首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper, the important issue of the desorption of less- and nonvolatile compounds with minimal sample decomposition in ambient mass spectrometry is approached using ambient flash desorption mass spectrometry. The preheated stainless steel filament was driven down and up along the vertical axis in 0.3 s. At the lowest position, it touched the surface of the sample with an invasion depth of 0.1 mm in 50 ms (flash heating) and was removed from the surface (fast cooling). The heating rate corresponds to ~104 °C/s at the filament temperature of 500 °C. The desorbed gaseous molecules were ionized by using a dielectric barrier discharge ion source, and the produced ions were detected by a time-of-flight (TOF) mass spectrometer. Less-volatile samples, such as pharmaceutical tablets, narcotics, explosives, and C60 gave molecular and protonated molecule ions as major ions with thermal decomposition minimally suppressed. For synthetic polymers (PMMA, PLA, and PS), the mass spectra reflected their backbone structures because of the suppression of the sequential thermal decompositions of the primary products. The present technique appears to be suitable for high-throughput qualitative analyses of many types of solid samples in the range from a few ng to 10 μg with minimal sample consumption. Some contribution from tribodesorption in addition to thermal desorption was suggested for the desorption processes.
Figure
?  相似文献   

2.
Matrix assisted ionization of nonvolatile compounds is shown not to be limited to vacuum conditions and does not require a laser. Simply placing a solution of analyte dissolved with a suitable matrix such as 3-nitrobenzonitrile (3-NBN) or 2,5-dihydroxyacetophenone on a melting point tube and gently heating the dried sample near the ion entrance aperture of a mass spectrometer using a flow of gas produces abundant ions of peptides, small proteins, drugs, and polar lipids. Fundamental studies point to matrix-mediated ionization occurring prior to the entrance aperture of the mass spectrometer. The method is analytically useful, producing peptide mass fingerprints of bovine serum albumin tryptic digest consuming sub-picomoles of sample. Application of 100 fmol of angiotensin I in 3-NBN matrix produces the doubly and triply protonated molecular ions as the most abundant peaks in the mass spectrum. No carryover is observed for samples containing up to 100 pmol of this peptide. A commercial atmospheric samples analysis probe provides a simple method for sample introduction to an atmospheric pressure ion source for analysis of volatile and nonvolatile compounds without using the corona discharge but using sample preparation similar to matrix-assisted laser desorption/ionization.
Figure
?  相似文献   

3.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

4.
We report on a new solid phase for microextraction (SPME) of Methylene Blue (MB). It was obtained by immobilizing carboxy graphene (G-COOH) on a stainless steel wire. Scanning electron micrography showed the surface to be homogeneous, porous and wrinkled. The effects of sample solution pH, extraction time, stirring rate, desorption time and of desorption solvent on the efficiency of extraction of MB were optimized. The new SPME was coupled to electrochemiluminescence detection of MB and gave a linear analytical range from 2.7 nM to 1.3 μM, and the detection limit is 0.89 nM which is better than other methods. When considering the enrichment factor of ~20, the resulting detection limit is estimated to be 45 pM. The new SPME fiber was successfully applied to the analysis of MB in spiked real water samples. Recoveries range from 95.7 % to 113.0 %, and relative standard deviations are <5.0 %, which showed the good reproducibility of the method.
Figure
Scanning electron micrographs of G-COOH fiber coating (A: 10,000× magnification, C: 100× magnification). Laser scanning confocal microscope of G-COOH fiber coating (B, D: a distance of 200 μm)  相似文献   

5.
Quantification of monosaccharides and disaccharides in five honey samples through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using HgTe nanostructures as the matrix and sucralose as an internal standard has been demonstrated. Under optimal conditions (1× HgTe nanostructure, 0.2 mM ammonium citrate at pH 9.0), the SALDI-MS approach allows detection of fructose and maltose at the concentrations down to 15 and 10 μM, respectively. Without conducting tedious sample pretreatment and separation, the SALDI-MS approach allows determination of the contents of monosaccharides and disaccharides in honey samples within 30 min, with reproducibility (relative standard deviation <15%). Unlike only sodium adducts of standard saccharides detected, sodium adducts and potassium adducts with differential amounts have been found among various samples, showing different amounts of sodium and potassium ions in the honey samples. The SALDI-MS data reveal that the contents of monosaccharides and disaccharides in various honey samples are dependent on their nectar sources. In addition to the abundant amounts of monosaccharides and disaccharides, oligosaccharides in m/z range of 650???2700 are only detected in pomelo honey. Having advantages of simplicity, rapidity, and reproducibility, this SALDI-MS holds great potential for the analysis of honey samples.
Figure
?  相似文献   

