首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquid chromatographic (LC) type trace enrichment is coupled online with capillary gas chromatography (GC) with mass spectrometric (MS) detection for the analysis of aqueous samples. A volume of 1–10 ml of an aqueous sample is preconcentrated on a trace-enrichment column packed with a polymeric stationary phase. After cleanup with HPLC-grade water the precolumn is dried with nitrogen and subsequently desorbed with ethyl acetate. A fraction of 60 μl is introduced on-line into a diphenyltetramethyldisilazane-deactivated retention gap under partially concurrent solvent evaporation conditions and using an early solvent vapor exit. The analytes are separated and detected by means of GC–MS. The potential of the LC–GC–MS system for monitoring organic pollutants in river and drinking water is studied. Target analysis is carried out with atrazine and simazine as model compounds; the detection limits achieved under full-scan and multiple ion detection conditions are 30 pg and 5 pg, respectively. Identification of unknown compounds (non-target analysis), is demonstrated using a river water sample spiked with 168 pollutants varying in polarity and volatility.  相似文献   

2.
It has recently been shown that the use of strong organic solvents as diluent is possible in RPLC, provided that the solvent used as diluent is retained more strongly by the column than the analytes in the sample. In this study, the phenomenon was further studied experimentally using several water-immiscible solvents (ethyl acetate, isopropyl acetate, and methyl isobutyl ketone) and several model analyte compounds. In all cases, analyte peak distortion was minimal provided the analyte eluted earlier than the diluting solvent, in contrast to substantial broadening and distortion when the analyte eluted after the diluting solvent. The potential analytical utility of this approach is discussed, and an example of a practical application is also presented.  相似文献   

3.
Summary A fast and simple procedure for the analysis of aqueous samples by on-line membrane disk extraction and capillary gas chromatography (GC) is presented. As an example, organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.2 mm diameter extraction disks. The layers are dried by a stream of nitrogen (10–15 min; ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapour exit. The final analysis is carried out by GC with thermionic detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from two European rivers. With a sample volume of only 2.5 ml, detection limits of 10–30 ppt are achieved in tap water and of 50–100 ppt in river water.  相似文献   

4.
The feasibility of using ethyl acetate for the desorption of trace pollutants from a liquid chromatographic precolumn on-line into a diphenyltetramethyldisilazane-deactivated retention gap and, subsequently analysis by means of capillary gas chromatography has been demonstrated. First 5% of methanol are added to the water sample to prevent sorption of analytes onto parts of the preconcentration system. About 1 ml of this aqueous sample is injected onto a precolumn containing a polymeric stationary phase, using water–methanol (95:5, v/v) for transport and clean-up. The precolumn is desorbed with ethyl acetate and a fraction of 75 μl is injected on-line into the retention gap; separation is then achieved on a capillary CP Sil 19 column. No breakthrough of the test compounds was observed in the preconcentration step. The recovery was quantitative and the response obtained with flame ionization detection was linear in the range 0.1–100 ng/ml. The effect of varying the sorption flow rate on the recovery was studied. The system was applied to the analysis of river water.  相似文献   

5.
An orthogonal two-dimensional liquid chromatographic (2D-LC) system was developed by using a vacuum-evaporation loop-type valve interface. Normal-phase liquid chromatography (NPLC) with a bonded CN phase column was used as the first dimension, and reversed-phase liquid chromatography (RPLC) with a C(18) column was used as the second dimension. All the solvents in the loop of the interface were evaporated at 90 degrees C under vacuum conditions, leaving the analytes on the inner wall of the loop. The mobile phase of the second dimension dissolved the analytes in the loop and injected them onto the secondary column, allowing an on-line solvent exchange of a selected fraction from the first dimension to the second dimension. The chromatographic resolution of analytes on the two dimensions was maintained at their optimal condition. Sample loss due to evaporation in the interface was observed that depended on the boiling point of the compound. Separation of sixteen polycyclic aromatic hydrocarbon mixtures and a traditional Chinese medicine Angelica dahurica was demonstrated.  相似文献   

