首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electrophoresis》2017,38(3-4):513-520
For the development of clinically useful genotyping methods for SNPs, accuracy, simplicity, sensitivity, and cost‐effectiveness are the most important criteria. Among the methods currently being developed for SNP genotyping technology, the ligation‐dependent method is considered the simplest for clinical diagnosis. However, sensitivity is not guaranteed by the ligation reaction alone, and analysis of multiple targets is limited by the detection method. Although CE is an attractive alternative to error‐prone hybridization‐based detection, the multiplex assay process is complicated because of the size‐based DNA separation principle. In this study, we employed the ligase detection reaction coupled with high‐resolution CE‐SSCP to develop an accurate, sensitive, and simple multiplex genotyping method. Ligase detection reaction could amplify ligated products through recurrence of denaturation and ligation reaction, and SSCP could separate these products according to each different structure conformation without size variation. Thus, simple and sensitive SNP analysis can be performed using this method involving the use of similar‐sized probes, without complex probe design steps. We found that this method could not only accurately discriminate base mismatches but also quantitatively detect 37 SNPs of the tp53 gene, which are used as targets in multiplex analysis, using three‐color fluorescence‐labeled probes.  相似文献   

2.
Early detection of pathogens from blood and identification of their drug resistance are essential for sepsis management. However, conventional culture‐based methods require relatively longer time to identify drug‐resistant pathogens, which delays therapeutic decisions. For precise multiplex detection of drug‐resistant Gram‐positive pathogens, we developed a method by using stuffer‐free multiplex ligation‐dependent probe amplification (MLPA) coupled with high‐resolution CE single‐strand conformation polymorphisms (CE‐SSCP) system. We designed three probe sets for genes specific to Gram‐positive species (Staphylococcus aureus: nuc, Enterococcus faecium: sodA, and Streptococcus pneumoniae: lytA) and two sets for genes associated with drug resistance (mecA and vanA) to discriminate major Gram‐positive pathogens with the resistance. A total of 94 different strains (34 reference strains and 60 clinical isolates) were used to validate this method and strain‐specific peaks were successfully observed for all the strains. To improve sensitivity of the method, a target‐specific preamplification step was introduced and, consequently, the sensitivity increased from 10 pg to 100 fg. We also reduced a total assay time to 8 h by optimizing hybridization time without compromising test sensitivity. Taken together, our multiplex detection system can improve detection of drug‐resistant Gram‐positive pathogens from sepsis patients’ blood.  相似文献   

3.
Rapid diagnosis of bacterial infection is important for patient management and appropriate therapy during the early phase of bacteria‐induced disease. Among the existing techniques for identifying microbial, CE‐SSCP combined with 16S ribosomal RNA gene‐specific PCR has the benefits of excellent sensitivity, resolution, and reproducibility. However, even though CE‐SSCP can separate PCR products with high‐resolution, multiplex detection and quantification are complicated by primer‐dimer formation and non‐specific amplification. Here, we describe a novel technique for multiplex detection and quantification of pathogens by template‐tagging followed by multiplex asymmetric PCR and subsequent CE‐SSCP. More specifically, we reverse transcribed 16S ribosomal RNAs from seven septicemia‐inducing pathogens, tagged the templates with common end sequences, and amplified them using common primers. The resulting amplicons could be successfully separated by CE‐SSCP and quantified by comparison to an internal standard. This method yielded results that illustrate the potential of this system for diagnosing infectious disease.  相似文献   

4.
Developing diagnostic tools based on the application of known disease/phenotype‐associated copy number variations (CNVs) requires the capacity to measure CNVs in a multiplex format with sufficient reliability and methodological simplicity. In this study, we developed a reliable and user‐friendly multiplex CNV detection method, termed stuffer‐free MLPA‐CE‐SSCP, that combines a variation of multiplex ligation‐dependent probe amplification (MLPA) with CE‐SSCP. In this variation, MLPA probes were designed without the conventionally required stuffer sequences. To separate the similar‐sized stuffer‐free MLPA products, we adopted CE‐SSCP rather than length‐dependent conventional CE analysis. An examination of the genomic DNA from five cell lines known to vary in X‐chromosome copy number (1–5) revealed that copy number determinations using stuffer‐free MLPA‐CE‐SSCP were more accurate than those of conventional MLPA, and the CV of the measured copy numbers was significantly lower. Applying our system to measure the CNVs on autosomes between two HapMap individuals, we found that all peaks for CNV targets showed the expected copy number changes. Taken together, our results indicate that this new strategy can overcome the limitations of conventional MLPA, which are mainly related to long probe length and difficulties of probe preparation.  相似文献   

