首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
In this work, Ni@Pt core‐shell nanoparticles with diameter of 3–4 nm and thin Pt shell was synthesized by a successive reduction approach using carbon as support to develop high‐performance non‐enzymatic glucose sensor. The resulting electrochemical sensor displayed good catalytic activity toward glucose oxidation, presenting a high current density of 66.9 µA mM?1 cm?2 at an applied potential of ?0.1 V. It showed a wide linear range of 0.1–30.1 mM and the limit of detection was down to 30 µM (S/N=3). Notably, it was found that the proposed sensor exhibited good selectivity to avoid the interference from ascorbic acid, uric acid, fructose and acetamidophenol. Furthermore, the feasibility of the as‐prepared non‐enzymatic glucose sensor in the determination of glucose in serum samples was successfully implemented.  相似文献   

2.
A novel flower like 3D nickel/manganese dioxide (Ni/MnO2) nanocomposite was synthesized by a kind of simple electrochemical method and the formation mechanism of flower like structure was also researched. In addition, morphology and composition of the nanocomposite were characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), and X‐ray photoelectron spectroscopy (XPS). Then the Ni/MnO2 nanocomposites were applied to fabricate electrochemical non‐enzymatic glucose sensor. The electrochemical investigation for the sensor indicated that it possessed an excellent electrocatalytic property for glucose, and could applied to the quantification of glucose with a linear range from 2.5×10?7 to 3.5×10?3 M, a sensitivity of 1.04 mA mM?1 cm?2, and a detection limit of 1×10?7 M (S/N=3). The proposed sensor also presented attractive features such as interference‐free, and long‐term stability. The present study provided a general platform for the one‐step synthesis of nanomaterials with novel structure and can be extended to other optical, electronic and magnetic nanocompounds.  相似文献   

3.
Novel nickel‐copper modified pencil graphite electrode (Ni?Cu/PGE) was fabricated and used as non‐enzymatic sensor for glucose determination. Ni and copper were electrodeposited on PGE using cyclic voltammetry. Morphology and composition of the modified PGE electrode were characterized by field‐emission gun scanning electron microscopy (FEG‐SEM), energy‐dispersive X‐ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT‐IR). Electrochemical oxidation of glucose was evaluated by cyclic voltammetry as well as by amperometry. Electrochemical measurements indicate that the Ni?Cu/PGE exhibits a high sensitivity of 2951 μA mM?1 cm?2, and a low detection limit of 0.99 μM which are, respectively, three times higher and twice lower than that on Ni/PGE prepared in the same conditions. Moreover, Ni?Cu/PGE exhibits a wider linear range from 1 to 10000 μM with a rapid response time within 2 s. Moreover, Ni?Cu/PGE showed a remarkable stability. The electrode was successfully applied for determination of glucose concentration in human blood without significant interference from potential endogenic interferents. The good applicability of the elaborated sensor made Ni?Cu/PGE promising for the development of effective and inexpensive non‐enzymatic glucose sensor.  相似文献   

4.
《Electroanalysis》2017,29(2):423-432
In the present paper, a stable and selective non‐enzymatic sensor is reported for determination of glucose (Glc) by using a carbon paste electrode modified with multiwall carbon nanotubes and Ni(II)‐SHP complex as modifier in an alkaline solution. This modified electrode showed impressive activity for oxidation of glucose in NaOH solution. Herein, Ni(II)‐SHP acts as a suitable platform for oxidation of glucose to glucolactone on the surface of the modified electrode by decreasing the overpotential and increasing in the current of analyte. Under the optimum conditions, the rate constant and electron transfer coefficient between electrode and modifier, were calculated to be 1.04 s−1 and 0.64, respectively. The anodic peak currents indicated a linear dependency with the square root of scan rate and this behavior is the characteristic of a diffusion controlled process. So, the diffusion coefficient of glucose was found to be 3.12×10−6 cm2 s−1 due to the used number of transferred electron of 1. The obtained results revealed two linear ranges (5 to 190.0 μM (R2=0.997), 210.0 to 700.0 μM (R2=0.999)) and the detection limit of 1.3 μM for glucose was calculated by using differential pulse voltammetry (DPV) method. Also, the designed sensor was used for determination of glucose in the blood serum and urine samples. Some other advantages of Ni(II)‐SHP/CNT/CPE sensor are remarkable reproducibility, stability and selectivity which can be related to using nanomaterial of carbon nanotubes due to enhancement of electrode surface area.  相似文献   

