首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.  相似文献   

2.
Novel monolithic capillary supports (200 microm I.D.) were prepared by polymerisation of methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE) as a crosslinker in the presence of inert diluents (porogens). These polymeric reversed-phases (MS/BVPE) showed excellent mechanical stability and minimised swelling in organic solvents. The chromatographic potential of monolithic MS/BVPE as a stationary phase for micro-high-performance liquid chromatography (mu-HPLC) was investigated by the separation of proteins and peptides applying reversed-phase (RP) and nucleic acids applying ion-pair reversed-phase (IP-RP) conditions. The permeability and chromatographic efficiency of the capillary columns were found to be highly influenced by the total monomer to porogen content as well as by the microporogen nature and its ratio. In the course of these optimisation studies, monoliths covering a broad permeability range were fabricated. The application of volumetric flow rates up to 200 microl/min allowed swift resolution of proteins, while smaller biomolecules were successfully separated at a higher overall porosity. A protein test mixture containing ribonuclease A, cytochrome c, alpha-lactalbumin, beta-lactoglobulin B and ovalbumin was thus baseline separated in 35s, a homologous series of phosphorylated oligothymidylic acids [d(pT)12-18] in less than 2 min.  相似文献   

3.
A mixture of ten proteins was trypsinized and injected onto poly-(styrene-divinylben-zene) monolithic columns (60 x 0.20 or 0.10 mm ID) and a column packed with C18 silica particles (75 x 0.075 mm ID), respectively. The columns were eluted at 200-2000 nL/min with gradients of ACN in 0.050% TFA. Eluting peptides were detected by ESI-MS/MS and subsequently identified by database searching. The 100 microm ID monolithic column showed the highest cumulative Mowse scores based on the highest ion scores for the peptides and the largest number of identified peptides. It is shown that the number of identified peptides strongly depends on the dynamic range within the peptide mixture. In consequence, all proteins were identified in a mixture of relatively balanced analyte amounts (12.5-80 fmol) whereas only peptides for six out of ten proteins were found in a sample of high-dynamic range (0.65-270 fmol). The 100 microm monolithic column showed the highest reproducibility for peptide identifications in three consecutive runs. Depending on sample amount, 57-72% of the identified peptides were detectable in each of the three runs of triplicate analyses. The results demonstrate the high suitability of 100 microm monolithic columns for high-resolution peptide separations in proteomic research.  相似文献   

4.
Monolithic columns based on poly-(styrene-divinylbenzene) (PS-DVB) were utilized both for preconcentration (in 10 mm x 0.20 mm I.D. format) and analytical separation (in 60 mm x 0.20 and 0.10 mm I.D. format) of peptides and proteins in column switching micro-scale high-performance liquid chromatography. A special holder for short monolithic preconcentration columns was designed and pressure durability tests approved long-term stability up to 400 bar. An 11-20% decrease in the average peak widths of nine peptides was obtained upon combining a preconcentration column with an analytical column as compared with a setup using an analytical column only. Trapping efficiency, especially for small and hydrophilic peptides, was optimized by using 0.10% heptafluorobutyric acid instead of 0.050% trifluoroacetic acid as solvent additive during sample loading. Using a 10 mm x 0.20 mm I.D. preconcentration column, loadabilities between 0.5 and 1.6 microg were determined by frontal analysis of proteins and bioactive peptides, respectively. A 100-fold concentration followed by direct on-line intact mass determination is demonstrated for diluted (3 micromolL(-1)) protein solutions. The applicability of the monolithic preconcentration column for multidimensional chromatography was tested by off-line two-dimensional separation, combining strong cation-exchange chromatography and ion-pair reversed-phase chromatography. Peptide identification data from digested protein mixtures demonstrated reproducibilities of 46-75% in triplicate analyses, and confident peptide identifications of low abundant peptides even in the presence of a 650-fold molar excess of high abundant peptides.  相似文献   

