1.
The components (H3PO4, HNO3, CH3COOH and water) in an etchant solution have been accurately measured in an on-line manner using near-infrared (NIR) spectroscopy by directly illuminating NIR radiation through a Teflon line. In particular, the spectral features according to the change of H3PO4 or HNO3 concentrations were not mainly from NIR absorption themselves, but from the perturbation (or displacement) of water bands; therefore, the resulting spectral variations were quite similar to each other. Consequently partial least squares (PLS) prediction selectivity among the components should be the most critical issue for continuous on-line compositional monitoring by NIR spectroscopy. To improve selectivity of the calibration model, we have optimized the calibration models by finding selective spectral ranges with the use of moving window PLS. Using the optimized PLS models for each component, the resulting prediction accuracies were substantially improved. Furthermore, on-line prediction selectivity was evaluated by spiking individual pure components step by step and examining the resulting prediction trends. When optimized PLS models were used, each concentration was selectively and sensitively varied at each spike; meanwhile, when whole or non-optimized ranges were used for PLS, the prediction selectivity was greatly degraded. This study verifies that the selection of an optimal spectral range for PLS is the most important factor to make Teflon-based NIR measurements successful for on-line and real-time monitoring of etching solutions.  相似文献   

2.
Kim J  Hwang J  Chung H 《Analytica chimica acta》2008,629(1-2):119-127
Both near-infrared (NIR) and Raman spectroscopy have been studied for the quantitative measurement of components (H(3)PO(4), HNO(3), and CH(3)COOH) in an etchant solution and the corresponding prediction robustness has been evaluated. Both measurements were accomplished by illuminating radiation directly through a Teflon tube. Raman spectral features of each component were much clearer and more selective than those observed in the NIR spectrum. Especially, NIR spectral variation pertinent to H(3)PO(4) and HNO(3) were mostly based on the displacement and perturbation of water bands rather than due solely to NIR absorption. Therefore, the resulting spectral variations were not highly specific. When the validation set contained minor spectral variations resulting from a slight instrumental change, NIR prediction performance for all three components degraded substantially by showing obvious prediction bias. However, the accuracies of Raman predictions were maintained. Since partial least squares (PLS) models for each component were built using NIR spectra of poor specificity with broadly overlapping features, even minor spectral differences introduced by instrumental variations sensitively influenced the prediction performance of the NIR models. Overall, the selectivity (specificity) of a targeting spectroscopic method should be considered critically to secure prediction robustness for monitoring components in an etchant solution.  相似文献   

3.
The ability to monitor etching solutions using a spectroscopy directly through existing Teflon lines in electronic industries is highly beneficial and offers many advantages. A monitoring method was developed using near-infrared (NIR) measurements with Teflon tubing as a sample container for the quantification of components in the indium-tin-oxide (ITO) etching solution composed of hydrochloric acid (HCl), acetic acid (CH3COOH) and water. Measurements were reproducible and it was possible to use the same calibration model for different Teflon tubings. Even though partial least squares (PLS) calibration performance was slightly degraded for Teflon cells when compared to quartz cells of the similar pathlength, the calibration data correlated well with reference data. The robustness of Teflon-based NIR measurement was evaluated by predicting the spectra of 10 independent samples that were collected using five different Teflon tubes. Although, two Teflon tubes were visually less transparent than the other three, there was no significant variation in the standard error of predictions (SEPs) among the five Teflon tubes. Calibration accuracy was successfully maintained and highly repeatable prediction results were achieved. This study verifies that a Teflon-based NIR measurement is reliable for the monitoring of etching solutions and it can be successfully integrated into on-line process monitoring.  相似文献   

4.
Multivariate regression based on partial least squares (PLS2) was applied to estimating one spectral dataset from another set having an intrinsic relationship with each other. An estimation was successfully carried out between mid-infrared (IR) spectra in the range of 2980 - 3800 cm(-1) and that of near-infrared (NIR) spectra in the range of 6000 - 7500 cm(-1) for hexafluoroisopropanol (HFIP)-water mixtures. The result demonstrates that, after building a suitable regression model, not only NIR spectra, but also well-resolved IR spectra of HFIP-water mixture can be estimated properly in this way. The use of IR and NIR spectroscopy together with PLS2 regression will not only alleviate laborious and costly measurements, but also open a way to provide easier assignments of generally weak and highly overlapped NIR spectral bands.  相似文献   

