首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micrometers and 200 keV/micrometers. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.  相似文献   

2.
Four experiments utilizing passive detectors (P0006, P0004, A0015, M0004) were flown on LDEF to study the radiation environment. These experiments have been summarized in a companion paper (Benton et al., 1996). One of the experimental goals was to measure LET spectra at different locations and shielding depths with plastic nuclear track detectors (PNTD). It was found that the LET spectra extended well above the LET cutoff imposed by the geomagnetic field on GCR particle penetration into LEO. The high LET particles detected were mostly short-range (range < 2000 μm), indicating that they were secondaries produced locally within the PNTD. The presence of these high LET particle fluences is important for the determination of dose equivalent because of the high Quality Factors (Q) involved. A relatively small fraction of particle fluence can contribute a large fraction of dose equivalent.

Short-range, inelastic secondary particles produced by trapped protons in the South Atlantic Anomaly (SAA) were found to be a major contributor to the LET spectra above 100 keV/μm. The LET spectra were found to extend beyond the 137 keV/μm relativistic GCR Fe peak to over 1000 keV/μm. The high LET tail of the LET spectra was measured in CR-39 and polycarbonate PNTDs using different techniques. GCR made a relatively modest contribution to the LET spectra as compared to the contributions from short-range secondary particles and stopping protons.

LET spectra intercomparisons were made between LDEF measurements and exposures to 154 MeV accelerated proton beams. The similarities support the role of nuclear interactions by trapped protons as the major source of secondary particles in the PNTDs. Also techniques were employed to reduce the range cutoff for detection of the short-range secondaries to 1 μm, so that essentially all secondary particles were included in the LET spectra. This has allowed a more realistic assessment of secondary contribution to dose equivalent.

Comparisons of measured and calculated LET spectra have been made that demonstrate the need for more accurate modeling of secondary particles in radiation transport codes. Comparisons include preliminary calculations in which attempts have been made to include secondary particles.  相似文献   


3.
Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent.  相似文献   

4.
Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called “Real-time Radiation Monitoring Device (RRMD)” utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 μSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5°) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15–200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.  相似文献   

5.
The dosimetry telescope (DOSTEL) was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 microGy/d and 121 +/- 13 microGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event.  相似文献   

6.
TLD efficiency of 7LiF for doses deposited by high-LET particles.   总被引:2,自引:0,他引:2  
The efficiency of 7 LiF TLDs (TLD-700) in registering dose from high-LET (> or = 10 keV/micrometers) charged particles (relative to 137Cs gamma rays) has been measured for a number of accelerated heavy ions at various particle accelerator facilities. These measured efficiency values have been compared with similar results obtained from the open literature and a dose efficiency function has been fitted to the combined data set. While it was found that the dose efficiency is not only a function of LET, but also of the charge of the incident particle, the fitted function can be used to correct the undermeasured value of dose from exposures made in mixed radiation fields where LET information is available. This LET-dependent dose efficiency function is used in our laboratory in determining total absorbed dose and dose equivalent from combined TLD and CR-39 plastic nuclear track detector measurements.  相似文献   

7.
Radiation measurement on the International Space Station   总被引:1,自引:0,他引:1  
The results of an investigation of radiation environment on board the ISS with apogee/perigee of 420/380 km and inclination 51.6 degrees are presented. For measurement of important characteristics of cosmic rays (particles fluxes, LET spectrum, equivalent doses and heavy ions with Z > or = 2) a nuclear photographic emulsion as a controllable threshold detector was used. The use of this detector permits a registration of the LET spectrum of charged particles within wide range of dE/dx and during the last years it has already been successfully used on board the MIR station, Space Shuttles and "Kosmos" spacecrafts. An integral LET spectrum was measured in the range 0.5-2.2 x 10(3) keV/micrometers and the value of equivalent dose 360 microSv/day was estimated. The flux of biologically dangerous heavy particles with Z > or = 2 was measured (3.85 x 10(3) particles/cm2).  相似文献   

