首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Lin YC  Li M  Wu CC 《Lab on a chip》2004,4(2):104-108
Simulation and experimental demonstration of the in vitro gene delivery enhancement using electrostatic forces and electroporation (EP) microchips were conducted. Electroporation is a technique with which DNA molecules can be delivered into cells using electric field pulses. This study demonstrates that plasmid DNA can be attracted to the cell surfaces at the specific regions using an electrostatic force. Therefore, the DNA concentration on the cell surface is dramatically increased, which highly enhances the gene transfection efficiency compared to that without an attracting-electric field. The electrostatic force can be designed into specific regions, where the DNA plasmids are attracted to, to provide the region-targeting function. In this micro-device, the top electrode and the interdigitated electrodes provided the DNA attracting-electric field, and the interdigitated electrodes provided adequate electric fields for the electroporation process on the chip surface. Using the EP microchip, cells could be manipulated in situ without detachment if adherent cells were used for electroporation. Five different cells of two different types, primary cell and cell line, were successfully transfected under multi-pulse or single pulse electric field stimulation without applying an attracting-electric field. This study simulated and analyzed the electric field distributions at the DNA attracting and electroporation processes, and successfully demonstrated that the electrostatic force attracted DNA plasmids to specific regions and highly enhanced the gene delivery. In summary, this EP microchip should provide many potential applications for gene therapy.  相似文献   

2.
Tsai SL  Hong JL  Chen MK  Jang LS 《Electrophoresis》2011,32(11):1337-1347
This work presents a microfluidic system that can transport, concentrate, and capture particles in a controllable droplet. Dielectrophoresis (DEP), a phenomenon in which a force is exerted on a dielectric particle when it is subjected to a non-uniform electric field, is used to manipulate particles. Liquid dielectrophoresis (LDEP), a phenomenon in which a liquid moves toward regions of high electric field strength under a non-uniform electric field, is used to manipulate the fluid. In this study, a mechanism of droplet creation presented in a previous work that uses DEP and LDEP is improved. A driving electrode with a DEP gap is used to prevent beads from getting stuck at the interface between air and liquid, which is actuated with an AC signal of 200 V(pp) at a frequency of 100 kHz. DEP theory is used to calculate the DEP force in the liquid, and LDEP theory is used to analyze the influence of the DEP gap. The increment of the actuation voltage due to the electrode with a DEP gap is calculated. A set of microwell electrodes is used to capture a bead using DEP force, which is actuated with an AC signal of 20 V(pp) at a frequency of 5 MHz. A simulation is carried out to investigate the dimensions of the DEP gap and microwell electrodes. Experiments are performed to demonstrate the creation of a 100-nL droplet and the capture of individual 10-μm polystyrene latex beads in the droplet.  相似文献   

3.
阵列叉指式芯片研究细胞介电电泳富集过程   总被引:2,自引:0,他引:2  
采用阵列叉指电极介电电泳(Dielectrophoresis,DEP)芯片,构建了集成DEP芯片分析和操控系统,应用Coventorware有限元分析软件模拟分析了芯片表面的电场分布情况;以红细胞和结肠癌细胞样品为分析对象,实现了两种细胞样品在芯片上的正负介电电泳定位富集.实验发现,交流信号幅值Vp-p是决定DEP富集效率的主因,交流信号频率f和缓冲溶液是改变细胞介电电泳类型的参量;在0.9% NaCl中,施加频率为10和3 MHz、电压5 V的交流频率,结肠癌细胞的正介电电泳(Positive-dielectrophoresis, pDEP)和负介电电泳(Nagetive-dielectrophoresis, nDEP)富集效率分别为87.2%和84.8%.  相似文献   

4.
Dielectrophoresis in microfluidics technology   总被引:1,自引:0,他引:1  
Cetin B  Li D 《Electrophoresis》2011,32(18):2410-2427
Dielectrophoresis (DEP) is the movement of a particle in a non-uniform electric field due to the interaction of the particle's dipole and spatial gradient of the electric field. DEP is a subtle solution to manipulate particles and cells at microscale due to its favorable scaling for the reduced size of the system. DEP has been utilized for many applications in microfluidic systems. In this review, a detailed analysis of the modeling of DEP-based manipulation of the particles is provided, and the recent applications regarding the particle manipulation in microfluidic systems (mainly the published works between 2007 and 2010) are presented.  相似文献   