6.
Abstract

Trace amounts (ppb or less) of phosphorus containing compounds present in aqueous samples are adsorbed on XAD-4 and subsequently eluted by means of ethyl acetate. The solvent and the eluted compounds are evaporated and swept over a Tenax-GC tube. This gas stripping method traps the phosphorus containing compounds together with only a small amount of the solvent whereas the water entrapped in the XAD step is removed simultaneously. The compounds are desorbed from the Tenax-GC tube and injected into the gas chromatograph using the combination of thermal desorption, cold trapping and flash heating. The subsequent analysis is carried out on a capillary column and the compounds are detected by means of a flame photometric detector. The various steps of the analytical procedure are discussed, including the recoveries of the different compounds studied and some instrumental aspects.  相似文献   

7.
A preparative high‐speed countercurrent chromatography method was successfully used for the isolation of five minor flavones from Polygonum cuspidatum flowers. Among them, three compounds were obtained from P. cuspidatum for the first time. A twin two‐phase solvent system composed of n‐hexane/ethyl acetate/ethanol/water (1:6:3:6, v/v/v/v) and petroleum ether/ethyl acetate/methanol/water (2:4:3:3, v/v/v/v) was developed. Compounds were obtained from the fraction B and fraction C prepurified by silica gel column chromatography. Five minor compositions, 6.8 mg of hesperidin, 11.2 mg of phloridzin, 4.9 mg of luteolin, 5.3 mg of hyperin, and 3.7 mg of luteoloside were obtained from 140 mg of the fraction B and 110 mg of fraction C with a purity of 95.3, 96.4, 98.0, 96.8, and 95.3%, respectively, as determined by high‐performance liquid chromatography. The structures of these compounds were identified by 1H and 13C NMR spectroscopy.  相似文献   

8.
A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and grapes. For extraction, several solvents were evaluated with respect to the possibility of direct injection, matrix-induced suppression or enhancement of response, and extraction efficiency. Overall, ethyl acetate was the most favourable solvent for extraction, although a solvent switch was required. For some pesticide/matrix combinations, reconstitution of the residue after evaporation required special attention. Extracts were analysed on a C18 column with polar endcapping. The pesticides were ionised using atmospheric pressure chemical ionisation on a tandem mass spectrometer in multiple reaction monitoring mode. The final method is straightforward and involves extraction with ethyl acetate and a solvent switch to 0.1% acetic acid/water without further cleanup. The method was validated at the 0.01 and 0.5 mg/kg level, for both cabbage and grapes. Recoveries were between 80 and 101% with R.S.D. < 11% (n = 5). The limit of quantification was 0.01 mg/kg and limits of detection were between 0.001 and 0.004 mg/kg.  相似文献   

9.
In the present study the retaining precolumn, which is commonly used in a set-up for large-volume on-column injections, or when solid-phase extraction (SPE) or liquid chromatography is coupled to gas chromatography (CC), was removed after varying its length from the standard length of 3 m down to zero. A dramatic increase of the evaporation rate of the injected organic solvent was obtained from a typical value of 100 microl/min up to 300 microl/min. The increased evaporation rate allowed (i) injection of a larger volume in the same retention gap, (ii) faster injection/transfer of the organic solvent and (iii) reduction of the transfer temperature. As volatile compounds under partially concurrent solvent evaporation conditions are easily lost once the organic solvent has been removed via a solvent-vapour exit (SVE), the parameters for large-volume injection, i.e. the evaporation rate and injection speed, were optimised using accurate measurements of the real flow-rate of the carrier gas into the GC system. All these options have been evaluated over the last 4 years. In order to demonstrate that omitting the retaining precolumn had no effect on the application range of the on-column interface, analytes as volatile as benzene were injected into GC-MS using 50-200 microl of n-pentane solutions. Contaminants were extracted from river water and wastewater into n-pentane using in-vial liquid-liquid extraction. The detection limits for benzene, toluene, ethylbenzene and m-xylene were approximately 10 ng/l. To obtain optimum results the SVE had to be closed 1 s before the end of evaporation. Several brands of n-pentane were analysed to check for the presence of benzene. Most of them contained interfering compounds and benzene at the low microg/l level and therefore had to be cleaned by means of column chromatography. As another example C8-C17 alkylphenones were extracted from wastewater with n-hexane. Detection limits were 10-40 ng/l.  相似文献   

