首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
Both fluoxetine (FLX) and its N-demethylated metabolite, norfluoxetine (NFLX), have been reported to be potent serotonin-reuptake inhibitors. A sensitive and reliable method that allows simultaneous quantification of their plasma levels would be valuable and was developed in this work. The procedure included extraction of FLX and NFLX from plasma, fluorescence derivatization with 4-(N-chloroformylmethyl-N-methyl) amino-7-nitro-2,1,3-benzoxadiazole (NBD-COCl), separation of the derivatives on an octadecylsilica column with acetonitrile-water (55:45,v/v) as mobile phase and fluorescence detection with emission at 537 nm and excitation at 478 nm. The calibration curves were linear for FLX and NFLX concentration over the range of 10-1000 nM (r = 0.9992 and r = 0.9997) and the limits of quantitation were 10 nM in 100 micro L of plasma. Precision of intra- and inter-day RSD of less than 12% and accuracy of intra- and inter-day RE within -6.0-13% were achieved. The method described was applied to analysis of the plasma samples from rats treated with FLX hydrochloride and to the pharmacokinetic study.  相似文献   

2.
Yi L  Zhao H  Chen S  Jin L  Zheng D  Wu Z 《Talanta》2003,61(3):403-409
A simple, rapid and sensitive method for the determination of two fluoquinolones (FQs), enoxacin (ENX) and ofloxacin (OFLX) is described by using flow injection analysis with potassium permanganate-sodium sulfite chemiluminescence detection. The calibration graphs for ENX and OFLX are linear in the range of 8.0×10−10-1.0×10−5 and 1.0×10−9-1.0×10−6 mol l−1, respectively. The 3σ limits of detection are 2.4×10−10 mol l−1 for ENX and 5.6×10−10 mol l−1 for OFLX. The method is applied satisfactorily to the determination of the two FQs in dosage form and urine sample. The possible mechanism is also proposed.  相似文献   

3.
Wei S  Lin J  Li H  Lin JM 《Journal of chromatography. A》2007,1163(1-2):333-336
A simple, reliable microemulsion electrokinetic chromatography (MEEKC) method is developed for the simultaneous separation of seven fluoroquinolones (FQs). The best separation is achieved in a carrier electrolyte containing 1% (v/v) heptane, 100 mmol/L sodium dodecyl sulfate (SDS), 10% (v/v) 1-butanol, and 8 mmol/L phosphate-sodium tetraborate buffer at pH 7.30. The proposed method was directly applied to the determination of ciprofloxacin (CPF) and lomefloxacin (LMF) in urine samples of subjects administered either with CPF or LMF.  相似文献   

4.
胡娟  闻京伟 《应用化学》2001,18(12):1009-0
喹诺酮类药物属于人工合成抗生素 ,至今已开发或正在开发的约 5 0多种 ,成为抗感染药物中最活跃的研究领域之一 ,是一类有巨大潜力的新型抗菌药 .喹诺酮类药物的测定 ,大多采用高效液相色谱法 [1~ 3 ] .但高效液相色谱仪的价格昂贵 ,测定对样品的处理要求较高 ,应用受到限制 .示波分析法具有仪器简单、操作简便、选择性高等优点 ,用此法测定吡哌酸、诺氟沙星含量已有报道 [4~ 6] .本文进一步研究了依诺沙星 (ENX)、环丙沙星(CPLX)、氧氟沙星 (OFLX)、氟罗沙星 (FLRX)和司帕沙星 (SPLX)等 5种喹诺酮类药物的示波测定条件及方法 .S…  相似文献   