8.
The spectrometer of linear energy transfer (LET) was developed. It is based on the chemically etched polyallyldiglycolcarbonate (PADC) track-etch detector. LET spectra are estimated through track parameter determination and analysed by an automatic optical image analyser LUCIA G. Three PADC materials were used: 0.5 mm thick Page, 0.5 and 1 mm thick Tastrak; they were exposed to protons with energies up to 1000 MeV. Such energetic protons are generally not directly registrable in any of PADCs mentioned; the tracks observed correspond mostly to secondary particles created through nuclear interactions of primary protons. LET spectra permit to calculate the dose absorbed in the detector due to these secondary particles and to compare it with the ionization collision dose of primary protons. It is observed that the dose due to secondary particles represents a few percent of the ionization collision dose. Their ratio varies slightly with proton energy, and some differences between the three PADCs used were also observed. The importance of results obtained for on-board spacecraft dosimetry is analysed and discussed.  相似文献   

9.
The LET distributions during the Space Shuttle missions STS-84 (altitude 270-412 km, average 375 km; inclination angle, 51.6 degrees) and STS-91 (altitude 328-397 km, average 373 km; inclination angle, 51.6 degrees) were measured using CR-39 plastic nuclear track detectors. A correction for the dip-angle dependence of the track-formation sensitivity of the CR-39 plates was applied to the data analysis. The absorbed doses and the dose equivalents around RRMD Detector Units, estimated from the LET distributions in the LET region of 4-200 keV/micrometers, fluctuated with standard deviations of +/- 21% to +/- 35% in both flight experiments. The LET distributions obtained from the CR-39 plates agreed well with that obtained from RRMD-II in STS-91. However, the particle fluxes obtained from RRMD-III in STS-84 and STS-91 were two or three times higher than those obtained from RRMD-II and the CR-39 plates. It was concluded that the LET distributions obtained from RRMD-II and the CR-39 plates in the present flight experiments did not include the contribution of target-fragmented secondary heavy particles produced by low-LET particles, such as relativistic or semi-relativistic protons and helium ions, whereas RRMD-III was able to detect these secondary particles because of its low triggering level.  相似文献   

10.
Human will be sooner or later return to the moon and will eventually travel to the planets near Earth. Space radiation hazards are an important concern for human space flight in deep space where galactic cosmic rays (GCR) and solar energetic particles are dominated and radiation is much stronger than that in LEO (Low Earth Orbit) because in deep space there is no magnetosphere to screen charged particle and no big planet nearby to shadow the spacecraft.Research indicates that the impact of particle radiation on humans depends strongly on the particles' linear energy transfer (LET) and the radiation risk is dominated by high LET radiation. Therefore, radiation research on high LET should be emphasized and conducted systematically so as to make radiation risk as low as reasonably achievable (ALARA) for astronauts.Radiation around the moon can be measured with silicon detectors and/or CR-39 plastic nuclear track detectors (PNTDs). At present stage the silicon detectors are one of the preferred active dosimeters which are sensitive to all LET and CR-39 detectors are the preferred passive dosimeters which are sensitive to high LET (≥5 keV/μm water). CR-39 PNTDs can be used as personal dosimeters for astronauts. Both the LET spectrum and the charge spectrum for charged particles in space can be measured with silicon detectors and CR-39 detectors.Calibrations for a detector system combined with the silicon detectors CRaTER (Cosmic Rays Telescope for the Effects of Radiation) from Boston University and Massachusetts Institute of Technology, and the CR-39 PNTDs from JSC (Johnson Space Center) – SRAG (Space Radiation Analysis Group) were conducted by exposing the detector system to the accelerator generated protons and heavy ions. US space mission for the radiation measurement around the moon using CRaTER was carried out in 2009.Results obtained from the calibration exposures indicate an excellent agreement between LET spectrum and charge spectrum measured with CR-39 detectors and simulated with PHITS (Particle and Heavy Ion Transport System).This paper introduces the LET spectrum method and charge spectrum method using CR-39 PNTDs and the Monte Carlo simulation method for CR-39 detectors, presents and compares the results measured with CR-39 PNTDs and simulated for CR-39 detectors exposed to heavy irons (600 MeV/n) in BNL (Brookhaven National Laboratory) in front and behind the CRaTER.  相似文献   

