首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

2.
D. Sircar  G. Dey  A. Mitra 《Chromatographia》2007,65(5-6):349-353
A reverse phase HPLC method was developed and validated for the simultaneous determination of 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid in the root extracts of Hemidesmus indicus. A comprehensive validation of the method including sensitivity, linearity, reproducibility, accuracy, limit of detection (LOD) and limit of quantification (LOQ) was conducted using the optimized chromatographic conditions. The method was found to be linear (r > 0.998) in the range of 5–350 μg mL−1 for 2-hydroxy-4-methoxybenzaldehyde and for 2-hydroxy-4-methoxybenzoic acid (r > 0.999) in the range 10–300 μg mL−1. The method was found to be precise with inter-day precision values (% RSD) in the ranges of 0.61–1.76% for 2-hydroxy-4-methoxybenzaldehyde and 1.3–2.8% for 2-hydroxy-4-ethoxybenzoic acid while intra-day precisions (% RSD) of two analytes were in the range of 0.41–1.07 and 0.95–2.5%. The limits of detection (LODs) for 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid were 0.84 and 2.34 μg mL−1. The described method was fast, sensitive and reproducible, and thus well suited for routine analysis of these two compounds from root extracts of H. indicus and other plants.  相似文献   

3.
A sensitive semi-micro column HPLC method with peroxyoxalate chemiluminescence (POCL) detection and column switching has been developed for simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA) and related compounds, for example 3,4-methylenedioxyamphetamine, methamphetamine, and amphetamine, in hair. After digestion of the hair with 1 mol L−1 sodium hydroxide the compounds were extracted with n-heptane and derivatized with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole. A mixture of hydrogen peroxide and bis(2,4,5-trichloro-6-carbopentoxyphenyl)oxalate in acetonitrile was used as post-column CL reagent. Calibration plots showed linearity was good (r = 0.999); detection limits were 0.02–0.16 ng mg−1 hair at a signal-to-noise ratio of 3. The precision of the method, as RSD (n = 5), in intra-day and inter-day assays was better than 5.0 and 6.9%, respectively. The proposed method was sufficiently sensitive to detect low ng mg−1 levels of MDMA and related compounds in hair, and could be used for quantification of the compounds in hair samples from patients treated in a chemical dependency unit.  相似文献   

4.
S. Tatar Ulu 《Chromatographia》2006,64(7-8):447-451
A simple, selective, precise and accurate reversed phase-HPLC assay for analysis of gemfibrozil in tablets was developed and validated. Separation and quantification were achieved on a Phenomenex C18 column under isocratic conditions using a mobile phase (methanol:water, 80:20, v/v) maintained at 1.1 mL min−1. UV-detection was at 280 nm. Atorvastatin was selected as an internal standard. The standard curves were linear over the range of 0.5–3.0 μg mL−1 (r > 0.999). The limits of detection and quantification were 0.20 and 0.51 μg mL−1, respectively. The recoveries for gemfibrozil were above 99.01%. The intra-day and inter-day precision (RSD) for gemfibrozil were below 1.74 and 1.83%, respectively. No chromatographic interferences from the tablet excipients were found. The results of the developed procedure in tablets were compared with those of the reference method to assess gemfibrozil content. Statistical comparison of the results with the reference method using spectrofluorimetric method showed excellent agreement and proved no significant difference in accuracy and precision. This HPLC method is fast and simple for the analysis of gemfibrozil in pharmaceutical preparations.  相似文献   

5.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

6.
Summary A high-performance liquid-chromatographic method is described for the quantitative determination of the mycotoxin ochratoxin A (OTA) in human plasma. The assay involves extraction with chloroform and sodium bicarbonate then HPLC with fluorescence detection. The method was validated in terms of selectivity, recovery, linearity, precision (within-day and between-day variability), accuracy, detection and quantification limits, and the stability of OTA in plasma and treated samples. The limit of detection was 0.4 ng mL−1 of OTA in methanol, corresponding to 0.52 ng ml−1 OTA in plasma. This assay was successfully applied for the determination of OTA levels in human plasma.  相似文献   

7.
A validated, highly sensitive, and selective HPLC method with MS–MS detection has been developed for quantitative determination of azithromycin (AZI) in human Na2EDTA plasma. Roxithromycin (ROX) was used as internal standard. Human plasma containing AZI and internal standard was ultrafiltered through Centrifree Micropartition devices and the concentration of AZI was determined by isocratic HPLC–MS–MS. Multiple reaction monitoring mode (MRM) was used for MS–MS detection. The calibration plot was linear in the concentration range 2.55–551.43 ng mL−1. Inter-day and Intra-day precision and accuracy of the proposed method were characterized by R.S.D and percentage deviation, respectively; both were less than 8%. Limit of quantification was 2.55 ng mL−1. The proposed method was used to determine the pharmacokinetic profile of AZI (250-mg tablets).  相似文献   