5.
The electrochemiluminescence (ECL) of Tb3+-enoxacin-Na2SO3 system (ENX system) and Tb3+-ofloxacin-Na2SO3 system (OFLX system) in aqueous solution is reported. ECL is generated by the oxidation of Na2SO3, which is enhanced by Tb3+-fluoroquinolone (FQ) complex. The ECL intensity peak versus potential corresponds to oxidation of Na2SO3, and the ECL emission spectra (the peaks are at 490, 545, 585 and 620 nm) match the characteristic emission spectrum of Tb3+, indicating that the emission is from the excited state of Tb3+. The mechanism of ECL is proposed and the difference of ECL intensity between ENX system and OFLX system is explained. Conditions for ECL emission were optimized. The linear range of ECL intensity versus concentrations of pharmaceuticals is 2.0 x 10(-10) -8.0 x 10(-7)mol l(-1) for ENX and 6.0 x 10(-10) -6.0 x 10(-7)mol l(-1) for OFLX, respectively. A theoretical limit of detection is 5.4 x 10(-11)mol l(-1) for ENX and 1.6 x 10(-10)mol l(-1) for OFLX, respectively. The ECL was satisfactorily applied to the determination of the two FQs in dosage form and urine sample.  相似文献   

6.
《Analytical letters》2012,45(3):603-617
Abstract

In this paper we report on the low temperature phosphorescence (LTP), the low temperature fluorescence (LTF), the paper substrate room temperature phosphorescence (PS‐RTP), and the room fluorescence (RTF) properties of ciprofloxacin (CPFX), lomefloxacin (LMX), fleroxacin (FLX), and ofloxacin (OFLX), which were investigated and compared. Some rules were discovered: their maximal excitation wavelength and emission wavelength are in the range of 280–295 nm and 428–500 nm, respectively, except OFLX, and the difference in molecular structure may be responsible for it. The pH experiments show that all their emissions are strongest in acid, followed by neutral, and weakest in alkali medium. The PS‐RTP characters of lifetime and polarization were also investigated and compared. It was found that the lifetimes of PS‐RTP were all in the level of 0.1 s. These quinolones belong to long‐life phosphorescence and their PS‐RTP spectra are incompletely polarized.  相似文献   

7.
解娜  丁晓静  宋宝花  李佳  王志 《色谱》2013,31(1):64-70
建立了邻苯二甲醛(OPA)、对氯间二甲基苯酚(PCMX)和三氯生3种杀菌剂同时分离测定的胶束电动毛细管色谱(MEKC)新方法。详细研究了影响上述3种杀菌剂同时分离与准确定量的因素: 如分离缓冲溶液的浓度及pH,十二烷基硫酸钠(SDS)浓度、样品缓冲溶液等。以40.2 cm (有效长度: 30 cm)×50 μm未涂层熔融石英毛细管为分离柱,20 mmol/L硼砂-80 mmol/L SDS(无需调pH)为分离缓冲溶液,2 mmol/L硼砂-8 mmol/L SDS (含体积分数为10%甲醇)为样品缓冲溶液,检测波长为214 nm。3种杀菌剂的校正峰面积的相对标准偏差(RSD)在1.1%~ 3.8%范围内,迁移时间的RSD均小于0.9%, OPA、PCMX和三氯生的检出限(LOD,信噪比为3)分别为4.0、0.4、0.4 mg/L,定量限(LOQ,信噪比为10)分别为12、1.2、1.2 mg/L,校正峰面积与相应的质量浓度分别在12~2 000 mg/L、1.2~200 mg/L和1.2~200 mg/L范围内具有良好的线性关系,相关系数分别为0.9994、0.9993和0.9995。该法前处理简单,可快速、准确地同时测定3种组分,非常适合常规实验室分析。  相似文献   

8.
Lanthanide sensitized luminescence and chemiluminescence (CL) are of great importance because of the unique spectral properties, such as long lifetime, large Stokes shifts, and narrow emission bands characteristic to lanthanide ions (Ln3+). With the fluoroquinolone (FQ) compounds including enoxacin (ENX), norfloxacin (NFLX), lomefloxacin (LMFX), fleroxacin (FLRX), ofloxacin (OFLX), rufloxacin (RFX), gatifloxacin (GFLX) and sparfloxacin (SPFX), the luminescence and CL properties of Tb3+–FQ and Eu3+–FQ complexes have been investigated in this contribution. Ce4+–SO32− in acidic conditions was taken as the CL system and sensitized CL intensities of Tb3+–FQ and Eu3+–FQ complexes were determined by flow-injection analysis. The luminescence and CL spectra of Tb3+–FQ complexes show characteristic peaks of Tb3+ at 490 nm, 545 nm, 585 nm and 620 nm. Complexes of Tb3+–ENX, Tb3+–NFLX, Tb3+–LMFX and Tb3+–FLRX display relatively strong emission intensity compared with Tb3+–OFLX, Tb3+–RFX, Tb3+–GFLX and Tb3+–SPFX. Quite weak peaks with unique characters of Eu3+ at 590 nm and 617 nm appear in the luminescence and CL spectra of Eu3+–ENX, but no notable sensitized luminescence and CL of Eu3+ could be observed when Eu3+ is added into other FQ. The distinct differences on emission intensity of Tb3+–FQ and Eu3+–FQ might originate from the different energy gap between the triplet levels of FQ and the excited levels of the Ln3+. The different sensitized luminescence and CL signals among Tb3+–FQ complexes could be attributed to different optical properties and substituents of these FQ compounds. The detailed mechanism involved in the luminescence and CL properties of Tb3+–FQ and Eu3+–FQ complexes has been investigated by analyzing the luminescence and CL spectra, quantum yields, and theoretical calculation results.  相似文献   

