首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sequential arsenic extraction method was developed that yielded extraction efficiencies (EE) that were approximately double those using current methods for terrestrial plants. The method was applied to plants from two arsenic contaminated sites and showed potential for risk assessment studies. In the method, plants were extracted first by 1:1 water-methanol followed by 0.1 M hydrochloric (HCl) acid. Total arsenic in plant and soil samples collected from contaminated sites was mineralized by acid digestion and detected by inductively coupled plasma-atomic emission spectrometry (ICP-AES) and hydride generation-atomic absorption spectrometry (HG-AAS). Arsenic speciation was done by high performance liquid chromatography coupled with HG-AAS (HPLC-HGAAS) and by HPLC coupled with ICP-mass spectrometry (HPLC-ICP-MS). Spike recovery experiments with arsenite (As(III)), arsenate (As(V)), methylarsonic acid (MA) and dimethylarsinic acid (DMA) showed stability of the species in the extraction processes. Speciation analysis by X-ray absorption near edge spectroscopy (XANES) demonstrated that no transformation of As(III) and As(V) occurred due to sample handling. Dilute HCl was efficient in extracting arsenic from plants; however, extraction and determination of organic species were difficult in this medium. Sequential extraction with 1:1 water-methanol followed by 0.1 M-HCl was most useful in extracting and speciating both organic and inorganic arsenic from plants. Trace amounts of MA and DMA in plants could be detected by HPLC-HGAAS aided by the process of separation and preconcentration of the sequential extraction method. Both organic and inorganic arsenic compounds could be detected simultaneously in synthetic gastric fluid extracts (GFE) but EEs by this method were lower than those of the sequential method. The developed sequential method was shown to be reliable and applicable to various terrestrial plants for arsenic extraction and speciation.  相似文献   

2.

A method is presented for arsenic speciation analysis of an oyster sample using ion chromatography coupled with an inductively coupled plasma mass spectrometry (ICP-MS) instrument. A strong anion exchange resin was employed with a step gradient elution of 0.1 mM/0.1 M K 2 SO 4 at pH 10.2. Arsenobetaine and dimethylarsinic acid were determined following extraction based on trypsin enzymolysis with 95-100% extraction efficiency. Limits of detection in the range 0.1-0.3 mg kg m 1 of arsenic were obtained for organic arsenic species. No inorganic arsenic was detected. Validation was performed using TORT-2 as a certified reference material. Although high performance liquid chromatography (HPLC) coupled to ICP-MS is an effective method for speciation analysis it is not always necessary to obtain such a detailed picture. A simple liquid chromatographic separation technique based upon mini-column technology is presented. It was developed to obtain a fast, efficient and reliable separation of inorganic from organic, i.e. assumed toxic from non-toxic, arsenic and selenium species suitable for use as an initial screening method for environmental analysis. Two types of strong anion exchange resin were tested. Excellent separation was obtained for both min-column resins and analysis times were within 7 min. Limits of detection obtained for inorganic arsenic, organic arsenic, selenomethionine, Se IV and Se VI were 1.6, 1.8, 66, 32 and 22 µg kg m 1 , respectively.  相似文献   

3.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

4.
《Analytical letters》2012,45(10):1573-1586
Arsenic (As) speciation in edible seaweed has received a considerable research interest due to its impact on the food safety and human health. In this paper, we developed a simple and cost-effective methodology to extract, separate, and analyze As species in Porphyra samples collected from Jiangsu, Zhejiang, and Shandong provinces of China. Four extraction methods were compared in terms of extraction efficiency and resolution of As species. Microwave-assisted water extraction was chosen due to its short time (5 min) and high efficiency (93% of total As extracted). Total As concentration in the Porphyra samples varied within 14.0–42.1 µg g?1, determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after acid digestion. Five As species were determined by high performance liquid chromatography—ultraviolet photo-oxidation—hydride generation—atomic fluorescence spectrometry (HPLC–(UV)–HG–AFS). DMA was found only in one sample with the concentration of 0.67 µg g?1. No As(III), As(V), MMA, and AsB were detected. Taken together, the As speciation results suggest that the risk associated with As in Porphyra to human health may be negligible.  相似文献   

5.
Recently, increasing interest on the use of dispersive liquid–liquid microextraction (DLLME) developed in 2006 by Rezaee has been found in the field of separation science. DLLME is miniaturized format of liquid–liquid extraction in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In the present review, the combination of DLLME with different analytical techniques such as atomic absorption spectrometry (AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES), gas chromatography (GC), and high-performance liquid chromatography (HPLC) for preconcentration and determination of inorganic analytes in different types of samples will be discussed. Recent developments in DLLME, e.g., displacement-DLLME, the use of an auxiliary solvent for adjustment of density of extraction mixture, and the application of ionic liquid-based DLLME in determination of inorganic species even in the presence of high content of salts are presented in the present review. Finally, comparison of DLLME with the other liquid-phase microextraction approaches and limitations of this technique are provided.  相似文献   