5.
Although the resolution of CE‐SSCP has been significantly improved by using a poly(ethyleneoxide)‐poly(propyleneoxide)‐poly(ethyleneoxide) (PEO‐PPO‐PEO; Pluronic®) triblock copolymer as a separation medium, CE‐SSCP on a microchip format is not widely applicable because their resolution is limited by short channel length. Therefore, a strategy to improve the resolution in channels of limited lengths is highly required for enabling microchip‐based CE‐SSCP. In this study, we developed a high‐resolution CE‐SSCP microchip system by controlling the width of the pluronic‐filled channel. We tested four different channel widths of 180, 240, 300, and 400 μm, and found that 300 μm showed the highest resolution in the separation of two pathogen specific markers. Potential applications of our method in various genetic analyses were also shown by using SNP markers for spinal muscular atrophy.  相似文献   

6.
Single nucleotide polymorphisms (SNPs) are one of the most common markers in mammals. Rapid, accurate, and multiplex typing of SNPs is critical for subsequent biological and genetic research. In this study, we have developed a novel method for multiplex genotyping SNPs in mice. The method involves allele‐specific PCR amplification of genomic DNA with two stem‐loop primers accompanied by two different universal fluorescent primers. Blue and green fluorescent signals were conveniently detected on a DNA sequencer. We verified four SNPs of 65 mice based on the novel method, and it is well suited for multiplex genotyping as it requires only one reaction per sample in a single tube with multiplex PCR. The use of universal fluorescent primers greatly reduces the cost of designing different fluorescent probes for each SNP. Therefore, this method can be applied to many biological and genetic studies, such as multiple candidate gene testing, genome‐wide association study, pharmacogenetics, and medical diagnostics.  相似文献   

7.
Although CE‐SSCP analysis combined with 16S ribosomal RNA gene‐specific PCR has enormous potential as a simple and versatile pathogen detection technique, low resolution of CE‐SSCP causes the limited application. Among the experimental conditions affecting the resolution, the polymer matrix is considered to be most critical to improve the resolution of CE‐SSCP analysis. However, due to the peak broadening caused by the interaction between hydrophobic moiety of polymer matrices and DNA, conventional polymer matrices are not ideal for CE‐SSCP analysis. A poly(ethyleneoxide)‐poly(propyleneoxide)‐poly(ethyleneoxide) (PEO‐PPO‐PEO) triblock copolymer, with dynamic coating ability and a propensity to form micelles to minimize exposure of hydrophobic PPO block to DNA, can be an alternative matrix. In this study, we examined the resolution of CE‐SSCP analysis using the PEO‐PPO‐PEO triblock copolymer as the polymer matrix and four same‐sized DNA fragments of similar sequence content. Among 48 commercially available PEO‐PPO‐PEO triblock copolymers, three were selected due to their transparency in the operable range of viscosity and PEO137PPO43PEO137 exhibited the most effective separation. Significant improvement in resolution allowed discrimination of the similar sequences, thus greatly facilitated CE‐SSCP analysis compared to the conventional polymer matrix. The results indicate that PEO‐PPO‐PEO triblock copolymer may serve as an ideal matrix for high‐resolution CE‐SSCP analysis.  相似文献   

8.
Rapid and simple analysis for the multiple target pathogens is critical for patient management. CE‐SSCP analysis on a microchip provides high speed, high sensitivity, and a portable genetic analysis platform in molecular diagnostic fields. The capability of separating ssDNA molecules in a capillary electrophoretic microchannel with high resolution is a critical issue to perform the precise interpretation in the electropherogram. In this study, we explored the potential of poly(ethyleneoxide)‐poly(propyleneoxide)‐poly(ethyleneoxide) (PEO‐PPO‐PEO) triblock copolymer as a sieving matrix for CE‐SSCP analysis on a microdevice. To demonstrate the superior resolving power of PEO‐PPO‐PEO copolymers, 255‐bp PCR amplicons obtained from 16S ribosomal RNA genes of four bacterial species, namely Proteus mirabilis, Haemophilus ducreyi, Pseudomonas aeruginosa, and Neisseria meningitidis, were analyzed in the PEO‐PPO‐PEO matrix in comparison with 5% linear polyacrylamide and commercial GeneScan? gel. Due to enhanced dynamic coating and sieving ability, PEO‐PPO‐PEO copolymer displayed fourfold enhancement of resolving power in the CE‐SSCP to separate same‐sized DNA molecules. Fivefold input of genomic DNA of P. aeruginosa and/or N. meningitidis produced proportionally increased corresponding amplicon peaks, enabling correct quantitative analysis in the pathogen detection. Besides the high‐resolution sieving capability, a facile loading and replenishment of gel in the microchannel due to thermally reversible gelation property makes PEO‐PPO‐PEO triblock copolymer an excellent matrix in the CE‐SSCP analysis on the microdevice.  相似文献   

