首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 786 毫秒
1.
An immunoaffinity-based method was developed to determine zearalenone in corn. Corn samples were extracted in acetonitrile-water (90 + 10, v/v), applied to an immunoaffinity column, and eluted with methanol. The isolated toxin was quantitated either by reaction with aluminum chloride hexahydrate (AlCl3.6H2O) prior to measurement with a fluorometer or injection into a liquid chromatographic (LC) system with a fluorescence detector. Performance was evaluated in terms of antibody specificity, limit of detection, percentage recovery, precision, column capacity, assay linearity, and comparison with AOAC Official Method 985.18. With the immunoaffinity column cleanup procedure, only zearalenone and its metabolites were recognized by the antibody (> or = 75% recovery). Limits of detection were 0.10 microgram/g for the fluorometer and 0.10 or 0.0025 microgram/g (sensitive method) for the LC method. Percentage recovery averaged 105% (fluorometer) and 93% (LC method), with average relative standard deviations (RSDs) of 15.7 and 9.3%. Naturally contaminated samples gave comparable RSDs of 8.3 and 9.9% for the fluorometer and LC methods, respectively. Column capacity was 4.0 micrograms with 89% recovery. Assay linearity was comparable for both methods (r2 = 0.998). Optimum assay ranges were 0.10-5.0 micrograms/g for the fluorometer and 0.10-50 or 0.0025-5.0 micrograms/g (sensitive method) for the LC method. Comparative analysis of 17 naturally contaminated corn samples using Zearala Test LC and the official AOAC LC method for detection of zearalenone showed that Zearala Test is statistically comparable to the AOAC Official Method 985.18 (r2 = 0.747).  相似文献   

2.
An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatography (LC) method for the determination of zearalenone (ZON) in a variety of cereals and cereal products at proposed European regulatory limits. The test portion is extracted with acetonitrile:water. The sample extract is filtered, diluted, and applied to an affinity column. The column is washed, and ZON is eluted with acetonitrile. ZON is quantified by reversed-phase LC with fluorescence detection. Barley, wheat and maize flours, polenta, and a maize-based baby food naturally contaminated, spiked, and blank (very low level) were sent to 28 collaborators in 9 European countries and 1 collaborator in New Zealand. Participants were asked to spike test portions of all samples at a ZON concentration equivalent to 100 microg/kg. Average recoveries ranged from 91-111%. Based on results for 4 artificially contaminated samples (blind duplicates) and 1 naturally contaminated sample (blind duplicate), the relative standard deviation for repeatability (RSDr) ranged from 6.9-35.8%, and the relative standard deviation for reproducibility (RSDR) ranged from 16.4-38.2%. The method showed acceptable within- and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values <1.7.  相似文献   

3.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone-water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP-LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within- and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.  相似文献   

4.
An interlaboratory trial for determination of zearalenone (ZON) in baby food and animal feed was conducted. The study involved 39 participants in 16 European Union member states, as well as Turkey, Uruguay, and China, representing a cross-section of industry, and official food control and research institutes. The method is based on immunoaffinity column cleanup followed by high-performance liquid chromatography using fluorimetry (HPLC-FI). The test portion of the sample is extracted with methanol-water (75 + 25, v/v). The sample extract is filtered, diluted, and passed over an immunoaffinity column. ZON is eluted with methanol. The separation and determination of ZON is performed by reversed-phase HPLC-FI with an excitation wavelength of 274 nm and an emission wavelength of 446 nm. Test portions of the samples were spiked at levels of 20 and 30 microg/kg ZON in baby food and at levels of 100 and 150 microg/kg ZON in animal feed. Mean recoveries from each participant ranged from 78 to 119% with an average value of 92% for baby food and from 51 to 122% with an average value of 74% for animal feed. Based on results for spiked samples (blind duplicates at 2 levels), as well as naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in baby food ranged from 2.8 to 9.0%. For animal feed, this value ranged from 5.7 to 9.5%. The relative standard deviation for reproducibility (RSDR) in baby food ranged from 8.2 to 13.3%, and for animal feed this value ranged from 15.5 to 21.4%. The Horwitz ratio (HorRat) in baby food ranged from 0.3 to 0.4, and for animal feed this value ranged from 0.6 to 0.9. The method showed acceptable within- and between-laboratory precision for each matrix, as required by European legislation.  相似文献   

