首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2005,17(8):685-693
Carbon paste electrodes were modified by mixing appropriate amounts of the monomers o‐phenylendiamine, p‐phenylendiamine and m‐phenylendiamine (o‐PD, p‐PD and m‐PD) into a graphite powder‐paraffin oil matrix. The electropolymerization of the incorporated phenylendiamine was then carried out in a carbon paste electrode in acidic medium by cyclic voltammetry between ?0.30 V and +0.90 or under constant potential. The modified carbon paste electrodes (MCPEs) obtained by this electropolymerization method were found to be useful for trace determination of Pb2+ in aqueous solutions. Lead(II) was first preconcentrated on the modified electrodes by complexation with the modifier, and the electrode was then transferred to an electrochemical cell. The best results in terms of sensitivity and detection limit were obtained with poly p‐phenylenediamine (poly (p‐PD)). For a 10‐min preconcentration time, the calibration plot was linear from 5×10?8 mol L?1 to 10?5 mol L?1, with r2=0.999 and relative standard deviation equal to 5%. However, the lowest lead concentration that could be detected was 10?9 mol L?1. Interference from metal ions like Cd(II), Hg(II), Zn(II), Fe(II) and Cu(II) was also studied.  相似文献   

2.
A novel electrochemical cell design is proposed to allow fast, reproducible and highly efficient convective transport of dissolved substances to screen‐printed electrochemical three‐electrode strips mounted on miniaturized plastic vessels, with the goal of improving detection limits in disposable electrochemical stripping field sensors. The experimental configuration has been tested for accumulation of the selected heavy metals ions Zn(II), Cd(II), and Pb(II), codeposited with bismuth ions on a carbon disk screen‐printed working electrode before detection by square wave anodic stripping voltammetry. Chemical and instrumental variables of the proposed device and associate electrochemical method were optimized. Selected parameters gave detection limits in the low ng mL?1 range with moderate deposition time (120 s). Practical applicability was tested on certified water and real samples (tap water and waste water), with acceptable results, suggesting potential usefulness for field environmental monitoring of heavy metals.  相似文献   

3.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

4.
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand [2‐mercapto‐5‐(3‐nitrophenyl)‐1,3,4‐thiadiazole] (MNT), self‐assembled to gold nanoparticles (GNP) as suitable carrier for Cd(II) ion with potentiometric method are described. The proposed electrode exhibits a Nernstian slope of 29.4±1.0 mV per decade for Cd(II) ion over a wide concentration range from 3.1×10?8 to 3.1×10?4 mol L?1. The detection limit of electrode was 2.0×10?8 mol L?1 of cadmium ion. The potentiometric responses of electrode based on MNT is independent of the pH of test solution in the pH range 2.0–4.0. It has quick response with response time of about 6 s. The proposed electrode show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrode was successfully employed to detect Cd(II) ion in hair and water samples.  相似文献   

5.
Ersin Demir 《Electroanalysis》2019,31(8):1545-1553
In the present study, desmedipham, used as an herbicide to control broad leaf weed in commonly sugar beet crops, was analyzed at the first time by cyclic voltammetry (CV) and square wave stripping voltammetry (SWSV) with the modified carbon paste electrode based on hematite nanoparticles (α‐Fe2O3?CPE). The modified α‐Fe2O3?CPE prepared by hematite (α‐Fe2O3 nanoparticles), which is very sensitive to carbon paste electrode (CPE) and glassy carbon electrode (GCE). Morphology of electrode surface detailed by scanning electron microscopy (SEM) and energy dispersive X‐ray analysis (EDX). The oxidation of desmedipham created irreversible well‐done two peaks at nearly +1.1 and +1.3 V. In order to obtain the best calibration graph, various important parameters such as pH, accumulation time, puls amplitude and frequency etc. were investigated. Under the optimum conditions, electrochemical behavior of desmedipham presented two linear working ranges at 0.15–1.20 mg/L and 1.20–4.50 mg/L. The limits of detection (LOD) for the desmedipham were calculated as 41.00 and 50.00 μg/L for the peak I and II, respectively. Furthermore, desmedipham was analyzed at high recovery in the presence of rizolex, fluometuron, teflubenzuron and some heavy metal ions. Consequently, the developed SWSV was successfully applied to evaluate desmedipham in spiked commercial strawberry juices at recoveries of 96.00–104.00 % with satisfactory relative standard deviations.  相似文献   