9.
A simple and precise diagnostic method for spinal muscular atrophy (SMA) using high‐resolution CE‐based single‐strand conformation polymorphism (CE‐SSCP) was developed in this study. SMA is a common genetic disorder caused by an abnormality in the relative copy numbers of SMN1 and its centromeric copy SMN2, which differ only in two nucleotides, namely at exons 7 and 8. Therefore, the precise discrimination of the differences in sequence as well as their relative quantities is crucial for the diagnosis of SMA. Multiplex ligation‐dependent probe amplification and sequence‐sensitive DNA separation using hydroxyethyl cellulose and hydroxypropyl cellulose blended polymer matrix are currently the available methods used in the diagnosis of SMA. However, these methods are limited by their extended hybridization step and low resolution. In this study, the simultaneous discrimination of SMN exons 7 and 8 was successfully demonstrated using high‐resolution CE‐SSCP. Unlike the previously reported alternative method, single base differing amplicons were baseline‐separated because of its extraordinary resolution, thus providing accurate and precise quantification of each paralog.  相似文献   

10.
Pluronic F108 block copolymers have shown a great promise to achieve the desirable high resolution in the conformation‐sensitive separation of ssDNA using CE‐SSCP. However, fundamental understanding of the structures and properties of Pluronic matrix affecting the resolution is still limited. Unlike conventional gel‐forming homopolymers, Pluronic F108 block copolymers are amphiphilic macromolecules consisting of poly(ethylene oxide)‐b‐poly(propylene oxide)‐b‐poly(ethylene oxide) triblock copolymers, which are capable of forming a highly ordered micellar structure in aqueous solution. In this study, we have performed a series of experiments by blending different types of Pluronic polymers to control the formation of micelles and to study the correlation between separation and rheological characteristics of Pluronic gels affecting the resolution of CE‐SSCP. Our experiments have been specifically designed to elucidate how the micellar structure affects the resolution of CE‐SSCP upon altering the size uniformity and constituent homogeneity of the micelles. Our results suggest that uniformly sized micelle packing is the primary structural feature of Pluronic gel matrix for the high‐resolution separation, while the size and constituent of the micelle themselves need to be considered as secondary factors.  相似文献   

11.
Antibody‐conjugated magnetic nanoparticles (Ab‐MNPs) have potential in pathogen detection because they allow target cells to be easily separated from complex sample matrices. However, the sensitivity and specificity of pathogen capture by Ab‐MNPs generally vary according to the types of MNPs, antibodies, and sample matrices, as well as preparation methods, including immobilization. Therefore, achieving a reproducible analysis utilizing Ab‐MNPs as a pathogen detection method requires accurate characterization of Ab‐MNP capture ability and standardization of all handling processes. In this study, we used high‐resolution CE‐single strand conformational polymorphism coupled with a stuffer‐free multiplex ligation‐dependent probe amplification system to characterize Ab‐MNPs. The capture ability of Ab‐MNPs targeting Salmonella enteritidis and nine pathogens, including S. enteritidis, was analyzed in phosphate buffer and milk. The effect of storage conditions on the stability of Ab‐MNPs was also assessed. The results showed that the stuffer‐free multiplex ligation‐dependent probe amplification system has the potential to serve as a standard characterization method for Ab‐MNPs. Moreover, the precise characterization of Ab‐MNPs facilitated robust pathogen detection in various applications.  相似文献   