6.
A highly sensitive method was developed for the simultaneous determination of ten sulfonamides in pork and chicken samples by monolith-based stir bar sorptive extraction (SBSE) coupled to high-performance liquid chromatography tandem mass spectrometry. The samples were freeze-dried and extracted by acetonitrile, then enriched and further extracted by SBSE which was based on poly(vinylphthalimide-co-N,N-methylenebisacrylamide) monolith (SBSE-VPMB) as coating. To achieve optimum extraction performance of SBSE for sulfonamides, several parameters, including pH value and ionic strength in the sample matrix and extraction and desorption time, were investigated in detail. Under the optimal conditions, the limits of detection (S/N?=?3) for target sulfonamides were 1.2–6.1 ng/kg in pork and 2.0–14.6 ng/kg in chicken, respectively. Real samples spiked at the concentration of 0.5 and 5.0 μg/kg showed recoveries above 55 % and relative standard deviations below 12 %. At the same time, the extraction performances of target sulfonamides on SBSE-VPMB were compared with other SBSE based on porous monolith and commercial SBSE.
Figure
?  相似文献   

7.
We report on a combination of magnetic solid-phase extraction and spectrophotometric determination of bromate. Cetyltrimethylammonium ion was adsorbed on the surface of phenyl-functionalized silica-coated Fe3O4 nanoparticles (Ph-SiO2@Fe3O4), and these materials served as the sorbent. The effects of surfactant and amount of sorbent, the composition of the desorption solution, the extraction time and temperature were optimized. Under optimized conditions, an enrichment factor of 12 was achieved, and the relative standard deviation is 2.9 % (for n?=?5). The calibration plot covers the 1–50 ng mL?1 range with reasonable linearity (r 2?>?0.998); and the limit of detection is 0.5 ng mL?1. The method is not interfered by ionic compounds commonly found in environmental water samples. It was successfully applied to the determination of bromate in spiked water samples.
Figure
Extraction of bromate ions using surfactant-coated phenyl functionalized Fe3O4 magnetic nanoparticles followed by spectrophotometric detection.  相似文献   

8.
An ultra performance liquid chromatography electrospray tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the determination of 17 antibiotics in natural waters in one single extraction and chromatographic procedure. Gradient separation conditions were optimised for 17 compounds belonging to five different antibiotic groups: quinolones (oxolinic acid, nalidixic acid, pipemidic acid, flumequine), fluoroquinolones (enoxacin, ciprofloxacin, norfloxacin, ofloxacin, enrofloxacin, sarafloxacin, danofloxacin, difloxacin, lomefloxacin), sulphonamides (sulphamethoxazole, sulphamethazine), nitro-imidazole (ornidazole) and diaminopyrimidine (trimethoprim). The separation of all compounds, obtained using a 1.7 μm particle size column (100 mm?×?2.1 mm), was achieved within 10 min time. Water samples were adjusted to pH 7 and extracted using Oasis hydrophilic–lipophilic balance (HLB) solid phase extraction cartridges. After elution with methanol and concentration, extracts were injected in a C18 column (Acquity UPLC BEH C18) and detected by tandem mass spectrometry. Average recovery from 100 ng L?1 fortified samples was higher than 70% for most of the compounds, with relative standard deviations below 20%. Performances of the method (recoveries, detection limit, quantification limit and relative standard deviation) and matrix effects were studied, and results obtained showed that method was suitable for routine analysis of antibiotics in surface water. Samples analysis from Seine River (France) confirmed the interest of antibiotic contamination evaluation in that area.
Fig. a
UPLC/MS/MS extracted ion chromatograms of a standard solution containing 17 analytes  相似文献   

9.
The use of thin-film solid-phase microextraction (SPME) as the sampling preparation step before direct analysis in real time (DART) was evaluated for the determination of two prohibited doping substances, cocaine and methadone, in urine samples. Results showed that thin-film SPME improves the detectability of these compounds: signal-to-blank ratios of 5 (cocaine) and 13 (methadone) were obtained in the analysis of 0.5 ng/ml in human urine. Thin-film SPME also provides efficient sample cleanup, avoiding contamination of the ion source by salt residues from the urine samples. Extraction time was established in 10 min, thus providing relatively short analysis time and high throughput when combined with a 96-well shaker and coupled with DART technique.
Figure
Schematic protocol for determination of cocaine and methadone in urine by thin-film SPME and DART-MS analysis  相似文献   

