首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 828 毫秒
1.
The abuse of synthetic esters of natural steroids such as testosterone and estradiol in cattle fattening and sports is hard to detect via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. An interesting alternative can be provided by the analysis of the administered synthetic steroids themselves, i.e., the analysis of intact steroid esters in hair by liquid chromatography tandem mass spectrometry (LC/MS/MS). However, retrospective estimation of the application date following a non-compliant finding is hindered by the complexity of the kinetics of the incorporation of steroid esters in hair. In this study, the incorporation of intact steroid esters in hair following pour-on treatment has been studied and critically compared with results from intramuscular treatment. To this end animals were pour-on treated with a hormone cocktail containing testosterone cypionate, testosterone decanoate and estradiol benzoate in different carriers. The animals were either treated using injection and pour-on application once or three times having 1 week between treatments using injection and pour-on application. Animals were slaughtered from 10–12 weeks after the last treatment. Both hair and blood plasma samples were collected and analysed by LC/MS/MS. From the results, it is concluded that after single treatment the levels of steroid esters in hair drop to CCβ levels (5–20 μg/kg) after 5–7 weeks. When treatment is repeated two times, the CCβ levels are reached after 9–11 weeks. Furthermore, in plasma, no steroid esters were detected; not even at the low microgramme per litre level but—in contrast with the pour-on application—after i.m. injection, significant increase of 17β-testosterone and 17β-estradiol were observed. These observations suggest that transport of steroid esters after pour-on application is not only performed by blood but also by alternative fluids in the animal so probably the steroid esters are already hydrolysed and epimerized before entering the blood.  相似文献   

2.
3.
The effect of three sample pre-treatment steps, washing, cutting and grinding on the determination of steroid esters in hair is studied. The study is performed by using hair samples obtained after pour-on application of steroid esters to bovine calves. After sample pre-treatment the hair is treated with a mild reducing agent [tris(2-carboxyethyl)phosphine hydrochloride] to extract the steroid esters. After a solid-phase extraction clean-up step the extracts are analysed by using liquid chromatography combined with triple–quadrupole mass spectrometric detection. For the washing step the use of non-organic washing solvents like (warm) water and a solution of 0.1% sodium dodecyl phosphate and organic solutions containing different percentages of methanol are tested. By using the non-organic solvents and the organic solvents with a percentage of methanol <20% the recovery results are as good as the results obtained without washing the hair. Cutting the hair samples increases the analyte recoveries of incurred steroid esters by 20% compared to the non-cut hair. The analyte recoveries of cut hair samples are about 60–80% that of ground hair samples. The obtained surface expansion of hair samples by grinding proves to be necessary in order to achieve the highest possible analyte yields. Finally the use of pressurised liquid extraction (PLE) for the extraction of steroid esters from plain (no washing, cutting or grinding) hair is investigated. The first results show lower (up to 40%) extraction recoveries in comparison with the classical solvent extraction procedures. If the limit of detection requirement is met, PLE may be an alternative for extracting large numbers of hair samples due to the short sample treatment procedure involved.  相似文献   

