首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An environmentally friendly methodology has been developed for quality control analysis of emulsifiable concentrate pesticide formulations containing Malathion as active ingredient, using flow injection analysis (FIA)-Fourier transform infrared (FTIR) spectrometry. Five microlitres samples were directly injected into a 3 ml closed FIA manifold, in which 2 ml of CHCl3 was re-circulated at 1.96 ml min−1. After homogenisation and sample measurement, 2 μl volumes of a Malathion standard were injected, taking absorbance measurements after each injection. Peak height of the chemigrams, established from peak area values between 1027 and 1017 cm−1, corrected with a baseline fixed from 1087 to 993 cm−1 were employed for Malathion quantification using the standard addition approach, after reaching the steady state for every injection. A limit of detection of 12 μg ml−1 was achieved. Results found by standard addition-FTIR in commercially available samples showed a good correlation with those obtained by the reference gas chromatography-flame ionisation detection procedure.  相似文献   

2.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

3.
A.S. Alves Ferreira 《Talanta》2007,72(3):1223-1229
This paper deals on the determination of Strychnine, a potent and dangerous pesticide and the analytical procedure is based on the photo-induced chemiluminescence of the pesticide by means of the Multicommutation continuous-flow methodology. Small segments of the pesticide solution were sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. The required time of UV irradiation was obtained by stopped-flow during 150 s; then, the resulting solution formed alternated segments with the oxidizing solution containing 5 × 10−3 mol l−1 Ce(IV) in 0.6 mol l−1 nitric acid. The calibration range, from 2 μg l−1 to 50 mg l−1, resulted in a linear behaviour over the range 25 μg l−1 to 20 mg l−1 and fitting the equation: I = 4706x + 624 with a correlation coefficient of 0.9955. The limit of detection was 2 μg l−1 and the sample throughput 15 h−1. After testing the influence of a large series of potential interferents, the method was applied to different kinds of samples.  相似文献   

4.
Fourier transform infrared (FTIR) spectrometric methodology has been developed for the simultaneous determination of Folpet and Metalaxyl in pesticide formulations. The method involves the extraction of both active principles by sonication of the sample with CHCl3 and direct measurement of the absorbance using peak height values at 1798 cm−1 corrected with a baseline defined at 1810 cm−1 for Folpet, and peak area data established from 1677 to 1667 cm−1 corrected using a baseline from 1692 to 1628 cm−1 for Metalaxyl. Limits of detection (3 s) values of 17 and 16 μg g−1 were found for Folpet and Metalaxyl, respectively, with results comparable with those found by liquid chromatography with UV detection. The new method involves a considerable decrease in solvent consumption. The automation of the procedure by incorporating on-line dissolution and filtration of the samples allows complete mechanisation of the method and improves the safety of operation.  相似文献   

5.
Nicotine was selected as the target molecule for monitoring of the smoking process by multicommutation Fourier Transform Infrared spectroscopy (FTIR). The method involved the use of CHCl3 for on-line extraction of nicotine from tobacco, cigarette filters and tobacco ash from NH4OH alkalinized samples, and absorbance measurement of the characteristic band at 1316 cm−1 in the stopped-flow mode, by obtaining the peak area in the range between 1334 and 1300 cm−1. Under the best operational conditions, the procedure developed provided a detection limit of 0.05 mg mL−1 nicotine, corresponding to 0.5 mg g−1 in the solid sample, a relative standard deviation less than 2.5%, and a sampling frequency of 12 determinations h−1. It can be concluded that nicotine migrates in the smoke mainstream towards the filter during the smoking process. The smoking of cigarettes and cigars is different. Nicotine is retained weakly by both tobacco and filter in the case of cigarettes, and strongly by the unburned tobacco in cigars. The incomplete smoking of cigars and cigarettes reduces nicotine intake and thus reduces the additive effect.  相似文献   