6.
This study aimed to establish complementary high performance liquid chromatography (HPLC) methods including three modes of separation: ion pairing, cation exchange, and anion exchange chromatography, with detection by inductively coupled plasma mass spectrometry (ICPMS). The ion pairing mode enabled the separation of inorganic arsenate (As(V)), monomethylarsonic acid (MMA(V)), and dimethylarsinic acid (DMA(V)). However, the ion pair mode was unable to differentiate inorganic arsenite (As(III)) from arsenobetaine (AsB); instead, cation exchange chromatography was used to isolate and quantify AsB. Anion exchange chromatography was able to speciate all of the aforementioned arsenic species. Potential inaccurate quantification problem with urine sample containing elevated concentration of AsB, which eluted immediately after As(III) in anion exchange or ion pairing mode, was overcame by introducing a post-column hydride generation (HG) derivatization step. Incorporating HG between HPLC and ICPMS improved sensitivity and specificity by differentiating AsB from hydride-forming arsenic species. This paper emphasizes the usefulness of complementary chromatographic separations in combination with HG-ICPMS to quantitatively determine concentrations of As(III), DMA(V), MMA(V), As(V), and AsB in the sub-microgram per liter range in human urine.  相似文献   

7.
An evaluation of reversed-phase high-performance liquid chromatography (HPLC) employing mobile phases compatible with direct coupling to inductively coupled plasma-mass spectrometry (ICP-MS) is described for the selective and sensitive detection of organotin species. The findings of this study are compared with established methods, employing ion-exchange chromatography. In order to achieve optimum performance, both the HPLC and ICP-MS were optimized for speciation work. The results from studies using various mobile phases for the separation of a range of tin compounds (inorganic tin, tributyltin, dibutyltin and monobutyltin) are discussed both in terms of resolution and compatibility with ICP-MS instrumentation. Tropolone, a commonly used complexing agent for organotin species, is also discussed with reference to the chromatographic separation of tin species. Finally, the role of isotope dilution analysis in conjunction with HPLC-ICP-MS for organotin speciation is described with respect to the European Community Standards, Measurements and Testing (BCR) certified material programme.  相似文献   

8.
Summary The release of organometallic compounds and other chemical forms of elements in the environment has caused great concern because of their possible high toxicity. To validate the analytical techniques, the Community Bureau of Reference (BCR) has undertaken a series of projects for the improvement of the quality of determinations of chemical species in environmental matrices. The implementation of these projects follows a stepwise approach involving intercomparisons to detect and remove sources of errors in different phases of the analytical methods and the certification of the compounds in various matrices. The current projects deal with the determination of the extractable content of trace metals in soils (single extraction) and sediment (sequential extraction), forms of aluminium in water, elements with different oxidation states (e.g. As, Cr and Se) and organic forms (e.g. methylated forms of As in solution, methyl-mercury in fish, arseno-betaine and -choline in solutions, triethyl- and trimethyl-Pb compounds in solution, and butyltin compounds in sediment).Abbreviations AAS atomic absorption spectrometry - CVAAS cold vapour AAS - DPP differential pulse polarography - ECD electron capture detector - ETAAS electrothermal AAS - FIA flow injection analysis - FID flame ionisation detector - FLUOR spectrofluorimetry - FPD flame photometric detector - GC gas chromatography - HG hydride generation - HPLC high performance liquid chromatography - HPLC-AES HPLC atomic emission spectrometry - INAA instrumental neutron activation analysis - ICPAES Inductively coupled plasma AES - MS mass spectrometry - QFAAS quartz furnace AAS - RNAA neutron activation analysis with radiochemical separation  相似文献   

9.
Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.  相似文献   

10.
An emulsification liquid phase microextraction followed by on-line phase separation coupled to high performance liquid chromatography (HPLC) is introduced based on a novel idea for the separation of dispersed organic phase from aqueous phase. In this method, the dispersed organic extraction phase was filtered using an in-line filter and it was separated from the water sample. The new approach is simple and, in addition to improving some limitations of the conventional emulsification liquid phase microextraction, eliminates the need for centrifugation in the phase separation step.  相似文献   

