首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 214 毫秒
1.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

2.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

3.
A high-performance liquid chromatographic assay for determination of cefonicid concentrations in human plasma and urine samples has been developed using cefazolin as an internal standard. For the analysis of plasma samples two calibration curves were utilized covering the cefonicid concentration ranges of 0.05-1.0 microgram/ml and 1.0-50.0 micrograms/ml, respectively. Coefficients of variation of 7.4% or less were obtained for cefonicid concentrations of 0.05-50.0 micrograms/ml. Mean bias was +6.0% at 0.05 micrograms/ml cefonicid and between -2.1% and +1.6% for 1.0-50.0 micrograms/ml cefonicid. Plasma samples containing 30 ng/ml cefonicid could be well distinguished from blank plasma samples. Urine samples were analysed by using a calibration curve for cefonicid concentrations between 1.0 and 50.0 micrograms/ml. ranged from 8.6% at a cefonicid concentration of 1.0 microgram/ml to 0.5% at 50.0 micrograms/ml with a mean bias between -3.0% and +0.3%.  相似文献   

4.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

5.
A simple, rapid and sensitive method for the determination of iothalamic acid (IA) in both plasma and urine is reported. After extraction with ethyl acetate, IA was determined by strong anion-exchange high-performance liquid chromatography with ultraviolet detection at 254 nm. The lower limit of detection was 0.5 micrograms/ml. The average recovery was 73 and 57% from plasma and urine, respectively. Linearity was found over the investigated concentration range (up to 500 micrograms/ml for plasma and up to 10.0 mg/ml for urine). The reproducibility of the technique was good (coefficient of variation less than 6%) as was the precision and accuracy (coefficient of variation less than 2.5%). No interference from endogenous substances or any of the common drugs tested was found.  相似文献   

6.
Determination of malotilate and its metabolites in plasma and urine   总被引:1,自引:0,他引:1  
A method for the determination of malotilate (I), the corresponding monocarboxylic acid (II) and its decarboxylated product (III) in plasma is described. Plasma was extracted with chloroform spiked with internal standard. The residue, dissolved in methanol, was chromatographed on a reversed-phase column with a mobile phase of 60% acetonitrile and 1% acetic acid in water. The sensitivity limit for I, II and III was 50, 25 and 100 ng/ml of plasma, respectively. Compound I in the same plasma extract was also analysed by gas chromatography--electron-impact mass spectrometry. The base peaks m/z 160 for I and m/z 162 for internal standard (IV) were monitored; the sensitivity limit for I was 2.5 ng/ml of plasma. The determination of the metabolites of I, II and its conjugate (V), and isopropyl-hydrogen malonate (VI) in urine by high-performance liquid chromatography is also described. The limit of quantification for VI was 2.0 micrograms/ml, and the overall coefficient of variation of VI was 4.7%. The limit of quantification for II in urine was 0.5 micrograms/ml and that for V was 1.0 micrograms/ml as total II (II + V). The overall precision of the method was satisfactory. The method was used to determine plasma and urine concentrations in four dogs orally dosed with 100, 200 or 400 mg of malotilate.  相似文献   

7.
A sensitive reversed-phase high-performance liquid chromatographic (HPLC) technique with ultraviolet detection has been developed to determine the concentration of BRB-I-28 (I), a novel antiarrhythmic agent, in dog plasma and urine. The mobile phase was acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8-triethylamine (50:50:75:0.1, v/v). The compound was extracted from dog plasma and urine with chloroform after alkalinization with sodium hydroxide. The extraction recovery was 83% from plasma and 84% from urine. Good linearity (r > 0.996) was observed throughout the ranges 0.1-12.0 micrograms/ml (plasma) and 0.1-8.0 micrograms/ml (urine). Intra- and inter-assay variabilities were less than 4%. The lower limit of quantitation was 0.08 microgram/ml in either plasma or urine. HPLC analysis of plasma and urine samples from a dog treated with I has demonstrated that the method was accurate and reproducible.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 micrograms/ml for plasma, 3 micrograms/ml for urine and 0.03 micrograms/ml for saliva using UV detection.  相似文献   

9.
A sensitive, selective and easy to use high-performance liquid chromatographic method for the determination of cicletanide, a new diuretic, in plasma, red blood cells, urine and saliva is described. After extraction of cicletanide together with an internal standard with diethyl ether, or diethyl ether-n-hexane (20:80) for urine, the sample extracts are chromatographed with water-methanol-acetic acid (50:50:0.3) as eluent on to a Nucleosil C18 column. Both compounds are detected by their ultraviolet absorption at 280 nm. The calibration graph was linear between 0.2 and 20 micrograms/ml for plasma and between 0.2 and 5 micrograms/ml for the other biological fluids. The sensitivity limit was 20 ng/ml for plasma, red blood cells and saliva and 30 ng/ml for urine. The coefficients of variation of the between-day assays did not exceed 4.6% in plasma, 8.3% in red blood cells, 7.8% in urine and 4.2% in saliva for the lowest concentrations studied. The application of the method to a pharmacokinetic study of cicletanide after a single oral therapeutic dose in humans is reported.  相似文献   

