首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The use of hydrophilic interaction liquid chromatography (HILIC) in food analysis in the last decade is reviewed. The HILIC mechanism is briefly discussed, but main emphasis is put on the use of HILIC for separation of different food matrices. The food matrices are divided into food of animal origin and related products, vegetables, fruits and related compounds, and other food-related matrices. A list on important applications is provided for each category including experimental conditions and a brief summary of the results. The 100 references included will provide the reader a comprehensive overview and insight into HILIC applications to food analysis.  相似文献   

2.
Guo Y  Yuan Q  Li R  Huang Y 《色谱》2012,30(3):232-238
亲水作用色谱(HILIC)是一种分离极性和亲水性化合物的液相色谱模式,其作为反相液相色谱(RPLC)的重要补充,近年来越来越受到各个领域的关注和重视。这不只是因为强极性化合物的分离问题在各个领域引起了重视,而且因为与RPLC比较,HILIC具有流动相组成黏度低、色谱柱渗透性好、与质谱联用的灵敏度高及反压较低等优势。本文简要概述了HILIC的发展历程、特点及保留机理,重点介绍了HILIC用于环境分析的最新进展,评述了HILIC及RPLC用于污染物分析的优缺点,并指出了HILIC用于环境分析的未来发展趋势。  相似文献   

3.
There has been a significant increase of interest in polar compound separation by hydrophilic interaction liquid chromatography (HILIC), in which acetonitrile is mostly used as a weak eluent. Although replacing acetonitrile with alcohols as organic modifiers has been previously reported, the separation mechanism was poorly understood. In this paper we explored the separation mechanism through the method development for the analysis of the trace amounts of polar and basic hydrazines, which were genotoxic in nature. Separation parameters such as the type and concentration of alcohol, acid modifier, and buffer in mobile phase as well as the choice of stationary phase and column temperature were studied. The data indicated that both electrostatic and hydrophilic interactions contributed to the retention and separation of the hydrazines. The results presented here provide insight into the adjustment of the retention and separation of analytes in HILIC mode with alcohol as a weak eluent. The optimized HILIC method coupled with chemiluminescent nitrogen detection (CLND) is simple and sensitive (reporting limit at 0.02%) and was applied to simultaneous analysis of hydrazine and 1,1-dimethylhydrazine in a pharmaceutical intermediate.  相似文献   

4.
In proteomics, nanoflow multidimensional chromatography is now the gold standard for the separation of complex mixtures of peptides as generated by in-solution digestion of whole-cell lysates. Ideally, the different stationary phases used in multidimensional chromatography should provide orthogonal separation characteristics. For this reason, the combination of strong cation exchange chromatography (SCX) and reversed-phase (RP) chromatography is the most widely used combination for the separation of peptides. Here, we review the potential of hydrophilic interaction liquid chromatography (HILIC) as a separation tool in the multidimensional separation of peptides in proteomics applications. Recent work has revealed that HILIC may provide an excellent alternative to SCX, possessing several advantages in the area of separation power and targeted analysis of protein post-translational modifications. Figure Artistic impression of the HILIC separation mechanism  相似文献   

5.
A hydrophilic interaction liquid chromatography (HILIC) method was developed to measure the composition of humic substances from river, reservoir, and treated wastewater based on their physicochemical properties. The current method fractionates the humic substances into four well-defined groups based on parallel analyses with a neutral and a cationic HILIC column, using mobile phases of varied compositions and pH. The results indicate that: (i) the proportion of carboxylic acids in the humic substances from terrestrial origins is less than half of that from treated wastewater (Jeddah, KSA), (ii) a higher content of basic compounds was observed in the humic substances from treated wastewater and Ribou Reservoir (Cholet, France) than in the sample from Loire River (France), (iii) a higher percentage of hydrophobic macromolecules were found in the humic substances from Loire River than in the other samples, and (iv) humic substances of treated wastewater contained less ionic neutral compounds (i.e., pKa 5–9) than the waters from terrestrial origins. The physicochemical property disparity amongst the compounds in each humic substances sample was also evaluated. The humic substances from the lightly humic Loire river displayed the highest disparity, whereas the highly humic Suwannee river (Georgia, USA) showed the most homogeneous humic substances.  相似文献   