5.
The preparation of NiCo2S4 (NCS) nanosheets on photolithographically patterned platinum electrodes by electrodeposition was explored. The as‐prepared nanosheets were systematically characterized by field‐emission scanning electron microscopy, energy‐dispersive X‐ray spectroscopy, and X‐ray photoelectron spectroscopy techniques. The NCS‐modified Pt electrode was used as a non‐enzymatic glucose sensor. The sensor response exhibited two linear regions in glucose concentration, with a limit of detection of 1.2 μm . The sensors showed that the as‐prepared NCS nanosheets have excellent electrocatalytic activity towards glucose with long stability, good reproducibility, and excellent anti‐interference properties, and thus, this material holds promise for the development of a practical glucose sensor.  相似文献   

6.
《Electroanalysis》2017,29(7):1755-1761
As a promising electrode material, Ni‐based nanomaterials exhibit a remarkable electrochemical catalytic activity for nonenzymatic glucose sensors. In this paper, Nickel–Iron layered double hydroxide (NiFe‐LDH) film electrode with ultrathin nanosheets and porous nanostructures was synthesized directly on Ni foam (NF) by a one‐step hydrothermal method. The as‐obtained NiFe‐LDH electrode was adopted for glucose detection without further treatment. As an integrated binder‐free electrode for glucose sensor, the NiFe‐LDH/NF hybrid exhibits a superior sensitivity of 3680.2 μA mM−1 cm−2 with a low limit of detection (0.59 μM, S/N=3) as well as fast response time (<1 s). An excellent selectivity from potential interference species such as ascorbic acid, uric acid and Cl ions and acceptable stability were also achieved. The outstanding performance can be ascribed to the abundant electrochemistry active sites, facilitative diffusion of the electrolyte, high electron transfer rate and reliable stability architecture. Therefore, the NiFe‐LDH nanosheets demonstrate potential application in non‐enzymatic sensory of glucose.  相似文献   

7.
Nanostructured NiS thin film was prepared by a one‐step electrodeposition method and the structural, morphological characteristics of the as‐prepared films were analyzed by X‐ray diffractometry (XRD), field emission scanning electron microscopy (FESEM) and energy dispersive X‐ray analysis (EDAX). The electrocatalytic activity of NiS thin film towards glucose oxidation was investigated by fabricating a non‐enzymatic glucose sensor and the sensor performance was studied by cyclic voltammetry (CV) and amperometry. The fabricated sensor showed excellent sensitivity and low detection limit with values of 7.43 μA μM ?1 cm?2 and 0.32 μM , respectively, and a response time of <8 s.  相似文献   

8.
The flavocytochrome cellobiose dehydrogenase (CDH) is a versatile biorecognition element capable of detecting carbohydrates as well as quinones and catecholamines. In addition, it can be used as an anode biocatalyst for enzymatic biofuel cells to power miniaturised sensor–transmitter systems. Various electrode materials and designs have been tested in the past decade to utilize and enhance the direct electron transfer (DET) from the enzyme to the electrode. Additionally, mediated electron transfer (MET) approaches via soluble redox mediators and redox polymers have been pursued. Biosensors for cellobiose, lactose and glucose determination are based on CDH from different fungal producers, which show differences with respect to substrate specificity, pH optima, DET efficiency and surface binding affinity. Biosensors for the detection of quinones and catecholamines can use carbohydrates for analyte regeneration and signal amplification. This review discusses different approaches to enhance the sensitivity and selectivity of CDH-based biosensors, which focus on (1) more efficient DET on chemically modified or nanostructured electrodes, (2) the synthesis of custom-made redox polymers for higher MET currents and (3) the engineering of enzymes and reaction pathways. Combination of these strategies will enable the design of sensitive and selective CDH-based biosensors with reduced electrode size for the detection of analytes in continuous on-site and point-of-care applications.  相似文献   

9.
Non‐enzymatic glucose sensor is greatly expected to take over its enzymatic counterpart in the future. In this paper, we reported on a facile strategy to construct a non‐enzymatic glucose sensor by use of NiCo2O4 hollow nanocages (NiCo2O4 HNCs) as catalyst, which was derived from Co‐based zeolite imidazole frame (ZIF‐67). The NiCo2O4 HNCs modified glassy carbon electrode (NiCo2O4 HNCs/GCE), the key component of the glucose sensor, showed highly electrochemical catalytic activity towards the oxidation of glucose in alkaline media. As a result, the proposed non‐enzymatic glucose sensor afforded excellent analytical performances assessed with the aid of cyclic voltammetry and amperometry (i–t). A wide linear range spanning from 0.18 μΜ to 5.1 mM was achieved at the NiCo2O4 HNCs/GCE with a high sensitivity of 1306 μA mM?1 cm?2 and a fast response time of 1 s. The calculated limit of detection (LOD) of the sensor was as low as 27 nM (S/N=3). Furthermore, it was demonstrated that the non‐enzymatic glucose sensor showed considerable anti‐interference ability and excellent stability. The practical application of the sensor was also evaluated by determination of glucose levels in real serum samples.  相似文献   

