首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
To thoroughly explore the aerodynamic noise in order to achieve a more efficient engineering application for a vehicle intake system, the large eddy simulation and the finite element method were employed in numerical simulations, and the aeroacoustic characteristics were validated through the experimental data. In this research, the k-ε model was adopted to simulate the steady state fluid dynamic, and the static pressure loss was consistent with the bench test data, indicating the computational fluid dynamics model was valid. After acquiring the data from the steady state simulation, the fluctuating pressure of the inner wall was calculated based on the transient state calculation results from the large eddy simulation. Thereafter, the finite element method was used to determine the acoustic performance of the intake system. By comparing the experiment data, the noise reduction indicated that the intake system performed well at various frequencies, e.g. 320 Hz, 520 Hz and 770 Hz, but poorly at 140 Hz, 210 Hz, 420 Hz and 600 Hz. Finally, the far-field aerodynamic noise was calculated based on FW-H equation, and the output showed that the noise of each measuring point agreed well with the test results in trend. In particular, the inlet sound pressure spectrum almost fit the test data with the airflow of 300 m3/h, and several amplitude peaks appeared at 210 Hz, 420 Hz and 600 Hz, corresponding to the low-attenuation region of the noise reduction curve. Moreover, the specific frequencies were not shifted with the airflow changing. In conclusion, the numerical simulation method proves to be effective in calculating the aerodynamic noise accurately.  相似文献   

2.
In this paper, we have proposed a new algorithm considering commutation error and feedback effect to enhance the convergence rate and noise reduction efficiency of ANC controller. In order to improve noise reduction performance of the ANC headset with fixed-point DSP, we have proposed a new FxLMS algorithm, FxLMS CF, which considers the commutation error and feedback. Also, using a non-real-time simulation, we have decided the phase and amplitude compensation factors of anti-noise signal considering round-off and quantization error, nonlinear distortion and delay of analog device. We estimated the phase and amplitude compensation factors by simulation without using any special measuring devices or analysis devices, and reduced the broadband noise by 24 dB.  相似文献   

3.
Investigations into active noise control (ANC) technique have been conducted with the aim of effective control of the low-frequency noise. In practice, however, the performance of currently available ANC systems degrades due to the effects of nonlinearity in the primary and secondary paths, primary noise and louder speaker. This paper proposes a hybrid control structure of nonlinear ANC system to control the non-stationary noise produced by the rotating machinery on the nonlinear primary path. A fast version of ensemble empirical mode decomposition is used to decompose the non-stationary primary noise into intrinsic mode functions, which are expanded using the second-order Chebyshev nonlinear filter and then individually controlled. The convergence of the nonlinear ANC system is also discussed. Simulation results demonstrate that proposed method outperforms the FSLMS and VFXLMS algorithms with respect to noise reduction and convergence rate.  相似文献   

4.
Active noise control has been applied to a variety of systems in order to improve performance without the increases in size and weight that would otherwise be required by traditional passive noise control treatments. This paper investigates the application of an active noise control system to the control of generator noise in the master cabin of a luxury yacht. A multichannel, multi-tonal active noise control system employing loudspeakers and microphones in the master cabin of the yacht is investigated. It is shown that, due to the high number of engine orders produced by the generator, in order to achieve significantly perceptible levels of noise attenuation it is necessary to control at least 7 individual orders. A controller is investigated which targets 19 engine orders and it is shown to achieve in excess of 5 dB broadband attenuation, whilst achieving up to 23 dB attenuation in individual orders. This corresponds to a 23% reduction in the Zwicker loudness.  相似文献   

5.
In order to control low frequency noise in exhaust pipe, this paper puts forward a new concept of H-Q tube based semi-active muffler device. The semi-active muffler device and bench testing system have been designed and operated. Finite element simulation study on semi-active muffler and experimental study on semi-active muffler and passive muffler have been carried on. The effect of simulation and experiment are consistent. The semi-active muffler device acts well in low frequency band, especially between 50 Hz and 150 Hz. The average level of noise reduction is around 35 dB, which is much better than passive muffler. Between 150 Hz and 350 Hz, semi-active muffler has a better performance than passive muffler; above 350 Hz, it has worse performance compared with the passive muffler.  相似文献   

6.
I.IntroductionThereverberantnoisesmaybereducedwithanactivenoisecontrol(ANC)systcmformedbyacornermicrophonc-amplifier-1oudspcakersystemina.oom.lllThismeth-odbascdonthenormalmodccancelingprincip1chasalreadybeenclarifiedbothinthco-ryandexperimcnts,andthclimitationandpotcntialityofitsapp1icationalsodiscussedinapreviouspaper.Thediscussionsinthepastlimitedmost1ytothesteadyconditionofnoiscfield,andthisisextendedtothetransientcondihoninthcprcsentwork,viz.thein-llucnceofthecornerANCsystemwhenthenois…  相似文献   