11.
Yalçin S  Le XC 《Talanta》1998,47(3):787-796
Routine water analysis of arsenic species requires simple, inexpensive, rapid and sensitive methods. To this end, we have developed two methods, which are based on the use of inexpensive solid phase extraction (SPE) cartridges as low pressure chromatographic columns for separation and hydride generation atomic absorption spectrometry (HGAAS) and hydride generation atomic fluorescence spectrometry (HGAFS) for detection of arsenic. Both anion exchange and reverse phase cartridges were successfully used to separate arsenite [As(III)] and arsenate [As(V)]. The composition, concentration, and pH of eluting buffers and the effect of flow rate were systematically investigated. Speciation of inorganic As(III) and As(V) were achieved within 1.5 min, with detection limits of 0.2 and 0.4 ng/ml, respectively. Both isocratic and step gradient elution techniques were suitable for the baseline resolution of As(III) and As(V) using anion exchange cartridges. Application of the methods to the speciation of As(III) and As(V) in untreated water, tap water, and bottled water samples were demonstrated. Results from the speciation of arsenic in a standard reference material water sample using these methods were in good agreement with the certified value and with inter-laboratory comparison results obtained using HPLC separation and inductively coupled plasma mass spectrometric detection (HPLC-ICPMS).  相似文献   

12.
The solution speciation of metals is a critical parameter controlling the bioavailability, solution-solid phase distribution and transport of metals in soils. The natural metal-complexing ligands that exist in soil solution include inorganic anions, inorganic colloids, organic humic substances, amino acids (notably phytosiderophores and bacterial siderophores) and low-molecular mass organic acids. The latter two groups are of particular significance in the soil surrounding plant roots (the rhizosphere). A number of analytical methodologies, encompassing computational, spectroscopic, physico-chemical and separation techniques, have been applied to the measurement of the solution speciation of metals in the environment. However, perhaps with the exception of the determination of the free metal cation, the majority of these techniques rarely provide species specific information. High-performance liquid chromatography (HPLC) coupled to a sensitive detection system, such as inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionisation mass spectrometry (ESI-MS), offers the possibility of separating and detecting metal-organic acid complexes at the very low concentrations normally found in the soil environment. This review, therefore, critically examines the literature reporting the HPLC separation of metal-organic acid complexes with reference to thermodynamic equilibrium and kinetic considerations. The limitations of HPLC techniques (and the use of thermodynamic equilibrium calculations to validate analytical results) are discussed and the metal complex characteristics necessary for chromatographic separation are described.  相似文献   

13.
Speciation of inorganic lead (Pb2+) and several trialkyllead species (trimethyllead chloride [TML], triethyllead chloride [TEL], and triphenyllead chloride [TPhL]) is investigated using high-performance liquid chromatography (HPLC) with detection by both inductively coupled plasma emission spectroscopy (ICP-AES), and inductively coupled plasma mass spectrometry (ICP-MS). Reversed-phase, ion-pairing, and ion-exchange HPLC modes are studied. Optimal chromatographic conditions for ICP-AES detection include a reversed-phase separation utilizing a step gradient from 10 to 70% methanol. However, the gradient has been found to destabilize the plasma when using ICP-MS detection. An isocratic separation with a 30% methanol mobile phase has been found to be the best compromise between plasma stability and chromatographic resolution. Detection limits using ICP-MS detection are 3 orders of magnitude improved over ICP-AES detection.  相似文献   

14.
A study has been conducted for the separation and the determination of arsenic species in plants using high-performance liquid chromatography–hydride generation atomic fluorescence spectrometry with emphasis on sample extraction procedures. Various extraction solvents have been applied to extract arsenic species from plants in order to investigate the uptake, transfer and accumulation processes of arsenic. The method was optimized with respect to the selection of extraction solvent, extraction time and the number of extraction steps. The analytical procedure has been validated by analyzing standard reference material GBW 82301 (peach leaves) and successfully used for the arsenic speciation in plants grown on contaminated soil near an arsenic mine. Inorganic arsenic, especially arsenate (As(V)) appears to be the major component in plants and organic arsenic species of monomethylarsenic acid and dimethylarsenic acid were detected at low concentrations.  相似文献   

15.
《Analytical letters》2012,45(9):1511-1523
Anion and cation exchange high-performance liquid chromatography (HPLC) combined with inductively coupled plasma-mass spectrometry (ICP-MS) were used for speciation of selenium in supplements. All the parameters in the extraction, separation, and determination procedures were optimized. Recovery studies for the selenium species from the anion and cation exchange columns were performed and there were no analyte losses. Limits of detection for selenium(IV), selenium(VI), Se in selenomethionine, and Se in selenocystine were 0.85, 0.68, 0.84, and 0.99 nanogram per milliliter, respectively. Six brands were analyzed to identify and quantify the selenium species present, and the results found were compared with the values given on the labels. The selenium species matched the labeled species for four brands, whereas two brands were found to contain inorganic Se(VI) in contrast with the labeled claim of selenomethionine.  相似文献   

