1.
Interest in low-cost, analytical-scale, highly efficient and sensitive separation methods for cells, among which bacteria, is increasing. Particle separation in hollow-fiber flow field-flow fractionation (HF FlFFF) has been recently improved by the optimization of the HF FIFFF channel design. The intrinsic simplicity and low cost of this HF FlFFF channel allows for its disposable usage. which is particularly appealing for analytical bio-applications. Here, for the first time, we present a feasibility study on high-performance, hyperlayer HF FIFFF of micrometer-sized bacteria (Escherichia coli) and of different types of cells (human red blood cells, wine-making yeast from Saccharomyces cerevisiae). Fractionation performance is shown to be at least comparable to that obtained with conventional, flat-channel hyperlayer FIFFF of cells, at superior size-based selectivity and reduced analysis time.  相似文献   

2.
Flow field-flow fractionation (FIFFF) normally runs at a rectangular channel system constructed with two parallel blocks having permeable ceramic walls. In this work, a hollow fiber as another separation chamber for FIFFF system is utilized for the separation of nanoparticles and the separation efficiency in hollow-fiber flow field-flow fractionation (HF-FIFFF) has been greatly improved by experimentation.  相似文献   

3.
A new system design and setup are proposed for the combined use of asymmetrical flow field-flow fractionation (AF4) and hollow-fiber flow field-flow fractionation (HF5) within the same instrumentation. To this purpose, three innovations are presented: (a) a new flow control scheme where focusing flow rates are measured in real time allowing to adjust the flow rate ratio as desired; (b) a new HF5 channel design consisting of two sets of ferrule, gasket and cap nut used to mount the fiber inside a tube. This design provides a mechanism for effective and straightforward sealing of the fiber; (c) a new AF4 channel design with only two fluid connections on the upper plate. Only one pump is needed to deliver the necessary flow rates. In the focusing/relaxation step the two parts of the focusing flow and a bypass flow flushing the detectors are created with two splits of the flow from the pump. In the elution mode the cross-flow is measured and controlled with a flow controller device. This leads to reduced pressure pulsations in the channel and improves signal to noise ratio in the detectors. Experimental results of the separation of bovine serum albumin (BSA) and of a mix of four proteins demonstrate a significant improvement in the HF5 separation performance, in terms of efficiency, resolution, and run-to-run reproducibility compared to what has been reported in the literature. Separation performance in HF5 mode is shown to be comparable to the performance in AF4 mode using a channel with two connections in the upper plate.  相似文献   

4.
Flow field flow fractionation (FIFFF), one of the subtechniques in FFF family, is a separation technique that can be applied for the separation and characterization of particulate materials, biological macromolecules, and water soluble polymers. Separation in FIFFF is carried out in an empty channel by the interaction of applied field from an external source with flow. Retention of particles or macromolecules in FIFFF is governed by the relative protrusion of sample materials to the differential flow streamlines. Thus in FIFFF, particle size can be readily calculated from the experimental fractogram by theory or calibration.  相似文献   

5.
Biocompatible methods capable of rapid purification and fractionation of analytes from complex natural matrices are increasingly in demand, particularly at the forefront of biotechnological applications. Field-flow fractionation is a separation technique suitable for nano-sized and micro-sized analytes among which bioanalytes are an important family. The objective of this preliminary study is to start a more general approach to field-flow fractionation for bio-samples by investigation of the correlation between channel surface composition and biosample adhesion. For the first time we report on the use of X-ray photoelectron spectroscopy (XPS) to study the surface properties of channels of known performance. By XPS, a polar hydrophobic environment was found on PVC material commonly used as accumulation wall in gravitational field-flow fractionation (GrFFF), which explains the low recovery obtained when GrFFF was used to fractionate a biological sample such as Staphylococcus aureus. An increase in separation performance was obtained first by conditioning the accumulation wall with bovine serum albumin and then by using the ion-beam sputtering technique to cover the GrFFF channel surface with a controlled inert film. XPS analysis was also employed to determine the composition of membranes used in hollow-fiber flow field-flow fractionation (HF FlFFF). The results obtained revealed homogeneous composition along the HF FlFFF channel both before and after its use for fractionation of an intact protein such as ferritin.  相似文献   

