首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
This study presents the dielectrophoretic (DEP) assembly of multi‐walled carbon nanotubes (MWCNTs) between curved microelectrodes for the purpose of trapping polystyrene microparticles within a microfluidic system. Under normal conditions, polystyrene particles exhibit negative DEP behaviour and are repelled from microelectrodes. Interestingly, the addition of MWCNTs to the system alters this situation in two ways: first, they coat the surface of particles and change their dielectric properties to exhibit positive DEP behaviour; second, the assembled MWCNTs are highly conductive and after the deposition serve as extensions to the microelectrodes. They establish an array of nanoelectrodes that initiates from the edge of microelectrodes and grow along the electric field lines. These nanoelectrodes can effectively trap the MWCNT‐coated particles, since they cover a large portion of the microchannel bottom surface and also create a much stronger electric field than the primary microelectrodes as confirmed by our numerical simulations. We will show that the presence of MWCNT significantly changes performance of the system, which is investigated by trapping sample polystyrene particles with plain, COOH and goat anti‐mouse IgG surfaces.  相似文献   

2.
Particle separation is a fundamental operation in the areas of biology and physical chemistry. A variety of force fields have been used to separate particles in microfluidic devices, among which electric field may be the most popular one due to its general applicability and adaptability. So far, however, electrophoresis‐based separations have been limited primarily to batchwise processes. Dielectrophoresis (DEP)‐based separations require in‐channel micro‐electrodes or micro‐insulators to produce electric field gradients. This article introduces a novel particle separation technique in DC electrokinetic flow through a planar double‐spiral microchannel. The continuous separation arises from the cross‐stream dielectrophoretic motion of particles induced by the non‐uniform electric field inherent to curved channels. Specifically, particles are focused by DEP to one sidewall of the first spiral, and then dielectrophoretically deflected toward the other sidewall of the second spiral at a particle‐dependent rate, leading to focused particle streams along different flow paths. This DEP‐based particle separation technique is demonstrated in an asymmetric double‐spiral microchannel by continuously separating a mixture of 5/10 μm particles and 3/5 μm particles.  相似文献   

3.
Jen CP  Weng CH  Huang CT 《Electrophoresis》2011,32(18):2428-2435
The focusing of biological and synthetic particles in microfluidic devices is a prerequisite for the construction of microstructured materials, as well as for medical applications. In the present study, a microdevice that can effectively focus particles in three dimensions using a combination of insulator-based and metal-electrode dielectrophoresis (DEP) has been designed and fabricated. The DEP force is employed to confine the particles using a negative DEP response. Four insulating microstructures, which form an X-pattern in the microchannel, were employed to distort the electric field between the insulators in a conducting solution, thereby generating regions with a high electric-field gradient. Two strips of microelectrodes on the top and bottom surfaces were placed in the middle of the microchannel and connected to an electric pole. Two sets of dual-planar electrodes connected to the opposite pole were placed at the sides of the microchannel at the top and bottom surfaces. The results of a transient simulation of tracks of polystyrene particles, which was performed using the commercial software package CFD-ACE? (ESI Group, France), demonstrate that the three-dimensional focusing of particles was achieved when the applied voltage was larger than 35?V at a frequency of 1 MHz. Furthermore, the focusing performance increased with the increased strength of the applied electric field and decreased inlet flow rate. Experiments on particle focusing, employing polystyrene particles 10 μm in diameter, were conducted to demonstrate the feasibility of the proposed design; the results agree with the trend predicted by numerical simulations.  相似文献   

4.
This paper reports an impedance‐based system for the quantitative assessment of dielectrophoretic (DEP) focusing of single particles flowing in a microchannel. Particle lateral positions are detected in two electrical sensing zones placed before and after a DEP‐focusing region, respectively. In each sensing zone, particle lateral positions are estimated using the unbalance between the opposite pulses of a differential current signal obtained with a straightforward coplanar electrode configuration. The system is used to monitor the focusing of polystyrene beads of 7 or 10 μm diameter, under various conditions of DEP field intensities and flow rates that produce different degrees of focusing. This electrical approach represents a simple and valuable alternative to optical methods for monitoring of particle focusing systems.  相似文献   

