首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
《Electroanalysis》2003,15(19):1561-1565
A highly selective membrane electrode for the determination of ultratrace amounts of lead was prepared. The PVC membrane electrode based on 2‐(2‐ethanoloxymethyl)‐1‐hydroxy‐9,10‐anthraquinone (AQ), directly coated on graphite, exhibits a good Nernstian response for Pb(II) ions over a very wide concentration range (1.0×10?7–1.0×10?2 M) with a limit of detection of 8.0×10?8 M. It has a fast response time of ca. 10 s and can be used over a period 2 months with good reproducibility (SD=±0.2 mV). The electrode revealed a very good selectivity respect to common alkali, alkaline earth, transition and heavy metal ions and could be used in the pH range of 3.5–6.8. It was used as an indicator electrode in potentiometric titration of lead ions with chromate and oxalate, and in indirect determination of lead in spring water samples.  相似文献   

2.
A new podand of 1,1′‐thia‐bis‐[1‐(chloroethan‐2‐acetamid‐α‐oxy)] naphtol was synthesized and used as a suitable carrier for Ag+ PVC membrane electrode. The electrode exhibited linear response with a Nernstian slope of (59.5±0.8 mV/decade) within a wide concentration range of 1.0×10?7 to 1.5×10?2 mol L?1 silver ions. The electrode had a fast response time of <10 s and detection limit of 8.6×10?8 mol L?1 with a working pH range from 3.7 to 9.0. The electrode was highly selective for Ag(I) ions over a large number of cations such as alkali, alkaline earth, and heavy metal ions. The proposed sensor has been applied as an indicator electrode for indirect determination of vitamin B1 in tablets by determination of Cl? ions in this compound with a standard solution of Ag(NO3).  相似文献   

3.
《Analytical letters》2012,45(11):2169-2181
ABSTRACT

A new PVC membrane for zinc ions based on DBDA15C4 as membrane carrier was prepared. The electrode shows a linear stable response over a wide concentration range (5.0 × 10?5-1.0 × 10?1 M) with a slope of 22 mV/decade and a limit of detection of 3.0 × 10?5 M (2.0 μg/ml). It has a very short response time of less than 5 s and can be use for at least 11 months without any divergence in potential. The zinc ion-selective electrode exhibited very good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions and could be used in a pH range 1.5-7.0. It was successfully applied for the direct determination of zinc in a pharmaceutical sample and, as an indicator electrode, in potentiometric titration of Zn2+ ions.  相似文献   

4.
《Analytical letters》2012,45(17):2838-2852
Abstract

2-Ethoxy-1-ethoxycarbonyl-1,2-dihydroquinoline (EED) was found to be a suitable neutral ionophore for the preparation of a highly selective samarium (Sm)(III) membrane sensor. Poly vinylchloride (PVC)–based membranes of EED with sodium tetraphenyl borate (NaTPB) as an anionic additive and dibutylphthalate (DBP), nitrobenzene (NB), and acetophenone (AP) as plasticizing solvent mediators were prepared and investigated as Sm(III) sensors. The sensor exhibited a Nernstian response over a concentration range of 1.0 × 10?6 to 1.0 × 10?2 M, with a detection limit of 5.0 × 10?7 M. The best performance was achieved with a membrane composition of 30% PVC, 66% dibutyl phthalate (DBP), 2% EED, and 2% sodium tetraphenyl borate (NaTPB). It has a very short response time, in the whole concentration range (~10s), and can be used for at least 10 weeks. The proposed electrode shows a very good selectivity toward Sm(III) ions over a wide variety of cations, including alkali, alkaline earth, transition-metal, and heavy-metal ions. The sensor was applied to the determination of Sm ions in binary mixtures.  相似文献   

5.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

6.
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade?1, and a detection limit of 4.0 × 10?7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.  相似文献   

7.
《Analytical letters》2012,45(5):902-916
Abstract

A novel Pr(III) ion‐selective polyvinyl chloride (PVC) membrane sensor, based on N,N‐bis(α‐methylsalicylidene)diethylenetriamine (BMT) as a new ionophore, has been prepared and studied. The electrode showed good selectivity for Pr(III) ion with respect to most common cations, including alkali, alkaline earth, transition, and heavy metal ions. This electrode has a wide linear dynamic range from 1.0×10?6 to 1.0×10?2 M with a Nernstian slope of 19.8±0.2 mV per decade and a low detection limit of 6.5×10?7 M, in the pH range of 3.0–8.4, while response time was rapid (<15 s). As far as applications of the recommended sensor are concerned, first it was employed as an indicator electrode in the potentiometric titration of Pr(III) ions with EDTA. Second, it was effectively applied to the determination of concentration of Pr(III) ions in soil and sediment samples, and validation with CRMs.  相似文献   