6.
A multiplexed hollow fiber flow field-flow fractionation (MxHF5) is introduced to increase throughput of an HF5 channel system for semi-preparative purposes. HF5, a cylindrical version of the flow field-flow fractionation (FlFFF) operated with a porous, hollow fiber membrane by controlling the ratio of radial and axial flow rates, is capable of fractionating proteins, cells, and macromolecules by size. An advantage of HF5 is its inexpensive channel construction, allowing for disposability that can reduce run-to-run carryover problems. MxHF5 constructed in this study was made with six parallel HF5 modules connected to seven-port manifolds for the semi-preparative scale separation of proteins or biological particles. For the evaluation of MxHF5 separation efficiency, protein standards were utilized to test peak recoveries, band broadening, and throughput. The assembly showed the possibility of handling up to 50 μg of proteins without incurring overloading. The developed channel was applied to demonstrate size sorting of lipoproteins for the future study of size dependent lipidomic and proteomic analysis. The current trial offers a unique advantage of scaling up HF5 separation without using wide-bore, hollow fibers which sacrifice separation speed.  相似文献   

7.
Hollow-fiber flow field-flow fractionation (HF FlFFF) was applied for the separation and size characterization of airborne particles which were collected in a municipal area and prefractionated into four different-diameter intervals >5.0, 2.5-5.0, 1.5-2.5, <1.5 microm) by continuous split-flow thin (SPLIIT) fractionation. Experiments demonstrated the possibility of utilizing a hollow-fiber module for the high-performance separation of supramicron-sized airborne particles at steric/hyperlayer operating mode of HF FlFFF. Eluting particles during HF FlFFF separation were collected at short time intervals (approximately 10 s) for the microscopic examination. It showed that particle size and size distributions of all SPLITT fractions of airborne particles can be readily obtained using a calibration and that HF FlFFF can be utilized for the size confirmation of the sorted particle fraction during SPLITT fractionation.  相似文献   

8.
Membraneless hyperlayer flow field-flow fractionation (Hyp FIFFF) has shown improved performance with respect to Hyp FIFFF with membrane. The conditions for high recovery and recovery independent of sample loading in membraneless Hyp FIFFF have been previously determined. The effect of sample loading should be also investigated in order to optimize the form of the peaks for real samples. The effect of sample loading on peak retention parameters is of prime importance in applications such as the conversion of peaks into particle size distributions. In this paper, a systematic experimental work is performed in order to study the effect of sample loading on retention parameters. A procedure to regenerate the frit operating as accumulation wall is described. High reproducibility is obtained with low system conditioning time.  相似文献   

9.
Reinjection of one ore more collected fractions of eluted samples is recognized as a useful procedure in analytical separation techniques, among which field-flow fractionation (FFF), to improve the actual separation of complex samples. Hollow-fiber flow FFF (HF5) is a micro-channel subset of flow FFF (F4), which has recently reached a performance comparable to that of standard, flat-channel F4. To further improve HF5 of complex protein samples, we present a new device and method for in-line, reinjection HF5 that we call tandem HF5 (HF5/HF5). HF5 is ideally suited for tandem operation because (1) small channel volume and low operation flow rates allow reducing dilution and volume of the collected fractions, and (2) the relaxation/focusing step that takes place between the 1st and 2nd run (refocusing) allows reestablishing the volume and concentration of the sample plug before the 2nd elution. HF5/HF5 proves particularly effective in the case of oligomeric proteins since it allows collecting and reinjecting the bands that correspond to each separated oligomeric form. This provides information on the dynamic equilibria between the different oligomers. For HF5/HF5 operations, a modified, prototype HF5 instrumentation is presented which includes a "trap" constituted of a four-port, two-way valve positioned downstream the UV detector and a collection loop. The effect of refocusing conditions on HF5/HF5 performance is investigated by varying refocusing time. With a complex protein samples such as blood serum, HF5/HF5 can improve detectability of the low abundance components since overloading effects due to high-abundance components are reduced. This is shown for serum lipoproteins: while after the 1st run high density lipoproteins (HDLs) are not separated from high-abundance serum proteins, after the 2nd run it is shown possible to separate the HDL subclasses.  相似文献   

10.
In this article, a simple experimental approach to improve lipoprotein separation and detection in flow field-flow fractionation (FlFFF) is detailed. Lipoproteins are globular particles composed of lipids and proteins in blood serum and their roles include transferring fats and cholesterols through blood vessels throughout the body. Especially, presence of small, dense low-density lipoproteins (LDL) is associated with cardiovascular risk. Two experimental approaches were explored in this study: an increase in the reproducibility of LDL particle separation by implementing a guard channel prior to an asymmetrical FlFFF (AFlFFF) channel in order to deplete small molecular weight serum proteins and reducing the required injection volume of a serum sample by implementing fluorescence detection. The guard channel was made of a simple hollow fiber module so that the serum sample can be washed with the help of radial flow prior to injection into the AFlFFF channel. The channel was tested with protein standards and serum samples to ensure precision of the retention time and the protein recovery rate. A fluorescent phospholipid dye was utilized to label lipoprotein particles before separation for fluorescence detection, which resulted in a reduction of the required injection volume of serum.  相似文献   