5.
This article compares the operation of a dielectrophoretic (DEP) platform before and after pattering carbon nanotubes (CNTs) between its microelectrodes. The diverse performance of the DEP system is assessed by separating 1 and 5 μm polystyrene particles. In the absence of CNTs, both particles can only be trapped by operating the system at low medium conductivities, (<10−3 S/m) and frequencies (<75 kHz). Alternatively, applying CNTs to the system, some CNTs coat the surface of particles and increase their overall conductivity and permittivity, whereas the rest of them are patterned between the microelectrodes and induce strong DEP forces at their free ends, which can effectively trap the coated particles. The first development extends the range of medium conductivities and frequencies at which the trapping of both particles is achievable, whereas the second development facilitates the selective deposition of particles along the surface of curved microelectrodes. Setting the medium conductivity to 2×10−3 S/m and the frequency to 20 MHz, most of 5 μm particles are trapped at the entry region of the first microelectrode pair, whereas most of 1 μm particles are trapped at the tips, and this distinction facilitates their separation. The trapping of 1 μm particles can be improved by decreasing the frequency to 1.5 MHz. This study demonstrates how the integration of CNTs into microfluidic systems enables them to operate beyond their capabilities.  相似文献   

6.
The dielectrophoretic (DEP) choking phenomenon is revisited for Janus particles that are transported electrokinetically through a microchannel constriction by a direct‐current (DC) electric field. The negative DEP force that would block a particle with a diameter significantly smaller than that of the constriction at its inlet is seen to be relaxed by the rotation of the Janus particle in a direction that minimizes the magnitude of the DEP force. This allows the particle to pass through the constriction completely. An arbitrary Lagrangian‐Eulerian (ALE) numerical method is used to solve the nonlinearly coupled electric field, flow field, and moving particle, and the DEP force is calculated by the Maxwell stress tensor (MST) method. The results show how Janus particles with non‐uniform surface potentials overcome the DEP force and present new conditions for the DEP choking by a parametric study. Particle transportation through microchannel constrictions is ubiquitous, and particle surface properties are more likely to be non‐uniform than not in practical applications. This study provides new insights of importance for non‐uniform particles transported electrokinetically in a microdevice.  相似文献   

7.
This work demonstrates the application of dielectrophoretic (DEP) control of silica nanoparticles to form tuneable optical elements within a microfluidic system. The implementation consisted of a microfluidic channel with an array of curved microelectrodes along its base. Various DEP conditions were investigated at alternating current voltage amplitudes, flow rates and frequencies from 5 to 15 V, 2 to 10 μL/min and 0 to 20 MHz, respectively. The fluid channel was filled with deionized water suspending silica particles with diameters of 230 and 450 nm. Experiments were conducted to demonstrate DEP concentration and deflection of the particles and the impact of these particles distributions on the optical transmission through the fluid channel. Both confinement and scattering of the light were observed depending on the particle dimensions and the parameters of the DEP excitation. The results of this investigation illustrate the feasibility of DEP control in an optofluidic system and represent a significant step toward the dynamic formation of electrically controlled liquid optical waveguides.  相似文献   

8.
Cheng W  Li SZ  Zeng Q  Yu XL  Wang Y  Chan HL  Liu W  Guo SS  Zhao XZ 《Electrophoresis》2011,32(23):3371-3377
We present a feasible dielectrophoresis (DEP) approach for rapid patterning of microparticles on a reusable double-layer electrode substrate in microfluidics. Simulation analysis demonstrated that the DEP force was dramatically enhanced by the induced electric field on top interdigitated electrodes. By adjusting electric field intensity through the bottom electrodes on thin glass substrate (100 μm), polystyrene particles (10 μm) were effectively patterned by top electrodes within several seconds (<5 s). The particle average velocity can reach a maximum value of about 20.0±3.0 μm/s at 1 MHz with the strongest DEP force of 1.68 pN. This approach implements integration of functional electrodes into one substrate and avoids direct electrical connection to biological objects, providing a potential lab-on-chip system for biological applications.  相似文献   