6.
In this work, a green technique for preparing TbFeO3/CuO was reported by employing Crataegus and Lantana Camara leaves as fuel and alkalizing agents, respectively. The new sensor based on the perovskite-type nanocomposite was employed as a sensitive and selective platform to detect Pb(II), Zn(II) and Cd(II) simultaneously. TbFeO3/CuO/Carbon paste electrode (CPE) exhibited a large specific surface area and great electrical conductivity, which enhanced electron transport in the electrochemical process considerably. Moreover, square wave anodic stripping voltammetry (SWASV) was used for the investigation of some factors influencing the sensor sensitivity like pH, modifier concentration, as well as accumulation time and potential. Therefore, the low detection limit (LOD) and a wide linear range were obtained at optimum conditions. In this study, a linear range between 0.9 and 110 µg/L for three ions and LOD of 0.48, 0.29 and 0.12 for zinc, cadmium and lead were achieved, respectively. Moreover, TbFeO3/CuO/CPE was employed to detect zinc, cadmium and lead ions simultaneously in the real samples so that the results have shown consistency with a standard inductively coupled plasma (ICP).  相似文献   

7.
The detection of Allura red (AR) by electrochemical reduction using a different electrode from the conventional mercury electrode is presented. A carbon paste with cobalt (II, III) oxide composite electrode (CoOx/CPE) is reported for the first time for the detection of AR. Moreover, others dyes such as tartrazine (TZ), sunset yellow (SY), amaranth (AM), Ponceaut 4‐R (P‐4R), and Sudan (SD) as well as pharmaceutical agents such as paracetamol (PMC) that are present in samples that contained AR did not show a reduced signal between 0.0 and ?0.3 V, which is the potential range where AR reduction was observed. The surface electroactivity was studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The presence of CoOX increased the cathodic peak current for AR by more than 50 % and 65 % via CV and square wave voltammetry (SWV), respectively, compared with an unmodified carbon paste electrode. Under the optimal parameters, (pH=3.0, accumulation time (tACC)=60 s and accumulation potential (EACC)=0.50 V), the detection limit for AR was 0.05 μmol L?1. The new sensor was sensitive and stable for the detection of AR. Moreover, it was easily manufactured and very convenient for food samples such as soft and isotonic drinks as well as chili sauce.  相似文献   

8.
A chemically modified electrode was constructed for rapid, simple, accurate, selective and highly sensitive simultaneous determination of Cu(II) and Cd(II) using square wave anodic stripping voltammetry. The electrode was prepared by incorporation of SiO2 nanoparticles, coated with a newly synthesized Schiff base, in carbon paste electrode. The limit of detection was found to be 0.28 ng mL?1 and 0.54 ng mL?1 for Cu(II) and Cd(II), respectively. The proposed chemically modified electrode was used for the determination of copper and cadmium in several foodstuffs and water samples.  相似文献   

9.
《Electroanalysis》2017,29(3):880-889
A new method for modifying electrodes with Ag nanoparticles (AgNPs) using electrospray deposition for sensitive, selective detection of Zn(II), Cd(II), and Pb(II) in aerosol samples when combined with Bismuth and Nafion coating and square‐wave anodic stripping voltammetry (SWASV) is reported. Carbon stencil‐printed electrodes (CSPEs) fabricated on a polyethylene transparency (PET) sheet were produced for an inexpensive, simple to fabricate, disposable sensor that can be used with the microliter sample volumes for analysis. Sensor performance was improved by modifying the electrode surface with electrospray‐deposited AgNPs. The use of electrospray deposition resulted in more uniform particle dispersion across the electrode surface when compared to drop‐casting. Using AgNP‐modified electrodes combined with Bi and Nafion, experimental detection limits (LODs) of 5.0, 0.5, and 0.1 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively, were achieved. The linear working ranges were 5.0–400.0 μg L−1, 0.5–400.0 μg L−1, and 0.1–500.0 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively. Interference studies showed Cu(II) was the only metal that interfered with this assay but inference could be eliminated with the addition of ferricyanide directly to the sample solution. This electrochemical sensor was applied for the simultaneous determination of Zn(II), Cd(II), and Pb(II) within source particulate matter (PM) samples collected on filters using an aerosol test chamber.  相似文献   

