is probably due to greater effect of the increased hydrophobicity of TBDE-β-CD which favors inclusion of the analytes than the effect of increased steric hindrance. With TBDP-β-CD the less polar lactones are well separated due most likely to increased hydrophobicity of the propyl groups while the more polar are not well resolved. For TBDP-β-CD it is likely that the unfavorable steric hindrance is predominant over the favorable hydrophobicity of the propyl groups, thus hindering the formation of inclusion complexes of the alcohols with TBDP-β-CD. TBDE-α-CD was also a valuable chiral selector for the separation of small chiral molecules such as simple secondary alcohols and nitro-substituted alcohols.  相似文献   

16.
A new solvent sublation (SS) system for chiral separation is introduced by using phenylsuccinic acid (H2A) as the model enantiomers. The experiments were carried out in a traditional SS apparatus but with collaborative chiral selectors: dibenzoyl-L-tartaric acid (L-DBTA) in the organic phase and hydroxypropyl-β-cyclodextrin (HP-β-CD) in the aqueous phase. The chiral recognition abilities of the two selectors are opposite for the H2A enantiomers. Several important parameters were investigated. The results demonstrate that enantioselective sublation and partitioning behavior are mainly dependent on the pH of the solution, the concentrations of chiral selectors and H2A. Furthermore, the flow rate of air and flotation time also have some effects on the enantioseparation. Under the optimized conditions, the enantioselectivity expressed by the separation factor (β) and enantiomer excess (e.e.%) are 2.47 and 29.50%, and the yields of R-H2A and S-H2A are 0.23 and 0.13 g·L?1, respectively. Compared with the SS system with the single selector HP-β-CD in the aqueous phase (or L-DBTA in the organic phase), the increased values of β and e.e.% in the new SS system with collaborative selectors are 1.31 (or 1.38) and 5.90% (or 13.82%), respectively.  相似文献   

17.
Capillary electrophoresis (CE) is a powerful separation technique that was used in a wide range of analytical chemical applications. Cyclodextrins(CDs) are the most commonly used chiral selectors in chiral capillary electrophoresis at the present time. Under neutral conditions, however, native CDs are neutral and usually applicable only for the enantioseparation of charged analyses. To overcome this defect we modified α- and β-CD with a L-cysteine moiety and used the CD derivatives as chiral selectors for the separation of a-amino acid enantiomers by the ligand exchange mode.  相似文献   

18.
The enantiomer migration order (EMO) of ephedrine was investigated in the presence of various CDs in CE. The molecular mechanisms of chiral recognition were followed for the ephedrine complexes with native α- and β-CD and heptakis(2,3-di-O-acetyl-6-O-sulfo)-β-CD (HDAS-β-CD) by CE, NMR spectroscopy and high-resolution MS. Minor structural differences were observed between the complexes of ephedrine with α- and β-CD although the migration order of enantiomers was opposite when these two CDs were applied as chiral selectors in CE. The EMO was also opposite between β-CD and HDAS-β-CD. Significant structural differences were observed between ephedrine complexes with the native CDs and HDAS-β-CD. The latter CD was advantageous as chiral CE selector not only due to its opposite electrophoretic mobility compared with that of the cationic chiral analyte, but also primarily due to its enhanced chiral recognition ability towards the enantiomers of ephedrine.  相似文献   

19.
In the past decade, ionic liquids have received great attention owing to their potential as green solvent alternatives to conventional organic solvents. In this work, hydrophobic achiral ionic liquids (1-butyl-3-methylimidazolium-hexafluorophosphate([bmim][PF6]), 1-octyl-3-methylimidazolium tetrafluoroborate([omim][BF4])) were used as solvents in chiral liquid-liquid extraction separation of mandelic acid (MA) enantiomers with β-cyclodextrin (β-CD) derivatives as hydrophilic chiral selectors preferentially forming complexes with (R)-enantiomers. Factors affecting the separation efficiency were optimised, namely the type of the extraction solvents and β-CD derivatives, concentrations of the β-CD derivatives and MA enantiomers, pH, and temperature. Excellent enantioseparation of MA enantiomers was achieved in the ionic liquid aqueous two-phase extraction systems under the optimal conditions of pH 2.5 and temperature of 5°C with the maximum enantioselectivity (α) of 1.74. The experimental results demonstrated that the ionic liquid aqueous two-phase extraction systems with a β-CD derivative as the chiral selector have a strong chiral recognition ability, which might extend the application of ionic liquids in chiral separation.  相似文献   

20.
As a continuation of previous studies on the use of cyclodextrin derivatives (CD) for the separation of volatile compounds by capillary GC, the influence of diluting phases other than OV-1701 or OV-1701-OH has been investigated. 2,6-Di-O-methyl-3-O-pentyl-β-cyclodextrin (2,6-DiMe-3-Pe-β-CD) was taken as the reference CD derivative, because of the large number of volatile racemates it is able to separate; OV-1701 or OV-1701-OH was chosen as the reference diluting phase. The performance of a column coated with a 0.15 μm film of 10 % 2,6-DiMe-3-Pe-β-CD in OV-1701 was compared with that of analogous columns coated with films of the same thickness containing the same percentage of the CD derivative diluted with stationary phases of different polarity, i.e. PS-086, PS-347.5, and OV-225. Resolution values and separation factors of thirty racemates were used to evaluate the effect of different diluting phases on column performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号