11.
The average absorbed dose and dose equivalent rates from space radiation were observed using passive dosimeters with same material and configuration at the same location onboard the International Space Station (ISS) over four different occasions (I–IV) between 2007 and 2008. The passive dosimeters consisted of a combination of thermoluminescent detectors (TLDs) and plastic nuclear track detectors (PNTDs). Total average absorbed dose rate increased by 68 ± 9% over two years. The observed increase was due to the incremental increase in the altitude of the ISS over the course of the experiment and the corresponding increase in trapped proton flux encountered during passage of the ISS through the SAA (South Atlantic Anomaly), which was confirmed with the results monitored by DB-8 active dosimeter on the ISS. The PNTD data showed that the average absorbed dose and dose equivalent rates from particles of LETH2O ≥ 100 keV/μm were 28 ± 2% and 51 ± 3% of ≥10 keV/μm during Periods I–III, while the dose contributions of particles ≥100 keV/μm during Period IV were 36 ± 5% and 59 ± 10%, respectively. The integral dose equivalent distribution during Period IV shows significant enhancement from particles ≥100 keV/μm. These facts suggest that a significant fraction of the high LET component is due to short-range recoil nuclei produced in target fragmentation reactions between primary protons and the nuclei of the passive dosimeters and surrounding materials.  相似文献   

12.
High- and intermediate-energy protons are not able to directly form a track in a CR-39 etch detector (TED). Such detectors, however, can be used for the detection and dosimetry of the beams of these particles through the registration of secondary charged particles with sufficiently high values of linear energy transfer (LET). High-energy protons (72–220 MeV) and Intermediate-energy protons (10–30 MeV) with low LET values ranging from 1.1 down to 0.4 keV/μm and 5.87 down to 2.40 keV/μm, respectively are considered in this study. It seems to be sufficient to create secondary particles, although the LET values are low. This phenomenon can modify the characteristics of the energy transfer process due to these particles, which should be taken into account when such particles are used for radiobiology studies or for radiotherapy. The importance of these secondary particles was investigated experimentally by means of an LET spectrometer based on a chemically etched track detector in which the tracks of the primary protons are not revealed. Experiments were performed with proton beams available at the Nuclear Research Center for Agriculture and Medicine (NRCAM) in Karaj, Iran and at the National Cancer Center (NCC) in Seoul, Korea with protons of primary energies of about 10–30 MeV and 72–220 MeV respectively. The contribution of the secondary particle dose increases as the proton energy decreases. The origin of the secondary particles in interactions with protons having high and intermediate energies due to various nuclear reactions was calculated by the both ALICE and TALYS computer codes. The secondary microdosimetry doses were also calculated by GEANT4 code. There is large discrepancy between experimental and calculated results in low proton energies. It has been verified that there is a good correlation between the experimentally obtained results and the reaction cross sections predicted by ALICE and TALYS codes.  相似文献   

13.
This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope.  相似文献   

14.
A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.  相似文献   

15.
Thermoluminescent detectors (TLDs) are widely used for the dosimetry of photons and electrons. They are less used for the radiation with higher linear energy transfer (LET). One of the reasons for that is that their TL relative efficiency η decreases for the most of them with increasing LET.

The paper presents first a review of author's experimental results in which η was established for charged particles having LET of the order from 1 to 100 keV/μm in tissue. Among TLDs studied were known materials like LiF:Mn; Ti; Al–P glass; CaSO4:Dy; Al2O3:Na; and Al2O3:C. It was found that the dependence of their η on LET is not the same for all TLDs studied.

The response of the same materials to neutrons was also studied. It was found that both η as the relative response (RR) defined in terms of absorbed dose in tissue are different, they depend critically also on the composition. When a TLD contains nuclei like 6Li and 10B, their RR would be rather high. As far as η is concerned, the same tendencies were observed as for charged particles, i.e. when average LET of secondary particles formed in a TLD increases, their η generally decreases.  相似文献   


16.
We compare models of radiation transport and biological response to physical and biological dosimetry results from astronauts on the Mir space station. Transport models are shown to be in good agreement with physical measurements and indicate that the ratio of equivalent dose from the Galactic Cosmic Rays (GCR) to protons is about 3/2:1 and that this ratio will increase for exposures to internal organs. Two biological response models are used to compare to the Mir biodosimetry for chromosome aberration in lymphocyte cells; a track-structure model and the linear-quadratic model with linear energy transfer (LET) dependent weighting coefficients. These models are fit to in vitro data for aberration formation in human lymphocytes by photons and charged particles. Both models are found to be in reasonable agreement with data for aberrations in lymphocytes of Mir crew members: however there are differences between the use of LET dependent weighting factors and track structure models for assigning radiation quality factors. The major difference in the models is the increased effectiveness predicted by the track model for low charge and energy ions with LET near 10 keV/micrometers. The results of our calculations indicate that aluminum shielding, although providing important mitigation of the effects of trapped radiation, provides no protective effect from the galactic cosmic rays (GCR) in low-earth orbit (LEO) using either equivalent dose or the number of chromosome aberrations as a measure until about 100 g/cm 2 of material is used.  相似文献   

