首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
An at-line analysis protocol is presented that allows the determination of four UV filters, two polycyclic musk compounds and caffeine in water at concentration level of ng L−1. The fully automated method includes analytes enrichment by Microextraction by packed sorbent (MEPS) coupled directly to large volume injection-gas chromatography–mass spectrometry. Two common SPE phases, C8 and C18, were examined for their suitability to extract the target substances by MEPS. The analytes were extracted from small sample volumes of 800 μL with recoveries ranging from 46 to 114% for the C8-sorbent and 65–109% for the C18-sorbent. Limits of detection between 34 and 96 ng L−1 enable the determination of the analytes at common environmental concentration levels. Both sorbents showed linear calibration curves for most of the analytes up to a concentration level of 20 ng mL−1. Carryover was minimized by washing the sorbents 10 times with 100 μL methanol. After this thorough cleaning, the MEPS are re-used and up to 70 analyses can be performed with the same sorbent. The fully automated microextraction GC–MS protocol was evaluated for the influence of matrix substances typical for wastewater. Dilution of samples prior to MEPS is recommended when the polar caffeine is present at high concentration. Real water samples were analyzed by the MEPS-GC–MS method and compared to standard SPE.  相似文献   

2.
An immunoaffinity (IA) sorbent with antibody fragments was prepared for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis–mass spectrometry (IA-SPE-CE–MS). The antibody fragmentation was evaluated by MALDI-TOF-MS. Fab′ fragments obtained from a polyclonal IgG antibody against Endomorphins 1 and 2 (End1 and End2) were covalently attached to succinimidyl silica particles to prepare the IA sorbent. An IA-SPE-CE–MS methodology was established analyzing standard solutions of End1 and End2 and acceptable repeatability, linearity ranges and LODs (0.5 and 5 ng mL−1, respectively) were obtained. The LOD of End1 was slightly better than that previously obtained using an IA sorbent with intact antibodies (1 ng mL−1). In human plasma samples, End1 and End2 could be detected at 1 and 50 ng mL−1, respectively, which meant an improvement of 100 and 2-fold with regard to the LODs using an IA sorbent with intact antibodies (100 ng mL−1).  相似文献   

3.
In this work the development and validation of a new procedure for the simultaneous determination of 9 nitro and polycyclic musk compounds: musk ambrette (MA), musk ketone (MK), musk mosken (MM), celestolide (ADBI), phantolide (AHMI), tonalide (AHTN), traseolide (ATII), cashmeran (DPMI) and galaxolide (HHCB) in environmental water samples (estuarine and wastewater) using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography–mass spectrometry (LVI-GC–MS) was carried out. Apart from the optimization of the different variables affecting MEPS (i.e., nature of the sorbent, nature of the solvent elution, sample load, and elution/injection volume) extraction recovery was also evaluated, not only for water samples but also for environmental water matrices such as estuarine and waste water. The use of two deuterated analogs ([2H3]-AHTN and [2H15]-MX) was successfully evaluated in order to correct matrix effect in complex environmental matrices such as influent samples from wastewater treatment plants. Method detection limits (MDLs) ranged from 5 to 25 ng L−1, 7 to 39 ng L−1 and 8 to 84 ng L−1 for influent, effluent and estuarine samples, respectively. Apparent recoveries were higher than 75% for all target compounds in all the matrices studied (estuarine water and wastewater) and the precision of the method, calculated as relative standard deviation (RSD), was below 13.2% at 200 ng L−1 concentration level and below 14.9% at low level (20 ng L−1 for all the target analytes, except for AHTN which was set at 40 ng L−1 and HHCB at 90 ng L−1, due to the higher MDL values presented by those target compounds). Finally, this MEPS procedure was applied to the determination of the target analytes in water samples, including estuarine and wastewater, from two estuaries, Urdaibai (Spain) and Adour (France) and an established stir-bar sorptive extraction-liquid desorption/large volume injection-gas chromatography–mass spectrometry (SBSE-LD/LVI-GC–MS) method was performed in parallel for comparison. Results were in good agreement for all the analytes determined, except for DPMI.  相似文献   