9.
A lab-on-a-chip device is described for continuous sorting of fluorescent polystyrene microparticles utilizing direct current insulating dielectrophoresis (DC-iDEP) at lower voltages than previously reported. Particles were sorted by combining electrokinetics and dielectrophoresis in a 250 μm wide PDMS microchannel containing a rectangular insulating obstacle and four outlet channels. The DC-iDEP particle flow behaviors were investigated with 3.18, 6.20 and 10 μm fluorescent polystyrene particles which experience negative DEP forces depending on particle size, DC electric field magnitude and medium conductivity. Due to negative DEP effects, particles are deflected into different outlet streams as they pass the region of high electric field density around the obstacle. Particles suspended in dextrose added phosphate buffer saline (PBS) at conductivities ranging from 0.50 to 8.50 mS/cm at pH 7.0 were compared at 6.85 and 17.1 V/cm. Simulations of electrokinetic and dielectrophoretic forces were conducted with COMSOL Multiphysics® to predict particle pathlines. Experimental and simulation results show the effect of medium and voltage operating conditions on particle sorting. Further, smaller particles experience smaller iDEP forces and are more susceptible to competing nonlinear electrostatic effects, whereas larger particles experience greater iDEP forces and prefer channels 1 and 2. This work demonstrates that 6.20 and 10 μm particles can be independently sorted into specific outlet streams by tuning medium conductivity even at low operating voltages. This work is an essential step forward in employing DC-iDEP for multiparticle sorting in a continuous flow, multiple outlet lab-on-a-chip device.  相似文献   

10.
利用微通道法乳化技术原理,研制了一个可拆卸T型玻璃微通道装置,以聚乙烯醇水溶液为连续相,聚(乳酸-co-羟基乙酸)(PLGA)的二氯甲烷溶液为分散相,制备了单分散的PLGA微球.考察了乳化剂用量、连续相和分散相流速以及PLGA浓度对形成的液滴平均粒径和变异系数(CV值)的影响.结果表明,增大乳化剂用量,提高连续相流速或降低分散相流速,制备得到的PLGA微球直径减小;分散相浓度在5~20 g/L之间变化时,其对微球直径的影响有限.PLGA微球表面光滑无孔,且内部是实心的.用本装置制备得到的PLGA微球,其粒径范围在30~200μm之间,CV值在15%以下,最低可至3%.该方法可使用挥发性有机溶剂作为分散相而且能避免微球制备时易堵塞等问题,可应用于药物缓控释领域中微米级单分散微球的制备.  相似文献   

11.
Kang KH  Kang Y  Xuan X  Li D 《Electrophoresis》2006,27(3):694-702
Direct current-dielectrophoresis (DC-DEP), the induced motion of the dielectric particles in a spatially nonuniform DC electric field, is demonstrated to be a highly efficient method to separate the microparticles by size. The locally nonuniform electric field is generated by an insulating block fabricated inside a polydimethylsiloxane microchannel. The particle experiences a negative DEP (accordingly a repulsive force) at the corners of the block, where the local electric-field strength is the strongest. Thus, the particle deviates from the streamline and the degree of deviation is dependent on the DEP force (i.e., the particle size). Combined with the electrokinetic flow, mixed polystyrene particles of a few micrometers difference in diameter can be continuously separated into distinct reservoirs. For separating target particles of a specific size, it is required to simply adjust the voltage outputs of the electrodes. A numerical model based on the Lagrangian tracking method is developed to simulate the particle motion and the results showed a reasonable agreement with the experimental data.  相似文献   

12.
Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.  相似文献   

13.
Nam J  Lim H  Kim D  Jung H  Shin S 《Lab on a chip》2012,12(7):1347-1354
Pure separation and sorting of microparticles from complex fluids are essential for biochemical analyses and clinical diagnostics. However, conventional techniques require highly complex and expensive labeling processes for high purity separation. In this study, we present a simple and label-free method for separating microparticles with high purity using the elasto-inertial characteristic of a non-Newtonian fluid in microchannel flow. At the inlet, particle-containing sample flow was pushed toward the side walls by introducing sheath fluid from the center inlet. Particles of 1 μm and 5 μm in diameter, which were suspended in viscoelastic fluid, were successfully separated in the outlet channels: larger particles were notably focused on the centerline of the channel at the outlet, while smaller particles continued flowing along the side walls with minimal lateral migration towards the centerline. The same technique was further applied to separate platelets from diluted whole blood. Through cytometric analysis, we obtained a purity of collected platelets of close to 99.9%. Conclusively, our microparticle separation technique using elasto-inertial forces in non-Newtonian fluid is an effective method for separating and collecting microparticles on the basis of size differences with high purity.  相似文献   

