首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A potentiometric and/or visual method for the determination of sulphamethoxazole (SULF) in pure form in the range of 5.3 × 10–5 to 5.0 × 10–4 mol/L is proposed. To enhance the solubility, the determination has been carried out in a micellar medium formed by an aqueous 5.0 × 10–2 mol/L N-hexadecyl-N,N,N-trimethyl ammonium bromide (CTAB) solution which increases the dissociation constant K of SULF about tenfold. The titration is performed with NaOH (2.5 × 10–3 or 5.0 × 10–2 mol/L) and the end-point is determined by the second derivative graph. The results agree with those obtained by the official method of the USP XXIII. The method is simple, accurate, economical and can successfully replace the more complicated, more expensive and time-consuming existent procedures which are carried out in a non-aqueous medium.  相似文献   

2.
郑妍鹏  莫金垣  谢天尧 《色谱》2002,20(2):159-162
 采用柠檬酸 柠檬酸钠作为缓冲体系 ,使用负高压 ,对Cl-,NO3 -,HCO3 -和H2 PO4 -等 4种常见阴离子进行了分离检测 ,研究了缓冲剂的种类、浓度、pH值及操作电压对分离的影响。在选定的条件下 ,4种离子的定量线性范围 :Cl-5 0× 10 -5mol/L~ 2 5× 10 -3 mol/L ,NO3 -6 0× 10 -5mol/L~ 2 0× 10 -3 mol/L ,HCO3 -5 0× 10 -6mol/L~ 2 0× 10 -4 mol/L ,H2 PO4 -6 0× 10 -5mol/L~ 1 0× 10 -3 mol/L ;检出限 :Cl-1 5× 10 -5mol/L ,NO3 -3 0×10 -5mol/L ,HCO3 -1 0× 10 -6mol/L ,H2 PO4 -2 0× 10 -5mol/L ;峰面积的RSD (n =6 ) :Cl-3 1% ,  相似文献   

3.
A rapid, selective, and sensitive kinetic flow-injection method for iodide content determination with amperometric detection on a platinum electrode was developed. The method is based on the catalytic effect of iodide on the Mn3+ reaction with As3+ in the presence of sulfuric acid. The calibration curve was linear in the concentration range from 5.0 x 10(-7) to 1.0 x 10(-4) mol/L iodide. The limit of detection (LOD) was found to be 5.0 x 10(-9) mol/L iodide. The relative standard deviations (RSD) were 1.68% and 3.03% for 1.0 x 10(-3) mol/L standard and 1.0 x 10(-6) mol/L iodide solution (n = 6), respectively. The method has been successfully applied for determination of iodide in waters, table salts, fodder, organic substances and human blood sera. The results were compared with those obtained by a standard AOAC (Association of Official Analytical Chemists) method, as well as with those obtained by a kinetic spectrophotometric procedure for determination of iodide.  相似文献   

4.
A column chromatographic method has been developed for the separation and determination of cerium(Ⅲ) using poly[dibenzo-18-crown-6]. The separation was carried out in L-valine medium. The adsorption of cerium(Ⅲ) was quantitative from 1×10-1 to 1×10-4 mol/L L-valine. Amongst the various eluents, 1.0-8.0 mol/L hydrochloric acid, 1.0-8.0 mol/L hydrobromic acid, 1.0-8.0 mol/L perchloric acid, 1.0-2.0 mol/L sulfuric acid and 4.0-5.0 mol/L acetic acid, were found to be the efficient eluents for cerium(Ⅲ). The capacity of poly[dibenzo-18-crown-6] for cerium(Ⅲ) was (0.428±0.01) mmol/g. The method was applied to the separation of cerium(Ⅲ) from associated elements link uranium(Ⅵ) and thorium(Ⅳ). It was also applied for the determination of cerium(Ⅲ) in geological samples. The method is simple, rapid and selective with good reproducibility (approximately±2% ).  相似文献   