8.
《Electroanalysis》2005,17(10):895-900
A highly sensitive and selective membrane electrode with 9‐crown‐3 derivative (CD) as ionophore, potassium tetrakis‐(p‐chlorophenyl) borate as anionic additive (KTB), acetophenone (AP) as solvent mediator was prepared and investigated as a Be(II) sensor. The best performance was observed with the membrane having the percent ratio 30% PVC: 8% CD: 6% KTB: 56% Acetophenone. The poly(vinyl chloride) PVC membrane containing 9‐crown‐3 derivative (CD) directly coated on a graphite electrode, shows a Nernstian response for Be(II) ions over a very wide concentration range (1.0×10?1?1.0×10?7 M) with a detection limit of 8.0×10?8 M (ca. 0.72 ng/mL). It has a fast response time of ca. 20 s and can be used for at least 10 weeks without any major deviation in potential. The proposed sensor exhibits very good selectivity with respect to common alkali, alkaline earth, transition and heavy metal ions. The proposed sensor was used as end point indicator electrode in the titration of Be(II) ions with EDTA. It was also applied to determination of Be(II) in real sample.  相似文献   

9.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   

10.
《Analytical letters》2012,45(2):298-311
Abstract

A polyvinyl chloride (PVC) based membrane sensor for terbium ions was prepared by employing Hematoporphyrin (HP) as an ionophore. The sensor revealed a very good selectivity (expect for the Fe3+ion) with respect to common alkali, alkaline earth and heavy metal ions. The plasticized membrane electrode exhibits a Nernstian response for Tb3+ ions over a wide concentration range (1.0 × 10?6 ? 1.0 × 10?2 M) with a slope of 19.8±0.3 mV per decade and low detection limit of 7.4 × 10?7 M. The developed sensor was used in determination of F? in mouth wash preparation sample.  相似文献   

11.
《Electroanalysis》2005,17(20):1828-1834
A recently synthesized azao‐containing Schiff's base N,N′‐adipylbis(5‐phenylazo salicylaldehyde hydrazone) was used as a suitable neutral ion carrier in construction of a highly selective La3+‐PVC membrane electrode. The electrode exhibits a Nernstian response with a slope of 19.4 mV decade?1 over a wide concentration range (1.0×10?6–1.0×10?2 M) and a limit of detection of 4.0×10?7 M (0.05 ppm). The electrode possesses a fast response time of ca. 10 s and can be used for at least 3 months without observing any deviation. The proposed electrode revealed excellent selectivity for La3+ over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–8.0. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of La3+ ions with EDTA and in determination of F? ion in some pharmaceutical preparations.  相似文献   

12.
《Analytical letters》2012,45(14):2710-2726
Abstract

A PVC membrane electrode for dysprosium(III) [Dy(III)] ions was constructed, having its basis on benzoxazoleguanidine (BG) as a suitable ionophore. The sensor presents a linear dynamic range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 19.5 ± 0.4 mV decade?1 and a detection limit of 4.7 × 10?7 M. The response time is quick (less than 10 s). It can be used in the pH range of 3.3–8.4, and its duration is at least 2 mo without any considerable, noticeable potential divergence. The recommended sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, some transition, and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Dy(III) ions with EDTA. The membrane sensor also applied to the determination of concentration of Dy(III) ions in soil and sediment samples. Validation with certified reference materials (CRMs) was also carried out.  相似文献   

13.
Poly(vinyl chloride) (PVC)-based membrane of pentathia-15-crown-5 exhibits good potentiometric response for Hg2+ over a wide concentration range (2.51 × 10−5 to 1.00 × 10−1 mol dm−3) with a slope of 32.1 mV per decade of Hg2+ concentration. The response time of the sensor is as fast as 20 s. The electrode has been used for a period of six weeks and exhibits fairly good discriminating ability towards Hg2+ in comparison to alkali, alkaline and some heavy metal ions. The electrode can be used in the pH range from 2.7 to 5.0.  相似文献   

14.
《Analytical letters》2012,45(3):495-506
Abstract

A Dy(III) ion‐selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrix membrane containing a new asymmetrical Schiff's base [(E)‐N‐(2‐hydroxybenzylidene)benzohydraide] or BBH as a neutral carrier, sodium tetraphenyl borate (NaTPB) as an anionic excluder and nitrobenzene (NB) as a plasticizing solvent mediator. The membrane sensor displays linear potential response in the concentration range of 1.0×10?2–1.0×10?6 M of Dy(III). The electrode exhibits a nice Nernstian slope of 20.1±0.8 mV/decade in the pH range of 3.0–8.0. The sensor has a relatively short response time in whole concentration ranges (<20 s). The detection limit of the proposed sensor is 8.0×10?7 M (~128 ng/mL), and it can be used over a period of six weeks. The selectivity of the proposed sensor with respect to other cations, (alkali, alkaline earth, transition and heavy metal ions) and especially lanthanid ions, is excellent. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of Dy(III) with EDTA.  相似文献   

15.
《Electroanalysis》2006,18(12):1186-1192
A PVC membrane electrode using [Bzo2Me2Ph2(16)hexaeneN4] ( I ) as ionophore, oleic acid as lipophilic additive and o‐nitrophenyloctyl ether as plasticizer has been investigated as Zn(II)‐selective electrode. The membrane incorporating 34.9% (w/w) PVC, 2.3% I , 4.7% OA and 58.1% o‐NPOE gave linear response over the concentration range 2.82×10?6?1.0×10?1 M with a Nernstian slope of 28.5±0.2 mV/decade of concentration with a detection limit of 2.24×10?6 M (0.146 ppm) and showed a response time of less than 10 s and could be used in pH range 2.5–8.5. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully used as an indicator electrode in potentiometric titration of zinc ions with EDTA and for determination of zinc in real samples.  相似文献   