6.
Two different strategies for Buprofezin determination, an off-line extraction and stopped-flow determination and an automated procedure, based on the on-line extraction of Buprofezin samples with chloroform and flowing action analysis-fourier transform infrared (FIA-FT-IR) spectrometric measurement of the extracts, have been developed. For the treatment of the off-line extraction mode, data a three-factor partial least squares (PLSs) calibration was developed, using the region from 1465.7 to 1342.3 cm−1 with a single point baseline defined at 2051.9 cm−1 and based on the use of chloroform solutions of Buprofezin. The method provides a R.S.D. <0.1%, recoveries of the order of 100% and generates 25 ml of CHCl3 waste for each sample.On the other hand, the recommended FIA method provided a 3 s limit of detection of 20 μg ml−1, which corresponds to 0.12% (w/w) in the solid sample, a repeatability of 0.8% as R.S.D., and a maximum sampling frequency for the whole procedure of 6 h−1.The waste generation, being lower than the off-line strategy, is only 3 ml of CHCl3 per sample.  相似文献   

7.
J. Kuligowski 《Talanta》2008,77(2):779-785
An on-line gradient reversed phase liquid chromatography-Fourier transform infrared spectrometry (LC-FTIR) method was developed for the determination of fructose, glucose, sucrose and maltose in beverages. Improved chromatographic resolution was obtained using a linear gradient from 75 to 55% (v/v) acetonitrile in water in 15 min. Changes in the background spectra were corrected employing “univariate background correction based on the use of a reference spectra matrix” (UBC-RSM) and using the ratio of absorbance (AR) at 2256 and 2253 cm−1 for the identification of the eluent spectra within the RSM. The method provided limits of detection in the order of 0.75 mg ml−1. The precision (as relative standard deviation) ranged between 3.3 and 4.1% for glucose and fructose, respectively at a concentration level of 3.0 mg ml−1. Quantitative recovery values on spiked samples confirmed the accuracy of the method. A set of samples from the Spanish market were analysed to test the suitability of the procedure.  相似文献   

8.
An on-line system with vapour generation (VG) and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of free ammonium and organic nitrogen in agrochemical formulations containing hydrolyzed proteins. Commercial samples were digested, in batch mode, with sulphuric acid and the obtained solution was alkalinized on-line to transform the NH4+ to NH3 that was continuously monitored by FTIR. Free ammonium was determined in the same system after simple dilution of undigested samples with water. Different gas phase separators were assayed in order to introduce gaseous NH3 into a home made IR gas cell of 10 cm pathlength, where the corresponding FTIR spectra were acquired by accumulating 10 scans per spectrum. The 967.0 cm−1 band was used for the quantification of ammonia. The figures of merit of the proposed method involve a linear range up to 100 mg L−1, a limit of detection (3σ) of 1.4 mg L−1 of N, a limit of quantification (10σ) of 4.8 mg L−1 of N, a precision (R.S.D.) of 3.0% for 10 replicate determinations of a 10.0 mg L−1 of N and a sample measurement frequency of 60 h−1. The method was successfully applied to the determination of free ammonium and total N in commercial amino acid formulations and results compare well with those obtained by the Kjeldhal method.  相似文献   

9.
The molecular structure of 1,1-bis(trimethylsilylethynyl)cyclopropane has been studied by the gas electron diffraction method, by vibrational spectroscopic methods and by ab initio calculations at the RHF and MP2 levels. A scaled quantum-chemical force field was used for band assignment in the experimental IR (4000-100 cm−1) and Raman (4000-200 cm−1) spectra. The root-mean-square vibrational amplitudes and harmonic shrinkage corrections were calculated taking into account non-linear relations between Cartesian and internal vibrational coordinates at the level of first-order perturbation theory (h1) and with the use of the traditional scheme (h0).  相似文献   

10.
This work evaluates the use of near-infrared (NIR) overtone regions to determine biodiesel content, as well potential adulteration with vegetable oil, in diesel/biodiesel blends. For this purpose, NIR spectra (12,000–6300 cm−1) were obtained using three different optical path lengths: 10 mm, 20 mm and 50 mm. Two strategies of regression with variable selection were evaluated: partial least squares (PLS) with significant regression coefficients selected by Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with wavenumber selection by successive projections algorithm (MLR/SPA). For comparison, the results obtained by using PLS full-spectrum models are also presented. In addition, the performance of models using NIR (1.0 mm optical path length, 9000–4000 cm−1) and MIR (UATR – universal attenuated total reflectance, 4000–650 cm−1) spectral regions was also investigated. The results demonstrated the potential of overtone regions with MLR/SPA regression strategy to determine biodiesel content in diesel/biodiesel blends, considering the possible presence of raw oil as a contaminant. This strategy is simple, fast and uses a fewer number of spectral variables. Considering this, the overtone regions can be useful to develop low cost instruments for quality control of diesel/biodiesel blends, considering the lower cost of optical components for this spectral region.  相似文献   