16.
Arsenic (As) is widely found in marine organisms, mainly as organic arsenical compounds. With the introduction of regulations for As species in foodstuffs and for environmental control, it has become more important to quantify the amount of arsenic species present. To address this concern new reference materials (RMs) for validation and quality assurance of As speciation measurements are being developed, including a tuna fish tissue and a robalo liver tissue. Instrumental neutron activation analysis (INAA) is used in this work as a proven analytical tool for As determinations and for validating the As mass fraction determined by liquid chromatography coupled to inductively coupled mass spectrometry (LC–ICP-MS) in extracts of the candidate RMs and other fish samples including certified RMs. Various methods for the extraction of water-soluble As species were evaluated. The best results were acquired after methanol/acetone/water extraction yielding in 93 % extractable As in the tuna RM. This procedure was used for the LC–ICP-MS studies. The results demonstrate that INAA can account for 100 % of the distribution of As species in analytical processes. It complements LC–ICP-MS for the validation of the characterization of As species in the development of RMs for such species. Excellent agreement of measured results in certified RMs with the reported values confirms the validity of the applied procedures.  相似文献   

17.
An ultraviolet-photochemical generator (UV-PVG) capable of post-column on-line transformation of both organic and inorganic mercury species to cold vapor (Hg0) with subsequent detection by quartz tube-atomic absorption spectrometry (QT-AAS) was developed. Mercury(II), methylmercury(I), ethylmercury(I), and phenylmercury(I) were successfully detected after separation by reversed-phase high-performance liquid chromatography (RP-HPLC). Two types of AAS detectors were compared. The first was a commonly used line-source instrument while the second was a high-resolution continuum source (HR-CS) AAS. The latter provided better limits of detection: 0.47?µg?L?1 for Hg(II), 0.84?µg?L?1 for methylmercury(I), 0.80?µg?L?1 for ethylmercury(I), and 2.0?µg?L?1 for phenylmercury(I). The repeatability at 30?μg?L?1 was 3.6%, 4.1%, 6.2%, and 4.5% for these species (n?=?10). These figures of merit were comparable with those reported for more sensitive atomic fluorescence spectrometry. Nine sample extraction procedures were investigated. Extraction by tetramethylammonium hydroxide and HCl at 75?°C was selected as the only method compatible with the proposed separation and detection steps providing high extraction efficiency and no changes in mercury speciation. The applicability of the proposed high-performance liquid chromatography–ultraviolet-photochemical vapor generation–quartz tube-atomic absorption spectrometry method was demonstrated using fish samples and certified reference materials (CRM) DOLT-4 (dogfish liver) and ERM-CE464 (tuna fish). The results were comparable to those obtained by a reference method based on L-cysteine extraction and high-performance liquid chromatography–inductively coupled plasma-mass spectrometry (HPLC–ICP-MS) determination.  相似文献   

18.
Enantioseparation and determination of selenomethionine enantiomers in selenized yeast was investigated using chiral separation techniques based on different principles, coupled on-line to inductively coupled plasma mass spectrometry (ICP-MS) for selenium-specific detection. High performance liquid chromatography (HPLC) on a beta-cyclodestrin (beta-CD) column, cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC), gas chromatography (GC) on a Chirasil-L-Val column, and HPLC on a Chirobiotic T column have been investigated as the chiral separation techniques. For HPLC separation on the beta-CD column, and also for CD-MEKC, selenomethionine enantiomers were derivatized with NDA/CN(-). For chiral separation by GC, selenomethionine enantiomers were converted into their N-trifluoroacetyl (TFA)-O-alkyl esters. The developed hybridation methodologies are compared with respect to enantioselectivity, sensitivity and analysis time. The usefulness of the best-suited method [HPLC (Chirobiotic T)-ICP-MS] was demonstrated by its application to the successful chiral speciation of selenium and D-and L-selenomethionine content determination in selenized yeast.  相似文献   

19.
A new method for the simultaneous separation and determination of four arsenic species [As(III), As(V), monomethylarsonic acid and dimethylarsinic acid], three selenium species [Se(IV), Se(VI) and selenomethionine] as well as Sb(III) and Sb(V) is presented. The speciation was achieved by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic parameters such as the composition and pH of the mobile phase were optimised. Limits of detection are below 4.5 μg L–1 (as element) for Sb(III) and the selenium species and below 0.5 μg L–1 for the other species. Precisions of retention times were better than 2% RSD and of peak areas better than 8% RSD for all the species investigated.  相似文献   

20.
The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号