6.
亲水作用液相色谱法(HILIC)是一种用于改善强极性物质的保留和分离选择性的方法,广泛应用于药物分析、代谢组学、蛋白质组学等领域.该文利用农药分子与皂苷成分在HILIC上的保留行为差异,开发了一种农药残留脱除方法.以市售高纯人参提取物为例,该文评价了农药分子和人参皂苷在亲水色谱柱上的保留行为,并考察了上样量、淋洗体积、...  相似文献   

7.
Eight deoxynucleoside triphosphates (dNTPs) and nucleoside triphosphates (NTPs): ATP, CTP, GTP, UTP, dATP, dCTP, dGTP and dTTP, were separated with two 15 cm ZIC-pHILIC columns coupled in series, using LC-UV instrumentation. The polymer-based ZIC-pHILIC column gave significantly better separations and peak shape than a silica-based ZIC-HILIC column. Better separations were obtained with isocratic elution as compared to gradient elution. The temperature markedly affected the selectivity and could be used to fine tune separation. The analysis time was also affected by temperature, as lower temperatures surprisingly reduced the retention of the nucleotides. dNTP/NTP standards could be separated in 35 min with a flow rate of 200 μL/min. In Escherichia coli cell culture samples dNTP/NTPs could be selectively separated in 7 0min using a flow rate of 100 μL/min.  相似文献   

8.
In this study, the analysis of a peptide set, chosen for their differences in hydrophilicity, and the tryptic digests of bovine cytochrome c and β-lactoglobulin by hydrophilic interaction chromatography–electrospray ionisation mass spectrometry (HILIC–ESI-MS) is demonstrated. Two different types of HILIC phases, i.e., an amide- and an amino-modified silica-based phase, packed into narrow bore or capillary columns, were investigated with separations conducted under either low pH or neutral pH conditions. The separation performance of the two HILIC columns with respect to peak efficiency and selectivity have been documented under these different mobile phase conditions, and the results compared with the performance of a conventional capillary reversed-phase C18 column of similar dimensions. It was found that very good separation of the peptide set could be achieved by using the amide-modified silica column over a broad pH range. Moreover, with the protein digest samples, excellent separation of the tryptic digests was obtained with the amide-modified HILIC column under neutral pH conditions. Compared to the conventional reversed-phase C18 separations, the use of these HILIC columns not only provided complementary separation selectivity, but also offered the capability to identify unique peptides using tandem HILIC–mass spectrometric techniques. These studies therefore highlight the potential of HILIC procedures for future proteomic applications.  相似文献   

9.
Hydrophilic interaction chromatography (HILIC) is an increasingly popular alternative to conventional HPLC for drug analysis. It offers increased selectivity and sensitivity, and improved efficiency when quantifying drugs and related compounds in complex matrices such as biological and environmental samples, pharmaceutical formulations, food, and animal feed. In this review we summarize HILIC methods recently developed for drug analysis (2006–2011). In addition, a list of important applications is provided, including experimental conditions and a brief summary of results. The references provide a comprehensive overview of current HILIC applications in drug analysis.   相似文献   

10.
An ion-pair liquid chromatography-electrospray mass spectrometry (LC-ESI-MS) method with in vivo microdialysis for the determination of free-form amphetamine in rat brain has been developed. A microdialysis probe was surgically implanted into the striatum of the rat and artificial cerebrospinal fluid (aCSF) was used as the perfusion medium. Samples were collected and then analyzed off-line by LC-ESI-MS. A reversed phase C18 column was employed for LC separation. Trifluoroacetic acid (TFA) was added in the mobile phase (acetonitrile-water, 10:90, v/v) as an ion-pair reagent. The ion-pair process disguises the protonated amphetamine cations from the ESI-MS electric field as neutral molecules. Post-column addition of volatile organic acid was utilized to minimize TFA signal suppression effect on ESI-MS detection. More than six-fold enhancement of ESI-MS response was achieved by the post-column addition of propionic acid. Good linearity (0.01-1.00 microg/ml, r2 = 0.99) and detection limit (0.002 microg/ml) were determined. Good precision and accuracy were obtained. The applicability of this newly developed method was demonstrated by continuous monitoring of amphetamine concentrations in rat brain after a single 3.0 mg/kg i.p. administration.  相似文献   