5.
 A column chromatographic method has been developed for the separation and determination of cerium(Ⅲ) using poly[dibenzo-18-crown-6]. The separation was carried out in L-valine medium. The adsorption of cerium(Ⅲ) was quantitative from 1×10-1 to 1×10-4 mol/L L-valine. Amongst the various eluents, 1.0-8.0 mol/L hydrochloric acid, 1.0-8.0 mol/L hydrobromic acid, 1.0-8.0 mol/L perchloric acid, 1.0-2.0 mol/L sulfuric acid and 4.0-5.0 mol/L acetic acid, were found to be the efficient eluents for cerium(Ⅲ). The capacity of poly[dibenzo-18-crown-6] for cerium(Ⅲ) was (0.428±0.01) mmol/g. The method was applied to the separation of cerium(Ⅲ) from associated elements link uranium(Ⅵ) and thorium(Ⅳ). It was also applied for the determination of cerium(Ⅲ) in geological samples. The method is simple, rapid and selective with good reproducibility (approximately±2%).  相似文献   

6.
A novel method for determination of trace amounts of tosufloxacin (TFLX) based on electrochemiluminescence (ECL) has been developed. The calibration graphs for TFLX were linear in the range of 5.0 x 10(-11)-3.5 x 10(-7) mol/L, with the detection limit of 1.3 x 10(-11) mol/L. Key factors affecting the determination of TFLX were investigated. TFLX amounts in capsule and serum samples were successfully detected by this method. A possible mechanism of energy transfer, and thus the explanation of ECL in the Tb3+-TFLX-Na2S2O4 system are discussed.  相似文献   

7.
This paper describes an environmentally friendly method for quantitative determination of ranitidine using diffuse reflectance spectroscopy. This method is based on the reflectance measurements of the colored product produced from the spot test reaction between ranitidine and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using filter paper as solid support. Experimental design methodologies were used to optimize the optimal conditions. All reflectance measurements were carried out at 590 nm and the linear range was from 1.42x10(-3) to 3.42x10(-2) mol L(-1), with a correlation coefficient of 0.997. The limit of detection was estimated to be 1.09x10(-3) mol L(-1) (R.S.D.=1.9%). The proposed method was successfully applied to the determination of ranitidine in commercial brands of pharmaceuticals and no interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those obtained by an official procedure at 95% confidence level. Additionally, the method was also applied to the determination of ranitidine in human urine showing excellent recoveries (99.6-100.3%).  相似文献   

8.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

9.
A flow-injection analysis (FIA) with a chemiluminescence detection method was developed for the determination of ornidazole based on the inhibition intensity of chemiluminescence from the luminol-ferricyanide system. Under the condition of 1.0 x 10(-3) mol/L luminol and 5.0 x 10(-6) mol/L potassium ferricyanide, the response to the concentration of omidazole is linear from 0.2 microg ml(-1) to 10 microg ml(-1), and a detection limit of 0.05 microg ml(-1) can be obtained. This method has been successfully applied to the determination of omidazole in pharmaceutical preparations.  相似文献   

10.
A simple, accurate and sensitive method for the microdetermination of benzocaine, lignocaine and procaine hydrochlorides in pure forms and in pharmaceutical formulations is described. The procedure is based on the reaction of those drugs in an aqueous acidic medium with p-benzoquinone to form charge-transfer complexes. The method has been used for the determination of 5.0-70, 5.0-60 and 5.0-90 microg ml(-1) of benzocaine, lignocaine HCl and procaine HCl, respectively. The complexes have apparent molar absorptivities of 1.70 x 10(3), 2.79 x 10(3) and 2.42 x 10(3) L mol(-1) cm(-1) and Sandell sensitivities of 9.72, 10.34 and 11.25 ng cm(-2), respectively. The proposed procedure of analysis is as accurate as the British Pharmacopoeial method (2003). The method was successfully used for the determination of those drugs in the presence of their degradation products, additives and excipients, which were normally encountered in pharmaceutical formulations.  相似文献   