4.
Hemimicelles of tetradecanoate chemisorbed onto magnetic nanoparticles (MNPs) are here proposed as a sorbent for the single-step extraction and cleanup of bisphenol A (BPA) in soft drinks. The purpose of this work was to develop a simple, rapid and low-cost sample treatment suitable to assess the human exposure to BPA from this type of high consumption food. The nanoparticles were easily coated by mixing commercially available magnetite of 20–30 nm mean particle diameter with tetradecanoate at 85 °C for 30 min. The extraction/cleanup procedure involved stirring the samples (3 mL) with 200 mg of tetradecanoate-coated MNPs for 20 min, isolating the sorbent with a Nd–Fe–B magnet and eluting BPA with methanol. The extraction efficiency was not influenced by salt concentrations up to 1 M and pH values over the range 4–9. No cleanup of the extracts was needed, and the method proved matrix-independent. The extracts were analyzed by liquid chromatography, electrospray ionization tandem mass spectrometry. Quantitation was performed by internal standard calibration using BPA-13C12. The limit of quantitation obtained for the method, 0.03 ng mL−1, was below the usual range of concentrations reported for BPA in soft drinks (0.1–3.4 ng mL−1). The proposed method was successfully applied to the determination of BPA in different samples acquired from various supermarkets in southern Spain; the concentrations found ranged from 0.066 to 1.08 ng mL−1. Recoveries from samples spiked with 0.33 ng mL−1 of BPA ranged from 91% to 105% with relative standard deviations from 3% to 8%.  相似文献   

5.
A conducting copolymer of pyrrole and phenol was electrochemically synthesized on steel frits as a sorbent. The applicability of the frit was assessed for the solid-phase extraction of trace amounts of polycyclic aromatic hydrocarbons (PAHs) in aqueous samples followed by HPLC–UV. The coating produced was very adherent and the scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and FTIR spectrum for the coated frit were studied. The effects of various parameters on the efficiency of the solid-phase extraction process, such as the sample loading rate, elution solvent type, salt effect, volume and flow rate of sample and elution solvent were investigated. Under the optimal conditions, the calibration curves were obtained in the range of 0.1–500 ng mL−1 (r2 > 0.98) and the LODs (S/N = 3) were obtained in the range of 0.01–0.08 ng mL−1. Relative standard deviations (RSDs) for intra- and inter-day precision were 2.7–10.2% and 3.6–11.4%, respectively. The recoveries (8 and 40 ng mL−1) ranged from 79% to 115%. The simplicity of experimental procedure, short sample analysis, high extraction efficiency, and the use of low-cost adsorbent show the potential of this method for routine analysis of PAHs in real samples.  相似文献   

6.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

7.
New mercapto-grafted graphene oxide–magnetic chitosan (GO–MC) has been developed as a novel biosorbent for the preconcentration and extraction of mercury ion from water samples. A facile and ecofriendly synthesis procedure was also developed for modification of GO–MC with 3-mercaptopropyltrimethoxysilane. The prepared nanocomposite material (mercapto/GO–MC) was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and energy-dispersive X-ray spectroscopy (EDX). The mercury analysis was performed by continuous-flow cold vapor atomic absorption spectrometry. The parameters affecting the extraction and preconcentration processes were carried out. The optimum conditions were found to be 60 mg of sorbent, pH of 6.5, 10 min for adsorption time, 3 mL of HCl (0.1 mol L−1)/thiourea (2% w/v) as the eluent and 250 mL for breakthrough volume. An excellent linearity was achieved in the range of 0.12–80 ng mL−1 (R2 = 0.999) at a preconcentration factor of 80. The limit of detection and quantification were achieved as 0.06 ng mL−1 and 0.12 ng mL−1, respectively. A good repeatability was obtained with the relative standard deviation (RSD) of 4.7%. Furthermore, real water samples were analyzed and good recoveries were obtained from 95 to 100%.  相似文献   