10.
The separation of polar compounds is challenging work due to poor retention and insufficient selectivity. In the present study, an efficient strategy for large-scale preparation of five polar polyphenols including three isomers from Phyllanthus emblica Linn has been established by preparative high-speed counter-current chromatography. Macroporous resin column chromatography was used for the enrichment of the polar polyphenols. However, sugar and other ultra-polar impurities were co-washed out with the targets. Liquid-liquid extraction with ethyl acetate/water (1/1, v/v) solvent system was developed to remove the ultra-polar impurities with a clearance rate of 95%. Finally, the targets were introduced to preparative high-speed counter-current chromatography for separation using ethyl acetate/n-butanol/acetic acid/water (2/7/1/10, v/v/v/v) solvent system. As a result, 191 mg of Mucic acid 1,4-lactone 5-O-gallate, 370 mg of β-Glucogallin, 301 mg of Gallic acid, 195 mg of Mucic acid 1,4-lactone 3-O-gallate and 176 mg of Mucic acid 1,4-lactone 2-O-gallate with purity higher than 98% were obtained from 1.5 g of sample. Mucic acid 1,4-lactone 3-O-gallate, Mucic acid 1,4-lactone 3-O-gallate, and Mucic acid 1,4-lactone 2-O-gallate are isomers. The results showed that high-speed counter-current chromatography could be well developed for the separation of polar compounds from natural products.  相似文献   

11.
10‐Deacetylbaccatin III, an important semisynthetic precursor of paclitaxel and docetaxel, can be extracted from Taxus wallichiana Zucc. A process for the isolation and purification of 10‐deacetylbaccatin III ( 1 ), baccatin III ( 2 ), and 7β‐xylosyl‐10‐deacetyltaxol ( 3 ) from the leaves and branches of Taxus wallichiana Zucc. via macroporous resin column chromatography combined with high‐speed countercurrent chromatography or reversed‐phase flash chromatography was developed in this study. After fractionation by macroporous resin column chromatography, 80% methanol fraction was selected based on high‐performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis. A solvent system composed of n‐hexane, ethyl acetate, methanol, and water (1.6:2.5:1.6:2.5, v/v/v/v) was used for the high‐speed countercurrent chromatography separation at a flow rate of 2.5 mL/min. The reversed‐phase flash chromatography separation was performed using methanol/water as the mobile phase at a flow rate of 3 mL/min. The high‐speed countercurrent chromatography separation produced compounds 1 (10.2 mg, 94.4%), 2 (2.1 mg, 98.0%), and 3 (4.6 mg, 98.8%) from 100 mg of sample within 110 min, while the reversed‐phase flash chromatography separation purified compounds 1 (9.8 mg, 95.6%) and 3 (4.9 mg, 97.9%) from 100 mg of sample within 120 min.  相似文献   

12.
The potential of immunoaffinity-based solid-phase extraction (IASPE) coupled on-line to gas chromatography (GC) for the determination of micropollutants was studied with emphasis on the interfacing of the immunoaffinity-based SPE and GC parts of the system. The cartridge containing the immobilized antibodies was coupled to the gas chromatograph via a reversed-phase cartridge (copolymer sorbent). After trace enrichment of the analytes on the immunoaffinity cartridge, they were desorbed and recollected on the reversed-phase cartridge by means of an acidic buffer. After clean-up and drying with nitrogen, desorption and transfer to the GC was done with ethyl acetate via an on-column interface in the partially concurrent solvent evaporation mode. The antibodies used in the immunoaffinity cartridge were raised against atrazine; several s-triazines were used as test compounds. Triazines that were structurally similar to atrazine, showed quantitative recovery. As an application, immunoaffinity SPE–GC was used for the analysis of river and waste water and orange juice. The selectivity of the system was such that non-selective flame ionization detection (FID) could be used to detect the analytes of interest in these complex matrices. The detection limits for 10-ml water samples were 15–25 ng/l for FID and about 1.5 ng/l for the nitrogen–phosphorus detection.  相似文献   

13.
The design of a new interface to hyphen high efficiency supercritical fluid chromatography (SFC) and fast RPLC in a comprehensive configuration is described. SFC x RPLC is a viable alternative to normal phase (NP) LC x RPLC and is characterized by high orthogonality. Compared to NPLC x RPLC an additional advantage is the expansion of supercritical carbon dioxide (CO(2)) when exposed to atmospheric pressure leading to fractions consisting of solvents that are miscible with the second dimension RPLC mobile phase. The interface consists of a two-position/ten-port switching valve equipped with two packed octadecyl silica (C(18)) loops for effective trapping and focusing of the analytes after elution from the SFC dimension. The addition of a water make-up flow to the SFC effluent prior to entering the loops is of fundamental importance to efficiently focus the solutes on the C(18) material and to reduce interferences of expanded CO(2) gas on the second dimension separation. The features of the system are illustrated with the analysis of a lemon oil sample.  相似文献   