17.
Samples of polyallyldiglycolcarbonate (PADC) track etch detectors (TED) were exposed to high energy 12C nuclei at the particle beam of the Dubna synchrophasotron. The energy of 12C nuclei varied between 0.1 and 1.5 GeV per amu.

At the low studied energies the linear energy transfer (LET) of these nuclei is higher than the detector threshold value. Then, the primary particle tracks are directly etched in the detector surface. The detection efficiency approaches to 100% at perpendicular incidence. Their LET has been established by means of standard authomatized procedure recently developed. The LET values found here are in good agreement with theoretical ones.

At 1.5 GeV per amu (LET 8.4 KeV μm−1) the secondary particle tracks were evaluated in all the exposed detectors. The energy deposited by these particles was compared to the energy deposited through primary ionization losses. It was found out that its contribution to the total dose is relatively lower than for protons of comparable energies. In some of these samples even the tracks of the primary nuclei were observed. It follows that the detection threshold of the developed LET spectrometer should be below 10 keV μm−1.  相似文献   


18.
《Radiation measurements》2001,34(1-6):193-197
A spectrometer of the linear energy transfer (LET) based on the chemically etched polyallyldiglycolcarbonate (PADC) track etched detector was developed. The LET spectra are determined through the measurements of track parameters, it covers LET range between 10 and 700 keV/μm in tissue. A combined experimental and theoretical approach allowed the estimation of the critical dimensions of the sensitive volume necessary for developing a track to several nm. It seemed interesting to us to compare the LET spectra obtained by this method with the microdosimetric spectra available on the basis of a classical experimental microdosimetry method, a tissue equivalent proportional counter, for which the critical dimensions simulated are of the order of a few μm.

Both methods of experimental microdosimetry were compared in the high energy radiation reference fields and on the subsonic aircraft board. It was found out that the microdosimetric distributions are similar; some differences are, nevertheless, observed. Further studies with the goal to explain them are outlined.  相似文献   


19.
There are only a few methods of dosimetry which can estimate the contribution of different particles to onboard spacecraft and/or aircraft exposure. This contribution describes an attempt to estimate the contribution of different components to the exposure level using MDU-Liulin energy deposition spectrometer and thermoluminescent detectors (TLD’s), in combination with a spectrometer of linear energy transfer (LET) based on track etch detectors. This equipment was exposed onboard: the International Space Station for a long period and two shorter shuttle missions and a commercial subsonic aircraft for several long-term monitoring periods from 2001 to 2006. The data obtained are analyzed from several points of view and the obtained results are presented, analyzed, and discussed. The text was submitted by the authors in English.  相似文献   

20.
We present calculations of linear energy transfer (LET) spectra in low earth orbit from galactic cosmic rays and trapped protons using the HZETRN/BRYNTRN computer code. The emphasis of our calculations is on the analysis of the effects of secondary nuclei produced through target fragmentation in the spacecraft shield or detectors. Recent improvements in the HZETRN/BRYNTRN radiation transport computer code are described. Calculations show that at large values of LET (> 100 keV/μm) the LET spectra seen in free space and low earth orbit (LEO) are dominated by target fragments and not the primary nuclei. Although the evaluation of microdosimetric spectra is not considered here, calculations of LET spectra support that the large lineal energy (y) events are dominated by the target fragments. Finally, we discuss the situation for interplanetary exposures to galactic cosmic rays and show that current radiation transport codes predict that in the region of high LET values the LET spectra at significant shield depths (> 10 g/cm2 of Al) is greatly modified by target fragments. These results suggest that studies of track structure and biological response of space radiation should place emphasis on short tracks of medium charge fragments produced in the human body by high energy protons and neutrons.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号