10.
This research introduces the design of an adsorptive stripping voltammetric method for the cerium(III) determination at a carbon paste electrode, chemically modified with dipyridyl‐functionalized nanoporous silica gel (DPNSG‐CPE). The electroanalytical procedure comprised two steps: the Ce(III) chemical accumulation at ?200 mV followed by the electrochemical detection of the Ce(III)/dipyridyl complex, using anodic stripping voltammetry. The factors, influencing the adsorptive stripping performance, were optimized including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The resulting electrode demonstrated a linear response over a wide range of Ce(III) concentration (1.0–28 ng mL?1). The precision for seven determinations of 4 and 10 ng mL?1 Ce(III) was 3.2% and 2.5% (relative standard deviation), respectively. The prepared electrode was used for the cerium determination in real samples and very good recovery results were obtained.  相似文献   

11.
《Electroanalysis》2006,18(2):169-176
Constant current chronopotentiometric stripping analysis using adsorptive accumulation and negative stripping current (AdSCP) was applied for the study of behavior of rabbit liver Cd‐Zn and Zn metallothionein (Cd‐Zn‐MT, ZnMT) on hanging mercury drop electrode. Electrochemically inert or labile behavior of complexes can be distinguished with the application of high (1000 nA) or low (100 to 20 nA) current. Using high current, no influence of added Cd2+ or Zn2+ ions on the reduction of Cd(II) or Zn(II) complexed within MT molecule was observed, except of additions of Cd2+ to ZnMT, where bound Zn(II) was substituted by cadmium ions. With lowering of stripping current and increasing concentration of added Cd2+ or Zn2+ ions in solution progressive formation of reorganized complex with labile behavior is observed. Parallel measurement using DC voltammetry with different rates of polarization or differential pulse voltammetry were in agreement with AdSCP measurement. However, only chronopotentiometric method combines good sensitivity and signal separation at μM concentrations, inevitable in MT studies.  相似文献   

12.
A new hemoglobin (Hb) and carbon nanotube (CNT) modified carbon paste electrode was fabricated by simply mixing the Hb, CNT with carbon powder and liquid paraffin homogeneously. To prevent the leakage of Hb from the electrode surface, a Nafion film was further applied on the surface of the Hb‐CNT composite paste electrode. The modified electrode was characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Direct electrochemistry of hemoglobin in this paste electrode was easily achieved and a pair of well‐defined quasi‐reversible redox peaks of a heme Fe(III)/Fe(II) couple appeared with a formal potential (E0′) of ?0.441 V (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical behaviors of Hb in the composite electrode were carefully studied. The fabricated modified bioelectrode showed good electrocatalytic ability for reduction of H2O2 and trichloroacetic acid (TCA), which shows potential applications in third generation biosensors.  相似文献   