8.
In this study, we explored a procedure for the preparation of an immunoaffinity (IA) sorbent for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis–mass spectrometry (IA-SPE-CE–MS). We followed a site-specific antibody immobilization approach based on the covalent attachment of the oxidized antibodies through their carbohydrate moieties to hydrazide silica particles, using a polyclonal antibody against Endomorphin 1 and 2 (End1 and End2). The main features of the IA sorbent were studied, such as the amount of hydrazide groups and antibodies attached onto oxidized diol silica particles. Once the procedure was optimized, standard solutions of End1 and End2 were used in order to establish the IA-SPE-CE–MS methodology. Acceptable repeatability, reproducibility and linearity range values were obtained for the proposed methodology. The limits of detection (LODs) of 1 ng mL−1 were approximately 100-fold better than those obtained by CE–MS. Selectivity of the IA sorbent was good but some cross-reactivity against Dynorphin A (1–7) was observed when a mixture of several opioid peptides was analyzed. Human plasma samples spiked with End1 and End2 were also analyzed and both peptides could be detected down to 100 ng mL−1.  相似文献   

9.
Orthogonal array design (OAD) was utilized for the first time to optimize the experimental conditions of ultrasound-assisted emulsification–microextraction (USAEME) for determining chlorinated phenoxyacetic acids (CPAs) in river water samples. The use of ultrasound facilitates the mass transfer of CPAs from an aqueous phase into a water-immiscible organic extraction solvent (dichloromethane, DCM) without adding dispersive solvent to form numerous microdroplets. The water-immiscible extractant was collected by centrifugation, dried under low pressure, reconstituted in methanol–water mixture (1:1), and injected into a HPLC system for the determination of CPAs. The linear range was 2–1000 ng mL−1 (2, 5, 10, 50, 200, 500 and 1000 ng mL−1) for each analyte and the relative standard deviations of CPAs among the seven different concentrations were in the range of 1.5–17.0% (n = 3). The detection limits (signal-to-noise ratio of 3) of CPAs ranged from 0.67 to 1.50 ng mL−1. The ranges of intra-day precision (n = 3) for CPAs at the levels of 5 and 200 ng mL−1 were 3.6–11.9% and 5.3–9.5%, respectively. The range of inter-day precision (n = 3) at 5 and 200 ng mL−1 were 1.4–7.7% and 8.5–12.2%, respectively. The applicability of USAEME for environmental analysis was demonstrated by determining CPAs in river water. The recoveries of CPAs from five-spiked river water samples at 10 and 200 ng mL−1 were 96.3–112.5% and 94.8–109.4%, respectively. The maximum contaminant level (MCL) of 2,4-D in drinking water and the tolerance of residues in food for p-CPA are 70 and 200 μg L−1, respectively, according to the US EPA regulations. These contaminant levels fall in the linear range investigated in this study. In addition, this USAEME method provided detection limits lower than their contaminant levels, which made USAEME an effective sample preparation method for determining organic environmental contaminants, such as CPAs, in river water samples with little consumption of organic solvent.  相似文献   

10.
This paper describes the development and validation of a new procedure for the simultaneous determination of 41 multi-class priority and emerging organic pollutants in water samples using microextraction by packed sorbent (MEPS) followed by large volume injection–gas chromatography–mass spectrometry (LVI–GC–MS). Apart from method parameter optimization the influence of humic acids as matrix components on the extraction efficiency of MEPS procedure was also evaluated. The list of target compounds includes polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs), bisphenol A (BPA) and selected steroid hormones. The performance of the new at-line microextraction-LVI–GC–MS protocol was compared to standard solid-phase extraction (SPE) and LVI–GC–MS analysis. LODs for 100 mL samples (SPE) ranged from 0.2 to 736 ng L−1 were obtained. LODs for 800 μL of sample (MEPS) were between 0.2 and 266 ng L−1. In the case of MEPS methodology even a sample volume of only 800 μL allowed to detect the target compounds. These results demonstrate the high sensitivity of both procedures which permitted to obtain good recoveries (>75%) for all cases. The precision of the methods, calculated as relative standard deviation (RSD) was below 21% for all compounds and both methodologies. Finally, the developed methods were applied to the determination of target analytes in various samples, including snow and wastewater.  相似文献   