10.
Laser desorption postionization mass spectrometry (LDPI-MS) imaging is demonstrated with a 10.5 eV photon energy source for analysis and imaging of small endogenous molecules within intact biofilms. Biofilm consortia comprised of a synthetic Escherichia coli K12 coculture engineered for syntrophic metabolite exchange are grown on membranes and then used to test LDPI-MS analysis and imaging. Both E. coli strains displayed many similar peaks in LDPI-MS up to m/z 650, although some observed differences in peak intensities were consistent with the appearance of byproducts preferentially expressed by one strain. The relatively low mass resolution and accuracy of this specific LDPI-MS instrument prevented definitive assignment of species to peaks, but strategies are discussed to overcome this shortcoming. The results are also discussed in terms of desorption and ionization issues related to the use of 10.5 eV single-photon ionization, with control experiments providing additional mechanistic information. Finally, 10.5 eV LDPI-MS was able to collect ion images from intact, electrically insulating biofilms at ~100 μm spatial resolution. Spatial resolution of ~20 μm was possible, although a relatively long acquisition time resulted from the 10 Hz repetition rate of the single-photon ionization source.
Figure
Neutral species laser desorbed from cocultured biofilms undergo single photon ionization by VUV radiation and resultant ions are detected by time-of-flight mass spectrometry  相似文献   

11.
A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography–mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95 %). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.
Figure
Doping of tube with derivatizing mixture before sampling  相似文献   

12.
An isothermal cross-priming amplification (CPA) assay for Agrobacterium tumefaciens nopaline synthase terminator (T-Nos) was established and investigated in this work. A set of six specific primers, recognizing eight distinct regions on the T-Nos sequence, was designed. The CPA assay was performed at a constant temperature, 63 °C, and detected by real-time fluorescence. The results indicated that real-time fluorescent CPA had high specificity, and the limit of detection was 1.06?×?103 copies of rice genomic DNA, which could be detected in 40 min. Comparison of real-time fluorescent CPA and conventional polymerase chain reaction (PCR) was also performed. Results revealed that real-time fluorescent CPA had a comparable sensitivity to conventional real-time PCR and had taken a shorter time. In addition, different contents of genetically modified (GM)-contaminated rice seed powder samples were detected for practical application. The result showed real-time fluorescent CPA could detect 0.5 % GM-contaminated samples at least, and the whole reaction could be finished in 35 min. Real-time fluorescent CPA is sensitive enough to monitor labeling systems and provides an attractive method for the detection of GMO.
Figure
?  相似文献   

13.
Solid-phase microextraction (SPME) based on carboxylated single-walled carbon nanotube fibers was used to extract several chlorophenols (CPs) and organochlorine pesticides (OCPs) from aqueous samples prior to their determination by GC with electron capture detection. The main parameters affecting microextraction (temperature, time, stirring rate and salting-out effect) and the conditions of the thermal desorption in the GC injector were optimized. Compared with commercial SPME fibers, the fiber presented better selectivity and sensitivity. Linear response was found for the concentration range between 2 and 1000 ng L?1 (20–1000 ng L?1 for CPs), and the limits of detection were in the range from 0.07 to 4.36 ng L?1. The repeatability expressed as relative standard deviation ranged from 4.1 % to 8.2 % and the fiber-to-fiber reproducibility for four prepared fibers was between 6.5 % and 10.8 %. The method was successfully applied to the analysis of CPs and OCPs in lake water and waste water samples. Recovery was tested with spiked lake water and waste water samples, with values ranging from 89.7 % to 101.2 % in case of waste water samples.
Figure
Raman spectra: (A) SWNTs, and (B) Oxidized SWNTs  相似文献   

14.
A surface-assisted laser desorption/ionization (SALDI) source is coupled to the Orbitrap mass analyzer; the instrumental approach is tested for the analysis of rhenium (Re) and osmium (Os) complexes with 8-mercaptoquinoline. Silicon (Si) material obtained by laser treatment of monocrystalline Si is used as SALDI substrate. All studied complexes are detected as radical cations, with no protonated molecules. The comparison of SALDI, matrix-assisted laser desorption/ionization (MALDI), and direct laser desorption/ionization (LDI) on metal plates in the same instrumental setup demonstrated that the detection of the studied complexes using SALDI provides the highest sensitivity. The ability to analyze samples rapidly, high purity of spectra, and good analytical parameters make SALDI coupled to the Orbitrap mass analyzer a potentially powerful tool for the detection of Re and Os complexes and related organic, UV-absorbing compounds.
Figure
?  相似文献   

15.
We describe a simple method for the simultaneous determination of organolead and organomanganese compounds in seawater samples. It is based on ultrasound-assisted emulsification microextraction. Trimethyllead, triethyllead, tetraethyllead, cyclopentadienylmanganese tricarbonyl and its methyl derivative were separated and determined using gas chromatography and mass spectrometry. Trimethyllead and triethyllead were derivatized with sodium tetraphenylborate before being submitted to the preconcentration step. Detection limits ranged from 7.0 to 41 ng L?1 depending on the compound. Recoveries ranged from 84 to 118 %, depending on the compound and the sample analyzed. Seawater samples were collected at different sites of the Cartagena Bay and none of the target analytes were found at levels above the corresponding detection limits.
Figure
The most relevant organomanganese and organolead compounds can be monitorized in seawaters by using a relatively simple instrumentation (Gas chromatography–mass spectrometry). Advantage is taken of ultrasound-assisted emulsification microextraction that involves minimal amounts of organic solvents  相似文献   