5.
Wastes and by-products of the onion-processing industry pose an increasing disposal and environmental problem and represent a loss of valuable sources of nutrients. The present study focused on the production of vinegar from worthless onions as a potential valorisation route which could provide a viable solution to multiple disposal and environmental problems, simultaneously offering the possibility of converting waste materials into a useful food-grade product and of exploiting the unique properties and health benefits of onions. This study deals specifically with the second and definitive step of the onion vinegar production process: the efficient production of vinegar from onion waste by transforming onion ethanol, previously produced by alcoholic fermentation, into acetic acid via acetic fermentation. Near-infrared spectroscopy (NIRS), coupled with multivariate calibration methods, has been used to monitor the concentrations of both substrates and products in acetic fermentation. Separate partial least squares (PLS) regression models, correlating NIR spectral data of fermentation samples with each kinetic parameter studied, were developed. Wavelength selection was also performed applying the iterative predictor weighting–PLS (IPW-PLS) method in order to only consider significant spectral features in each model development to improve the quality of the final models constructed. Biomass, substrate (ethanol) and product (acetic acid) concentration were predicted in the acetic fermentation of onion alcohol with high accuracy using IPW-PLS models with a root-mean-square error of the residuals in external prediction (RMSEP) lower than 2.5% for both ethanol and acetic acid, and an RMSEP of 6.1% for total biomass concentration (a very satisfactory result considering the relatively low precision and accuracy associated with the reference method used for determining the latter). Thus, the simple and reliable calibration models proposed in this study suggest that they could be implemented in routine applications to monitor and predict the key species involved in the acetic fermentation of onion alcohol, allowing the onion vinegar production process to be controlled in real time.  相似文献   

6.
采用近红外光谱(NIRS)透射法对红花罐组式逆流提取过程中羟基红花黄色素A(Hydroxysafflor yellow A,HSYA)的含量进行快速无损的测定.在红花逆流提取过程中,以高效液相色谱法(HPLC)为对照分析方法,测定提取液中羟基红花黄色素A的含量,运用偏最小二乘(PLS)法建立NIR光谱与羟基红花黄色素A的HPLC分析值之间多元校正模型,并对逆流提取过程的未知样本进行含量预测.校正模型相关系数达到0.982,预测相关系数达到0.965,RMSEC和RMSEP分别为0.053和0.075,RSEC和RSEP分别为3.96%和5.25%.结果表明,NIRS可以作为一种准确、快速、无损的检测方法用于检测中药逆流提取过程有效成分含量变化规律.  相似文献   

7.
The aim of this study was to investigate the changes in carbohydrate components and the crystalline structure in hemp bast fibers by adding ethyl acetate to acetic acid/water pulping processes. It was found that ethyl acetate added to acetic acid/water process had a positive effect on yield, viscosity and carbohydrate components in pulp. It was assumed that the delignification ratio increased by adding ethyl acetate to aqueous acetic acid pulping. Xylose content in hemp bast fibers was affected more negatively in the ethyl acetate/acetic acid/water process than in the acetic acid/water one. Crystallinity and crystallite size were higher in pulp sample obtained by the acetic acid/water process without ethyl acetate.  相似文献   

8.
Production batch samples of paracetamol tablets and specially prepared out-of-specification batches covering the range 90-110% of the stated amount (500 mg) were analysed by the BP official UV assay and by NIR transmittance spectroscopy. NIR measurements were made on 20 intact tablets from each batch, scanned five times each (10 min measurement time per batch) over the spectral range 6000-11,520 cm-1. An average spectrum was calculated for each batch. Partial least squares (PLS) regression models were set up using a calibration set (20 batches) between the NIR response and the reference tablet paracetamol content (UV). Various pre-treatments of the spectra were examined; the smallest relative standard error of prediction (0.73%) was obtained using the first derivative of the absorbance over the full spectrum. Only two principal components were required for the PLS model to give a good relationship between the spectral information and paracetamol content. Applying this model to the validation set (15 batches) gave a mean bias of -0.08% and a mean accuracy of 0.59% with relative standard deviations of 0.75 and 0.44%, respectively. The proposed method is non-destructive and therefore lends itself to on-line/at-line production control purposes. The method is easy to use and does not require a knowledge of the mass of the tablets.  相似文献   

9.
Vibrational energy relaxation of the carbonyl CO stretching modes of CH3COOD and CD3COOD in D2O is studied by frequency-resolved infrared pump-probe spectroscopy. The spectral change caused by the vibrational excitation includes two dynamical components with the time constants of 450 and 980 fs for CH3COOD and 390 and 930 fs for CD3COOD. The two dynamical components exhibit different spectral properties. There are two species of acetic acid forming different complexes with solvent water molecules. The time constants are almost the same for CH3COOD and CD3COOD, suggesting that the vibrational energy deposited to the carbonyl group is first distributed among vibrational modes not related to the methyl group.  相似文献   

10.
The structures of acetic acid (AA), trifluoroacetic acid (TFA), and their aqueous mixtures over the entire range of acid mole fraction xA have been investigated by using large-angle X-ray scattering (LAXS) and NMR techniques. The results from the LAXS experiments have shown that acetic acid molecules mainly form a chain structure via hydrogen bonding in the pure liquid. In acetic acid-water mixtures hydrogen bonds of acetic acid-water and water-water gradually increase with decreasing xA, while the chain structure of acetic acid molecules is moderately ruptured. Hydrogen bonds among water molecules are remarkably formed in acetic acid-water mixtures at xA相似文献   