11.
Hydrophilic interaction liquid chromatography (HILIC) was examined for the separation of paralytic shellfish poisoning (PSP) toxins using the stationary phase TSK-gel Amide-80. The parameters tested included type of organic modifier and percentage in the mobile phase, buffer concentration, pH, flow rate and column temperature. Using mass spectrometric (MS) detection, the HILIC column allowed the determination of all the major PSP toxins in one 30 min analysis with a high degree of selectivity and sensitivity. The high percentage of organic modifier in the mobile phase and the omission of ion pairing reagents, both favored in HILIC, provided limits of detection (LOD) in the range 50-100 nM in selected ion monitoring (SIM) mode on a single quadrupole LC-MS system. LOD in selected reaction monitoring (SRM) mode on a sensitive triple quadrupole system were as low as 5-30 nM. Excellent linearity of response was observed.  相似文献   

12.
Jia S  Park JH  Lee J  Kwon SW 《Talanta》2011,85(5):2301-2306
Comparison of hydrophilic interaction chromatography (HILIC) columns coupled with an evaporative light scattering detector (ELSD) or charged aerosol detector (CAD) was done for the detection of gabapentin in pharmaceutical formulations. The chromatographic separations were achieved on four HILIC columns: ZIC HILIC, ZIC pHILIC, Luna HILIC, and Atlantis HILIC. Experimental factors such as mobile phase composition, acetonitrile content, and mobile phase pH were evaluated. Validation of method was done in terms of linearity, sensitivity, accuracy, and precision. The performance of ELSD detection method is comparable to that of CAD. The intra-day and inter-day variations were below 1.7% and 3.2% for CAD and 2.8%, and 3.4% for ELSD, respectively. In addition, detection sensitivities of ELSD, CAD, and UV detectors were also compared for HILIC and reversed phase (RP) modes and the highest sensitivities were obtained in the HILIC mode when connected with CAD and ELSD. The developed HILIC aerosol based detection methods were successfully applied to the analysis of gabapentin in commercial tablets and capsules.  相似文献   

13.
14.
Li Y  Feng Y  Chen T  Zhang H 《Journal of chromatography. A》2011,1218(35):5987-5994
An imidazoline was prepared by solvent-free microwave-assisted organic synthesis and immobilized on porous silica particles by polymerization. The resulting material was composed of both hydrophobic alkyl ester chains and hydrophilic imidazoline rings, which gave it both hydrophilic interaction and reversed-phase characteristics. The titration curve suggests that the new material has buffering capacity and acquires increasing positive charge over the pH range 9-4, and is "zwitterionic" in the upper part of this pH range. Through investigating the effect of column temperature, the water content, pH and ion strength of mobile phase on the retention time of polar compounds in highly organic eluents, it was found that the new material could be used as a hydrophilic interaction liquid chromatography (HILIC) stationary phase which involved a complex retention process consisting of partitioning, surface adsorption and electrostatic interactions. In addition, the retention behavior of aromatic compounds in different mobile phase conditions was also studied, which showed the new material mainly exhibited a partitioning mechanism in the reversed-phase liquid chromatography (RPLC) mode. The separation of six water-soluble vitamins and five aromatic compounds were achieved by using the new material in the HILIC and RPLC modes, respectively.  相似文献   

15.
A hydrophilic interaction chromatography-electrospray ionization tandem mass spectrometric method was developed for determination of anastrozole in human plasma. Anastrozole and irbesartan (internal standard) were extracted from human plasma with a mixture of dichloromethane and methyl tert-butyl ether (30:70, v/v). Analysis of the analytes was performed on a Luna HILIC column with the mobile phase of acetonitrile-10 m m ammonium formate (95:5, v/v) and detected by electrospray ionization tandem mass spectrometry in the selected reaction monitoring mode. The standard curve was linear (r(2) = 0.9992) over the concentration range of 0.10-50.0 ng/mL using 200 μL of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.2-10.0% and -7.2-3.2%, respectively. The present method was applied successfully to the pharmacokinetic study of anastrozole after oral administration of 1 mg anastrozole tablet to healthy male volunteers.  相似文献   