16.
Food and contaminated indoor environments are the most relevant sources of human exposure to polyhalogenated chemicals. This study analyzed for the first time fat residues in kitchen hoods for contaminations with polyhalogenated compounds. A wide range of contaminants was detected in all kitchen hoods (n?=?15) and most of them could be quantified. Between 0.2 and 18 μg polyhalogenated chemicals/g fat were detected, with chlorinated paraffins being the most relevant contaminant group. Aside from the chlorinated paraffins, each kitchen hood fat sample showed a distinct fingerprint. A wide range of old and current-use brominated flame retardants were also detected in the samples. In addition to these contaminants originating from their use in indoor equipment, residues of organochlorine pesticides and semi-volatile halogenated natural products verified that cooking of food, accompanied with the release of contaminants from the heated food, was another relevant source of contamination. Re-analyses of two samples after 3 months only resulted in small variations in contaminant pattern and concentrations. Therefore, fat from kitchen hoods is proposed as an easily accessible matrix to assess contamination of these hazardous polyhalogenated chemicals.
Figure
Picture of a kitchen hood and its filter. The fat collected from kitchen hood filters contained plenty of polyhalogenated chemicals  相似文献   

17.
A novel rapid (20 min) fluorescent lateral flow test for chloramphenicol (CAP) detection in milk was developed. The chosen format is a binding-inhibition assay. Water-soluble quantum dots with an emission peak at 625 nm were applied as a label. Milk samples were diluted by 20 % with phosphate buffer to eliminate the matrix effect. The result of the assay could be seen by eye under UV light excitation or registered by a portable power-dependent photometer. The limit of CAP detection by the second approach is 0.2 ng/mL, and the limit of quantitation is 0.3 ng/mL.
Figure
Principle of proposed immunoassay of chloramphenicol using quantum dots  相似文献   

18.
A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol–water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar–polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng?L?1, except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples.
Figure
Schematic diagram of the On-line solid-phase microextraction  相似文献   

19.
A micellar electrokinetic chromatography method was developed for determination of 15 suspected fragrance allergens and preservatives. The target compounds are widely used as ingredients in many personal care products, and all of them are included in the European Regulation concerning cosmetic products. The method was optimized by using a central composite experimental design and response surface methodology. A modified chromatographic response function was defined to weigh the terms in the response function adequately. After optimization of experimental conditions, a background electrolyte of 100 mM sodium dodecyl sulphate and 24 mM sodium tetraborate and pH 9.0 was selected for the separation of the analytes. The developed methodology was evaluated in terms of linearity, limits of detection and quantification, precision and accuracy, showing appropriate values (i.e., R 2?=?≥0.99 and accuracy of 89–115 %). Finally, applicability of the micellar electrokinetic chromatography method was assessed by successfully quantifying fragrance allergens and preservatives in commercial personal care products. The most commonly found analyte was linalool (48.3 % of samples) followed by benzoic acid (37.6 %). All samples contained at least one of the target compounds, thus confirming the ubiquity of fragrance allergens and preservatives in personal care products.
Figure
Scheme of data transformation to obtain the modified chromatogoraphic response function (MCRF)  相似文献   

20.
We have prepared a novel caffeine imprinted polymer on a stir bar that can be used for selective extraction of caffeine, theobromine and theophylline from beverages. The polymerization time and quantities of reagents (template, cross-linker, porogenic solvent) were optimized. The morphology of the molecularly imprinted polymer-coating was studied by scanning electron microscopy and Fourier transform IR spectroscopy. A rapid and sensitive method was worked out for the extraction of caffeine, theobromine and theophylline from beverages by using the molecularly imprinted stir bar followed by HPLC analysis. The effects of extraction solvent, stirring speed, desorption solvent, adsorption and desorption time were optimized. The method displays a linear response in the 5–150 μg L?1 caffein concentration range, with a correlation coefficient of >0.9904. The recoveries for three analytes in tea, carbonated and functional beverages were 91–108 %, 90–110 % and 93–109 %, with relative standard deviations ranging from 3.6–5.7 %, 3.5–7.9 % and 3.2–7.9 %, respectively.
Figure
A molecularly imprinted stir bar was prepared and applied for the selective extraction and sensitive determination of caffeine and its analogues in beverages by coupling with HPLC. The limits of detection were in the range of 1.24–2.25 μg L?1 (S/N?=?3) which are lower than those in published papers  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号