5.
Monolithic capillary columns were prepared via electron beam triggered free radical polymerization within the confines of 0.2 and 0.1mm I.D. capillary columns using ethyl methacrylate and trimethylolpropane triacrylate as monomers as well as 2-propanol, 1-dodecanol and toluene as porogenic system. The influence of column diameter on reproducibility and separation performance was investigated. For evaluation, a protein standard consisting of five proteins in the range of 5800-66,000 g mol(-1) was used. Reproducibility was checked by determining the relative standard deviations in retention times, peak widths at half height, asymmetry and resolution. Excellent run-to-run reproducibility was found for both 0.2 and 0.1mm I.D. columns; batch-to-batch reproducibility was good for both column types. In order to enhance the non-polar character of the monolithic columns, lauryl methacrylate-based capillary columns were prepared. These were successfully used for the separation of proteins and a cytochrome c digest.  相似文献   

6.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

7.
Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.  相似文献   

8.
Hydrophobic organo-silane based monolithic capillary columns were prepared by thermally initiated free radical polymerisation within the confines of 200 microm i.d. fused silica capillaries. A novel crosslinker, namely bis(p-vinylbenzyl)dimethylsilane (BVBDMS), was copolymerised with p-methylstyrene (MS) in the presence of 2-propanol and toluene, using alpha,alpha'-azoisobutyronitrile (AIBN) as initiator. Monolithic capillary columns, differing in the total monomer, microporogen content and microporogen nature were fabricated and the chromatographic efficiency of each monolith, regarding the separation of proteins, peptides and oligonucleotides, was evaluated and compared. Changes in monolith morphology were monitored by scanning electron microscopy (SEM). Porosity and specific surface areas of the supports were studied by means of mercury intrusion porosimetry and BET measurements, respectively. Pressure drop vs. flow rate measurements proved the prepared poly(p-methylstyrene-co-bis(p-vinylbenzyl)dimethylsilane) (MS/BVBDMS) monoliths to be mechanically stable and swelling propensity (SP) factors of 0.78-1.10 indicate high crosslinking homogeneity.  相似文献   

9.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

10.
This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.  相似文献   

11.
Oligonucleotides and double stranded DNA fragments were separated in 200 microm I.D. capillary columns packed with micropellicular, octadecylated, 2.1 microm poly(styrene-divinylbenzene) particles by ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC). Both the length and the diameter of the connecting capillaries (150 x 0.020 mm I.D.) as well as the detection volume (3 nl) had to be kept to a minimum in order to maintain the high efficiency of this chromatographic separation system with peak widths at half height in the range of a few seconds. Three different types of frits, namely sintered silica particles, sintered octadecylsilica particles, and monolithic poly(styrene-divinylbenzene) (PS-DVB) frits were evaluated with respect to their influence on chromatographic performance. Best performance for the separation of oligonucleotides and long DNA fragments was observed with the PS-DVB frits, whereas the short DNA fragments were optimally resolved in columns terminated by octadecylsilica frits. The maximum loading capacity of 60 x 0.20 mm I.D. columns ranged from 20 fmol (7.7 ng) for a 587 base pair DNA fragment to 500 fmol (2.4 ng) for a 16-mer oligonucleotide. Lower mass- and concentration detection limits in the low femtomol and low nanomol per liter range, respectively, make capillary IP-RP-HPLC with UV absorbance detection highly attractive for the separation and characterization of minute amounts of synthetic oligonucleotides, DNA restriction fragments, and short tandem repeat sequences amplified by polymerase chain reaction.  相似文献   