9.
采用毛细管电泳安培法建立了肉苁蓉中松果菊苷含量的检测方法,探讨了缓冲溶液种类、工作电位、分离电压、进样时间等对分离和检测的影响.在15 mmol/L硼砂缓冲溶液(pH 9.5),25 kV电压,0.6 V工作电位的条件下,松果菊苷的质量浓度在0.5~50.0 mg/L范围内与峰面积呈良好线性,相关系数为0.9994,检...  相似文献   

10.
Fluoxetine (FLX) and the N-desmethyl metabolite, norfluoxetine (NFLX) in rat brain microdialysis samples were determined by high-performance liquid chromatography (HPLC) with fluorescence detection using pre-column derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). In vitro experiment showed that the relative recovery of FLX across microdialysis membrane was enhanced by adding β-cyclodextrin (β-CD) or β-CD polymer to microdialysis perfusion fluid. The perfusion fluid containing β-CD polymer, which has polymeric glyceryl linkers attached to the hydroxyl group, gave the better recovery with satisfactory precisions. Using 1% β-CD polymer in Ringer’s solution as the perfusate, in vivo rat brain microdialysis experiment on intraperitoneal administration of FLX (10 mg/kg) to rats was carried out. The fluorescence peaks of FLX and NFLX appeared later than 30 min after the administration of FLX, and then, gradually increased with time. Two hours later, FLX reached a plateau level, but NFLX slowly increased, and at 24-48 h, NFLX levels were higher than FLX levels. These data suggest that long distributions of FLX and the potent metabolite, NFLX, in brain contributed to the long-term drug actions in vivo.  相似文献   

11.
徐远金  许桂苹  魏远安 《色谱》2006,24(1):35-38
建立了一种利用胶束电动毛细管色谱-间接紫外检测法同时测定丙二酸、甲酸、酒石酸、苹果酸、琥珀酸、戊二酸、乙酸、乳酸和谷氨酸的新方法。以7.5 mmol/L邻苯二甲酸氢钾-1.5 mmol/L十六烷基三甲基溴化铵(用0.1 mol/L氢氧化钠调pH至6.50)混合液作为电泳介质,检测波长为300 nm,参比波长为210 nm,未涂层弹性石英毛细管(50 μm i.d.×64 cm)为分离通道,在6 min内实现了9种酸的完全分离。9种有机酸的浓度与其峰面积在一定的范围呈良好的线性关系,检出限均低于1.5 mg/L,迁移时间和峰面积的日内、日间相对标准偏差均小于6%。该法用于糖蜜酒精废液中有机酸的测定,结果令人满意,9种有机酸的样品加标回收率均在93%以上。  相似文献   