11.
The separation efficiencies of three different asymmetrical flow field-flow fractionation (AF4) channel designs were evaluated using polystyrene latex standards. Channel breadth was held constant for one channel (rectangular profile), and was reduced either linearly (trapezoidal profile) or exponentially (exponential profile) along the length for the other two. The effective void volumes of the three channel types were designed to be equivalent. Theoretically, under certain flow conditions, the mean channel flow velocity of the exponential channel could be arranged to remain constant along the channel length, thereby improving separation in AF4. Particle separation obtained with the exponential channel was compared with particle separation obtained with the trapezoidal and rectangular channels. We demonstrated that at a certain flow rate condition (outflow/inflow rate = 0.2), the exponential channel design indeed provided better performance with respect to the separation of polystyrene nanoparticles in terms of reducing band broadening. While the trapezoidal channel exhibited a little poorer performance than the exponential, the strongly decreasing mean flow velocity in the rectangular channel resulted in serious band broadening, a delay in retention time, and even failure of larger particles to elute.  相似文献   

12.
Kim KH  Lee JY  Moon MH 《The Analyst》2011,136(2):388-392
Effects of protein denaturation and formation of protein-sodium dodecyl sulfate (SDS) complexes on protein separation and identification were investigated using hollow fiber flow field-flow fractionation (HF5) and nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Denaturation and formation of protein-SDS complexes prior to HF5 separation resulted an increase in the retention of few protein standards due to unfolding of the protein structures and complexation, yielding ~30% increase in hydrodynamic diameter. In addition, low molecular weight proteins which could be lost from the HF membrane due to the pore size limitation showed an increase of peak recovery about 2-6 folds for cytochrome C and carbonic anhydrase. In the case of proteins composed of a number of subunits, denaturation resulted in a decrease in retention due to dissociation of protein subunits. A serum proteome sample, denatured with dithiothreitol and SDS, was fractionated by HF5, and the eluting protein fractions after tryptic digestion were analyzed for protein identification using nLC-ESI-MS-MS. The resulting pools of identified proteins were found to depend on whether the serum sample was treated with or without denaturation prior to the HF5 run due to differences in the aqueous solubility of the proteins. The enhancement of protein solubility by SDS also increased the number of identified membrane proteins (54 vs. 31).  相似文献   

13.
Asymmetrical flow field-flow fractionation (AF4) and hollow-fiber flow field-flow fractionation (HF5) are techniques widely used in analytical, industrial and biological analyses. The main problem in all AF4 and HF5 analyses is sample loss due to analyte–membrane interactions. In this work the impact of liquid carrier composition on latex nanoparticles (NPs) separation in water and two different concentrations of NH4NO3 was studied. In AF4, a constant trend of decreasing the size of 60 and 121.9 nm particles induced by the ionic strength of the carrier liquid has been observed. In contrast, an agglomeration effect of the biggest 356 nm particles was observed when increasing ionic strength, which induced a significant drop of recovery to 35%. H5F provides better resolution and intensified peaks of NPs, but careful optimisation of system parameters is mandatory to obtain good separation.  相似文献   

14.
Hollow fiber flow FFF (HF FlFFF) has recently shown its capability to separate and characterize the size of submicrometer particles and has demonstrated the potential to be developed into a disposable flow FFF channel. In this work, HF FlFFF was used for the hyperlayer separation of micron-sized particles and the separation capability was examined by using various hollow fiber membrane materials (Polysulfones, cPVC, and PAN). From the experiments, PAN (polyacrylonitriles) showed an outstanding performance in particle separation compared to the other membranes. By orienting the fiber module in an upright direction, the upstream flow migration reduced band broadening of eluted peaks. When the efficiency of the PAN hollow fiber system was tested by varying the ratio of outflow-rate to radial flow-rate, it was found that optimum separation in hyperlayer HF FlFFF can be obtained at the ratio of about 6–7. From the examination of retention at or around steric inversion diameter, it was observed that experiments showed a good agreement with predictions by semi-empirical calculation. In hyperlayer HF FlFFF the diameter based selectivity values were shown to be 1.2–1.7 depending on the type of membranes and the field strength (the radial flow-rate) conditions.  相似文献   

15.
Continuous flow electrophoretic separation with continuous sample loading provides the advantage of processing volumes of any sizes, as well as the benefit of a real-time monitoring and optimization of the separation process. In addition, the spatial separation of the sample enables collecting multiple separated components simultaneously and in a continuous manner. The separation is usually performed in mild buffers without organic solvents and detergents (sample biological activity is retained) and it is carried out without usage of a solid support in the separation space preventing the interaction of the sample with it (high sample recovery). The method is used for the separation of proteins/peptides in proteomic applications, and its great applicability is to the separation of the cells, cellular organelles, vesicles, membrane fragments, and DNA. This review focuses on the electrophoretic separation performed in a continuous flow and it describes various electrophoretic modes and instrumental setups. Recent developments in methodology and instrumentation, the integration with other techniques, and the application to the biological sample analysis are discussed as well.  相似文献   