11.
A novel ultrasound-assisted surfactant-enhanced emulsification microextraction (UASEME) coupled with high performance liquid chromatography-diode array detection has been developed for the extraction and determination of six carbamate pesticides (metolcarb, carbofuran, carbaryl, pirimicarb, isoprocarb and diethofencarb) in water samples. In the UASEME technique, Tween 20 was used as emulsifier, and chlorobenzene and chloroform were used as dual extraction solvent without using any organic dispersive solvent that is normally required in the previously described common dispersive liquid–liquid microextraction method. Parameters that affect the extraction efficiency, such as the kind and volume of the extraction solvent, the type and concentration of the surfactant, ultrasound emulsification time and salt addition, were investigated and optimized for the method. Under the optimum conditions, the enrichment factors were in the range between 170 and 246. The limits of detection of the method were 0.1–0.3 ng mL−1 and the limits of quantification were between 0.3 and 0.9 ng mL−1, depending on the compounds. The linearity of the method was obtained in the range of 0.3–200 ng mL−1 for metolcarb, carbaryl, pirimicarb, and diethofencarb, 0.6–200 ng mL−1 for carbofuran, and 0.9–200 ng mL−1 for isoprocarb, with the correlation coefficients (r) ranging from 0.9982 to 0.9998. The relative standard deviations varied from 3.2 to 4.8% (n = 5). The recoveries of the method for the six carbamates from water samples at spiking levels of 1.0, 10.0, 50.0 and 100.0 ng mL−1 were ranged from 81.0 to 97.5%. The proposed UASEME technique has demonstrated to be simple, practical and environmentally friendly for the determination of carbamates residues in river, reservoir and well water samples.  相似文献   

12.
This study describes the development of a new analytical method for determining 14 personal care products (PCPs) – nine synthetic musks, four parabens and one insect repellent – in air samples. The method is based on active sampling on sorbent tubes and thermal desorption-gas chromatography–mass spectrometry analysis, and is rapid, sensitive and drastically reduces the risk of sample contamination. Three kinds of tubes and traps were tested, those filled with Tenax TA being the most suitable for this study. Method validation showed good repeatability and reproducibility, low detection limits (between 0.03 ng m−3 for DPMI and 12.5 ng m−3 for propyl paraben) and good linearity for all compounds. Stability during storage indicated that samples must be kept refrigerated at 4 °C and analysed within 1 week of collection. The applicability of the technique to real samples was tested in different indoor and outdoor atmospheres. The total PCP values for indoor air ranged from 135 ng m−3 in a pharmacy to 2838 ng m−3 in a hairdresser's, whereas the values for outdoor air ranged from 14 ng m−3 for a suburban environment to 26 ng m−3 for an urban environment. In general, the most abundant synthetic musks were galaxolide (5.9–1256 ng m−3), musk xylene (1.6–766 ng m−3) and tonalide (1.1–138 ng m−3). Methyl and ethyl paraben (2.4–313 ng m−3 and 1.8–117 ng m−3, respectively) were the most abundant parabens. Although thermal desorption methods have been widely used for determining volatile organic compounds, they are rarely used with semi-volatile compounds. This study thus demonstrates that the thermal desorption method performs well with semi-volatile compounds and, for the first time, that it can be used for determining PCPs.  相似文献   