14.
Retention prediction models for reversed-phase liquid chromatography (RPLC) have been extensively studied owing to the fact that RPLC remains the most widely used chromatographic technique especially in the field of pharmaceutical and biomedical analyses. However, RPLC is not always the method of choice for the analysis of some compounds that have high polarity. Hydrophilic interaction chromatography (HILIC) has been gaining interest in the last few years as an alternative option to RPLC for the analysis of polar and hydrophilic analytes. HILIC is a variant of normal-phase liquid chromatography, but utilizes water in a water-miscible organic solvent as the eluent in conjunction with a hydrophilic stationary phase. The present review aims to summarize recent contributions on the development of retention prediction models for a group of basic analytes, namely, the adrenoreceptor agonists and antagonists, on different polar stationary phases. The use of multiple linear regression and artificial neural networks in model building is highlighted.  相似文献   

15.
In this paper, we report an efficient method by high‐speed counter‐current chromatography for the first separation of four aromatic acids and two analogs with similar structures and polarities from Clematis akebioides. First, the ethyl acetate extract was treated by silica gel column chromatography to enrich the target compounds. And then the fraction with target compounds were purified by high‐speed counter‐counter chromatography using a two‐phase solvent system consisting of chloroform/acetonitrile/water (10:6:4, v/v). The results showed high‐speed counter‐current chromatography could be a powerful technology for the separation of compounds with similar structures and polarities. Besides, it was found acetonitrile could be a good methanol substitute when a chloroform/methanol/water system could not provide a good separation factor. This study provides a reference for the separation of compounds from Clematis akebioides.  相似文献   

16.
Solvent-assisted supercritical fluid extraction is superior to Soxhlet extraction, solvent extraction at reflux, and simultaneous setam distillation solvent extraction for the isolation of semivolatile compounds from the cinnamons of commerce. Optimized extraction conditions are described using carbon dioxide at 300 atm and 70°C to extract 0.5 g of powdered cinnamon mixed with 4.5 g of anhydrous sodium sulfate to which 1.0 ml of acetonitrile was added at the start of the sequential 30 min static and 30 min dynamic extraction. The semivolatile compounds were collected by solvent trapping in ethyl acetate and analyzed directly by series coupled-column gas chromatography after filtration and partial solvent evaporation. Twenty-one compounds identified by mass spectrometry were quantified in twenty-four samples of cinnamon and cassia purchased in Sri Lanka, Korea, United Kingdom, and the United States of America. True cinnamon is easily distinguished from cassia by the presence of eugenol, absence of δ-cadinene, much lower amounts of coumarin, and larger amounts of benzyl benzoate. Principal component analysis using the relative composition of the twelve major semivolatile compounds provides a clear distinction between true cinnamon and cassia as well as useful interspecies differences which can be used for further classification.  相似文献   

17.
Counter‐current chromatography is a chromatographic technique with a support‐free liquid stationary phase. In the present study, a successful application of linear gradient counter‐current chromatographic method for preparative isolation of bioactive components from the crude ethanol extract of Zanthoxylum planispinum was presented. The application of n‐hexane/ethyl acetate/methanol/water quaternary solvents, in terms of “HEMWat” or “Arizona” solvent families, in gradient elution mode was evaluated. Results indicated that slightly proportional changes of biphasic liquid systems provided the possibility of gradient elution in counter‐current chromatography, maintaining stationary phase retention in the column. With the selected quaternary solvent systems composed of n‐hexane/ethyl acetate/methanol/water (2:1:2:1 and 3:2:3:2, v/v), and optimized gradient programs, in total seven fractions were separated in 4.5 h. Most of the purified compounds could be obtained at the milligram level with over 80% purity. The present study indicated that the linear gradient counter‐current chromatographic approach possessed unique advantages in terms of separation efficiency, exhibiting great potential for the comprehensive separation of complex natural extracts.  相似文献   