12.
CE‐SSCP analysis is a well‐established DNA separation method that is based on variations in mobility caused by sequence‐induced differences in the conformation of single‐stranded DNA. The resolution of CE‐SSCP analysis was improved by using a Pluronic polymer matrix, and it has been successfully applied in various genetic analyses. Because the Pluronic polymer forms a micellar cubic structure in the capillary, it provides a stable internal structure for high‐resolution CE‐SSCP analysis. We hypothesized that formation of micellar cubic structure is influenced by the end hydroxyl group of the Pluronic polymer, which affords structural stability through hydrogen bonding. To test this hypothesis, the hydroxyl group was halogenated to eliminate the hydrogen bonding without disturbing the polarity of polymer matrix. CE‐SSCP resolution of two DNA fragments with a single base difference was significantly worse in the halogenated polymer matrices due to band broadening. The viscoelastic properties of control (which has hydroxyl group), chlorinated, and brominated F108 solution upon heating were also investigated by rheological experiments, and we found that gelation was significantly associated with resolution. In this series of experiments, the effect of the hydroxyl group in Pluronic polymer matrix on separation resolution of CE‐SSCP analysis was demonstrated.  相似文献   

13.
Lower respiratory tract infection is one of the most common infectious diseases. However, conventional methods for detecting infectious pathogens are time‐consuming, and generally have a limited impact on early therapeutic decisions. We previously reported a rapid and sensitive method for detecting such pathogens using stuffer‐free multiplex ligation‐dependent probe amplification coupled with high‐resolution CE‐SSCP. In this study, we report an application of this method to the detection of respiratory pathogens. As originally configured, this method was capable of simultaneously detecting seven bacterial species responsible for lower respiratory tract infections, but its detection limit and assay time were insufficient to provide useful information for early therapeutic decisions. To improve sensitivity and shorten assay time, we added a target‐specific preamplification step, improving the detection limit from 50 pg of genomic DNA to 500 fg. We further decreased time requirements by optimizing the hybridization step, enabling the entire assay to be completed within 7 h while maintaining the same detection limit. Taken together, these improvements enable the rapid detection of infectious doses of pathogens (i.e. a few dozen cells), establishing the strong potential of the refined method, particularly for aiding early treatment decisions.  相似文献   

14.
15.
RNA viruses display the highest replication error rate in our biosphere, leading to highly diverse viral populations termed quasispecies. The gold standard method for detection and quantification of variants in a quasispecies is cloning and sequencing, but it is expensive, laborious and time consuming. Therefore, other mutation detection approaches, including SSCP, are often used. In this study, we demonstrate development and the usage of a CE‐SSCP method for quantification of two nearly identical viral variants in heterogenic population of a mumps virus strain and its comparison to RFLP‐CE‐fragment length analysis (RFLP‐CE‐FLA). Analyzed PCR fragments were of the same size (245 bp) with one difference in their nucleotide sequence. The limit of detection of both methods was at 5% of the minor variant. When PCR amplicons of the two variants were pooled, methods' results were very similar. On the contrary, the quantification results of samples in which variants were mixed prior to PCR showed substantial difference between the two methods. Our results indicate that although both methods can be used for detection and monitoring of a specific mutation within a viral population, caution should be taken when quantitative analysis of complex samples is based solely on results of one method.  相似文献   

16.
A 2‐D‐HPLC/CE method was developed to separate and characterize more in depth the phenolic fraction of olive oil samples. The method involves the use of semi‐preparative HPLC (C18 column 250×10 mm, 5 μm) as a first dimension of separation to isolate phenolic fractions from commercial extra‐virgin olive oils and CE coupled to TOF‐MS (CE‐TOF‐MS) as a second dimension, to analyze the composition of the isolated fractions. Using this method, a large number of compounds were tentatively identified, some of them by first time, based on the information concerning high mass accuracy and the isotopic pattern provided by TOF‐MS analyzer together with the chemical knowledge and the behavior of the compounds in HPLC and CE. From these results it can be concluded that 2‐D‐HPLC‐CE‐MS provides enough resolving power to separate hundreds of compounds from highly complex samples, such as olive oil. Furthermore, in this paper, the isolated phenolic fractions have been used for two specific applications: quantification of some components of extra‐virgin olive oil samples in terms of pure fractions, and in vitro studies of its anti‐carcinogenic capacity.  相似文献   