4.
Detection of testosterone,nandrolone and precursors in horse hair   总被引:1,自引:0,他引:1  
Growing interest among several horse-breeder associations has initiated the development of a screening procedure to test for anabolic agents in hair, which has the advantage over blood and urine specimens of allowing long-term detection. An analytical method was established to monitor in tails or manes several anabolic substances available as veterinary medicines or as so-called nutritional supplements (clenbuterol, different esters or prohormones of nandrolone and testosterone). The analytical procedure to detect steroids in hair samples consists of the following steps: decontamination of the hair strand or segment with methanol/water (1:1), milling, extraction of the hair material in an ultrasonic bath using methanol, purification by liquid–liquid extraction (n-pentane/methanol, 25:1) and HPLC cleanup, derivatisation of the relevant LC fractions with MSTFA, and measurement using GC-MS/MS technique. The first objective of our study was the detection of exogenous nandrolone (nortestosterone, NT) in the horse hair; therefore nandrolone-associated compounds [nandrolone dodecanoate administered intramuscularly (i.m.) and a mixture of 4-estrenediol and 4-estrenedione, transdermal] were administered to four geldings. The highest concentrations of NT following i.m. treatment were measured after 10 days in a 2-cm hair segment (up to 18 pg/mg); NT was detectable for up to 120 days and in some cases up to 330 days in tail hair (limit of detection 0.3 pg/mg). Following transdermal application, nandrolone as well as the administered prohormones were identified in tail and mane until the latest sampling at 3 months. Furthermore, untreated stallions (128) were investigated to estimate the range of endogenous levels of NT and testosterone (T) in hair. Maximum values of 3 pg/mg (NT) and 1 pg/mg (T) were quantified originating from endogenous formation in the male horse. Additionally, a possible relationship between steroid concentrations in hair specimens and the age of stallions was appraised. NT and T were not detected in hair samples of control geldings. Following nandrolone treatment of geldings, highest values in hair exceeded the endogenous amount detected in untreated stallions. Therefore comparison of concentrations measured in control samples with the estimated endogenous levels could give a clue to exogenous application in cases of abnormally high amounts of NT or T. The possibility of the evaluation of threshold values is discussed as a means to verify an exogenous administration of NT and T in hair samples. Furthermore, the detection of a synthetic substance in hair, e. g. the parent steroid ester by itself, would be unequivocal proof of an exogenous origin of NT or T and the previous medication of the stallion.  相似文献   

5.
Biological tests can be used to screen samples for large groups of compounds having a particular effect, but it is often difficult to identify a specific compound when a positive effect is observed. The identification of an unknown compound is a challenge for analytical chemistry in environmental analysis, food analysis, as well as in clinical and forensic toxicology. In this study bioassay-guided fractionation, ultra high performance liquid chromatography combined with time-of-flight mass spectrometry (UHPLC/TOFMS) and accurate mass database searching was tested to detect and identify unknown androgens. Herbal mixtures and sport supplements were tested using an androgen bioassay and modifications in sample preparations were carried out in order to activate inactive pro-androgens, androgen esters and conjugated androgens to enable their detection in the bioassay. Two of the four herbal mixtures tested positive and bioassay-guided fractionation followed by UHPLC/TOFMS of positive fractions resulted in the identification of nortestosterone phenylpropionate, testosterone cyclohexanecarboxylate and methyltestosterone. Three of the four sport supplements reacted toxic in the bioassay or gave inconclusive results and were further investigated using UHPLC/TOFMS in combination with data processing software and an accurate mass database having approximately 40,000 entries. This accurate mass database was derived from the PubChem database on the internet and coupled to the TOFMS software. This resulted in the tentative identification of several androgens, including methylboldenone, testosterone and the androgen esters methyltestosterone propionate or testosterone isobutyrate, testosterone buciclate and methylenetestosterone acetate. The study showed that bioassay-guided fractionation in combination with UHPLC/TOFMS analysis is a useful procedure to detect, isolate and identify unknown androgens in suspected samples. As an alternative, the use of data processing software in combination with an accurate mass database and coupled on-line with the TOFMS instrument software enabled the identification of androgens and androgen esters in the chromatogram even without bioassay-guided fractionation.  相似文献   

6.
The detection of the abuse of anabolic steroids in equine sport is complicated by the endogenous nature of some of the abused steroids, such as testosterone and nandrolone. These steroids are commonly administered as intramuscular injections of esterified forms of the steroid, which prolongs their effects and improves bioavailability over oral dosing. The successful detection of an intact anabolic steroid ester therefore provides unequivocal proof of an illegal administration, as esterified forms are not found endogenously. Detection of intact anabolic steroid esters is possible in plasma samples but not, to date, in the traditional doping control matrix of urine. The analysis of equine mane hair for the detection of anabolic steroid esters has the potential to greatly extend the time period over which detection of abuse can be monitored.  相似文献   