5.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.  相似文献   

6.
An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of deoxynivalenol in a variety of cereals and cereal products at proposed European regulatory limits. The test portion was extracted with water. The sample extract was filtered a applied to an immunoaffinity column. After being washed with water, the deoxynivalenol was eluted with acetonitrile or methanol. Deoxynivalenol was quantitated by reversed-phase LC with UV determination. Samples of artificially contaminated wheat-flour, rice flour, oat flour, polenta, and wheat based breakfast cereal, naturally contaminated wheat flour, and blank (very low level) samples of each matrix were sent to 13 collaborators in 7 European countries. Participants were asked to spike test portions of all samples at a range of deoxynivalenol concentrations equivalent to 200-2000 ng/g deoxynivalenol. Average recoveries ranged from 78 to 87%. Based on results for 6 artificially contaminated samples (blind duplicates), the relative standard deviation for repeatability (RSDr) ranged from 3.1 to 14.1%, and the relative standard deviation for reproducibility (RSDR) ranged from 11.5 to 26.3%. The method showed acceptable within-laboratory and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values < 1.3.  相似文献   

7.
Different extraction and clean-up techniques used before HPLC analysis were compared in order to obtain a reliable method for the quantitative determination of zearalenone (ZEA) and α-zearalenol (α-ZOL) in animal feed. Immunoaffinity clean-up was compared to C18 and Florisil column clean-up. Extracted samples were analysed by reversed-phase HPLC with fluorescence detection (λex=274 nm, λem=440 nm). A mobile phase of acetonitrile:water (50:50 (v/v)) and a flow-rate of 1.0 ml min−1 resulted in a good separation between ZEA and α-ZOL. Using immunoaffinity clean-up the linear range was between 25 and 600 μg kg−1 for ZEA and α-ZOL in maize. Intra-laboratory coefficients of variation (CV) (under repeatability conditions) were 9.16% for ZEA and 2.18% for α-ZOL. Recoveries for spiked ZEA and α-ZOL samples ranged from 89 to 110% with CVs between 5.2 and 11.2% (under within-laboratory reproducibility conditions). Using C18 and Florisil solid-phase clean-up, matrix interference was too high. Therefore, naturally contaminated animal feed samples were analysed using the developed HPLC method coupled to the immunoaffinity clean-up.  相似文献   

8.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B, in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol-water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and  相似文献   

9.
The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.  相似文献   

10.
To evaluate a clean-up method of detecting ochratoxin A (OTA) by HPLC, the performances of two different clean-up columns, an immunoaffinity column and a multifuntional column were compared in an inter-laboratory study. As samples, un-contaminated wheat, corn grits, green coffee beans and naturally contaminated raisins were used. The recovery test was performed at two different concentrations of OTA (0.5 and 5.0 μg/kg) except for naturally contaminated raisins. Using the immunoaffinity column, the recovery rates, and relative standard deviations for repeatability (R.S.D.r) and reproducibility (R.S.D.R) for wheat, corn grits and green coffee beans ranged 59.0-85.8, 4.2-7.8 and 22.9-29.2%, respectively. For naturally contaminated raisins, recovery, R.S.D.r and R.S.D.R were 84.1, 1.8 and 5.1%, respectively. Using the multifunctional column, the recovery rates, R.S.D.r and R.S.D.R for wheat, corn grits and green coffee beans ranged 80.8-185.0, 0.7-6.9 and 15.2-33.9%, respectively. For naturally contaminated raisins, the recovery, R.S.D.r and R.S.D.R were 128.7, 1.1 and 3.7%, respectively. The results suggest that a multifunctional column could be used to detect OTA in wheat and corn grits at a concentration as low as 0.5 μg/kg; however, it was difficult to detect OTA in green coffee beans and raisins at such a low level. Although an immunoaffinity column could be used for all the test samples in this study from a low level to a high level, the recovery rates were lower than with a multifunctional column.  相似文献   