14.
AC electroosmotic (ACEO) flow above the gap between coplanar electrodes is mapped by the measurement of Stokes forces on an optically trapped polystyrene colloidal particle. E2‐dependent forces on the probe particle are selected by amplitude modulation (AM) of the ACEO electric field (E) and lock‐in detection at twice the AM frequency. E2‐dependent DEP of the probe is eliminated by driving the ACEO at the probe's DEP crossover frequency. The location‐independent DEP crossover frequency is determined, in a separate experiment, as the limiting frequency of zero horizontal force as the probe is moved toward the midpoint between the electrodes. The ACEO velocity field, uncoupled from probe DEP effects, was mapped in the region 1–9 μm above a 28 μm gap between the electrodes. By use of variously sized probes, each at its DEP crossover frequency, the frequency dependence of the ACEO flow was determined at a point 3 μm above the electrode gap and 4 μm from an electrode tip. At this location the ACEO flow was maximal at ~117 kHz for a low salt solution. This optical trapping method, by eliminating DEP forces on the probe, provides unambiguous mapping of the ACEO velocity field.  相似文献   

15.
This paper reports a microfluidic method of continuous separation of marine algae and particles by DC dielectrophoresis. The locally non-uniform electric field is generated by an insulating PDMS triangle hurdle fabricated within a PDMS microchannel. Both the particles and algae are subject to negative DEP forces at the hurdle where the gradient of local electric-field strength is the strongest. The DEP force acting on the particle or the algae depends on particles’ or algae’s volume, shape and dielectric properties. Thus the moving particles and algae will be repelled to different streamlines when passing the hurdle. In this way, combined with the electroosmotic flow, continuous separation of algae of two different sizes, and continuous separation of polystyrene particles and algae with similar volume but different shape were achieved. This first demonstration of DC DEP separation of polystyrene particles and algae with similar sizes illustrates the great influence of dielectric properties on particle separation and potentials for sample pretreatment.  相似文献   

16.
We report a contraction-expansion array (CEA) microchannel that allows inertial size separation by a force balance between inertial lift and Dean drag forces in fluid regimes in which inertial fluid effects become significant. An abrupt change of the cross-sectional area of the channel curves fluid streams and produces a similar effect compared to Dean flows in a curved microchannel of constant cross-section, thereby inducing Dean drag forces acting on particles. In addition, the particles are influenced by inertial lift forces throughout the contraction regions. These two forces act in opposite directions each other throughout the CEA microchannel, and their force balancing determines whether the particles cross the channel, following Dean flows. Here we describe the physics and design of the CEA microfluidic device, and demonstrate complete separation of microparticles (polystyrene beads of 4 and 10 μm in diameter) and efficient exchange of the carrier medium while retaining 10 μm beads.  相似文献   

17.
Fluoride deposition into the pores of enamel is necessary at high concentrations to reduce enamel demineralization and with a high degree of penetration to account for loss by ingestion. Current diffusion and electrochemical methods are inadequate for effectively transporting fluoride greater than 20 μm into enamel. The study explores the coupling of dielectrophoresis (DEP) and AC electroosmosis (ACEO) to selectively concentrate fluoride particles from fluoride gel excipients and enhance their penetration into enamel. By measuring the frequency response of approximately 10‐μm‐sized sodium fluoride particles in an aqueous gel media, appropriate frequencies for positive DEP, negative DEP, and ACEO are identified. An assembly composed of two cross‐planar interdigitated electrode (IDE) arrays with open slots is driven successively by fields at appropriate frequencies to drive fluoride particles through the slots of the IDE and into the enamel pores using a combination of DEP and ACEO methods. Fluoride uptake and penetration of 1.23% acidulated phosphate fluoride gel into bovine tooth enamel at various depths is measured using wavelength dispersive spectrometry to compare deposition by diffusion, DEP, and DEP plus ACEO. Fluoride levels in all DEP groups were significantly higher than diffusion groups at depths 10 and 20 μm. The highest fluoride concentrations at 10, 20, 50, and 100 μm depths occur under deposition conditions combining DEP with ACEO. Fluoride levels at 50 μm were equivalent to long‐term prophylactic exposure. These methods may potentially benefit populations at high risk for development of caries and periodontal disease, including underserved children and disparate groups.  相似文献   