12.
We prepared 0.53 and 0.32 mm id monolithic microcolumns by in situ copolymerization of a zwitterionic sulfobetaine functional monomer with bisphenol A glycerolate dimethacrylate (BIGDMA) and dioxyethylene dimetacrylate crosslinkers. The columns show a dual retention mechanism (hydrophilic‐interaction mode) in acetonitrile‐rich mobile phases and RP in highly aqueous mobile phases. The new 0.53 mm id columns provided excellent reproducibility, retention, and separation selectivity for phenolic acids and flavonoids. The new zwitterionic monolithic columns are highly orthogonal, with respect to alkyl silica stationary phases, not only in the hydrophilic‐interaction mode but also in the RP mode. The optimized monolithic zwitterionic microcolumn of 0.53 mm id was employed in the first dimension, either in the aqueous normal‐phase or in the RP mode, coupled with a short nonpolar core‐shell column in the second dimension, for comprehensive 2D LC separations of phenolic and flavonoid compounds. When the 2D setup with the sulfobetaine–BIGDMA column was used for repeated sample analysis, with alternating gradients of decreasing (hydrophilic‐interaction mode), and increasing (RP mode) concentration of acetonitrile on the sulfobetaine–BIGDMA column in the first dimension, useful complementary information on the sample could be obtained.  相似文献   

13.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

14.
A novel single-step sol-gel approach for the preparation of beta-CD-bonded silica monolithic electrochromatographic columns is established. The porous silica networks were fabricated inside fused-silica capillaries using sol-gel processing of tetramethoxysilane and an organfunctional silicon alkoxide that contains beta-CD. Scanning electron micrographs and nitrogen adsorption-desorption data showed that these functional monolithic columns have double pores structures with micrometer-size co-continuous through-pores and silica skeletons with open mesopores. The beta-CD monolithic columns have successfully been applied to the separation of several neutral and negatively charged isomers by CEC. The column performance was evaluated by using positional isomers of naphthalenedisulfonic acid as model compounds. A plate height of less than 10 mum for the first eluted isomer of naphthalenedisulfonic acid was obtained at an optimal flow rate (0.47 mm/s) of the mobile phase. Moreover, the columns have been proved to be stable for more than 100 runs during 3 months period and show reasonable column reproducibility.  相似文献   

15.
Bones J  Macka M  Paull B 《The Analyst》2007,132(3):208-217
A study comparing recently available 100 x 3 mm id, 200 x 3 mm id monolithic reversed-phase columns with a 50 x 2.1 mm id, 1.8 microm particle packed reversed-phase columns was carried out to determine the most efficient approach (using traditional van Deemter analysis and a modern kinetic plot approach) for the rapid screening of samples for 16 illicit drugs and associated metabolites. A plot of column backpressure versus plate number (N) showed a significant advantage of using the monolithic phases, with the 20 cm monolithic column exhibiting a maximum 15,000 plates at a column backpressure of approximately 70 bar, compared to approximately 7000 plates at 150 bar for the 5 cm 1.8 microm particle packed column. Optimum linear velocities were found to be 0.40 mm s(-1), 0.52 mm s(-1) and 0.98 mm s(-1) for the three above columns, respectively. The 20 cm monolithic column was subsequently applied to the separation and determination of illicit drug contamination on Irish euro banknotes, using methanol extraction followed by LC-MS/MS. Method performance data showed that the new LC-MS/MS method was significantly more sensitive than previous GC-MS/MS based methods for this application, with detection limits in the pg note(-1) region, based upon a 20 microL standard injection. All of the notes examined tested positive for trace quantities of cocaine, with benzoylecgonine detected on 12 of the 45 notes sampled. Traces of heroin were also detected on three of the 45 notes.  相似文献   