10.
A simple and effective glucose biosensor based on immobilization of glucose oxidase (GOD) in graphene (GR)/Nafion film was constructed. The results indicated that the immobilized GOD can maintain its native structure and bioactivity, and the GR/Nafion film provides a favorable microenvironment for GOD immobilization and promotes the direct electron transfer between the electrode substrate and the redox center of GOD. The electrode reaction of the immobilized GOD shows a reversible and surface‐controlled process with the large electron transfer rate constant (ks) of 3.42±0.08 s?1. Based on the oxygen consumption during the oxidation process of glucose catalyzed by the immobilized GOD, the as‐prepared GOD/GR/Nafion/GCE electrode exhibits a linear range from 0.5 to 14 mmol·L?1 with a detection limit of 0.03 mmol·L?1. Moreover, it displays a good reproducibility and long‐term stability.  相似文献   

11.
《Analytical letters》2012,45(3):431-440
Abstract

Continuous glucose monitoring (CGM) is expected to become an ideal way to monitor glycemic levels in diabetic patients. On the other hand, biofuel cells can be used as an alternative energy source in future implantable devices, such as implantable glucose sensors in the artificial pancreas. Glucose dehydrogenase from Acinetobacter calcoaceticus, which harbors pyrroloquinoline quinone as the prosthetic group (PQQGDH), is one of the enzymes most attractive as a glucose sensor constituent and as the anode enzyme in biofuel cells, due to its high catalytic activity and insensitivity to oxygen. However, the application of PQQGDH for these purposes is inherently limited because an electron mediator is required for the electron transfer to the electrode.

We have recently reported on the development of an engineered enzyme, quinohemoprotein glucose dehydrogenase (QH‐GDH), in which the cytochrome c domain of the quinohemoprotein ethanol dehydrogenase (QH‐EDH) was fused with PQQGDH, to enable electron transfer to the electrode in the absence of an artificial mediator. In this study, we constructed a direct electron‐transfer‐type CGM system employing QH‐GDH. This CGM system showed sufficient current response and high operational stability. Furthermore, we successfully constructed a compartmentless biofuel cell employing QH‐GDH.  相似文献   

12.
The enzymatic oxidative decarboxylation of linear short‐chain fatty acids (C4:0–C9:0) employing the P450 monooxygenase OleT, O2 as the oxidant, and NAD(P)H as the electron donor gave the corresponding terminal C3 to C8 alkenes with product titers of up to 0.93 g L?1 and TTNs of >2000. Key to this process was the construction of an efficient electron‐transfer chain employing putidaredoxin CamAB in combination with NAD(P)H recycling at the expense of glucose, formate, or phosphite. This system allows for the biocatalytic production of industrially important 1‐alkenes, such as propene and 1‐octene, from renewable resources for the first time.  相似文献   

13.
Glucose oxidase (GOD) was encapsulated in chitosan matrix and immobilized on a glassy carbon electrode, achieving direct electron transfer (DET) reaction between GOD and electrode without any nano‐material. On basis of such DET, a novel glucose biosensor was fabricated for direct bioelectrochemical sensing without any electron‐mediator. GOD incorporated in chitosan films gave a pair of stable, well‐defined, and quasireversible cyclic voltammetric peaks at about ?0.284 (Epa) and ?0.338 V (Epc) vs. Ag/AgCl electrode in phosphate buffers. And the peak is located at the potentials characteristic of FAD redox couples of the proteins. The electrochemical parameters, such as midpoint potential (E1/2) and apparent heterogeneous electron‐transfer rate constants (ks) were estimated to ?0.311 V and 1.79 s?1 by voltammetry, respectively. Experimental results indicate that the encapsulated GOD retains its catalytic activity for the oxidation of glucose. Such a GOD encapsulated chitosan based biosensor revealed a relatively rapid response time of less than 2 min, and a sufficient linear detection range for glucose concentration, from 0.60 to 2.80 mmol L?1 with a detection limit of 0.10 mmol L?1 and electrode sensitivity of 0.233 μA mmol?1. The relative standard deviation (RSD) is under 3.2% (n=7) for the determination of practical serum samples. The biologic compounds probably existed in the sample, such as ascorbic acid, uric acid, dopamine, and epinephrine, do not affect the determination of glucose. The proposed method is satisfactory to the determination of human serum samples compared with the routine hexokinase method. Both the unique electrical property and biocompatibility of chitosan enable the construction of a good bio‐sensing platform for achieved DET of GOD and developed the third‐generation glucose biosensors.  相似文献   