18.
This study presents a new DEP manipulation technique using a movable liquid electrode, which allows manipulation of particles by actively controlling the locations of electrodes and applying on–off electric input signals. This DEP system consists of mercury as a movable liquid electrode, indium tin oxide (ITO)‐coated glass, SU‐8‐based microchannels for electrode passages, and a PDMS medium chamber. A simple squeezing method was introduced to build a thin PDMS layer at the bottom of the medium chamber to create a contactless DEP system. To determine the operating conditions, the DEP force and the friction force were analytically compared for a single cell. In addition, an appropriate frequency range for effective DEP manipulation was chosen based on an estimation of the Clausius–Mossotti factor and the effective complex permittivity of the yeast cell using the concentric shell model. With this system, we demonstrated the active manipulation of yeast cells, and measured the collection efficiency and the dielectrophoretic velocity of cells for different AC electric field strengths and applied frequencies. The experimental results showed that the maximum collection efficiency reached was approximately 90%, and the dielectrophoretic velocity increased with increasing frequency and attained the maximum value of 10.85 ± 0.95 μm/s at 100 kHz, above which it decreased.  相似文献   

19.
Tsai SL  Hong JL  Chen MK  Jang LS 《Electrophoresis》2011,32(11):1337-1347
This work presents a microfluidic system that can transport, concentrate, and capture particles in a controllable droplet. Dielectrophoresis (DEP), a phenomenon in which a force is exerted on a dielectric particle when it is subjected to a non-uniform electric field, is used to manipulate particles. Liquid dielectrophoresis (LDEP), a phenomenon in which a liquid moves toward regions of high electric field strength under a non-uniform electric field, is used to manipulate the fluid. In this study, a mechanism of droplet creation presented in a previous work that uses DEP and LDEP is improved. A driving electrode with a DEP gap is used to prevent beads from getting stuck at the interface between air and liquid, which is actuated with an AC signal of 200 V(pp) at a frequency of 100 kHz. DEP theory is used to calculate the DEP force in the liquid, and LDEP theory is used to analyze the influence of the DEP gap. The increment of the actuation voltage due to the electrode with a DEP gap is calculated. A set of microwell electrodes is used to capture a bead using DEP force, which is actuated with an AC signal of 20 V(pp) at a frequency of 5 MHz. A simulation is carried out to investigate the dimensions of the DEP gap and microwell electrodes. Experiments are performed to demonstrate the creation of a 100-nL droplet and the capture of individual 10-μm polystyrene latex beads in the droplet.  相似文献   

20.
When aqueous suspensions of 1 μm, negatively charged polystyrene particles are subject to a 1 kHz alternating electric field of strength greater than 7 kV(rms) m(-1), dynamic elliptical clusters of particles spontaneously form. With potential applications in microchannel fluidics in mind, we characterize how cluster formation and particle circulation, driven by induced dipole-dipole interactions, is critically dependent on time, field strength, electrolyte concentration, and cell thickness. Logarithmic growth of cluster size is observed, and particle velocity within the clusters is found to be proportional to cluster length. Increasing cell thickness from 10 to 60 μm increases the projected cluster area but decreases cluster aspect ratio as the result of changing particle dispersal rates. Clusters are shown to generate significant fluid shear suitable for microchannel mixing applications. These clusters are observed to distort under transverse fluid flow and, above a critical flow rate, to undergo a transition to form regularly spaced particle streams, which may be suitable for two-dimensional visualization of fluid flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号