13.
Voltammetric studies of rabbit liver metallothioneins (MTs, containing both Zn and Cd ions) and Zn7‐MT were carried out at Nafion‐coated mercury film electrodes (NCMFEs). The accumulation of MT molecules into the NCMFEs enhances the voltammetric signals and the electrostatic interaction between the Nafion membrane and MT facilitates facile electron transfer reactions. Two well‐defined redox waves, with reduction potential (Epc) values at ?0.740 and ?1.173 V, respectively, were observed. The peak at Epc =?0.740 V is attributable to the reduction of the Cd‐MT complex, whereas that at Epc=?1.173 V was assigned to the reduction of the Zn‐MT complex. Zn7‐MT exhibits only one redox wave with Epc=?1.198 V. The NCMFE was found to be more advantageous than thin mercury film electrode (MFE), because the pristine metal ions in MTs (e.g., Cd2+ and/or Zn2+) are not significantly replaced by Hg2+. The NCMFE is also complementary to Nafion‐coated bismuth film electrode in that it has a greater hydrogen overpotential, which allows the reduction of the Zn‐MT complex to be clearly observed. Moreover, intermetallic compound formation between Cd and Zn appears to be less serious at NCMFEs. Consequently, the amounts of Cd and Zn deposited into the electrode upon the reduction reactions can be quantified more accurately.  相似文献   

14.
A new electrochemical sensor was fabricated via TiO2 nanoparticles onto a carbon paste electrode. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) studied the response of the modified electrode toward codeine. The effects of pH, modifier amount, pulse amplitude, and scan rate of potential have been examined. Using DPV, we could measure simultaneously codeine and acetaminophen in one mixture. The detection limits of 0.018 and 0.050 µmol L?1 were achieved for codeine and acetaminophen, respectively. The electrooxidation pathway, transfer coefficient, and standard rate constant, are estimated. The proposed voltammetric sensor was successfully applied to determination of codeine and acetaminophen in human plasma serum samples.  相似文献   

15.
By incorporation of synthesized magnetite nanoparticles (Fe3O4 NPs) coated with a new Schiff base into carbon paste electrode, a novel modified electrode was constructed for simultaneous determination of ultra trace amounts of Cd(II), Cu(II) and Hg(II). The complexation reaction of Schiff base with metal ions was studied spectrophotometrically. Under optimal conditions a detection limit of 0.20, 0.90 and 1.00 ng mL?1 for Cd(II), Cu(II) and Hg(II), respectively, was obtained. We take the advantages of the proposed method for simple, rapid, sensitive and selective simultaneous determination of trace amounts of hazardous Cd(II), Cu(II) and Hg(II) in water and foodstuff samples.  相似文献   

16.
A new potentiometric sensor for the rapid determination of Hg2+ based on modified carbon paste electrode consisting of room temperature ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), multi-walled carbon nanotubes (MWCNTs), alumina nanoparticles and a synthetic macrocyclic diamide ‘7,10,13-triaza-1-thia-4,16-dioxa-6,14-dioxo-2,3;17,18-dinaphtho-cyclooctadecane’ as an efficient ionophore was constructed. Prepared composite is an ideal paste because it has low drift of potential, high selectivity and fast response time (10 s), which leads to a more stable potential signal. The morphology and properties of electrodes surface were characterised by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy. A linear dynamic range of 2.01–2.01 × 107 µg L?1 with detection limit of 1.40 µg L?1 Hg2+ was obtained at pH range of 2.5 to 4.5. The prepared modified electrode shows several advantages such as simple preparation method, high stability of the composite paste, high sensitivity, long-term life time (at least 13 weeks) and remarkable potentiometric reproducibility. The modified electrode was successfully applied for the accurate determination of trace amounts of Hg 2+ in environmental samples.  相似文献   

17.
Solid-phase nanoextraction is a sample preparation technique, which combines nanotechnology with analytical chemistry, and brings analytical chemistry to a higher level, particularly for complex system analysis. This paper describes a typical example of electrochemical solid-phase nanoextraction and electrochemical detection. Trace amounts of copper (5.0?×?10?13?mol/L) were extracted by electrochemical solid-phase nanoextraction on to the magnesium oxinate nanoparticle-modified carbon paste electrode surface in a pH?7.2 phosphate buffer system at ?0.50 V for 100 s. The extraction is achieved by the cation exchange between copper(II) in the aqueous solution and magnesium(II) from the magnesium oxinate nanoparticles on the electrode surface. The extracted copper shows an irreversible anodic peak at about 0.2 V (vs. saturated calomel electrode). The peak current is proportional to the scan rate, which shows this to be a surface-controlled process. The oxidation peak current is proportional to the logarithm of the copper concentration in the range 5.0?×?10?13?~?5.0?×?10?7?M with a slope of 2.215. This powerful method uses the carbon paste electrode to combine extraction with electrochemical analysis.  相似文献   