16.
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.  相似文献   

17.
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.  相似文献   

18.
Butyl methacrylate monolithic columns in 320 microm i.d. fused silica capillaries for reversed-phase capillary liquid chromatography were prepared by radical polymerization initiated thermally with azobisisobutyronitrile (AIBN). Polymerization mixture contained butyl methacrylate (BMA) as the function monomer and ethylene dimethacrylate (EDMA) as the crosslinking agent with 1,4-butanediol and 1-propanol as a binary porogen solvent. Ratio of 1,4-butanediol to 1-propanol in the porogen solvent was optimized regarding the monolithic column efficiency and performance. Total porosity, column permeability, separation impedance, Walters hydrophobicity index, retention factors, peak asymmetry factors, height equivalents to a theoretical plate and peak resolutions were used for characterization of the prepared monolithic columns. The polymerization mixture consisting of 17.8% of BMA, 21.8% of EDMA, 18.0% of 1,4-butanediol, 42.0% of 1-propanol and 0.4% AIBN generated monolithic columns of the best performance having a sufficient permeability and the lowest separation impedance. It was also demonstrated that monolithic columns of this composition exhibited good preparation reproducibility and an excellent pressure resistance when applied in capillary liquid chromatography.  相似文献   

19.
In order to elucidate the effect of the polymerisation time on the morphology of styrene based monolithic support materials, continuous poly(1,2-bis(p-vinylphenyl))ethane (BVPE) rods were synthesised in 1.0 ml glass vials by thermally initiated free radical polymerisations of BVPE in the presence of porogens (toluene, decanol) and a,a′-azoisobutyronitrile (AIBN) as initiator at 65 °C for different polymerisation times (60, 90, 150, 300 and 600 min). Porosity parameters like pore-size-distribution and total porosity were investigated by mercury intrusion porosimetry, while the specific surface area of the BVPE monolithic supports was determined by N2-adsorption (BET) measurements. An untypical bimodal pore-size-distribution comprising a high fraction of both mesopores (2–50 nm) and macropores (mainly flow-channels in the micrometer range) was observed as a result of the stepwise decrease of the polymerisation time. In consequence of the significant changes of the pore-size-profile, shortening the polymerisation time also resulted in enhanced total porosity due to enlarged flow-channel diameters and increased surface area according to the presence of a considerable amount of mesopores. Results upon the porosity profile of the support are further confirmed by SEM images of monoliths polymerised for different time periods. Since mesoporosity and high surface area of the chromatographic support material play key roles in the interaction and thus retention of low-molecular-weight compounds, polymerisation time should also affect the chromatographic properties and applicability of these polymers. To study the influence of the polymerisation time towards the separation efficiency of small molecules on BVPE capillary columns (200 μm I.D., 8 cm), a mixture of homologous alkylbenzenes was chosen for column evaluation. In accordance with the observations of the porous properties of BVPE stationary phases, the rapid and high resolution separation of a range of low-molecular-weight compounds on monolithic BVPE supports were successfully realised. The methodical reduction of the polymerisation time has been demonstrated to be a simple and effective tool to tailor the porous properties of organic monoliths to provide novel polymer-based stationary phases with porous properties adequate for the rapid and high resolution chromatography of small organic molecules.  相似文献   

20.
This paper describes approaches to optimize the chromatographic performance for our recently developed LC-MS platform, extended range proteomic analysis (ERPA), for comprehensive protein characterization at the ultratrace level. Large digested peptide fragments up to 10 kDa (e.g., from lysyl endopeptidase digestion) with or without modifications were well separated with high resolution using narrow bore (20 and 50 microm I.D.) poly(styrene-divinylbenzene) (PS-DVB) monolithic columns constructed by in situ solution polymerization. Importantly, the macroporous structure of the monolithic columns facilitated mass transport of large peptides with improved recovery relative to small pore size reversed-phase packings. High sequence coverage (>95%), including identification of phosphorylated and glycosylated particles was achieved for beta-casein and epidermal growth factor receptor (EGFR) at the 4 and 20 fmol levels per injection, respectively, using the 20 microm I.D. PS-DVB monolithic column. For peptides with greater ionization efficiency, the detection limit could be lowered to approximately 400 zmol. Typically, the separation system produced a peak capacity of approximately 200 for a 10 cm column. This paper demonstrates that narrow-bore monolithic columns are suitable for high sensitivity and high-resolution separation of large peptide fragments by LC-MS analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号