17.
Keratin‐associated proteins (KAPs) are one of the main structural components of the wool fibre. Variation in the KAP genes (KRTAPs) may affect the structure of KAPs and hence wool characteristics. In this study, we used PCR‐SSCP to analyse ovine KRTAP5‐4, a gene encoding a member of the KAP5 family. Five different PCR‐SSCP patterns were detected in the 250 sheep that were analysed. Either one or a combination of two patterns was observed for each sheep, which was consistent with these sheep being either homozygous or heterozygous at this locus. DNA sequencing revealed that these patterns represent five different DNA sequences. One of the sequences was identical to a published ovine KRTAP5‐4 sequence. The remaining four were unique, but shared a high homology with the published ovine KRTAP5‐4 sequence, suggesting that these sequences represent allelic variants of KRTAP5‐4. There were a total of six SNPs and one length polymorphism in the sequences. Of the five SNPs found in the coding region, four were non‐synonymous SNPs and would result in amino acid changes. The length polymorphism would affect the cysteine content of the putative peptide and this along with the SNPs may have an impact on the structure of KAP5‐4, and hence affect wool traits.  相似文献   

18.
One rapid CE method was established to diagnose Duchenne muscular dystrophy (DMD). DMD is a severe recessive inherited disorder frequently caused by gene deletions. Among them, exons 1–20 account for nearly 30% of occurrences. In this study, the universal multiplex PCR was used to enhance the fluorescently labeling efficiency, which was performed only by one universal fluorescent primer. After PCR, a short‐end injection CE (short‐end CE) speeded up the genotyping of the DMD gene. This method involved no extra purification, and was completed within 9 min. The CE conditions contained a polymer solution of 1.5% hydroxylethylcellulose in 1× TBE buffer at 6 kV for separation. This method was applied to test six DMD patients and one healthy male person. The results showed good agreement with those of multiplex ligation‐dependent probe amplification. This method can be applied for clinical diagnosis of DMD disease. Accurate diagnosis of the DMD gene is the best way to prevent the disease.  相似文献   

19.
Due to their important biological role as markers for different pathologies, sialic acid (SA) analyses are important for clinical research. In this work, a miniaturized capillary electrophoresis with amperometric detection (mini‐CE‐AD) was developed for the determination of N‐acetylneuraminic acid (NANA), which is the most widespread form of SAs. NANA was first oxidized by periodic acid in an acidic solution, and then the oxidation product β‐formyl pyruvic acid was derivatized with electroactive 2‐thiobarbituric acid (TBA) to form an electroactive NANA‐TBA adduct, which could be readily determined by mini‐CE‐AD. The limit of detection (LOD) of NANA‐TBA could achieve 0.50 µg/mL (1.6 µmol·L?1, S/N=3) based on an online enrichment approach of moving chemical reaction boundary. The proposed method was successfully applied to the analysis of NANA in human saliva, and the recoveries were in the range of 91.8% –109% with RSDs of 1.8% –3.9%. Due to its simple design and construction, low cost and portability, the mini‐CE‐AD device will possess more practicability in more field work as an alternative to conventional and microchip CE approaches.  相似文献   

20.
Two single nucleotide polymorphisms (SNPs) of 5,10-methylenetetrahydrofolate reductase (MTHFR) gene, A1298C and C677T, were widely considered to be related with various neoplasia disorders. We established a simple and effective capillary electrophoresis (CE) method for detection of two SNPs in MTHFR gene simultaneously. DNA samples were amplified by multiplex PCR with universal fluorescence-labeled primer and analyzed by single-strand conformation polymorphism (SSCP)-CE method. The CE method was performed using 1.5% hydroxyethyl cellulose in 1× TBE buffer containing 1 M urea. The PCR products after SSCP procedure were electrokinetically injected at −10 kV, 30 s. Separation voltage was −6 kV and the temperature was set at 20 °C. The optimal SSCP-CE method was applied to detect two polymorphisms in MTHFR gene of acute lymphoblastic leukemia (ALL) and attention-deficit/hyperactivity disorder (ADHD) patients. Genotyping results were evaluated in terms of relationships between outcomes for ADHD patients after ALL chemotherapy and ALL disease. The SSCP-CE method and multiplex PCR with universal fluorescence primer were used as the fast technique for screening two SNPs in MTHFR gene, A1298C and C677T. The genotyping data were coincident with DNA sequencing. This SSCP-CE method was found feasible for detecting mutation of MTHFR gene in populations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号