11.
Thanyarat Chuesaard 《Talanta》2009,79(4):1181-1187
An interfacing has been developed to connect a spectrophotometer with a personal computer and used as a readout system for development of a simple, rapid and sensitive reversed flow injection (rFI) procedure for chlorate determination. The method is based on the oxidation of indigo carmine by chlorate ions in an acidic solution (dil. HCl) leading to the decrease in absorbance at 610 nm. The decrease in absorbance is directly related to the chlorate concentration present in the sample solutions. Optimum conditions for chlorate were examined. A linear calibration graph over the range of 0.1-0.5 mg L−1 chlorate was established with the regression equation of Y = 104.5X + 1.0, r2 = 0.9961 (n = 6). The detection limit (3σ) of 0.03 mg L−1, the limit of quantitation (10σ) of 0.10 mg L−1 and the RSD of 3.2% for 0.3 mg L−1 chlorate (n = 11) together with a sample throughput of 92 h−1 were obtained. The recovery of the added chlorate in spiked water samples was 98.5 ± 3.1%. Major interferences for chlorate determination were found to be BrO3, ClO2, ClO and IO3 which were overcome by using SO32− (as Na2SO3) as masking agent. The method has been successfully applied for the determination of chlorate in spiked water samples with the minimum reagent consumption of 14.0 mL h−1. Good agreement between the proposed rFIA and the reference methods was found verified by Student's t-test at 95% confidence level.  相似文献   

12.
In this work, a flow analysis system with hydride generation and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of antimony in pharmaceuticals. The method is based on the on-line mineralization/oxidation of the organic antimonials present in the sample and pre-reduction of Sb(V) to Sb(III) with K2S2O8 and KI, respectively; prior to the stibine generation. The gaseous SbH3 is separated from the solution in a gas phase separator, and transported by means of a nitrogen carrier into a short pathway (10 cm) IR gas cell, where the corresponding FTIR spectrum is acquired by accumulating 3 scans in a continuous mode. The 1893 cm−1 band was used for the quantification of the antimony. The procedure is carried out in a closed system, which reduces sample handling and makes possible the complete automation of the antimony determination. The figures of merit of the proposed method (linear range: 0-600 mg l−1, limit of detection (3σ)=0.9 mg l−1, limit of quantification (10σ)=3 mg Sb l−1, precision (R.S.D.) less than 1% and sample frequency=28 h−1), are appropriate for the designed application. Furthermore, precise and accurate results were found for the analysis of different antimonial pharmaceutical samples, indicating that the methodology developed represents a valid alternative for the determination of antimony in pharmaceuticals, which could be suitable for the routine control analysis.  相似文献   

13.
The potential of near infrared (NIR) spectroscopy in characterization of organically modified clay minerals is introduced. Selected organo-clays, possibly perspective fillers in clay polymer nanocomposites, were prepared from Na-montmorillonite and different surfactants containing octylammonium chain(s), hexadecylammonium chain(s) or a benzene ring with or without a reactive double bond. Based on the stretching (ν) and bending (δ) vibrations observed in the middle IR (MIR) region, the first overtone (2νXH) and combination (ν + δ)XH modes of XH groups (X = O, C, N) are identified. The effect of larger alkylammonium cations on the vibrations of Si-O and OH bonds in montmorillonite layers is observed. The changes in the intensity of the (ν + δ)H2O band near 5250 cm−1 allows for comparison of the amount of water adsorbed on the montmorillonite surface. The water content decreases with the size of the organic cation reflecting increasing hydrophobicity of the montmorillonite surface. The NIR region shows the 2νCH3 and 2νCH2 bands in the 5900-5500 cm−1 region, an upward shift is observed for the complex band due to 2νCH(Ar) of aromatic benzene ring. The NIR spectra are extremely useful in identification of NH2+, NH+ and vinyl groups, which are difficult to recognize in the MIR spectra of organo-clays due to overlapping with other absorption bands. The intense bands corresponding to overtones and combination vibrations of NH3+ and NH2+ groups are found in the 6600-6050 cm−1 and 5000-4600 cm−1 regions, the (ν + δ)NH+ is unambiguously identified near 4750 cm−1. The characteristic band assigned to 2νCH2 in H2CC is detected near 6130 cm−1.  相似文献   