8.
A fast and validated assay was established for the pharmacokinetic study of amygdalin in Armeniacae Semen in rabbit. The method involved column switching (CS) enrichment, separation, post-column derivatization, and atmospheric pressure chemical ionization (APCI) mass spectrometric detection. Plasma sample was enriched by CS using a MAYI-ODS as the first column. Analytes of interest were isolated and analyzed on a second column of Zorbax SB-C18. To detect amygdalin in plasma samples, a T-piece was connected between the HPLC outlet and the APCI source to add a mixture of dichloromethane and methanol to the eluent by an isocratic pump. Calibration graphs showed good linearity over a range of 1.0–1,280 ng mL−1. The detection limit was 0.2 ng mL−1. The intra- and inter-day accuracies were within 3.9%. The method was successfully applied to a study of the pharmacokinetics of amygdalin after an intravenous injection of amygdalin extracts to rabbits with a dose of 400 mg kg−1. The results indicate that amygdalin is a one-compartment open model with a first order absorption phase.  相似文献   

9.
Summary A method for the determination of the food mutagen 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) in human hair has been developed and validated. Hair samples (200 mg) were dissolved in NaOH (1 M) and PhIP was isolated by successive solid-phase extraction on a polystyrene-divinylbenzene column and on a silica-based mixed-mode column with C8 and-SO3 functional groups. Quantification was performed by gas chromatography-electron-impact ionization high-resolution mass spectrometry in selected-ion-monitoring mode. The method was validated for determination of PhIP in the concentration range 0.5–25 ng g−1 hair with [2H3]PhIP as internal standard. The limit of quantification was 0.26 ng g−1 hair. Within-day and between-day precision were in the ranges 1–27% and 2–15% relative standard deviation, respectively. The hair sample used for method validation was found to contain 0.26 ng PhIP g−1 hair.  相似文献   

10.
Summary An HPLC method was developed for determination of amoxicillin, penicillin G, penicillin V, ampicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in serum from pigs and cattle. Serum was cleaned up by solid-phase extraction (SPE), ultra-filtered and derivatised. The method was linear in the range tested up to 2000 ng mL−1 of individual penicillins in serum. Limits of detection were 11–14 ng mL−1. Mean recoveries were 90–103% in the range 20–2000 ng mL−1. The relative repeatability, standard deviation was <10% at 20 ng mL−1 level and <6% in the range 100–2000 ng mL−1.  相似文献   

11.
Radix Scrophulariae (Xuanshen) is one of the famous Chinese herbal medicines widely used to treat rheumatism, tussis, pharyngalgia, arthritis, constipation, and conjunctival congestion. Harpagoside and cinnamic acid are the main bioactive components of Xuanshen. The purpose of this study was to develop an HPLC–UV method for simultaneous determination of harpagoside and cinnamic acid in rat plasma and investigate pharmacokinetic parameters of harpagoside and cinnamic acid after oral administration of Xuanshen extract (760 mg kg−1). After addition of syringin as internal standard, the analytes were isolated from plasma by liquid–liquid extraction. Separation was achieved on a Kromasil C18 column, and detection was by UV absorption at 272 nm. The described assay was validated in terms of linearity, accuracy, precision, recovery, and limit of quantification according to the FDA validation guidelines. Calibration curves for both analytes were linear with the coefficient of variation (r) for both was greater than 0.999. Accuracy for harpagoside and cinnamic acid ranged from 100.7–103.5% and 96.9–102.9%, respectively, and precision for both analytes were less than 8.5%. The main pharmacokinetic parameters found for harpagoside and cinnamic acid after oral infusion of Xuanshen extract were as follows: C max 1488.7 ± 205.9 and 556.8 ± 94.2 ng mL−1, T max 2.09 ± 0.31 and (1.48 ± 0.14 h, AUC0–24 10336.4 ± 1426.8 and 3653.1 ± 456.4 ng h mL−1, 11276.8 ± 1321.4 and 3704.5 ± 398.8 ng h mL−1, and t 1/2 4.9 ± 1.3 and 2.5 ± 0.9 h, respectively. These results indicated that the proposed method is simple, selective, and feasible for pharmacokinetic study of Radix Scrophulariae extract in rats. Figure Radix Scrophulariae  相似文献   