16.
《Analytical letters》2012,45(3):615-629
Abstract

In this study, a new ion-selective electrode for Sm3+ is described, illustrating 2-[(E)-1-(1H-pyrrol-2-yl)methylidene]-1-hydrazinecarbothioamide (PMH) in a poly(vinylchloride) (PVC) membrane with nitrobenzene (NB) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic additive. The proposed sensor exhibited a Nernstian response for Sm3+ ions over a wide concentration range between 1.0 × 10?2 and 1 × 10?6 M, with a detection limit of 5.2 × 10?7 M in the pH range of 4.2–8.5. Moreover, the sensor displayed the Nernstian slope of 19.8 ± 0.3 mV per decade, having a fast response time within 10 s over the entire concentration range. This electrode presented very good selectivity and sensitivity toward the Sm3+ ions over a wide variety of cations, including alkali, alkaline earth, transition-metal, and heavy-metal ions. It was used as an indicator electrode in the potentiometric titration of Sm3+ ions with EDTA. The membrane sensor was also applied to the determination of fluoride ions in mouthwash samples.  相似文献   

17.
A new tin complex namely tetracyclohexyl tin(IV) (TCHT) was synthesized and used as the ion carrier for the construction of a highly selective salicylate sensor. This sensor shows a Nernstian response to salicylate ions over a very wide concentration (1.0 × 10?7–1.0 × 10?1 M) in a pH range of 5.5–10.5. The optimum selectivity and response could be obtained for a membrane incorporating 30% PVC, 61% BA, 3% of cationic additive (HTAB) and 6% of TCHT. The response time of the electrode is very short in the whole concentration range (15 s). The electrode also shows an excellent discriminating ability for salicylate ions with respect to the most common organic and inorganic anions including chloride, sulfate, nitrate, nitrite, cyanide, sulfite, iodide, thiocyanate, phosphate, acetate, oxalate, citrate, and tartarate ions. The detection limit of the proposed sensor is 8.0 × 10?8 M. The electrode was successfully used for determining the concentration of salicylate ion in synthetic serums.  相似文献   

18.
《Analytical letters》2012,45(1):17-28
ABSTRACT

A PVC membrane electrode for Pb2 ions based on tetraphenylporphyrin was prepared. The sensor exhibits a Nernstian response for lead ions over a wide concentration range (1.0 x 10?5-1.0 x 10?2 M). The limit of detection is 8.5 x 10?6M. It has a response time of 15 s and can be used for at least three months without any divergence in potential. The proposed electrode shows a fairly good discriminating ability towards Pb2 ion in comparison to some alkali, alkaline earth, transition and heavy metal ions. The electrode can be used in the pH range 5.0 to 7.5. It was used as an indicator electrode in potentiometric titration of lead ion.  相似文献   

19.
A potentiometric sensor for lead(II) ions based on the use of 1,4,8,11‐tetrathiacyclotetradecane (TTCTD) as a neutral ionophore and potassium tetrakis‐(p‐chlorophenyl)borate as a lipophilic additive in plasticized PVC membranes is developed. The sensor exhibits linear potentiometric response towards lead(II) ions over the concentration range of 1.0×10?5–1.0×10?2 mol L?1 with a Nernstian slope of 29.9 mV decade?1 and a lower limit of detection of 2.2×10?6 mol L?1 Pb(II) ions over the pH range of 3–6.5. Sensor membrane without a lipophilic additive displays poor response. The sensor shows high selectivity for Pb(II) over a wide variety of alkali, alkaline earth and transition metal ions. The sensor shows long life span, high reproducibility, fast response and long term stability. Validation of the method by measuring the lower limit of detection, lower limit of linear range, accuracy, precision and sensitivity reveals good performance characteristics of the proposed sensor. The developed sensor is successfully applied to direct determination of lead(II) in real samples. The sensor is also used as an indicator electrode for the potentiometric titration of Pb(II) with EDTA and potassium chromate. The results obtained agree fairly well with data obtained by AAS.  相似文献   

20.
《Electroanalysis》2004,16(21):1771-1776
In this work a dysprosium [Dy(III)]‐selective solvent polymeric membrane sensor based on N,N‐bis(pyrrolidene) benzne‐1,2‐diamine, poly(vinyl chloride)(PVC), the plasticizer benzylacetate (BA), and anionic site is described. This sensor responds to Dy(III) activity in a linear range from 1.0×10?5 to 1.0×10?1 M, with a slope of 20.6±0.2 mV per decade and a detection limit of 6.0×10?6 M at the pH range of 3.5–8.0. It has a fast response time of<20 s in the entire concentration range, and can be used for at least 2 months without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in the potentiometric titration of fluoride ions and in determination of concentration of F ions in some mouth washing solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号