14.
Lecithin and soybean oil in dietary supplements were determined by Fourier transform infrared spectrometry transmission measurements in dichloromethane in combination with a partial least squares (PLS) regression. Two different PLS models were developed, using 16 synthetic mixtures of analytes in dichloromethane, making measurements in the spectral range from 931.8 to 1252.3 cm−1 for lecithin and from 911.4 to 1246.9 cm−1 and 1695.3 to 1774.5 cm−1 for soybean oil. Seven products from the Spanish market with lecithin concentrations between 21.1% and 99.1% and soybean oil concentrations between 0% and 37.2% were analyzed by the proposed method and the data was compared to a chromatographic reference procedure obtaining accurate results. For samples spiked with amounts between 50 and 250 mg of lecithin and soybean oil recovery percentages between 98.0% and 102.1% and between 93.6% and 102.0% with an average precision of 0.35% and 0.41% were achieved for lecithin and soybean oil, respectively. This method can be applied for the quality control of dietary supplements.  相似文献   

15.
In this work, a new rapid method for the determination of 135 pesticide residues in green and black dry tea leaves and stalks employing gas chromatography coupled to tandem mass spectrometry (GC–MS/MS) with a triple quadrupole was developed and validated. A substantial simplification of sample processing prior to the quantification step was achieved: after addition of water to a homogenised sample, transfer of analytes into an acetonitrile layer was aided by the addition of inorganic salts. Bulk co-extracts, contained in the crude organic extract obtained by partition, were subsequently removed by liquid–liquid extraction using hexane with the assistance of added 20% (w/w) aqueous NaCl solution. The importance of matrix hydration prior to the extraction for achieving good recoveries was demonstrated on tea samples with incurred pesticide residues. For most of the analytes, recoveries in the acceptable range of 70–120% and repeatabilities (relative standard deviations, RSDs) ≤20% were achieved for both matrices at spiking levels of 0.01, 0.1 and 1 mg kg−1. Under optimised GC–MS/MS conditions, most of the analytes gave lowest calibration level ≤0.01 mg kg−1, permitting the control at the maximum residue levels (MRLs) laid down in Regulation (EC) No 396/2005. The developed method was successfully applied to the determination of pesticide residues in real tea samples.  相似文献   

16.
The present paper is dealing with an analytical strategy based on coupling photodegradation, chemiluminescence and multicommutation continuous-flow methodology for the determination of the pesticide Propanil, a common herbicide. The pesticide solution is inserted as small segments sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. Both flow-rates (sample and medium) are adjusted to required time for photodegradation, 2.0 min; and then, the resulting solution is also sequentially inserted as segments alternated with segments of the oxidizing solutions system, 1.00 × 10−4 mol l−1 potassium permanganate in 2.00 mol l−1 sulphuric acid medium. The calibration range, from 10 μg l−1 to 25 mg l−1, resulted in a linear behaviour over the range 10 μg l−1-5 mg l−1 and fitting the linear equation: I = 780.30C + 95.28; correlation coefficient 0.9999. The limit of detection was 8 μg l−1 and the sample throughput 20 h−1. After testing the influence of a large series of potential interferents the method is applied to water samples obtained from different places and to one formulation. The method is valid for the determination of other pesticides from the same chemical family, namely: alachlor, flumetsulam, furalaxyl and ofurace. Calibration graphs, limits of detection, repeatability and determination in water samples are obtained for each reported pesticide.  相似文献   