11.
Near-infrared (NIR) and mid-infrared (MIR) spectroscopy have been compared and evaluated for the determination of the distillation property of kerosene with the use of partial least squares (PLS) regression. Since kerosene is a complex mixture of similar hydrocarbons, both spectroscopic methods will be best evaluated with this complex sample matrix. PLS calibration models for each percent recovery temperature have been developed by using both NIR and MIR spectra without spectral pretreatment. Both methods have shown good correlation with the corresponding reference method, however NIR provided better calibration performance over MIR. To rationalize the improved calibration performance of NIR, spectra of the same kerosene sample were continuously collected and the corresponding spectral reproducibility was evaluated. The greater spectral reproducibility including signal-to-noise ratio of NIR led to the improved calibration performance, even though MIR spectroscopy provided more qualitative spectral information. The reproducibility of measurement, signal-to-noise ratio, and richness of qualitative information should be simultaneously considered for proper selection of a spectroscopic method for quantitative analysis.  相似文献   

12.
In this work the vapor–liquid equilibria for nine binary mixtures (methanol + acetic acid, methanol + methyl acetate, methanol + water, methyl acetate + acetic acid, water + acetic acid, ethyl acetate + acetic acid, ethanol + acetic acid, ethanol + ethyl acetate and ethanol + water) at subatmospherical pressure (580 mmHg) is presented. Peng–Robinson Stryjek–Vera equation of state coupled with the Wong–Sandler mixing rules were used for predicting phase equilibria of these mixtures. The measurements were developed using an apparatus with recirculation that can also be employed for liquid–vapor equilibrium with chemical reaction.  相似文献   

13.
Near-infrared (NIR) spectroscopy, in combination with chemometrics, enable the analysis of raw materials without time-consuming sample preparation methods. The aim of our work was to estimate critical parameters in the analytical specification of oxytetracycline, and consequently the development of a method for quantification and qualification of these parameters by NIR spectroscopy. A Karl Fischer (K.F.) titration to determine the water content, a colorimetric assay method, and Fourier transform-infrared (FT-IR) spectroscopy to identify the oxytetracycline base, were used as reference methods, respectively. Multivariate calibration was performed on NIR spectral data using principal component analysis (PCA), partial least-squares (PLS 1) and principal component regression (PCR) chemometric methods. Multivariate calibration models for NIR spectroscopy have been developed. Using PCA and the Soft Independent Modelling of Class Analogy (SIMCA) approach, we established the cluster model for the determination of sample identity. PLS 1 and PCR regression methods were applied to develop the calibration models for the determination of water content and the assay of the oxytetracycline base. Comparing the PLS and PCR regression methods we found out that the PLS is better established by NIR, especially as the spectroscopic data (NIR spectra) are highly collinear and there are many wavelengths due to non-selective wavelengths. The calibration models for NIR spectroscopy are convenient alternatives to the colorimetric method and to the K.F. method, as well as to FT-IR spectroscopy, in the routine control of incoming material.  相似文献   

14.
By mid-IR analysis, mixtures of stearic acid, a paraffinic compound and a fluorinated compound were analyzed using attenuated total reflection (ATR) spectroscopy and reflection-absorption infrared spectroscopy (RAIRS). The precision of the partial least square (PLS) models created for each of these two techniques were compared in order to work out a quality control process of the mixtures which are involved in mechanochemical coating technology. We obtained a good relationship between spectral data and concentration with ATR spectroscopy. However, RAIRS spectroscopy allows to observe the affinity of long-chain organic acids for steel surfaces, and to determine the actual composition of coatings.  相似文献   

15.
阿司匹林合成过程中所采集的阿司匹林、水杨酸和乙酸酐的拉曼光谱存在交迭现象,很难从光谱数据中分离各组分含量。根据反应体系的组成和浓度配制样本溶液并采集拉曼光谱,运用多种方法对光谱进行预处理结合偏最小二乘法(PLS)对混合体系中阿司匹林、乙酸酐和水杨酸3组分浓度和光谱矩阵建立回归模型,对回归结果进行比较,根据交互验证均方根误差RMSECV,预测相关系数帮,预测均方根误差RMSEP。结果表明预处理方案可以有效降低基线漂移对预测精度的影响,根据Q值检验法和严检验法确定经矢量归一+Savitzky-Golay五点二次平滑一阶卷积求导+均值中心化对拉曼光谱预处理,PLS主成分选4,交互验证选用“逐一法”可时阿司匹林反应体系3组分进行同时测定,此训练集为阿司匹林合成体系的拉曼光谱在线监测提供了良好的数据支持。  相似文献   