11.
Guan Y  Chu Q  Fu L  Ye J 《Journal of chromatography. A》2005,1074(1-2):201-204
A new and efficient method for the determination of antioxidants [Propyl gallate (PG), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT)] in cosmetics has been established by using micellar electrokinetic capillary chromatography with electrochemical detection (MECC-ED). Under the optimum conditions of the method, all analytes were successfully separated within 13 min at the separation voltage of 18 kV in a 20 mmol/L borate running buffer (pH 7.4) containing 25 mmol/L sodium dodecyl sulfate. The excellent linearity was obtained in the concentration range from 5.0 x 10(-4) to 2.0 x 10(-6) mol/L and the detection limits (S/N = 3) of PG, TBHQ, BHA, and BHT range from 3 x 10(-7) to 3 x 10(-6) mol/L.  相似文献   

12.
Based on the adsorption of Fe(EDTA)- on a chitosan-coated glassy carbon electrode, a second-derivative square-wave voltammetry for the determination of the EDTA species in water samples was investigated. The measuring range of EDTA was from 6.0 x 10(-7) to 5.0 x 10(-5) mol/L with a correlation coefficient of 0.998 and a detection limit of 2.8 x 10(-7) mol/L. The relative standard deviation was less than 6.2% (n = 5) and the recovery was in the range of 98-105% for the determination of practical samples. The result was consistent with that from the HPLC method.  相似文献   

13.
A new chemiluminescence method for the determination of carbamazepine (CBZ) has been developed. The method is based on the chemiluminescence produced in the reaction of tris(2,2'-bipyridine)ruthenium(III) and CBZ in an acidic medium. The chemiluminescence intensity was enhanced by organic solvents in the reaction system. Under the optimum experimental conditions, the calibration curve was linear over the range 4.0 x 10(-3)-8.6 x 10(-7) mol/L for CBZ. The detection limit (S/N = 3) was 2.5 x 10(-7) mol/L and the relative standard deviation of six replicate measurements was 2.6% for 4.0 x 10(-4) mol/L of CBZ. The possible reaction mechanism were also discussed. The chemiluminescence method was successfully applied to assay the CBZ contents in pharmaceutical tablets.  相似文献   

14.
In this study, a sensitive and rapid method for hydrogen peroxide (H(2)O(2)) determination has been developed with the aid of oxidation decolorization of methyl orange (MO) by using Fenton reactions, because the decolorization extent of MO solution (at the maximum absorption wavelength of 507 nm) is proportion to the concentration of H(2)O(2). Under optimum conditions, this spectrophotometric method for the H(2)O(2) analysis yields a dynamic range of H(2)O(2) concentration from 5.0 x 10(-7) to 1.0 x 10(-4) mol L(-1) (r=0.997) and a detection limit (3 sigma/k) of 2.0 x 10(-7) mol L(-1). This method for the determination of H(2)O(2) (0.04 mmol L(-1)) is able to tolerate the interference from NaCl (0-5.0 mmol L(-1)), Na(2)SO(4) (0-5.0 mmol L(-1)), MgCl(2) (0-5.0 mmol L(-1)), sodium humate (0-0.1 mmol L(-1)), benzene (0-0.2 mmol L(-1)), toluene (0-0.2 mmol L(-1)), chlorobenzene (0-0.2 mmol L(-1)) and chloroform (0-0.2 mmol L(-1)). The analysis results for practical rainwater samples are in good agreement with the classical N,N-diethyl-p-phenylenediamine (DPD) method for H(2)O(2) determination.  相似文献   

15.
A novel method is proposed for the determination of trace amount of oxalic acid in the present article. In 1.0M hydrochloric acid medium, oxalic acid can react with the zirconium(IV) in Zr(IV)-(DBS-arsenazo) complex and replaces the DBS-arsenazo to produce a hyperchromic effect at 520 nm. The hyperchromic degree is proportional to the concentration of the oxalic acid added over a defined range. Based on this property, a new method for the spectrophotometric determination of trace oxalic acid was developed. Beer's law is held over the concentration range of 9.0 x 10(-6) to 5.0 x 10(-4)M for oxalic acid with a correlation coefficient of 0.9995. The apparent molar absorptivity of the method is epsilon520 nm = 1.16 x 10(3)L mol(-1)cm(-1) and the detection limit for oxalic acid is 0.815 microg/mL. The developed method was directly applied to the determination of oxalic acid in tomato samples with satisfactory results.  相似文献   