12.
The aim of this work was to develop a fast method using capillary electrophoresis for the determination of creatinine in human urine samples. The pH and constituents of the background electrolyte were selected by inspection of effective mobility of creatinine and candidate urine interferents versus pH curves. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated by the Peakmaster software and considered in the optimization of the background electrolyte, composed by 10 mmol L(-1) tris(hydroxymethyl)aminomethane and 20 mmol L(-1) 2-hydroxyisobutyric acid (HIBA) at pH 3.93. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 microm I.D.), with short-end injection configuration and direct UV detection at 215 nm. The migration time of creatinine was only 22s. A few figures of merit of the method are as follows: good linearity in the concentration interval of 5-70 mg L(-1) (R(2)>0.99), limit of detection of 0.5 mg L(-1), inter-day precision better than 2.7% (n=9) and recovery in the range 99.0-103.7% at three concentration levels (50, 100 and 150 mg L(-1)). Urine samples were prepared by deproteination with acetonitrile (1:3 sample:acetonitrile, v/v), centrifugation and dilution of a deproteinated aliquot with 12.5 mmol L(-1) HIBA (1:4, v/v). Creatinine concentrations between 489 and 1063 mg L(-1) were obtained in the urine of four healthy volunteers.  相似文献   

13.
欧婉露  李玉娟  石冬冬  屈锋 《色谱》2015,33(2):152-157
藤黄酸(gambogic acid, GA)等环氧杂蒽酮类化合物的水溶性差,可通过非水毛细管电泳(non-aqueous capillary electrophoresis, NACE)分析。本文系统地考察了添加20%~60%(v/v)的甲醇或乙腈的运行电解质溶液对藤黄提取液中藤黄酸分离的影响。比较了不同的运行电解质溶液、运行电解质溶液浓度、pH、添加剂 β-环糊精的浓度、分离温度及分离电压的影响,建立了测定藤黄药材中藤黄酸含量的非水毛细管电泳方法。在40%乙腈、10 mmol/L β-环糊精、20 mmol/L四硼酸钠(pH 9.86)为运行电解质溶液、分离电压为10 kV、分离温度为30 ℃、检测波长为280 nm的条件下进行测定。结果表明,藤黄酸在2~2000 mg/L范围内线性关系良好,相关系数为0.9996,检出限(S/N=3)为2 mg/L。将本方法应用于越南、泰国、缅甸、印度4个产地的藤黄药材中藤黄酸的含量测定,测得含量为1.67~472.40 mg/g(相对标准偏差(RSD)为1.12%~2.60%),其中越南产藤黄中藤黄酸含量低,其他产地藤黄中藤黄酸的含量高。实际藤黄样品中藤黄酸的加标回收率为95.2%~105.6%。非水毛细管电泳方法简单、快速、重现性好,可用于藤黄药材中藤黄酸的含量测定。  相似文献   

14.
An efficient micellar electrokinetic capillary chromatography method was developed to analyze three major active components including morroniside, loganin and gallic acid in Fructus corni and its six preparations for the first time. The factors that could affect the separation were studied, such as the pH of the buffer, concentrations of SDS, organic modifier and beta-CD, and the applied voltage. The optimum analysis conditions were 10 mmol/L NaH(2)PO(4)-5 mmol/L Na(2)B(4)O(7) (pH 6.8) buffer containing 140 mmol/L SDS, 1 mmol/L beta-CD, 5% (v/v) methanol and 12.5 kV applied voltage. The linearity between the peak-areas and the concentrations of the analytes were investigated, and they exhibit excellent linear behavior over the concentration ranges (correlation coefficients 0.9953-0.9995). In addition, the pK(a) of gallic acid was determined using capillary zone electrophoresis. The result was consistent with that reported by the literature.  相似文献   

15.
Liu S  Xie Z  Wu X  Lin X  Guo L  Chen G 《Journal of chromatography. A》2005,1092(2):258-262
In this paper, the pressurized capillary electrochromatography (pCEC) with UV detection was utilized for the separation and determination of three structurally related estrogens, such as diethylstilbestrol (DES), hexestrol (HEX) and dienestrol (DE), which were difficult to be separated by capillary electrophoresis (CE) and HPLC due to their similarity in the structure and charge-to-mass ratios. Experiments were carried out in a commercially available pCEC instrument using a capillary column packed with 3 microm octadecyl silica (ODS). Surfactant sodium dodecyl sulfate (SDS) was introduced in the mobile phase to enhance the speed of analysis. The effective factors on the retention time and separation resolution, such as the applied voltage, supplementary pressure, the pH and the concentration of the buffer solution, the concentration of SDS, and the content of acetonitrile in the mobile phase, were evaluated. Based on the investigation, 31% (v/v) acetonitrile and 69% (v/v) of 10 mmol/L phosphate buffer (pH 6.5) containing 1.0 mmol/L SDS at an applied voltage of -12 kV and a supplementary pressure of 1000 psi were found to be the optimal conditions for pCEC to separate the three estrogens. The method also had been applied to the analysis of fish muscle samples spiked with estrogens.  相似文献   