16.
In this article, a methacrylate-based spiropyran-containing copolymer was used as a colorimetric sensor to identify multiple metal ions simultaneously. Through UV-vis absorption spectroscopy, the relative binding affinity of merocyanine to each metal ion was investigated by displacement studies of a bound metal ion with a second metal ion of a higher binding affinity. We also show that because each metal ion gives rise to a distinct spectral response, partial least-squares discriminant analysis (PLS-DA) can be used to analyze the UV-vis absorbance spectra to identify the two metal ions that are present in solution at varying concentrations simply by dipping a coated polymer substrate into solution after irradiation. Partial least-squares regression analysis (PLS) was used to determine the metal ions in solution for several binary mixtures quantitatively. We also demonstrate that the quantitative determination depends on the relative binding preference of merocyanine to each metal ion.  相似文献   

17.
This paper proposes an analytical method for simultaneous near-infrared (NIR) spectrometric determination of α-linolenic and linoleic acid in eight types of edible vegetable oils and their blending. For this purpose, a combination of spectral wavelength selection by wavelet transform (WT) and elimination of uninformative variables (UVE) was proposed to obtain simple partial least square (PLS) models based on a small subset of wavelengths. WT was firstly utilized to compress full NIR spectra which contain 1413 redundant variables, and 42 wavelet approximate coefficients were obtained. UVE was then carried out to further select the informative variables. Finally, 27 and 19 wavelet approximate coefficients were selected by UVE for α-linolenic and linoleic acid, respectively. The selected variables were used as inputs of PLS model. Due to original spectra were compressed, and irrelevant variables were eliminated, more parsimonious and efficient model based on WT-UVE was obtained compared with the conventional PLS model with full spectra data. The coefficient of determination (r2) and root mean square error prediction set (RMSEP) for prediction set were 0.9345 and 0.0123 for α-linolenic acid prediction by WT-UVE-PLS model. The r2 and RMSEP were 0.9054, 0.0437 for linoleic acid prediction. The good performance showed a potential application using WT-UVE to select NIR effective variables. WT-UVE can both speed up the calculation and improve the predicted results. The results indicated that it was feasible to fast determine α-linolenic acid and linoleic acid content in edible oils using NIR spectroscopy.  相似文献   

18.
This paper presents a new approach to near-infrared spectral (NIR) data analysis that is based on independent component analysis (ICA). The main advantage of the new method is that it is able to separate the spectra of the constituent components from the spectra of their mixtures. The separation is a blind operation, since the constituent components of mixtures can be unknown. The ICA based method is therefore particularly useful in identifying the unknown components in a mixture as well as in estimating their concentrations. The approach is introduced by reference to case studies and compared to other techniques for NIR analysis including principal component regression (PCR), multiple linear regression (MLR), and partial least squares (PLS) as well as Fourier and wavelet transforms.  相似文献   

19.
A method is described for measuring the concentrations of both glucose and glutamine in binary mixtures from near infrared (NIR) absorption spectra. Spectra are collected over the range from 5000–4000/cm (2.0–2.5μm) with a 1-mm optical path length. Glucose absorbance features at 4710, 4400, and 4300/cm and glutamine features at 4700, 4580, and 4390/cm provide the analytical information required for the measurement. Multivariate calibration models are generated by using partial least squares (PLS) regression alone and PLS regression combined with a preprocessing digital Fourier filtering step. The ideal number of PLS factors and spectral range are identified separately for each analyte. In addition, the optimum Fourier filter parameters are established for both compounds. The best overall analytical performance is obtained by combining Fourier filtering and PLS regression. Glucose measurements are established over the concentration range from 1.66–59.91 mM, with a standard error of prediction (SEP) of 0.32 mM and a mean percent error of 1.84%. Glutamine can be measured over the concentration range from 1.10–30.65 mM with a SEP of 0.75 mM and a mean percent error of 6.67%. These results demonstrate the analytical utility of NIR spectroscopy for monitoring glucose and glutamine levels in mammalian and insect cell cultures.  相似文献   

20.
Propoxur (Baygon®) is an insecticide with a broad spectrum of activity and a very low order of mammalian toxicity. Radiosynthesis of propoxur was performed by the reaction of acetyl-114C chloride and sodium azide to produce methyl isocyanate which then reacted with o-isopropoxyphenol at 100°C. A two compartment reaction tube with a break seal was utilized. Chromatographic procedures for isolating the N-methylcarbamates from their reaction mixtures are reported. Acetyl-1–14C chloride was prepared from thionyl chloride and sodium acetate-1–14C. Grignard reaction between methyl iodide and carbon –14 dioxide yielded acetic acid –14C which was neutralized by sodium hydroxide solution to give sodium acetate 1-14C.  相似文献   