17.
Wu X  Chen X  Hu Z 《Talanta》2003,59(1):115-121
A high-performance liquid chromatographic (HPLC) method is described for the simultaneous determination of honokiol and magnolol in rat plasma. The plasma was deproteinized with acetonitrile which contained an internal standard (diphenyl) and was separated from the aqueous layer by adding sodium chloride. Honokiol and magnolol are extracted into the acetonitrile layer with high yield, and determined by reversed-phase HPLC and ultraviolet detection. The limits of quantitation for honokiol and magnolol were 13 and 25 ng ml−1 in plasma, respectively, and recovery of both analytes was greater than 93%. The assay was linear from 20 to 200 ng ml−1 for honokiol and from 40 to 400 ng ml−1 for magnolol. Variation over the range of the standard curve was less than 15%. The method was used to determine the concentration-time profiles of honokiol and magnolol in the plasma following rectal administration of Houpo extract at a dose of 245 mg kg−1, equivalent to 13.5, 24.4 mg kg−1 of honokiol and magnolol, respectively.  相似文献   

18.
A multi-pumping flow system (MPFS) for the spectrophotometric determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples is proposed. The determination of orthophosphate is based on the vanadomolybdate method. In-line ultraviolet photo-oxidation is employed to mineralise organic phosphorus to orthophosphate prior to detection. A solenoid valve allows the deviation of the flow towards the UV-lamp to carry out the determination of organic phosphorus.Calibration was found to be linear up to 20 mg P L−1, with a detection limit (3sb/S) of 0.08 mg P L−1, an injection throughput of 75 injections h−1 and a repeatability (R.S.D.) of 0.6% for the direct determination of orthophosphate. On the other hand, calibration graphs were linear up to 40 mg P L−1, with a detection limit (3sb/S) of 0.5 mg P L−1, an injection throughput of 11 injections h−1 and a repeatability (R.S.D.) inferior to 2.3% for the procedures involving UV photo-oxidation.  相似文献   

19.
A sequential injection analysis (SIA) using lab-on-valve with air segmentation and spectrophotometric detection was designed for copper(II) determination. It is based on the reaction of copper(II) and 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (Zincon) in a weak alkaline solution between the air zones. Beer's Law was obeyed over the range of 0.1-2.0 mg L−1 copper(II) with a correlation coefficient 0.9985 and a slope of 0.2893 absorbance unit/mg L−1. The relative standard deviation was 2.0% for a series of 10 measurements of 0.5 mg L−1 copper(II) solution. The detection limit (3 S/N) and the limit of quantification (LOQ) were 0.05 and 0.17 mg L−1 respectively. This method has been successfully applied to determination of copper(II) in wastewater with a sample throughput of 120 h−1. The method is superior to the batchwise method in that it provides fully automation, rapidity, less reagents and sample consumption with little waste generation.  相似文献   

20.
Non-chromatographic speciation of toxic arsenic in fish   总被引:1,自引:0,他引:1  
A rapid, sensitive and economic method has been developed for the direct determination of toxic species of arsenic present in fish and mussel samples. As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations without the need of a chromatographic previous separation. The method is based on the extraction of arsenic species from fish through sonication with HNO3 3 mol l−1 and 0.1% (m/v) Triton and washing of the solid phase with 0.1% (m/v) EDTA, followed by direct measurement of the corresponding hydrides in four different experimental conditions. The limit of detection of the method was 0.62 ng g−1 for As(III), 2.1 ng g−1 for As(V), 1.8 ng g−1 for MMA and 5.4 ng g−1 for DMA, in all cases expressed in terms of sample dry weight. The mean relative standard deviation values (R.S.D.) in actual sample analysis were: 6.8% for As(III), 10.3% for As(V), 8.5% for MMA and 7.4% for DMA at concentration levels from 0.08 mg kg−1 As(III) to 1.3 mg kg−1 DMA. Recovery studies provided percentages greater than 93% for all species in spiked samples. The analysis of SRM DORM-2 and CRM 627 certified materials evidenced that the method is suitable for the accurate determination of arsenic species in fish.  相似文献   