18.
A new carbon ionic liquid paste bioelectrode was fabricated by mixing hemoglobin (Hb) with graphite powder, ionic liquid 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) and liquid paraffin homogeneously. Nafion film was cast on the electrode surface to improve the stability of bioelectrode. Direct electrochemistry of Hb in the bioelectrode was carefully investigated. Cyclic voltammetric results indicated that a pair of well‐defined and quasi‐reversible electrochemical responses appeared in pH 7.0 phosphate buffer solution (PBS), indicating that direct electron transfer of Hb was realized in the modified electrode. The formal potential (E0′) was calculated as ?0.316 V (vs. SCE), which was the typical characteristic of the electrochemical reaction of heme Fe(III)/Fe(II) redox couple. Based on the cyclic voltammetric results the electrochemical parameters of the electrode reaction were calculated. This bioelectrode showed high electrocatalytic activity towards the reduction of trichloroacetic acid (TCA) with good stability and reproducibility.  相似文献   

19.
An ionic liquid (IL) 1‐(3‐chloro‐2‐hydroxy‐propyl)‐3‐methylimidazolium trifluoroacetate was used as the modifier for the preparation of the modified carbon paste electrode (CPE). The IL‐CPE showed excellent electrocatalytic activity towards the oxidation of guanosine‐5′‐triphosphate (5′‐GTP) in a pH 5.0 Britton‐Robinson buffer solution. Due to the presence of high conductive IL on the electrode surface, the electrooxidation of 5′‐GTP was greatly promoted with a single well‐defined irreversible oxidation peak appeared. The electrode reaction was an adsorption‐controlled process and the electrochemical parameters of 5′‐GTP on IL‐CPE were calculated with the electron transfer coefficient (α) as 0.44, the electron transfer number (n) as 1.99, the apparent heterogeneous electron transfer rate constant (ks) as 2.21 × 10?9 s?1 and the surface coverage (ΓT) as 1.53 × 10?10 mol cm?2. Under the selected conditions a linear calibration curve between the oxidation peak currents and 5′‐GTP concentration was obtained in the range from 2.0 to 1000.0 μmol L?1 with the detection limit as 0.049 μmol L?1 (3σ) by differential pulse voltammetry. The proposed method showed good selectivity to the 5‘‐GTP detection without the interferences of coexisting substances and the practical application was checked by measurements of the artificial samples.  相似文献   

20.
Bismuth film modified and chemically activated carbon micro‐thread electrodes were investigated for the simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry. The carbon thread electrode was characterised using both surface and electrochemical techniques. Electrochemical impedance spectroscopy (EIS) studies demonstrated that the H2SO4/IPA‐treated carbon thread electrode showed a much improved resistance response (Rct=23 Ω) compared to the IPA‐untreated carbon thread (Rct=8317 Ω). Furthermore, parameters such as the effect of deposition potential, deposition time and Bi(III) concentration were explored using square wave voltammetry. Detection limits (S/N=3) for Cd(II) and Pb(II) were found to be 1.08 µg L?1 and 0.87 µg L?1, respectively and response was found to be linear over the range 5–110 µg L?1. The proposed Bi/IPA‐treated carbon thread electrode exhibited a high selectivity towards Cd(II) and Pb(II) even in the presence of a range of heavy metals and is capable of repetitive and reproducible measurements, being attributed to the high surface area, geometry and electrode treatment characteristics. The proposed metal ion sensor was employed to determine cadmium and lead in river water samples and % RSD was found to be 5.46 % and 5.93 % for Cd(II) and Pb(II) respectively (n=3). Such facile sensing components favour the development of cost effective portable devices for environmental sample analysis and electrochemical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号