7.
Testosterone undecanoate (T‐C11) can be used by athletes in order to improve performance. After oral intake, T‐C11 is rapidly metabolized, hampering discrimination between exogenous and endogenous testosterone. A possible alternative is to detect the intact ester in hair. A method based on liquid chromatography–tandem mass spectrometry was developed for the determination of T‐C11 in hair. The sample procedure consisted of digestion of 200 mg of pulverized hair with tris(2‐carboxyethyl)phosphine hydrochloride and liquid–liquid extraction with n‐pentane. Several parameters such as the mobile phase, the ionization source and the washing step were optimized. The method was validated at different spiked levels obtaining satisfactory values for accuracy (between 92 and 102%) with relative standard deviations lower than 7% and a limit of detection of 0.2 ng/g. The applicability of the method was checked by the analysis of three samples from patients using T‐C11. A peak for the analyte was detected in all samples with concentrations between 0.4 and 8.4 ng/g. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionization (DESI) mass spectrometry (MS). In this work the feasibility of DESI application for the rapid screening of intact esters of anabolic steroids in bovine hair has been studied. Using a linear ion trap both full scan and data-dependent collision induced dissociation MS(n) spectra were acquired in minutes for testosterone cypionate, testosterone decanoate and estradiol benzoate standard solutions deposited on a glass or PTFE surface. However direct analysis of incurred hair failed due to inefficient desorption ionization and the minute quantities of steroid esters present. Therefore a simplified ultrasonic liquid extraction procedure was developed, allowing rapid DESI analysis of a few microliters of the concentrate and a total analysis time of 2-4h per batch instead of 3 days. The potential of this DESI approach is clearly demonstrated by MS(3) data from hair samples incurred with high levels (300-800 μg kg(-1)) of steroid esters, levels which do occur in samples from controlled- and illegally treated animals. For much lower levels state-of-the-art ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) screening methods remain the method of choice and might benefit from the proposed simplified extraction as well.  相似文献   

9.
An anti-ketamine molecularly imprinted polymer (MIP) was synthesized and used as the sorbent in a solid-phase extraction protocol to isolate ketamine and norketamine from human hair extracts prior to LC-MS/MS analysis. Under optimised conditions, the MIP was capable of selectively rebinding ketamine, a licensed anaesthetic that is widely misused as a recreational drug, with an apparent binding capacity of 0.13 μg ketamine per mg polymer. The limit of detection (LOD) and lower limit of quantification (LLOQ) for both ketamine and norketamine were 0.1 ng/mg hair and 0.2 ng/mg hair, respectively, when 10 mg hair were analysed. The method was linear from 0.1 to 10 ng/mg hair, with correlation coefficients (R 2) of better than 0.99 for both ketamine and norketamine. Recoveries from hair samples spiked with ketamine and norketamine at a concentration of 50 ng/mg were 86% and 88%, respectively. The method showed good intra- and interday precisions (<5%) for both analytes. Minimal matrix effects were observed during the LC-MS/MS analysis of ketamine (ion suppression −6.8%) and norketamine (ion enhancement +0.2%). Results for forensic case samples demonstrated that the method successfully detected ketamine and norketamine concentrations in hair samples with analyte concentrations ranging from 0.2 to 5.7 ng/mg and from 0.1 to 1.2 ng/mg, respectively.  相似文献   

10.
Recently we constructed yeast cells that either express the human estrogen receptor α or the human androgen receptor in combination with a consensus ERE or ARE repeat in the promoter region of a green fluorescent protein (yEGFP) read-out system. These bioassays were proven to be highly specific for their cognate agonistic compounds. In this study the value of these yeast bioassays was assessed for analysis of compounds with antagonistic properties. Several pure antagonists, selective estrogen receptor modulators (SERMs) and plant-derived compounds were tested. The pure antiestrogens ICI 182,780 and RU 58668 were also classified as pure ER antagonists in the yeast estrogen bioassay and the pure antiandrogen flutamide was also a pure AR antagonist in the yeast androgen bioassay. The plant-derived compounds flavone and guggulsterone displayed both antiestrogenic and antiandrogenic activities, while 3,3′-diindolylmethane (DIM) and equol combined an estrogenic mode of action with an antiandrogenic activity. Indol-3-carbinol (I3C) only showed an antiandrogenic activity. Coumestrol, genistein, naringenin and 8-prenylnaringenin were estrogenic and acted additively, while the plant sterols failed to show any effect. Although hormonally inactive, in vitro and in vivo metabolism of the aforementioned plant sterols may still lead to the formation of active metabolites in other test systems.  相似文献   