11.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.  相似文献   

12.
A simple and accurate method to quantify the mycotoxin deoxynivalenol (DON) in wheat is described. The method uses immunoaffinity chromatography for DON isolation and liquid chromatography (LC) for toxin detection and quantification. Wheat samples are extracted in water, filtered twice and applied to an immunoaffinity column. Following a water wash, DON is eluted from the column with methanol and injected onto an LC system with a UV detector for quantification. Test performance was evaluated in terms of antibody specificity, limit of detection, percentage recovery, precision, column capacity, assay linearity and comparison with the GC-electron-capture detection (ECD) method of Tacke and Casper. Specificity of the immunoaffinity column cleanup procedure was confirmed with only DON (>80%) and its 15-C derivatives (40-50%) being recognized by the antibody while 3-C DON derivatives, nivalenol, T-2 and fusarenon-X did not bind. The limit of detection is at least 0.10 microg/g. Percentage recovery for the entire assay range averages 90% with an average relative standard deviation of 8.3%. Naturally contaminated samples showed comparable precision. Column capacity was determined to be 3.3 microg. The assay showed a high degree of linearity (r2=0.999) and an optimum assay range of 0.10 to 10.0 microg/g. Comparative analysis of 28 naturally or artificially contaminated wheat samples using DONtest-HPLC and the GC-ECD method of Tacke and Casper showed that DONtest-HPLC is a statistically significant predictor of the GC-ECD method (r2=0.982).  相似文献   

13.
A sensitive, precise and accurate method has been developed for the simultaneous determination of T-2 and HT-2 toxins in cereal grains at ppb levels using high-performance liquid chromatography (HPLC) with fluorescence detection and 1-antroylnitrile (1-AN) as labeling reagent after immunoaffinity clean-up. Cereal samples were extracted with methanol/water (90:10, v/v), and the extracts were cleaned-up through commercially available immunoaffinity columns containing monoclonal anti-T-2 antibodies (T-2 test HPLC, Vicam). T-2 and HT-2 toxins were quantified by reversed-phase HPLC with fluorometric detection (excitation wavelength 381 nm, emission wavelength 470 nm) after derivatization with 1-AN. The monoclonal antibody showed 100% cross-reactivity with both T-2 and HT-2 toxin, and the immunoaffinity column clean-up was effective up to 1.4 microg of both toxins. The method was successfully applied to the analysis of T-2 and HT-2 toxins in wheat, maize and barley. Recoveries from spiked samples with toxin levels from 25 to 500 microg/kg ranged from 70% to 100%, with relative standard deviation generally lower than 8%. The limit of detection of the method was 5 microg/kg for T-2 toxin and 3 microg/kg for HT-2 toxin, based on a signal-to-noise ratio 3:1. HT-2 toxin was detected in ten naturally contaminated wheat samples out of 14 samples analyzed, with toxin levels ranging from 10 to 71 microg/kg; three of them contained also T-2 toxin up to 12 microg/kg.  相似文献   

14.
Three long and 1 short reversed-phase C18 columns were compared for separation of deoxynivalenol (DON) in extracts of naturally contaminated wheat samples using liquid chromatography with ultraviolet detection and liquid chromatography/mass spectrometry (LC/MS). Among the 3 long columns used, a Symmetry C18 column with an isocratic solvent mixture of water-acetonitrile-methanol (90 + 5 + 5, v/v/v) gave the best separation for DON without interferences from other compounds in the wheat extracts. The Symmetry short (75 mm) column was comparable with the long column (250 mm) in resolving DON but significantly reduced retention time (i.e., 5.8 versus 16.3 min). Increasing the column temperature from 25 to 45 degrees C resulted in a further reduction in retention time. Identity of DON in the wheat extracts and standard solutions was confirmed by LC/MS in the positive ion mode, whereby DON appeared with an (M+1)+ ion at a mass-to-charge ratio of 297 plus fragment ions associated with loss of water and/or a 30 atomic mass unit (amu) CH2O fragment. The Symmetry short column was also capable of separating a mixture of the mycotoxins DON, 15-acetyl-DON, nivalenol, and zearalenone by use of a combination of an isocratic and gradient solvent system. The overall method showed high precision, exhibiting a relative standard deviation of 4.8%, limit of detection of 50 ng/g, and limit of quantitation of 165 ng/g. It was significantly correlated with enzyme-linked immunosorbent assay analysis, indicating its appropriateness for safety and quality assurance of wheat and related grains.  相似文献   

15.
A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol-water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.  相似文献   