7.
An optoelectronic feedback loop intended to suppress intensity noise of a light field is introduced in this paper. A maximum intensity noise reduction of 10 dB is experimentally achieved between frequency of 0?140 kHz on a 1064 nm DPSS continuous wave single-frequency solid-state laser. After optimization and miniaturization, this system is expected to be widely used as a simple ?Noise-Eater?.  相似文献   

8.
Y. Simard  R. Lepage 《Applied Acoustics》2010,71(11):1093-1098
The impact of shipping noise on marine life and quality of marine mammal habitats in oceans and coastal environments has become a major concern worldwide. Background noise can also limits detection of marine mammal sounds in passive acoustic monitoring (PAM) systems. Characterisation of this noise over long time periods and estimates of the exposure of the different marine mammal groups are still very fragmentary and limited to only a few locations. This paper presents such observations for a part of a busy seaway of North America, the St. Lawrence Seaway, which cuts through the Gulf of St. Lawrence and crosses several cetaceans and pinnipeds feeding areas. Noise was continuously recorded for a 5-month period in summer 2005 by an AURAL autonomous hydrophone deployed close to the bottom in the 300-m deep seaway. The maximum received noise level in the 20 Hz-0.9 kHz band reached 136 dB re 1 μParms. The median level of 112 dB re 1 μParms was exceeded 50% of the time due to transiting merchant ships. Median spectral level tracks the reference curve for heavy traffic in oceans and 50% of the noise is within a ±6 dB envelope around it. Strong spectral lines were common at low frequencies and in the 400-800 Hz band. M-weighting functions applied for the three groups of cetaceans and pinnipeds indicate wideband median levels varying from 106 to 112 dB-M re 1 μParms surrounded by a ±5 dB two-quartile interval. Higher values are expected for animals frequenting the sound channel at intermediate depths. As expected, the highest M-weighting levels correspond to low-frequency specialists and pinnipeds. Criteria for assessing the behavioural and physiological impacts of long term exposure of marine mammals to such shipping noise levels need to be worked out.  相似文献   

9.
This paper presents the design and performance of an open jet, blow down wind tunnel that was newly commissioned in the anechoic chamber at the ISVR, University of Southampton, UK. This wind tunnel is intended for the measurement of airfoil trailing edge self-noise but can be extended to other aeroacoustic applications. With the primary objectives of achieving acoustically quiet and low turbulence air jet up to 120 m/s through a 0.15 m × 0.45 m nozzle, several novel noise and flow control techniques were implemented in the design. Both the acoustical and aerodynamic performances of the open jet wind tunnel were examined in detail after its fabrication. It is found that the background noise of the facility is adequately low for a wide range of exit jet velocity. The potential core of the free jet is characterized by a low turbulence level of about 0.1%. Benchmark tests by submerging a NACA0012 airfoil with tripped and untripped boundary layers at 0° and 10° angles of attack respectively into the potential core of the free jet were carried out. It was confirmed that the radiating airfoil trailing edge self-noise has levels significantly above the rig noise over a wide range of frequencies. The low noise and low turbulence characteristics of this open jet wind tunnel are comparable to the best facilities in the world, and for its size it is believed to be the first of its kind in the UK.  相似文献   

10.
This work reports on investigations into the wind dependence of ambient noise in the Bay of Bengal. Ambient noise measurements were made in the shallow water of Bay of Bengal using a portable broadband, high frequency data acquisition system together with a sensitive hydrophone suspended from the measuring platform at a depth of 5 m from the surface where the ocean depth was 25 m. Periodic measurements were carried out for one year corresponding to a wind speed range between 2 m/s and 9 m/s during summer, monsoon and winter seasons. The proportionality of the noise level with wind speed for frequencies ranging from 500 Hz to 6 kHz for each season was studied. The analysis reveals that the correlation between the wind speed and the ambient noise spectrum level was higher at lower frequencies. The results of empirical fitting based on analysis were used for noise level prediction and the model predictions compare well with the measured noise level. Further it was observed that the wind generated noise level measured during summer was approximately 8 dB less than that in other seasons. On the other hand the proportionality between the noise level and the wind speed was less during winter.  相似文献   