11.
Hair analysis has become a powerful tool for the detection of chronic and past drug consumption. For several years, it has been possible to determine even the intake of ethanol in hair samples by detecting the ethanol metabolites ethyl glucuronide or fatty acid ethyl esters. Recently, new requirements were published for the use of EtG as an abstinence test (c EtG < 7 pg/mg) as well as for heavy-drinking detection (c EtG > 30 pg/mg). In order to perform abstinence tests, a sensitive LC-MS/MS procedure has been developed and fully validated according to the guidelines of forensic toxicology. The nine-point calibration curve showed linearity over the range of concentrations from 2–1,000 pg/mg. Detection and quantification limits were 1 and 4 pg/mg respectively. The intra- and inter-day precision and accuracy were always better than 20%. The validated procedure has successfully been applied to perform abstinence tests and to analyze hair samples from persons in withdrawal treatment. Concentrations between <LOQ and 400 pg/mg were determined. In some cases, interfering peaks complicated the quantification to some extent. First results using varied chromatographic conditions showed constituting results. However, modified chromatographic conditions help substantiate critical results, especially if the determined EtG concentration is close to a cut-off value.  相似文献   

12.
The urinary steroid profile is constituted by anabolic androgenic steroids, including testosterone and its relatives, that are extensively metabolized into phase II sulfated or glucuronidated steroids. The use of liquid chromatography coupled to mass spectrometry (LC-MS) is an issue for the direct analysis of conjugated steroids, which can be used as urinary markers of exogenous steroid administration in doping analysis, without hydrolysis of the conjugated moiety. In this study, a sensitive and selective ultra high-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometer (UHPLC-QTOF-MS) method was developed to quantify major urinary metabolites simultaneously after testosterone intake. The sample preparation of the urine (1 mL) was performed by solid-phase extraction on Oasis HLB sorbent using a 96-well plate format. The conjugated steroids were analyzed by UHPLC-QTOF-MSE with a single-gradient elution of 36 min (including re-equilibration time) in the negative electrospray ionization mode. MSE analysis involved parallel alternating acquisitions of both low- and high-collision energy functions. The method was validated and applied to samples collected from a clinical study performed with a group of healthy human volunteers who had taken testosterone, which were compared with samples from a placebo group. Quantitative results were also compared to GC-MS and LC-MS/MS measurements, and the correlations between data were found appropriate. The acquisition of full mass spectra over the entire mass range with QTOF mass analyzers gives promise of the opportunity to extend the steroid profile to a higher number of conjugated steroids.  相似文献   

13.
Doping control of anabolic substances is normally carried out with urine samples taken from athletes and horses. Investigation of alternative specimens, e.g. hair samples, is restricted to special cases, but can also be worthwhile, in addition to urine analysis. Moreover, hair material is preferred in cases of limited availability or complicated collection of urine samples, e.g. from horses. In this work, possible ways of interpretation of analytical results in hair samples are discussed and illustrated by practical experiences. The results demonstrate the applicability of hair analysis to detect anabolic steroids and also to obtain further information about previous abuse. Moreover, the process of incorporation of steroids into hairs is described and the consequences on interpretation are discussed, e.g. on the retrospective estimation of the application date. The chosen examples deal with the detection of the anabolic agent testosterone propionate. Hair samples of an application study, as well as a control sample taken from a racing horse, were referred to. Hair material was investigated by a screening procedure including testosterone, nandrolone and several esters (testosterone propionate, phenylpropionate, decanoate, undecanoate, cypionate; nandrolone decanoate, dodecanoate and phenylpropionate; limits of detection (LODs) between 0.1 and 5.0 pg/mg). Confirmation of testosterone propionate (LOD 0.1 pg/mg) was carried out by an optimised sample preparation. Trimethylsilyl (TMS) and tert-butyl dimethylsilyl derivatives were detected by gas chromatography-high-resolution mass spectrometry (GC-HRMS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).  相似文献   