10.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new anticonvulsant, fluzinamide, and three of its active metabolites. This method requires only 0.5 ml of plasma, and it involves a single extraction with a mixture of hexane--dichloromethane--butanol (55:40:5). The plasma extract is chromatographed on a 10-micron, C18 reversed-phase column and quantitated by ultraviolet absorbance at 220 nm. The concentration--response curves for all four compounds are linear from 0.05 micrograms/ml to at least 10 micrograms/ml. The extraction efficiency of this method is greater than 90%. The accuracy and precision of the method were tested by analyzing spiked unknown samples that had been randomly distributed across the concentration range. The mean concentrations found were within +/- 9% of the various amounts added with a standard deviation of +/- 3.5%. This method has been successfully applied to the analysis of samples obtained from fluzinamide-dosed dogs, healthy unmedicated volunteers, and patients who were at steady state with phenytoin, carbamazepine, and fluzinamide.  相似文献   

11.
A rapid, sensitive and selective method was developed for the determination of a novel steroidal androgen receptor antagonist (Win 49596, I) in human plasma. The procedure involved extraction from plasma using a solid-phase phenyl support and elution directly onto a reversed-phase C8 column using a mobile phase consisting of 0.2 mol/l sodium acetate buffer at pH 7-acetonitrile (45:55, v/v). Drug was monitored by ultraviolet detection at a wavelength of 238 nm. Linear responses were observed for standards over the range 0.01-5.0 micrograms/ml. The minimum quantifiable level was 0.02 microgram/ml, using a 0.5-ml plasma sample. The precision was 5.5% and the accuracy ranged from -9.4% to 0.23%. The analytical method has been used to quantify I in plasma from dogs and rats and is projected for use with human plasma from clinical trials.  相似文献   

12.
A sensitive method for the simultaneous high-performance liquid chromatographic determination of clarithromycin and its active metabolite in plasma and urine is described. Alkalinized samples were coextracted with an internal standard and analyzed on a C8 column using electrochemical detection. Recoveries were greater than or equal to 85% and consistent. Standard curves for plasma were linear in the range 0-2 micrograms/ml for both compounds (r greater than 0.99), with limits of quantification of approximately 10.03 micrograms/ml (0.5-ml sample). Within-day and day-to-day precision were good, with coefficients of variation mostly within +/- 5%; accuracy for both compounds were routinely within 90-110% of theoretical values. Standard curves for urine were linear in the range 0-100 micrograms/ml with limits of quantification of 0.5 micrograms/ml (0.2-ml sample). Urine assays also had similar within-day and day-to-day precisions and accuracy.  相似文献   

13.
The use of a small precolumn instead of an injection loop for the determination of a new phytochemical drug, fellavine, and its metabolites is described. The method combines the direct injection of plasma and urine into the reversed-phase precolumn with separation on a Spheri-5 RP-18 analytical column. Different sorbents in the precolumn were compared. A recovery of fellavine and its metabolites from biological fluids except rat plasma of almost 100% was achieved on Chrompack RP (30-40 microns) and LiChrosorb RP-18 (7 microns). For rat plasma only the last sorbent gave 80% fellavine recovery. The influence of the protein binding on the fellavine recovery was examined. The limit of detection was equal to 0.05 micrograms/ml fellavine for plasma and 0.02 micrograms/ml for urine. To enhance the limit of detection longer precolumns were perferred.  相似文献   

14.
A sensitive gas chromatographic assay with electron-capture detection has been developed for sulfamic acid diester (sulfamic acid 1,7-heptanediyl ester, NSC 329680) based on its conversion to 1,7-diiodoheptane in the presence of excess sodium iodide. The assay is linear up to 1 microgram/ml sulfamic acid diester and has a lower limit of detection of 25 ng/ml from 0.5 ml plasma. The coefficient of variation of the assay is 6.4% at 1 microgram/ml and 8.0% at 100 ng/ml. Sulfamic acid diester is relatively stable in 0.9% sodium chloride and 0.1 M sodium phosphate buffers, pH 7.0-9.0, with half-lives greater than 38 h. The major breakdown product of sulfamic acid diester is sulfamic acid 1,7-heptane-monoyl ester. When added to whole blood sulfamic acid diester shows concentration-dependent breakdown. At 50 and 100 micrograms/ml sulfamic acid diester, the half-time in whole blood is 6.9 h and 65% of the drug is sequestered by the blood cells. At 10 micrograms/ml sulfamic acid diester in blood, there is no detectable breakdown of the drug over 24 h and all of the drug is sequestered by the blood cells. Protein binding of sulfamic acid diester in human plasma is 82% at 10 micrograms/ml and 68% at 100 micrograms/ml.  相似文献   