16.
毛细管电泳-间接紫外检测法测定蜂蜜中的氨基酸   总被引:2,自引:0,他引:2  
周贤婧  师彦平 《色谱》2013,31(7):661-666
采用毛细管电泳-间接紫外检测法同时分离测定蜂蜜中的赖氨酸、色氨酸、谷氨酸等9种氨基酸。考察了磷酸浓度、进样方式和缓冲液pH对分离效率和重现性的影响。在分离电压为-15 kV、检测波长为220 nm条件下,以含有0.5 mmol/L十六烷基三甲基溴化铵、20 mmol/L烟酸、10%甲醇的10 mmol/L磷酸二氢钠缓冲溶液(pH 10.2)为运行缓冲液,9种组分在11 min内达到基线分离;检出限最低可达到0.3 mg/L;线性范围为1.0~1000 mg/L;日间及日内精密度为0.64%~5.83%。实际样品中除甲硫氨酸外的8种氨基酸的加标回收率为60.00%~118.37%。将该方法应用于不同蜜源植物和产地的蜂蜜样品的测定,在市售的5种蜂蜜中均检测到脯氨酸、丝氨酸和天冬氨酸,而只在荔枝蜜中检测到苏氨酸。该方法可以为蜂蜜的蜜源鉴别及质量评估提供借鉴方法。  相似文献   

17.
A complete analytical procedure, including sample clean-up and a micellar electrokinetic chromatographic method, is presented for the determination of sulfamethoxazole, trimethoprim, and their main metabolites by using 20 mmol L(-1) borate buffer (pH 9.3), 25 mmol L(-1) sodium dodecylsulfate, and 5% v/v acetonitrile as electrolyte. The separation was carried out at 30 kV and 20 degrees C in a fused silica capillary (60.2 cm x 75 microm inner diameter) fitted with a window in the capillary cartridge of 100 x 800 microm. The detector response was linear from the limit of quantification to 3 mg L(-1) for the individual components. The limits of quantification ranged from 0.13 up to 0.24 mg L(-1). The method was applied to human serum, previously spiked at different concentrations of all the analytes, and recoveries between 95% and 108% were obtained.  相似文献   

18.
建立了毛细管胶束电动色谱法同时测定中药复方制剂连花清瘟胶囊中甘草苷、芦丁、金丝桃苷、槲皮苷、绿原酸、大黄酸6种药效成分含量的分析方法.使用未涂层弹性石英毛细管,以50 mmol/L SDS-15mmol/L磷酸氢二钠-15 mmol/L硼酸(含25%异丙醇,pH=8.0)作电解质,于254 nm下紫外检测,被测组分在3...  相似文献   

19.
This paper reports the determination of ulifloxacin (UFX) by terbium-sensitized fluorescence using a second-order scattering method. UFX and Tb(III) ion form a fluorescence complex in aqueous solution, and its maximum excitation and emission wavelengths are located at 273 and 545 nm, respectively. In optimum conditions, the relative intensity at 545 nm has a linear relationship to the concentration of UFX in the range of 2.0 x 10(-8) - 1.0 x 10(-5) mol L(-1) and the detection limit is 3.9 x 10(-9) mol L(-1). The proposed method was applied to the determination of UFX in spiked human serum and urine satisfactorily. The luminescence property of UFX is also discussed by comparing with norfloxacin (NFLX) and ofloxacin (OFLX).  相似文献   

20.
环丙沙星-锰络合吸附波的研究①张加玲樊惠芝潘景浩*(山西大学化学系,太原030006)环丙沙星(ciprofloxacin简写CPFX)是新一代氟喹诺酮类抗菌药物之一,它的抗菌力强、抗菌谱宽,临床应用非常广泛.关于氟喹诺酮类抗菌药物与抗酸剂、维生素类...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号