14.
Benzylpiperazine (BZP) is an amphetamine-type stimulant, which was legally available in New Zealand and widely used in “Party Pills” until reclassification as a Class C drug in April 2008. BZP was included as part of a multi-analyte method developed for hair screening using high-performance liquid chromatography triple quadrupole mass spectrometry (LC-MS/MS). A 20-mg sample of hair is extracted and partially purified using mixed-mode solid-phase extraction cartridges prior to analysis by LC-MS/MS. The method was developed as a broad screen for drugs of abuse (including amphetamines, opiates, and benzodiazepines), with only the BZP results being presented here. The assay was validated and found to be linear over the range of 0.085 to 8.65 ng/mg with correlation coefficient of r 2 ≥ 0.99. Blank hair samples spiked with BZP at 0.22 and 2.16 ng/mg gave intra- and inter-day precision coefficients of variation of ≤10% (n = 6 per day, 3 days) at both levels and calculated extraction efficiencies of 78% and 91%, respectively. The results from the samples submitted to the laboratory for BZP analysis showed 11% were positive (n = 126). The mean BZP level was 3.9 ng/mg (range, 0.4–33 ng/mg; the result was extrapolated when above the calibration). These data are the first available showing the levels expected from users of BZP.  相似文献   

15.
Measurement of steroid esters in bovine hair samples, using sensitive liquid chromatography-tandem mass spectrometry (LC–MS/MS), provides a powerful tool for identifying animals treated illicitly with growth promoters. The successful application of such testing requires appropriate sampling of hair from treated animals. This paper describes the results of hair analysis by LC–MS/MS for two animal studies in which animals were treated with estradiol-3-benzoate and nortestosterone decanoate. The results from the first animal study indicate that animals treated with these anabolic steroids may not always be identified from analysis of hair samples; positive test results occur sporadically and only for some of the treated animals. The results from the second animal study identify conditions attaching to positive hair samples, such as, that concentrations of steroid esters in hair are related to distance of sampling from point of injection and to time post-treatment, that concentrations of steroid esters in hair are related to dose given to the animal but that this relationship may vary over time post-treatment, and that steroid esters may be measured in regrowth hair taken some weeks after treatment. Steroid esters are determined along the length of the hair, confirming that accumulation of steroid esters into hair occurs from various sources, including blood, sweat and sebum. The reported research provides some useful insights into the mechanisms governing the persistence of steroid esters in bovine hair following illicit treatment with growth promoters.  相似文献   

16.
Owing to the tight control of methamphetamine, it is presumed that phentermine, an amphetamine-type anorectic, has recently been considered a supplement for methamphetamine abusers in Korea. In addition, the abuse of other anorectics obtained by inappropriate means has become a social issue. Hair is a useful specimen to prove chronic drug use. Therefore, an analytical method for the simultaneous detection of phentermine, phendimetrazine, amfepramone, fenfluramine, mazindol, methamphetamine, and 3,4-methylenedioxymethamphetamine (MDMA), as well as their metabolites, which covers the major amphetamines and anorectic agents in Korea, in hair was established and validated using liquid chromatography–tandem mass spectrometry (LC-MS/MS). The drugs and their metabolites in hair were extracted using 1 % HCl in methanol and then filtered and analyzed by LC-MS/MS with electrospray ionization in positive mode. The validation results for selectivity, linearity, matrix effect, recovery, process efficiency, intra- and interassay precision and accuracy, and processed sample stability were satisfactory. The limits of detection ranged from 0.025 to 1 ng/10 mg hair and the limits of quantification were 0.25 ng/10 mg hair for every analyte except mazindol and phentermine, for which they were 10 ng/10 mg hair. The method was successfully applied for the segmental determination of selected anorectics, methamphetamine, MDMA, and their metabolites in hair from 39 drug suspects. Among the anorectics, phentermine and/or phendimetrazine were identified with or without methamphetamine in the hair samples. Closer supervision of the inappropriate use of anorectics is necessary. Also, hair analysis is useful for monitoring the abuse potential of unnoticed drugs.  相似文献   