15.
A rapid, selective, precise reversed-phase liquid chromatographic method has been developed for the determination of a potential memory-enhancing agent (CL 275,838) and its main metabolite (CL 286,527) in plasma and serum. The procedure includes isolation of compounds from proteins precipitated with acetonitrile, subsequent resolution by reversed-phase (Whatman Partisphere C8) high-performance liquid chromatography and ultraviolet detection. The assay was linear over the range 0.12-1.25 micrograms/ml of plasma or serum. The detection limit was 0.12 micrograms/ml, using 0.2 ml of plasma or serum. Intra- and inter-day validation studies indicated an acceptable precision and reproducibility of the method within the concentration range investigated, the overall coefficient of variation being less than 10%. The method is currently applied in support of pharmacological and toxicity studies of the compound in rodents.  相似文献   

16.
The automated determination of amifloxacin and two of its principal metabolites in human plasma and urine by column-switching high-performance liquid chromatography is described. Plasma or urine samples, diluted 1:1 with 0.5 M sodium citrate buffer pH 2.5, were directly injected onto a cation-exchange pre-column. Following a 2.0-min wash of the pre-column with water at a flow-rate of 1.1 ml/min, the effluent from the pre-column was directed to the analytical column by a column-switching device. The precision of the plasma and urine methods ranged from a +/- 1.9 to +/- 3.6% for all compounds. The accuracies of the methods were within a range of -3.3% to 6.4% of the nominal values for all compounds. Linear responses were observed for all the standards in the range 0.10-5.0 micrograms/ml for plasma and 0.50-100 micrograms/ml for urine for all three compounds. The minimum quantifiable levels were 0.10 and 0.50 micrograms/ml for plasma and urine, respectively. The analytical methods may be used to quantify amifloxacin and the piperazinyl-N-desmethyl and piperazinyl-N-oxide metabolites in plasma and urine samples obtained from humans, monkeys, dogs and rats.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of neomycin in plasma and urine. The plasma was deproteinated with trichloroacetic acid and centrifuged. The supernatant was mixed with ion-pair concentrate and centrifuged again. The resultant supernatant was analyzed by HPLC. Urine was centrifuged to remove debris, if any, mixed with ion-pair concentrate and analyzed directly by HPLC. The HPLC conditions consisted of an ion-pairing mobile phase, a reversed-phase column, post-column derivatization with o-phthalaldehyde (OPA) reagent and fluorescence detection. The overall average recovery of neomycin was 97 and 113% from plasma spiked at 0.25-1.0 micrograms/ml, using standard curves prepared in plasma extract and in water, respectively, and 94% for urine spiked at 1-10 micrograms/ml using a standard curve prepared in water. The method was used to detect neomycin in plasma and urine obtained from animals injected intramuscularly with neomycin. Various pharmacokinetic parameters of neomycin were also determined from its profile of plasma concentration versus time.  相似文献   

18.
A method for the simultaneous determination of disopyramide and mono-N-desisopropyldisopyramide enantiomers extracted from human plasma and urine is presented. Separation and quantitation were carried out using two columns coupled in series, and UV detection at 254 nm. First, the racemates of the two compounds were separated using a reversed-phase column, and then the enantiomers were separated using a stereoselective column packed with human alpha 1-acid glycoprotein. The mobile phase was 8 mM phosphate buffer, pH 6.20-2-propanol (92:8, v/v). The coefficients of variation (%) for the plasma daily determination were 6.7% for R(-)- and S(+)-disopyramide at drug levels of 1.5 micrograms/ml, and 8.5% and 7.7% for R(-)- and S(+)-mono-N-desisopropyldisopyramide, respectively, at drug levels of 0.375 micrograms/ml. The method has allowed the study of stereoselective metabolism and pharmacokinetics of disopyramide after oral administration as a racemate.  相似文献   

19.
A rapid, sensitive and selective high-performance liquid chromatographic method for the determination of the neuroprotectant 6-nitro-7-sulphamoylbenzo[f]quinoxaline-2,3-dione in rat plasma has been established and validated. Samples of 0.5 ml of plasma are extracted by elution from a Bond-Elut column with methanol and analysed on a reversed-phase column. The wavelength of UV detection is 254 nm. The method is linear at least up to 30 micrograms/ml, with a lowest reliable determination level of 4 mg/ml. The assays has a coefficient of variation of 13% at 10 ng/ml and 4% at 1000 ng/ml. Small variations in the extraction procedure and the liquid chromatographic conditions have minimal or no influence on the assay.  相似文献   

20.
Two different reversed-phase high-performance liquid chromatographic methods for the determination of aniracetam (I) and its metabolite N-anisoyl-GABA (II) in human plasma are described. The procedure for I involves direct injection of plasma samples spiked with the internal standard on a clean-up column followed by reversed-phase chromatography on a C18 column. The limit of quantification was 5 ng/ml, using a 200-microliters specimen of plasma. The mean inter-assay precision of the method up to 800 ng/ml was 3%. The procedure for II involved liquid-liquid extraction of II and the internal standard from plasma with ethyl acetate, and reversed-phase chromatography on a C18 column. The limit of quantification was 50 ng/ml using a 0.5-ml plasma specimen. The mean inter-assay precision up to 50 micrograms/ml was 6%. The applicability and accuracy of the methods were demonstrated by the analysis of over 1000 plasma samples from two bioavailability studies in healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号