11.
Functional magnetic resonance imaging (fMRI) provides a noninvasive tool for observing correlates of neural activity in the brain while a subject listens to sound. However, intense acoustic noise is generated in the process of capturing MR images. This noise stimulates the auditory nervous system, limiting the dynamic range available for displaying stimulus-driven activity. The noise is potentially damaging to hearing and is distracting for the subject. In an active noise control (ANC) system, a reference sample of a noise is processed to form a sound which adds destructively with the noise at the listener's ear. We describe an implementation of ANC in the electromagnetically hostile and physically compact MRI scanning environment. First, a prototype system was evaluated psychoacoustically in the laboratory, using the electrical drive to a noise-generating loudspeaker as the reference. This system produced 10-20 dB of subjective noise-reduction between 250 Hz and 1 kHz, and smaller amounts at higher frequencies. The system was modified to operate in a real MR scanner where the reference was obtained by recording the acoustic scanner noise. Objective reduction by 30-40 dB of the most intense component in scanner noises was realized between 500 Hz and 3500 Hz, and subjective reduction of 12 dB and 5 dB in tests at frequencies of 600 Hz and at 1.9 kHz, respectively. Although the benefit of ANC is limited by transmission paths to the cochlea other than air-conduction routes from the auditory meatus, ANC achieves worthwhile attenuation even in the frequency range of maximum bone conduction (1.5-2 kHz). ANC should, therefore, be generally useful during auditory fMRI.  相似文献   

12.
The purpose of this study is to explore the effects of sound elimination in a cylindrical duct by combining a reactive muffler and active noise control (ANC) system. Besides the exploration via experiment of the combined noise control system, a Grey prediction based on Grey theory is also applied to ANC for this hybrid system.In the experiment for this system, a combined adaptive algorithm is adopted. The results of sound elimination are compared between cases with ANC systems installed before the muffler and after the muffler. The results indicate that the sequence of arrangement of muffler can influence the results of active noise control. According to the results of experiment and simulation, the effect of noise reduction in ANC system is influenced extremely by reference signal received. The transmission loss and insertion loss in this system are also discussed in details. Besides, the experimental results indicate that the hybrid system has the advantages over a traditional muffler when the muffler is not designed for the frequency of the noise. Furthermore, the mathematic simulation for acoustic field in a cylindrical duct with a muffler is performed in order to verify the experiment results. Finally, Grey theory is applied to estimate the expected signals in order to perform a computer simulation of Grey prediction to explore effects of the ANC system. The results indicate that application of Grey theory gives a good control for the hybrid system.  相似文献   

13.
Vertical Greenery Systems (VGS) are promising contemporary Green Infrastructure which contribute to the provision of several ecosystem services both at building and urban scales. Among others, the building acoustic insulation and the urban noise reduction could be considered. Traditionally vegetation has been used to acoustically insulate urban areas, especially from the traffic noise. Now, with the introduction of vegetation in buildings, through the VGS, it is necessary to provide experimental data on its operation as acoustic insulation tool in the built environment. In this study the acoustic insulation capacity of two VGS was conducted through in situ measurements according to the UNE-EN ISO 140-5 standard. From the results, it was observed that a thin layer of vegetation (20–30 cm) was able to provide an increase in the sound insulation of 1 dB for traffic noise (in both cases, Green Wall and Green Facade), and an insulation increase between 2 dB (Green Wall) and 3 dB (Green Facade) for a pink noise. In addition to the vegetation contribution to sound insulation, the influence of other factors such as the mass factor (thickness, density and composition of the substrate layer) and type of modular unit of cultivation, the impenetrability (sealing joints between modules) and structural insulation (support structure) must be taken into account for further studies.  相似文献   

14.
This paper presents an active bearing for reducing the radiated structure borne noise of rotating machinery. This modular bearing uses piezostacks to generate secondary forces in the vibration transmission path of the controlled structure. The bearing is tested on an experimental test bed comprising a rotating shaft, which is mounted in a frame. Noise is radiated by a plate that is attached to the frame. To evaluate different control approaches, a simplified model of the set-up was made. Based on the simulation results, a combination of feedback and repetitive control is implemented, using a force and acceleration measurement. This way, a noise reduction of more than 10 dB is achieved at the most important resonance frequencies of the system below 1 kHz.  相似文献   

15.
This paper proposes an active partition that can be placed between a snorer and a non-snorer on a bed to reduce the snoring noise around the non-snorer ears by integrating a rigid finite size passive partition with a two channel active noise control system. The noise reduction performance of the passive partition on a bed with a headboard is studied first, where the effects of the height and the width of the partition are discussed. Due to the limited partition size, the attenuation for the low-frequency diffracted noise is not sufficient, so two loudspeakers are proposed to be installed on the partition as the secondary sources to increase the overall noise attenuation. Both numerical simulations and experiments are carried out to demonstrate the feasibility of the proposed integrated snoring noise control system, and the results show that the proposed active partition can achieve over 10 dB noise attenuation at non-snorer ears in the 1/3 octave bands from 80 to 1000 Hz.  相似文献   