13.
A headspace solid-phase dynamic extraction (HS-SPDE) technique was developed by the use of polypyrrole (PPy) sorbent, electropolymerized inside the surface of a needle, as a possible alternative to solid-phase microextraction (SPME). Thermal desorption was subsequently, employed to transfer the extracted analytes into the injection port of a gas chromatography-mass spectrometry (GC-MS). The PPy sorbent including polypyrrole-dodecyl sulfate (PPy-DS) was deposited on the interior surface of a stainless steel needle from the corresponding aqueous electrolyte by applying a constant deposition potential. The homogeneity and the porous surface structure of the coating were examined using the scanning electron microscopy (SEM).The developed method was applied to the trace level extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample. In order to enhance the extraction efficiency and increase the partition coefficient of analytes, the stainless steel needle was cooled at 5 °C, while the sample solution was kept at 80 °C. Optimization of influential experimental conditions including the voltage of power supply, the time of PPy electrodeposition, the extraction temperature, the ionic strength and the extraction time were also investigated. The detection limits of the method under optimized conditions were in the range of 0.002-0.01 ng mL−1. The relative standard deviations (R.S.D.) at a concentration level of 0.1 ng mL−1 were obtained between 7.54 and 11.4% (n = 6). The calibration curves of PAHs showed linearity in the range of 0.01-10 ng mL−1. The proposed method was successfully applied to the extraction of some selected PAHs from real-life water samples and the relative recoveries were higher than 90% for all the analytes.  相似文献   

14.
A novel technique for derivatization in a gas chromatograph injection port after a one-step extraction of trace perfluorocarboxylic acids (PFCAs) in water with ion pair formation during dispersive liquid–liquid microextraction (DLLME) was investigated. Tetrabutylammonium hydrogen sulfate (TBAHS) was used as the ion pair reagent. PFCA butyl ester derivatives were formed in the GC injection port and then analyzed using gas chromatography coupled to tandem mass spectrometry with negative chemical ionization. According to our analysis, the operative linear range for PFCA detection from 250 pg mL−1 to 2 μg mL−1 with a relative standard derivation (RSD) below 13%. Detection limits were achieved at the level of 37–51 pg mL−1. This method was successfully applied for the analyzing of PFCAs in river water samples from urban and industrial areas without tedious pretreatment. The concentration range over which PFCAs were detected is from 0.6 ng mL−1 to 604.9 ng mL−1.  相似文献   

15.
A needle trap device (NTD) packed with silica composite of multi-walled carbon nanotubes (MWCNTs) prepared based on sol–gel technique was utilized for sampling and analysis of volatile organohalogen compounds (HVOCs) in air. The performance of the NTD packed with MWCNTs/silica composite as sorbent was examined in a variety of sampling conditions and was compared with NTDs packed with PDMS as well as SPME with Carboxen/PDMS-coated fibers. The limit of detection of NTDs for the GC/MS detection system was 0.01–0.05 ng mL−1 and the limit of quantitation was 0.04–0.18 ng mL−1. The RSD were 1.1–7.8% for intra-NTD comparison intended for repeatability of technique. The NTD-MWCNTs/silica composite showed better analytical performances compared to the NTD-PDMS composite and had the same analytical performances when compared to the SPME-Carboxen/PDMS fibers. The results show that NTD-MWCNTs-GC/MS is a powerful technique for active sampling of occupational/environmental pollutants in air.  相似文献   

16.
A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)–liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME–LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30 s. And injection was completed in 20 s. About 10–20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1 mL min−1 for 2 min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL−1 range. The linear ranges were from 0.1 to 100 ng mL−1. The new SPME–LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.  相似文献   

17.
The hollow fiber-based stirring extraction bar liquid–liquid microextraction was applied to the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, 17-α-hydroxyprogesterone, medroxyprogesterone, progesterone and norethisterone acetate, in milk. The present method has the advantages of both hollow fiber-liquid phase microextraction and stirring bar sorptive extraction. The stirring extraction bar was used as both the stirring bar of microextraction, and extractor of the analytes, which can make extraction, clean-up and concentration be carried out in one step. When the extraction was completed, the stirring extraction bar was easy isolated from the extraction system with the magnet. Several experimental parameters, including the type of extraction solvent, the number of hollow stirring extraction bar, extraction time, stirring speed, ionic strength, and desorption conditions were investigated and optimized. The analytes in the extract were derived and determined by gas chromatography mass spectrometry. Under optimal experimental conditions, good linearity was observed in the range of 0.20–20.00 ng mL−1. The limits of detection and quantification were in the range of 0.02–0.06 ng mL−1 and 0.07–0.19 ng mL−1, respectively. The present method was applied to the analysis of milk samples, and the recoveries of analytes were in the range of 93.6–104.6% with the relative standard deviations ranging from 1.6% to 6.2% (n = 5). The results showed that the present method was a rapid and feasible method for the determination of hormones in milk samples.  相似文献   