14.
In this paper a new electrochemical method based on the ionic liquid modified carbon paste electrode (IL‐CPE) was proposed for the determination of adenosine‐5′‐triphosphate (ATP) in a pH 4.5 Britton‐Robinson (B‐R) buffer solution. IL‐CPE was prepared by using 1‐butyl‐3‐methylimidazolium trifluoroacetate (BMIMCF3COO) as the modifier. Cyclic voltammetry was used to investigate the electrochemical behaviors of ATP on the IL‐CPE, and the results indicated that IL‐CPE exhibited strong electrocatalytic ability to promote the oxidation of ATP with a single well‐defined irreversible adsorption‐controlled oxidation peak appeared. The electrochemical reaction parameters of ATP were calculated with the results of the electron transfer coefficient (α) as 0.40, the electron transfer number (n) as 1.17, the apparent heterogeneous electron transfer rate constant (ks) as 3.66 × 10‐6 s‐1 and the surface coverage (Γτ) as 2.48 × 10‐9 mol cm‐2. Under the selected conditions the proposed IL‐CPE showed good performances to the ATP detection in the concentration range from 0.1 to 1000.0 μmol L‐1 with the detection limit as 3.65 × 10‐8 mol L‐1 (3σ) by differential pulse voltammetry. The method showed good selectivity to the ATP detection without the interferences of coexisting substances and was successfully applied to the ATP injection samples detection with satisfactory results.  相似文献   

15.
A novel non‐enzymatic sensor based on Ag/MnOOH nanocomposites was developed for the detection of hydrogen peroxide (H2O2). The H2O2 sensor was fabricated by immobilizing Ag/MnOOH nanocomposites on a glassy carbon electrode (GCE). The morphology and composition of the sensor surface were characterized using scanning electron microscopy, energy‐dispersive X‐ray spectroscopy, transmission electron microscopy and X‐ray diffraction spectroscopy. The electrochemical investigation of the sensor indicates that it possesses an excellent electrocatalytic property for H2O2, and could detect H2O2 in a linear range from 5.0 µM to 12.8 mM with a detection limit of 1.5 µM at a signal‐to‐noise ratio of 3, a response time of 2 s and a sensitivity of 32.57 µA mM?1 cm?2. Additionally, the sensor exhibits good anti‐interference. The good analytical performance, low cost and straightforward preparation method made this novel electrode material promising for the development of effective non‐enzymatic H2O2 sensor.  相似文献   

16.
This article reports the fabrication of Acid Violet 34 (AV34)/nickel hydroxide nanosheets ultrathin film on the glassy carbon electrode (GCE) via the electrostatic layer‐by‐layer (LBL) technique, and its electrocatalytic oxidation for glucose was demonstrated. UV‐vis absorption and electrochemical impedance spectra indicate the uniform deposition of the LBL film, with a continuous and smooth film surface observed by SEM and AFM. The electrochemical performance of the ultrathin film was studied by cyclic voltammetry and chronoamperometry. The (AV34/Ni(OH)2)5 ultrathin film modified electrode displays a fast direct electron transfer attributed to the Ni2+/Ni3+ redox couple as well as remarkable electrocatalytic activity towards the oxidation of glucose. The linear response was obtained in the range 0.5–13.5 mM (R=0.9994) with a low detection limit (14 µM), high sensitivity (25.9 µA mM?1 cm?2), rapid response (less than 1 s) and excellent anti‐interference properties to the species including ascorbic acid (AA), uric acid (UA), acetamidophenol (AP) and structurally related sugars. Therefore, the AV34/Ni(OH)2 ultrathin film can be potentially used as a feasible electrochemical sensor for the determination of glucose.  相似文献   