16.
A rapid and sensitive flow-injection chemiluminescence method is described for the determination of dichloro- and trichloroisocyanuric acids based on the chemiluminescence produced during their reaction with luminol in alkaline medium. The effects of analytical and flow-injection variables on these chemiluminescence systems and determination of both oxidants are discussed. The optimized method yielded 3sigma detection limits of 8x10(-8) and 5x10(-8) mol L(-1) for the sodium dichloroisocyanurate and trichloroisocyanuric acid, respectively. The optimum conditions were found to be as follows: NaOH, 1x10(-1) mol L(-1); luminol, 5x10(-3) mol L(-1); KI, 2x10(-3) mol L(-1) and flow rate, 3.5 mL min(-1).  相似文献   

17.
在酸性介质下,KMnO4可以氧化2-硝基酚产生化学发光,乙二醛对该发光体系有增敏作用。结合流动注射技术,建立了测定2-硝基酚的流动注射化学发光新方法。该方法线性范围为8.0×10-10~5.0×10-6 mol/L,检出限为1.0×10-11mol/L,对1.0×10-7 mol/L的2-硝基酚平行测定11次,相对标准偏差为2.4%。该法已用于实际水样中2-硝基酚的测定。  相似文献   

18.
Glassy carbon electrode (GCE) is covalently modified with aspartic acid (Asp). The modified electrode is used for the simultaneous electrochemical determination of hydroquinone (HQ) and catechol (CC) and shows an excellent electrocatalytical effect on the oxidation of HQ and CC by cyclic voltammetry (CV) in 0.1 mol/L acetate buffer solution (pH 4.5). In differential pulse voltammetric (DPV) measurements, the modified electrode could separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 101 mV though the bare electrode gave a single broad response. A successful elimination of the fouling effect by the oxidized product of HQ on the response of CC has been achieved at the modified electrode. The determination limit of HQ in the presence of 0.1 mmol/L CC was 9.0 x 10(-7) mol/L and the determination limit of CC in the presence of 0.1 mmol/L HQ was 5.0 x 10(-7) mol/L. The proposed method has been applied to the simultaneous determination of HQ and CC in a water sample with simplicity and high selectivity.  相似文献   

19.
Based on catalysis of I- on the decolor reaction between potassium bromate and indigo carmine in the acid medium,and combined with flow injection analysis,a new flow-injection catalytic kinetic spectrophotometric method was found for determination of iodide in sample.The experimental results show that the determination is carried out at temperature of 80℃ and the concentration of H_2SO_4,KBrO_3,and indigo carmine is 1.2 mol/L,1.8×10~(-2) mol/L and 1.0×10~(-4) mol/L respectively,the linear range for the method is 0.50~1.8 mg/L.The detection limit is 0.0022 mg/L.The relative standard deviation is 1.92%.The proposed method was applied to the determination of iodide in troche successfully.The recovery was between 99.2% and 103.6%.  相似文献   

20.
The electrochemical reduction of betamethasone valerate (BV) in a pharmaceutical formulation containing neomycin has been carried out in Britton-Robinson buffer (BRB) (0.04 mol L(-1)) by differential-pulse polarography (DPP). BV exhibits a well-defined irreversible reduction peak at -1.03 V/ref. The influence of pH on the reduction of BV was studied in Britton-Robinson buffer (pH range 1.7-10). A method for the analysis of BV in BRB (0.04 mol L(-1)), which allows quantification over the range 3.9x10(-6)-1.1x10(-4) mol L(-1), was proposed and successfully applied to the determination of BV in tablets with mean recovery and relative standard deviation of 100.81% and 0.45%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号