17.
 This study concerns the detection of natural steroid hormones in hair of cattle. Estradiol (E2) and testosterone (T) were chosen as representatives of estrogens and androgens. In particular, the influence of age, sex and hair pigmentation on the steroid concentrations was investigated. Samples were obtained from numerous steers, cows, bulls, and female and male calves. The extraction procedure for E2 and T from hair comprised liquid-liquid and solid-phase extraction and was followed by an essential high-performance liquid chromatography (HPLC) step for further purification of the extracts. Final quantification was performed with specific enzyme immunoassays (EIA). Lower E2-concentrations were detected in the hair of some steers, cows, and bulls (approximately 1 ng/g), in several of these hair samples the concentrations of E2 were below the limit of detection. Testosterone was measured in the hair of steers (approximately 3 ng/g), cows (approximately 6 ng/g), and bulls (in average 15 ng/g). There was a significant difference in the testosterone concentrations of white (approximately 8 ng/g) and of black hair (approximately 33 ng/g) of bulls. In hair from all male and female calves, E2 and T were measured. The concentrations amounted approximately to 9 ng E2/g and 3 ng T/g for female calves and to 5 ng E2/g and 7 ng T/g for male calves. There was no significant influence of sex or hair colour on the steroid concentrations in hair of calves. The results suggest that the method is a powerful means to detect natural steroid hormones in hair of animal origin. Received: 2 August 1996/Revised: 30 August 1996/Accepted: 5 September 1996  相似文献   

18.
 This study concerns the detection of natural steroid hormones in hair of cattle. Estradiol (E2) and testosterone (T) were chosen as representatives of estrogens and androgens. In particular, the influence of age, sex and hair pigmentation on the steroid concentrations was investigated. Samples were obtained from numerous steers, cows, bulls, and female and male calves. The extraction procedure for E2 and T from hair comprised liquid-liquid and solid-phase extraction and was followed by an essential high-performance liquid chromatography (HPLC) step for further purification of the extracts. Final quantification was performed with specific enzyme immunoassays (EIA). Lower E2-concentrations were detected in the hair of some steers, cows, and bulls (approximately 1 ng/g), in several of these hair samples the concentrations of E2 were below the limit of detection. Testosterone was measured in the hair of steers (approximately 3 ng/g), cows (approximately 6 ng/g), and bulls (in average 15 ng/g). There was a significant difference in the testosterone concentrations of white (approximately 8 ng/g) and of black hair (approximately 33 ng/g) of bulls. In hair from all male and female calves, E2 and T were measured. The concentrations amounted approximately to 9 ng E2/g and 3 ng T/g for female calves and to 5 ng E2/g and 7 ng T/g for male calves. There was no significant influence of sex or hair colour on the steroid concentrations in hair of calves. The results suggest that the method is a powerful means to detect natural steroid hormones in hair of animal origin. Received: 2 August 1996/Revised: 30 August 1996/Accepted: 5 September 1996  相似文献   

19.
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF) and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500 and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective sample preparation is expected to aggravate this issue further.  相似文献   

20.
This study reports the development and validation of a method using hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC-MS/MS) for the analysis of cocaine and its metabolites benzoylecgonine (BE), ecgonine methyl ester (EME), and cocaethylene (CE) in hair samples. Decontamination was performed as follows: Firstly, the aliquot of hair was briefly rinsed with 2 mL dichloromethane, then was washed three times with 10 mL 0.01 M phosphate buffer, pH 6, for 15 min, followed by 2 mL 2-propanol for less than 2 min, and, finally, a last rinse with 2 mL dichloromethane was again done. Cocaine compounds were extracted from 10 mg of hair by incubation with 2 mL 0.1 M HCl at 50 °C for 12 h and purified by solid phase extraction with Oasis MCX cartridges. Analysis was performed by LC-MS/MS using an Atlantis HILIC silica chromatographic column. The method was fully validated. Linearity was established over the concentration range 0.020–10.0 ng/mg for cocaine (COC), 0.010–10.0 ng/mg for BE and CE, and 0.005–2.0 ng/mg for EME, and the correlation coefficients were all >0.99. Extraction efficiency was >70% for all analytes. Limits of detection were 0.0005 ng/mg for CE and 0.001 ng/mg for the other analytes (COC, BE, and EME). Lower limits of quantification were the lowest points of the calibration curves with acceptable accuracy and precision (coefficient of variation ≤20%). Intra- and inter-day imprecision ranged between 1.5% and 9.5% and 0.7% and 12.6%, respectively. Intra- and inter-day inaccuracy ranged from 0.5% to 12.3% and from 0.7% to 7.1%, respectively. With regard to matrix effects, suppression was <27.5% in all cases. The method was applied to the analysis of several samples derived from forensic cases.  相似文献   