16.
Asymmetrical flow field-flow fractionation (AFlFFF) has been carried out in a miniaturized channel by reducing the channel dimensions. Performance of the miniaturized AFlFFF (mAFlFFF) channel was evaluated with standard proteins and polystyrene latex spheres from nanometer to micrometer size. By reducing the channel dimension, proteins or particulate materials can be separated within a few minutes without a significant loss in resolution. The mAFlFFF channel was applied for the separation of exosomes harvested from immortalized human mesenchymal stem cell line. It shows a potential to fractionate exosome vesicles according to sizes which can be useful for proteomic studies in relation to immunotherapeutic applications.  相似文献   

17.
A novel, simple, and economic method, hollow-fiber ultrafiltration followed by centrifugation, has been developed for separation of viscid substances with similar properties except for different molecular weight. The experimental assembly needed only a U-shaped hollow fiber containing the sample solution with both ends of the fiber connected to two syringe needles. Ultrafiltration was performed by the action of centrifugal force. Concentration polarization was overcome and no phase transition occurred. Satisfactory recovery was achieved.  相似文献   

18.
Qi LY  Yin XF  Zhang L  Wang M 《Lab on a chip》2008,8(7):1137-1144
A rapid and variable-volume sample loading scheme for chip-based sieving electrophoresis was developed by negative pressure combined with electrokinetic force. This was achieved by using a low-cost microvacuum pump and a single potential supply at a constant voltage. Both 12% linear polyacrylamide (LPA) with a high viscosity of 15000 cP and 2% hydroxyethylcellulose (HEC) with a low viscosity of 102 cP were chosen as the sieving materials to study the behavior and the versatility of the proposed method. To reduce the hydrodynamic resistance in the sampling channel, sieving material was only filled in the separation channel between the buffer waste reservoir (BW) to the edge of the crossed intersection. By applying a subambient pressure to the headspace of sample waste reservoir (SW), sample and buffer solution were drawn immediately from sample reservoir (S) and buffer reservoir (B) across the intersection to SW. At the same time, the charged sample in the sample flow was driven across the interface between the sample flow and the sieving matrix into the sieving material filled separation channel by the applied electric field. The injected sample plug length is in proportion with the loading time. Once the vacuum in SW reservoir was released to activate electrophoretic separation, flows from S and B to SW were immediately terminated by the back flow induced by the difference of the liquid levels in the reservoirs to prevent sample leakage during the separation stage. The sample consumption was about 1.7 x 10(2) nL at a loading time of 1 s for each cycle. Only 0.024 s was required to transport bias-free analyte to the injection point. It is easy to freely choose the sample plug volume in this method by simply changing the loading time and to inject high quality sample plug with non-distorted shape into the separation channel. The system has been proved to possess an exciting potential for improving throughput, repeatability, sensitivity and separation performance of chip-based sieving electrophoresis.  相似文献   

19.
Flux can vary along the fiber length in submerged hollow-fiber membranes depending upon the axial gradients of both pressure and foulant layer build-up. However, the measurement of flux is necessarily length-averaged because it is determined by the flow rate exiting the end of the fiber. The length-averaged flux below which no foulant accumulates in a specified filtration time is defined as the critical flux. Critical flux is shown in this work to be a relative rather than absolute value. It depends on the fiber length, observation time, aeration rate and the compressibility of the particles. Fouling will occur in full-scale if the critical flux test is established in tests with fibers that are much shorter than in full-scale and/or with a filtration time that is shorter than in full-scale.  相似文献   

20.
Nagata H  Tabuchi M  Hirano K  Baba Y 《Electrophoresis》2005,26(11):2247-2253
Separation of sodium dodecyl sulfate (SDS)-protein complexes is difficult on plastic microchips due to protein adsorption onto the wall. In this paper, we elucidated the reasons for the difficulties in separating SDS-protein complexes on plastic microchips, and we then demonstrated an effective method for separating proteins using polymethyl methacrylate (PMMA) microchips. Separation difficulties were found to be dependent on adsorption of SDS onto the hydrophobic surface of the channel, by which cathodic electroosmotic flow (EOF; reversed flow) was generated. Our developed method effectively utilized the reversed flow from this cathodic EOF as a driving force for sample proteins using permanently uncoated but dynamic SDS-coated PMMA microchips. High-speed (6 s) separation of proteins and peptides up to 116 kDa was successfully achieved using this system.  相似文献   