12.
A simple, isocratic, normal phase chiral HPLC method was developed and validated for the enantiomeric separation of repaglinide, (S)-(+)-2-ethoxy-4-N [1-(2-piperidinophenyl)-3-methyl-1-butyl] aminocarbonylmethyl] benzoic acid, an antidiabetic in bulk drug substance. The enantiomers of repaglinide were resolved on a ChiralPak AD-H (amylose based stationary phase) column using a mobile phase consisting of n-hexane: 2-propanol:trifluoroacetic acid (95:5:0.2 v/v/v) at a flow rate of 1.0 mL min−1. The resolution between the enantiomers was found to be not >3.5 in optimized method. The presence of trifluoroacetic acid in the mobile phase played an important role, in enhancing chromatographic efficiency and resolution between the enantiomers. The developed method was extensively validated and proved to be robust. The calibration curve for (R)-enantiomer showed excellent linearity over the concentration range of 900 ng mL−1 (LOQ) to 6,000 ng mL−1. The limit of detection and limit of quantification for (R)-enantiomer were 300 and 900 ng mL−1, respectively. The percentage recovery of the (R)-enantiomer ranged between 98.3 and 101.05% in bulk drug samples of repaglinide. Repaglinide sample solution and mobile phase were found to be stable up to 48 h. The developed method was found to be enantioselective, accurate, precise and suitable for quantitative determination of (R)-enantiomer in bulk drug substance.  相似文献   

13.
A simple and sensitive reversed-phase LC-ESI-MS method to identify and quantitate 5-n-butyl-4-{4-[2-(1H-tetrazole-5-yl)-1H-pyrrol-1-yl]phenylmethyl}-2,4-dihydro-2-(2,6-dichloridephenyl)-3H-1,2,4-triazol-3-one (1b), a new Angiotensin II type 1 receptor antagonist in rat plasma has been developed and validated. Sample preparation used a simple liquid–liquid extraction with ethyl acetate. Separation was achieved by gradient elution on a C18 column. The mobile phase consisted of acetonitrile and water (0.05% triethylamine and 0.05% acetic acid) at a flow rate of 0.2 mL min−1. The detection utilized selected ion monitoring (SIM) in the negative mode at m/z 507.1 and m/z 407.2 for the deprotonated molecular ions of 1b and the internal standard irbesartan, respectively. The lower limit of quantification was reproducible at 5 ng mL−1 with 100 μL of plasma and the good linear was observed in the 5–500 ng mL−1 range. This concentration range corresponded well with the plasma concentrations of 1b in pharmacokinetic studies. Recoveries of 1b in rat plasma were 76.1, 74.6 and 79.0% at 5, 50 and 500 ng mL−1. The RSD of intra-assay and inter-assay variations were all less than 5%. This validated LC-ESI-MS assay is an economic, quick, precise and reliable method for the analysis of 1b in pharmacokinetic studies.  相似文献   

14.
Two rapid and popular methods—capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) have been compared for analysis of cotinine in human urine. Cotinine was analyzed in less than 7 min, with detection limits of 5 and 3.2 ng mL−1 for CE and HPLC, respectively. The performance of the methods was evaluated in terms of sensitivity, specificity, precision, accuracy, and limits of detection and quantification. Calibration plots were linear in the range 50–4,000 ng mL−1, at least, and mean recoveries were satisfactory for both techniques. The methods were successfully used for quantification of cotinine in urine.  相似文献   

15.
A sensitive and rapid liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the determination of mizolastine in human plasma using dipyridamole as the internal standard (I.S.). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on an Agilent Zorbax C18 column with a mobile phase of 10 mM ammonium acetate buffer containing 0.1% formic acid–methanol (20:80, v/v) at a flow rate of 1 mL min−1. The electrospray ionization (ESI) interface was employed in a single quadrupole mass spectrometer. The analytes were protonated in the positive ESI interface and detected in single ion monitoring (SIM) mode. Chromatographic separation was achieved in less than 3.5 min. The linearity was established over the range of 0.5–600 ng mL−1. The lower limited of quantification (LLOQ) of the method was 0.5 ng mL−1. The intra- and inter-run standard deviations were both less than 11.2%. The method was applied to study the pharmacokinetics of the mizolastine sustained-release tablets in healthy volunteers.  相似文献   