17.
We have synthesized six p‐type copolymers, CPDT ‐ co ‐ TPADCN , CPDT ‐ co ‐ TPADTA , CPDT ‐ co ‐ TPATCN , CPDT ‐ co ‐ DFADCN , CPDT ‐ co ‐ DFADTA , and CPDT ‐ co ‐ DFATCN , consisting of a cyclopenta[2,1‐b:3,4‐b′]dithiophene (CPDT) unit and an organic dye in an alternating arrangement. Triphenylamine (TPA) or difluorenylphenyl amine (DFA) units serve as the electron donors, whereas dicyanovinyl (DCN), 1,3‐diethyl‐2‐thiobarbituric acid, or tricyanovinyl (TCN) units act as the electron acceptors in the dyes. The target polymers were prepared via Stille coupling, followed by postfunctionalization to introduce the electron acceptors to the side chains. Because of the strongest withdrawing ability of TCN acceptor to induce efficient intramolecular charge transfer, CPDT ‐ co ‐ TPATCN and CPDT ‐ co ‐ DFATCN exhibit the broader absorption spectra covering from 400 to 900 nm and the narrower optical band gaps of 1.34 eV. However, the CPDT ‐ co ‐ TPATCN :PC71BM and CPDT ‐ co ‐ DFATCN :PC71BM based solar cells showed the power conversion efficiencies (PCEs) of 0.22 and 0.31%, respectively, due to the inefficient exciton dissociation. The DFA‐based polymers possess deeper‐lying HOMO energy levels than the TPA‐based polymer analogues, leading to the higher Voc values and better efficiencies. The device based on CPDT ‐ co ‐ DFADTA :PC71BM blend achieved the best PCE of 1.38% with a Voc of 0.7 V, a Jsc of 4.57 mA/cm2, and a fill factor of 0.43. © 2011 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2011  相似文献   

18.
A new electrochemical method was proposed for the determination of adenosine‐5′‐triphosphate (ATP) based on the electrooxidation at a molecular wire (MW) modified carbon paste electrode (CPE), which was fabricated with diphenylacetylene (DPA) as the binder. A single well‐defined irreversible oxidation peak of ATP appeared on MW‐CPE with adsorption‐controlled process and enhanced electrochemical response in a pH 3.0 Britton‐Robinson buffer solution, which was due to the presence of high conductive DPA in the electrode. The electrochemical parameters of ATP were calculated with the electron transfer coefficient (α) as 0.54, the electron transfer number (n) as 1.9, the apparent heterogeneous electron transfer rate constant (ks) as 2.67 × 10?5 s?1 and the surface coverage (ΓT) as 4.15 × 10?10 mol cm?2. Under the selected conditions the oxidation peak current was proportional to ATP concentration in the range from 1.0 × 10?7 mol L?1 to 2.0 × 10?3 mol L?1 with the detection limit as 1.28 × 10?8 mol L?1 (3σ) by sensitive differential pulse voltammetry. The proposed method showed good selectivity without the interferences of coexisting substances and was successful applied to the ATP injection samples detection.  相似文献   

19.
The direct electrochemistry of glucose oxidase (GOD) immobilized on the designed titanium carbide‐Au nanoparticles‐fullerene C60 composite film modified glassy carbon electrode (TiC‐AuNPs‐C60/GCE) and its biosensing for glucose were investigated. UV‐visible and Fourier‐transform infrared spectra of the resulting GOD/TiC‐AuNPs‐C60 composite film suggested that the immobilized GOD retained its original structure. The direct electron transfer behaviors of immobilized GOD at the GOD/TiC‐AuNPs‐C60/GCE were investigated by cyclic voltammetry in which a pair of well‐defined, quasi‐reversible redox peaks with the formal potential (E0′) of ‐0.484 V (vs. SCE) in phosphate buffer solution (0.05 M, pH 7.0) at the scan rate of 100 mV·s?1 were obtained. The proposed GOD modified electrode exhibited an excellent electrocatalytic activity to the reduction of glucose, and the currents of glucose reduction peak were linearly related to glucose concentration in a wider linearity range from 5.0 × 10?6 to 1.6 × 10?4 M with a correlation coefficient of 0.9965 and a detection limit of 2.0 × 10?6 M (S/N = 3). The sensitivity and the apparent Michaelis‐Menten constant (KMapp) were determined to be 149.3 μA·mM?1·cm?2 and 6.2 × 10?5 M, respectively. Thus, the protocol will have potential application in studying the electron transfer of enzyme and the design of novel electrochemical biosensors.  相似文献   

20.
Pd nanoparticles with an average diameter of 5 nm were decorated on the surface of ionic liquid derived fibrillated mesoporous carbon (IFMC) to prepare a novel nano‐hybrid material (Pd@IFMC). Thereafter, glucose oxidase was immobilized on Pd@IFMC modified glassy carbon electrode to fabricate an enzymatic glucose biosensor. A pair of well‐defined redox peaks was recorded for direct electron transfer of the immobilized glucose oxidase at the formal potential of ? 0.418 V with a peak to peak separation of 25 mV. Electron transfer rate constant of was calculated to be 14.6 s?1. The response of fabricated biosensor was linear towards glucose concentration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