16.
A promising means to reduce the component of railway rolling noise radiated by the track is to increase the damping of the rail. This increases the attenuation with distance of vibrations transmitted along the rail and thereby reduces the noise radiated. To achieve this, a tuned, damped mass-spring absorber system has been designed. To cover a wide range of frequencies, multiple tuning frequencies are used along with a material with a high damping loss factor. Suitable materials have been found from extensive tests on samples and prototypes of the damper have been built and tested, both in the laboratory and in the field. Results are very promising with reductions of the track component of noise of around 6 dB being measured.  相似文献   

17.
The purpose of this study is to present a statistical model which can predict the noise level of road-traffic in urban area. A spatial statistical model which can take into account spatial dependency on geographically neighboring areas is constructed from a noise map of a city in South Korea. A system of 250 m × 250 m grid cells is placed on the city of Cheongju, South Korea, and the noise level and urban form indicators are averaged over each cell. The population-weighted mean of the noise level is subsequently regressed on the average urban form by adopting the spatial autoregressive model (SAR) and the spatial error model (SEM), as well as an ordinary least squares (OLS) model. Direct and indirect impacts are analyzed for a valid interpretation of the spatial statistical models. Factors such as GSI, FSI, traffic volume, traffic speed, road area density, and the fraction of industrial area turn out to have significant impacts on the noise level.  相似文献   

18.
A new honeycomb core design has been used to increase the stiffness of the panel and applied to improve the noise transmission loss at frequencies between 100 and 200 Hz. A model is presented to predict the transmission loss of the honeycomb panels based on the structural modal parameters. A new test specimen with fiber reinforced plastic cores and face sheets had been used to investigate the effect of stiffness and damping on noise transmission loss. The measurements of noise transmission loss have been compared with data for common structural panels. The results show that the new core fabrication techniques using moulding to improve the noise transmission are effective. In comparison to a cement panel of the same mass, the honeycomb panels have higher TL at low frequencies between 100 and 200 Hz due to higher stiffness and damping. The honeycomb panels have more significant vibration responses above 500 Hz but these are limited by damping.  相似文献   

19.
Access to quiet areas in cities is important to avoid adverse health effects due to road traffic noise. Most urban areas which are or can become quiet (LA,eq < 45 dB) are shielded from direct road traffic noise. By transfer paths over roof level, many road traffic noise sources contribute to the level in these shielded areas and noise abatement schemes may be necessary to make these areas quiet. Two real life shielded courtyards in Göteborg have been selected as reference cases for a numerical investigation of noise abatement schemes. The selected areas are modelled as canyons with a road traffic noise source modelled outside the canyon by a finite incoherent line source, which is more realistic than both a coherent and an incoherent line source of infinite length. The equivalent sources method has been used for the calculations. For all studied noise abatement schemes in the shielded canyon, the reductions are largest for the lower canyon observer positions. Façade absorption is the most effective when placed in the upper part of the canyon and can typically yield a reduction of 4 dB(A). Constructing 1 m wide walkways with ceiling absorption reduces the level typically by 3 dB(A). These effects are most effective for narrower canyons. For treatments at the canyon roof, reductions are independent of the canyon observer position and amount to 4 dB(A) for a 1 m tall screen and 2 dB(A) for a grass covering of a saddle roof. Downward refracting conditions increase the levels for the lower canyon observer positions and higher frequencies. For sources located in canyons, abatement schemes therein are more effective for noise reduction in the shielded canyon than similar abatement schemes in the shielded canyon itself, given that all contributing source canyons are treated.  相似文献   

20.
Pass-by noise from high-speed trains is one important area that has to be handled in all new train projects. For the new line between Oslo and the Gardemoen Airport which opened in 1998, very stringent requirements were set out regarding external noise. To reach the target it was decided that the train should be equipped with wheel dampers. Two different types of wheel dampers were used on the train; a ring damper was mounted on the wheels of the driven bogies, whilst plate dampers divided into tuned absorber fins were mounted on the wheels of the trailer bogies.During the type testing of the Airport Express Train, additional measurements were performed in order to evaluate the acoustic effect of the plate wheel dampers. Two test series were performed with the same train set; first with the train in standard configuration and secondly with the wheel dampers removed from the second and third bogie. The external noise was measured at 5 and 25 m distance from the centre of the track at speeds ranging from 80 to 200 km/h. The third-octave filtered time histories were analyzed to calculate the effect of the wheel dampers. As expected, there was a significant reduction of 4-6 dB at frequencies above 2000 Hz, but there was also a reduction of 2 dB for frequencies as low as 800 Hz. This reduction was also found in the parts of the time histories when the rail should be dominating. This implies that the wheel dampers also reduce the rail noise. The total rolling noise reduction for the trailer bogie was 3 dB at 200 km/h and 1 dB at 80 km/h. From comparison with TWINS-calculated sound power levels it was estimated that the wheel noise would be reduced by 5 dB and the rail noise would be reduced by 1 dB at 200 km/h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