16.
Li Y  Li J  Chen T  Liu X  Zhang H 《Journal of chromatography. A》2011,1218(11):1503-1508
The mixed sulfated/methacryloyl polysaccharide derivative was prepared and successfully immobilized onto the surface of porous silica particles by polymerization. Polysaccharide derivative was calculated as 10.33% in the stationary phase prepared. The new stationary phase (PMSP) showed both hydrophilic interaction (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The effects of column temperature, the water content, pH and ion strength of mobile phase on the retention time of test compounds in highly aqueous eluents were investigated to evaluate the PALC features of PMSP. The column efficiency is about 31,000 plates/m for benzoic acid in water/ACN (97/3, v/v) mobile phase at a flow rate of 1.0 mL/min. Compared with C18 column, the PMSP had shorter retention time for weak polar and non-polar compounds, but also showed stronger retention for strong polar compounds. It indicated that PALC was a suitable mode of chromatography as replacement of HILIC and complementarity of reversed-phase liquid chromatography (RPLC).  相似文献   

17.
A hydrophilic interaction chromatography‐tandem mass spectrometric method (HILIC/MS/MS) for the determination of irbesartan in human plasma was developed. Irbesartan and losartan (internal standard) were extracted from human plasma with ethyl acetate at acidic pH. The analytes were analyzed on a Luna HILIC column with the mobile phase of ACN–ammonium formate (50 mM, pH 6.5) (96:4, v/v) and detected by ESI MS/MS in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.9981) over the concentration range of 10–2500 ng/mL and the lower LOQ was 10 ng/mL using 100 μL of plasma sample. The CV and relative error for intra‐ and interassay at four QC levels were 2.9 to 8.1% and –2.7 to 2.3%, respectively. There were less absolute and relative matrix effects for irbesartan and losartan. The present method was successfully applied to the pharmacokinetic study of irbesartan after oral dose of irbesartan (150 mg tablet) to male healthy volunteers.  相似文献   

18.
Streptomycin (STR) and dihydrostreptomycin (DHSTR) are two of the most common aminoglycoside antibiotics used in veterinary medicine. The physicochemical properties of both substances, make their determination challenging. In the present study the development of methods based on ion-pair chromatography (IPC) and on hydrophilic interaction chromatography (HILIC), for the determination of the above mentioned aminoglycosides in the range of 100–1000 μg L−1 is described. The two methods were validated according to EU requirements for residues in food. The recoveries for the IPC method were 69.3% and 56.5% of STR and DHSTR, respectively, and for HILIC method 85.5% and 72.3%, respectively. The intra- and inter-day precision, studied at 100, 200 and 300 μg kg−1 levels in milk samples, gave %RSD ≤ 13 for both methods. LOQs for the HILIC method were 14 μg kg−1 for both analytes and for the IPC method were 109 and 31 μg kg−1, for STR and DHSTR, respectively. The sensitivity of the HILIC method is 80 and 210 times greater than that of the ICP method, for STR and DHSTR, respectively.  相似文献   

19.
Organic acids with very low pKa require extremely low pH conditions to achieve adequate retention in reversed‐phase liquid chromatography, but an extremely low pH mobile phase can cause instrument reliability problems and limit the choice of columns. Hydrophilic interaction chromatography is a potential alternative to reversed‐phase liquid chromatography for the separation of organic acids using more moderate conditions. However, the hydrophilic interaction chromatography separation mechanism is known to be very complex and involves multiple competing mechanisms. In the present study, a hydrophilic interaction chromatography column packed with bare silica core–shell particles was used as the separation column and six agricultural organic acids were used as model analytes to evaluate the effects of buffer concentration, buffer pH, and temperature on sample loading capacity, selectivity, retention, and repeatability. It was found that using a higher concentration of buffer can lead to a significant improvement in the overall performance and reproducibility of the separation. Investigation of column equilibration time revealed that a very long equilibration time is needed when changing mobile phase conditions in between runs. This limitation needs to be acknowledged in hydrophilic interaction chromatography method development and sufficient equilibration time needs to be allowed in method scouting.  相似文献   

20.
The adsorption behavior of proline under hydrophilic interaction chromatography conditions was investigated from six aqueous solutions of acetonitrile. Proline adsorption isotherms were recorded at each mobile phase composition by frontal analysis and inverse method. The BET model was found to be the best choice to describe the nonlinear behavior of proline adsorption under hydrophilic interaction chromatography conditions. The adsorption isotherm parameters were derived from two independent parameter estimation methods. The parameters derived from regression analysis of the frontal analysis data and from overloaded elution bands were found to be in good agreement with the excess isotherm of water. The mobile phase composition at which the maximum excess adsorption of water was observed corresponded to the maximum saturation capacity measured for proline.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号