18.
Quantification of neurotransmitters as biologically active analytes in neurological samples is of high interest for studying their effect on multiple targets. This work is part of a strategy involving two-dimensional liquid chromatography (2D LC) system with mass spectrometry (MS) detection. The concept of the on-line LC system is the coupling of reversed phase liquid chromatography (RPLC, the second separation dimension) to ion-exchange chromatography (IEC, the first dimension). Our objective in this study is to find the appropriate second dimension column, ensuring that samples of neurotransmitters are refocused and separated on it. Silica-based columns designed specifically to retain polar compounds were tested in LC conditions and compared with results obtained with a porous graphitic carbon (PGC, Hypercarb) column. These polar embedded, polar endcapped, and high-density alkyl chain columns successfully separated analytes in question using mobile phase systems with high percentage of water, or even pure water. Only Hypercarb column provided efficient retention of the most polar neurotransmitters and could be used for trapping and preconcentrating the compounds without rapid breakthrough.  相似文献   

19.
For the first time, rare major and minor compounds from fruits of Peucedanum cervaria were isolated. High‐performance countercurrent chromatography with two different solvent systems, heptane/ethyl acetate/methanol/water (3:2:3:2 and 2:1:2:1, v/v), was successfully used in the reversed‐phase mode. A scale‐up process from analytical to semipreparative in a very short time was developed. The structures of isolated compounds were evaluated by high‐performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry, gas chromatography with mass spectrometry, and one‐ and two‐dimensional NMR spectroscopy. (8S,9R)‐9‐(3‐Methylbutenoyloxy)‐O‐acetyl‐8,9‐dihydrooroselol (compound B), (8S,9R)‐9‐(2‐methyl‐Z‐butenoyloxy)‐O‐acetyl‐8,9‐dihydrooroselol (edultin, compound C), and (8S,9R)‐9‐acetoxy‐O‐(2α‐methylbutyryl)‐8,9‐dihydrooroselol (compound D) were obtained using heptane/ethyl acetate/methanol/water (2:1:2:1, v/v) in <40 min. The method yielded 4.6 mg of a mixture of compounds B and C (11:89) and 3.7 mg of compound D. These amounts were obtained from the crude extract (0.5 g) in a single run. Although the compounds are known, their isolation by countercurrent chromatography and the analysis of their relative stereochemistry by two‐dimensional NMR spectroscopy have been performed for the first time. Additionally, heptane/ethyl acetate/methanol/water (3:2:3:2, v/v) led to the isolation of oxypeucedanin (1.2 mg; compound A). This is the first time that angular dihydrofuranocoumarin was isolated from plant extract by countercurrent chromatography.  相似文献   

20.
Stilbenoids are the main components of leaves and stems of Pholidota chinensis. In the present investigation, high‐speed counter‐current chromatography was used for the separation and purification of two classes of stilbenoids, namely, bibenzyls and 9,10‐dihydrophenanthrenes, on a preparative scale from whole plants of P. chinensis with different solvent systems after silica gel column chromatography fractionation. n‐Hexane/ethyl acetate/methanol/water (1.2:1:1:0.8, v/v/v/v) was selected as the optimum solvent system to purify 1‐(3,4,5‐trimethoxyphenyl)‐1′,2′‐ethanediol ( 1 ), coelonin ( 2 ), 3,4′‐dihydroxy‐5,5′‐dimethoxybibenzyl ( 3 ), and 2,?7‐?dihydroxy‐?3,?4,?6‐?trimethoxy‐?9,?10‐?dihydrophenanthrene ( 4 ). While 2,7‐dihydroxy‐3,4,6‐trimethoxy‐?9,?10‐?dihydrophenanthrene ( 5 ), batatasin III ( 6 ), orchinol ( 7 ), and 3′‐O‐methylbatatasin III ( 8 ) were purified by n‐hexane/ethyl acetate/methanol/water (1.6:0.8:1.2:0.4, v/v/v/v). After the high‐speed counter‐current chromatography isolation procedure, the purity of all compounds was over 94% assayed by ultra high performance liquid chromatography. The chemical structure identification of all compounds was carried out by mass spectrometry and 1H and 13C NMR spectroscopy. To the best of our knowledge, the current investigation is the first study for the separation and purification of bibenzyls and 9,10‐dihydrophenanthrenes by high‐speed counter‐current chromatography from natural resources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号