18.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

19.
Liu X  Yin J  Zhu L  Zhao G  Zhang H 《Talanta》2011,85(5):2451-2457
A porous polysulfone microcapsule containing organic modified montmorillonite and magnetic nanoparticles (OMMT-Fe3O4@PSF) has been successfully prepared by a phase-inversion method and evaluated as a magnetic solid-phase extraction (MSPE) sorbent for clean-up and enrichment of 4-chlorophenol (4-CP) and 2-chlorophenol (2-CP) in aqueous samples. Compared with a microcapsule containing the conventional extraction sorbent C18 (C18-Fe3O4@PSF), OMMT-Fe3O4@PSF had much lower cost, a faster adsorption rate, and superior uptake amounts for the investigated analytes. The proposed microcapsule has been developed for the extraction of 4-CP and 2-CP from environmental water samples and their analysis by high-performance liquid chromatography with UV detection (HPLC-UV). Various parameters, such as pH, extraction time, the mass of sorbent, and the desorption conditions, have been evaluated and the calibration curves of the chlorophenols were linear (R2 ≥ 0.9985) in the range from 1.01 to 104.5 ng mL−1. The limits of detection at a signal-to-noise (S/N) ratio of 3 were 0.22 and 0.17 ng mL−1 and the limits of quantification calculated at S/N = 10 were 1.52 and 1.07 ng mL−1 for 2-CP and 4-CP, respectively. The recoveries of 2-CP and 4-CP from natural water and the treated wastewater samples were in the range of 84.4-115% with relative standard deviations (RSDs) lower than 7.0%. The results have demonstrated the suitability of the MSPE approach for the analysis of trace chlorophenols in aqueous samples.  相似文献   

20.
Abdorreza Mohammadi 《Talanta》2009,78(3):1107-1114
A simple and rapid headspace solid-phase microextraction (HS-SPME) based method is presented for the simultaneous determination of atrazine and ametryn in soil and water samples by ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS), synthesized by electrochemical method, was applied as a laboratory-made fiber for SPME. The HS-SPME system was designed with a cooling device on the upper part of the sample vial and a circulating water bath for adjusting the sample temperature. The extraction properties of the fiber to spiked soil and water samples with atrazine and ametryn were examined, using a HS-SPME device and thermal desorption in injection port of IMS. Parameters affecting the extraction efficiency such as the volume of water added to the soil, pH effect, extraction time, extraction temperature, salt effect, desorption time, and desorption temperature were investigated. The HS-SPME-IMS method with PPy-DS fiber, provided good repeatability (RSDs < 10 %), simplicity, good sensitivity and short analysis times for spiked soil (200 ng g−1) and water samples (100 and 200 ng mL−1). The calibration graphs were linear in the range of 200-4000 ng g−1 and 50-2800 ng mL−1 for soil and water respectively (R2 > 0.99). Detection limits for atrazine and ametryn were 37 ng g−1 (soil) and 23 ng g−1 (soil) and 15 ng mL−1 (water) and 10 ng mL−1 (water), respectively. To evaluate the accuracy of the proposed method, atrazine and ametryn in the three kinds of soils and two well water samples were determined. Finally, comparing the HS-SPME results for extraction and determination of selected triazines using PPy-DS fiber with the other methods in literature shows that the proposed method has comparable detection limits and RSDs and good linear ranges.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号