16.
17.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 and total aflatoxins at European regulatory limits. The test portion is extracted with methanol-water (8 + 2) for dried figs and paprika, and with methanol-water (8 + 2) plus hexane (or cyclohexane) for peanut butter and pistachios. The sample extract is filtered, diluted with phosphate buffer saline, and applied to an immunoaffinity column. The column is washed with water and the aflatoxins are eluted with methanol. Aflatoxins are quantitated by reversed-phase LC with post-column derivatization (PCD) involving bromination. PCD is achieved with either an electrochemical cell (Kobra cell) and addition of bromide to the mobile phase or pyridinium hydrobromide perbromide. Determination is by fluorescence. Peanut butter, pistachio paste, dried fig paste, and paprika powder samples, both naturally contaminated with aflatoxins and containing added aflatoxins, were sent to 16 collaborators in 16 European countries. Test portions of samples were spiked at levels of 2.4 and 9.6 ng/g for total aflatoxins which included 1.0 and 4.0 ng/g aflatoxin B1, respectively. Recoveries for total aflatoxins ranged from 71 to 92% with corresponding recoveries for aflatoxin B1 of 82 to 109%. Based on results for spiked samples (blind duplicates at 2 levels) as well as naturally contaminated samples (blind duplicates at 4 levels, including blank), the relative standard deviation for repeatability ranged from 4.6 to 23.3% for total aflatoxins and from 3.1 to 20.0% for aflatoxin B1. The relative standard deviation for reproducibility ranged from 14.1 to 34.2% for total aflatoxins, and from 9.1 to 32.2% for aflatoxin B1. The method showed acceptable within-laboratory and between-laboratory precision for all 4 matrixes, as evidenced by HORRAT values <1, at the low levels of determination for both total aflatoxins and aflatoxin B1.  相似文献   

18.
The accuracy, repeatability, and reproducibility characteristics of a method using multitoxin immunoaffinity column cleanup with liquid chromatography (LC) for determination of aflatoxins (AF; sum of aflatoxins B1, B2, G1, and G2) and ochratoxin A (OTA) in powdered ginseng and ginger have been established in a collaborative study involving 13 laboratories from 7 countries. Blind duplicate samples of blank, spiked (AF and OTA added) at levels ranging from 0.25 to 16.0 microg/kg for AF and 0.25 to 8.0 microg/kg for OTA were analyzed. A naturally contaminated powdered ginger sample was also included. Test samples were extracted with methanol and 0.5% aqueous sodium hydrogen carbonate solution (700 + 300, v/v). The extract was centrifuged, diluted with phosphate buffer (PB), filtered, and applied to an immunoaffinity column containing antibodies specific for AF and OTA. After washing the column with water, the toxins were eluted from the column with methanol, and quantified by high-performance LC with fluorescence detection. Average recoveries of AF from ginseng and ginger ranged from 70 to 87% (at spiking levels ranging from 2 to 16 microg/kg), and of OTA, from 86 to 113% (at spiking levels ranging from 1 to 8 microg/kg). Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 2.6 to 8.3% for AF, and from 2.5 to 10.7% for OTA. Relative standard deviations for between-laboratory reproducibility (RSDR) ranged from 5.7 to 28.6% for AF, and from 5.5 to 10.7% for OTA. HorRat values were < or = 2 for the multi-analytes in the 2 matrixes.  相似文献   

19.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol-water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSD(R)) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.  相似文献   

20.
The accuracy, repeatability, and reproducibility characteristics of a method for measuring levels of zearalenone (ZON) in botanical root products, soybeans, grains, and grain products were determined by an AOAC single-laboratory validation procedure. Replicates of 10 test portions of each powdered root product (black cohosh, ginger, ginseng), brown rice flour, brown rice grain, oat flour, rice bran, soybeans, and wheat flour at each spiking level (ZON at 0, 50, 100, and 200 microg/kg) were analyzed on 3 separate days. Test samples were extracted with methanol-water (75 + 25, v/v). The extracts were centrifuged or filtered, diluted with phosphate-buffered saline (PBS) containing 0.5% Tween 20, and filtered; the filtrates were applied to an immunoaffinity column containing antibodies specific for ZON. After the column was washed with methanol-PBS (15 + 85, v/v) containing 0.5% Tween 20 and then with water, the toxin was eluted from the column with methanol, and the eluate was diluted with water. The eluate containing the toxin was then subjected to RPLC with fluorescence detection. All commodities that were found to contain ZON at < 10 microg/kg were used for the recovery study. The average within-day and between-days recoveries of ZON added at levels of 50-200 microg/kg ranged from 82 to 88% and from 81 to 84%, respectively, for all test commodities. The total average of within- and between-day SD and RSDr values for all test commodities ranged from 2.5 to 7.3 microg/kg and from 4.6 to 6.2%, respectively. HorRat values were <1.3 for all matrixes examined. The tested method was found to be acceptable for the matrixes examined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