16.
(E)-3,5,4′-trimethoxystilbene (BTM-0512) is a resveratrol analog with a variety of pharmacological action, including anti-cancer properties, anti-allergic activity, estrogenic activity, antiangiogenic activity, and vascular-targeting activity against microtubule-destabilization. There is, however, no validated analytical method for quantification of (E)-3,5,4′-trimethoxystilbene in biological matrices, so pharmacokinetic data and suitable methods for determination of the compound in plasma are currently lacking. A rapid and sensitive liquid chromatographic–mass spectrometric method for determination of (E)-3,5,4′-trimethoxystilbene in rat plasma, using carbamazepine as internal standard, has been developed and validated. Plasma samples were treated with acetonitrile to precipitate proteins. Samples were then analyzed by HPLC on a 250mm × 4.6 mm i.d., 5-μm particle, C18 column with methanol–water, 80:20 (v/v), containing 10 mm ammonium acetate and 0.2% formic acid (pH 3.0), as mobile phase, delivered at 0.85 mL min−1. A single-quadrupole mass spectrometer with an electrospray interface operated in selected-ion monitoring mode was used to detect [M + H]+ ions at m/z 271.3 for (E)-3,5,4′-trimethoxystilbene and m/z 237.5 for the internal standard. (E)-3,5,4′-trimethoxystilbene and the internal standard eluted as sharp, symmetrical peaks with retention times of 8.9 and 4 min, respectively. Calibration plots for (E)-3,5,4′-trimethoxystilbene in rat plasma at concentrations ranging from 0.01 to 5.0 μg mL−1 were highly linear. Intra-day and inter-day precision, as RSD, was <12.9%, and accuracy was in the range 94.8–104.7%. The limit of detection in plasma was 0.005 μg mL−1. The method was successfully used to determine the concentration of (E)-3,5,4′-trimethoxystilbene after oral administration of 86 mg kg−1 of the drug to Sprague–Dawley rats and can be used to investigate the pharmacokinetics of the compound.  相似文献   

17.
A new methodology was developed for analysis of aldehydes and ketones in fuel ethanol by high-performance liquid chromatography (HPLC) coupled to electrochemical detection. The electrochemical oxidation of 5-hydroxymethylfurfural, 2-furfuraldehyde, butyraldehyde, acetone and methyl ethyl ketone derivatized with 2,4-dinitrophenylhydrazine (DNPH) at glassy carbon electrode present a well defined wave at +0.94 V; +0.99 V; +1.29 V; +1.15 V and +1.18 V, respectively which are the basis for its determination on electrochemical detector. The carbonyl compounds derivatized were separated by a reverse-phase column under isocratic conditions with a mobile phase containing a binary mixture of methanol / LiClO4(aq) at a concentration of 1.0 × 10−3 mol L−1 (80:20 v/v) and a flow-rate of 1.1mL min−1 . The optimum potential for the electrochemical detection of aldehydes-DNPH and ketones-DNPH was +1.0 V vs. Ag/AgCl. The analytical curve of aldehydes-DNPH and ketones-DNPH presented linearity over the range 5.0 to 400.0 ng mL−1, with detection limits of 1.7 to 2.0 ng mL−1 and quantification limits from 5.0 to 6.2 ng mL−1, using injection volume of 20 μL. The proposed methodology was simple, low time-consuming (15 min/analysis) and presented analytical recovery higher than 95%.  相似文献   

18.
Ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS–MS) has been used for screening and quantification of 32 pesticides and metabolites in two fruit matrices. The compounds investigated belonged to different chemical families of insecticides, acaricides, fungicides, and herbicides; several metabolites were also included. Quantification was conducted using matrix-matched standards calibration; response was a linear function of concentration in the range tested (10–500 ng mL−1). The method was validated with blank samples of lemon and raisin spiked at 0.01 and 0.1 mg kg−1, and recoveries were satisfactory, between 70 and 110%, for most of the pesticides tested and relative standard deviations were below 15% (n = 5 at each spiking level). Excellent sensitivity resulted in limits of detection for all compounds well below 0.01 mg kg−1, with the limit of quantification being validated at 0.01 mg kg−1. The UPLC system generates narrow peaks (approx. 5 s), thus increasing peak height and improving sensitivity. This improved separation efficiency facilitates adequate resolution not only of the analytes but also of matrix interferences compared with conventional HPLC. The method developed could also resolve some geometric isomers. The main advantage of this approach is the high sample throughput achieved because of the short analysis time, which enables satisfactory separation of all the compounds in less than 5 min per sample.  相似文献   

19.
Summary A simple, low-cost, sensitive and selective HPLC method was developed for the determination of phenazopyridine in human plasma. The method employs UV detection of phenazopyridine and of the internal Standard at 2 different wavelengths. Calibration curves were linear over a large dynamic range, i.e., within 0.05–10.0 μg mL−1 with limit of quantification of 0.05 μg mL−1, and a limit of detection of 0.01 μg mL−1.  相似文献   

20.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