5.
The capture of circulating tumor cells (CTCs) from cancer patient blood enables early clinical assessment as well as genetic and pharmacological evaluation of cancer and metastasis. Although there have been many microfluidic immunocapture and electrokinetic techniques developed for isolating rare cancer cells, these techniques are often limited by a capture performance tradeoff between high efficiency and high purity. We present the characterization of shear‐dependent cancer cell capture in a novel hybrid DEP–immunocapture system consisting of interdigitated electrodes fabricated in a Hele‐Shaw flow cell that was functionalized with a monoclonal antibody, J591, which is highly specific to prostate‐specific membrane antigen expressing prostate cancer cells. We measured the positive and negative DEP response of a prostate cancer cell line, LNCaP, as a function of applied electric field frequency, and showed that DEP can control capture performance by promoting or preventing cell interactions with immunocapture surfaces, depending on the sign and magnitude of the applied DEP force, as well as on the local shear stress experienced by cells flowing in the device. This work demonstrates that DEP and immunocapture techniques can work synergistically to improve cell capture performance, and it will aid in the design of future hybrid DEP–immunocapture systems for high‐efficiency CTC capture with enhanced purity.  相似文献   

6.
Gagnon ZR 《Electrophoresis》2011,32(18):2466-2487
Over the past decade, dielectrophoresis (DEP) has evolved into a powerful, robust and flexible method for cellular characterization, manipulation, separation and cell patterning. It is a field with widely varying disciplines, as it is quite common to see DEP integrated with a host of applications including microfluidics, impedance spectroscopy, tissue engineering, real-time PCR, immunoassays, stem-cell characterization, gene transfection and electroporation, just to name a few. The field is finally at the point where analytical and numerical polarization models can be used to adequately describe and characterize the dielectrophoretic behavior of cells, and there is ever increasing evidence demonstrating that electric fields can safely be used to manipulate cells without harm. As such, DEP is slowly making its way into the biological sciences. Today, DEP is being used to manipulate individual cells to specific regions of space for single-cell assays. DEP is able to separate rare cells from a heterogeneous cell suspension, where isolated cells can then be characterized and dynamically studied using nothing more than electric fields. However, there is need for a critical report to integrate the many new features of DEP for cellular applications. Here, a review of the basic theory and current applications of DEP, specifically for cells, is presented.  相似文献   

7.
Dielectrophoresis (DEP) and flow cytometry are powerful technologies and widely applied in microfluidic systems for handling and measuring cells and particles. Here, we present a novel microchip with a DEP selective filter integrated with two microchip flow cytometers (FCs) for on-line monitoring of cell sorting processes. On the microchip, the DEP filter is integrated in a microfluidic channel network to sort yeast cells by positive DEP. The two FCs detection windows are set upstream and downstream of the DEP filter. When a cell passes through the detection windows, the light scattered by the cell is measured by integrated polymer optical elements (waveguide, lens, and fiber coupler). By comparing the cell counting rates measured by the two FCs, the collection efficiency of the DEP filter can be determined. The chips were used for quantitative determination of the effect of flow rate, applied voltage, conductivity of the sample, and frequency of the electric field on the sorting efficiency. A theoretical model for the capture efficiency was developed and a reasonable agreement with the experimental results observed. Viable and non-viable yeast cells showed different frequency dependencies and were sorted with high efficiency. At 2 MHz, more than 90% of the viable and less than 10% of the non-viable cells were captured on the DEP filter. The presented approach provides quantitative real-time data for sorting a large number of cells and will allow optimization of the conditions for, e.g., collecting cancer cells on a DEP filter while normal cells pass through the system. Furthermore, the microstructure is simple to fabricate and can easily be integrated with other microstructures for lab-on-a-chip applications.  相似文献   

8.
Dielectrophoresis (DEP) for cell manipulation has focused, for the most part, on approaches for separation/enrichment of cells of interest. Advancements in cell positioning and immobilization onto substrates for cell culture, either as single cells or as cell aggregates, has benefited from the intensified research efforts in DEP (electrokinetic) manipulation. However, there has yet to be a DEP approach that provides the conditions for cell manipulation while promoting cell function processes such as cell differentiation. Here we present the first demonstration of a system that combines DEP with a hybrid cell adhesive material (hCAM) to allow for cell entrapment and cell function, as demonstrated by cell differentiation into neuronlike cells (NLCs). The hCAM, comprised of polyelectrolytes and fibronectin, was engineered to function as an instantaneous cell adhesive surface after DEP manipulation and to support long-term cell function (cell proliferation, induction, and differentiation). Pluripotent P19 mouse embryonal carcinoma cells flowing within a microchannel were attracted to the DEP electrode surface and remained adhered onto the hCAM coating under a fluid flow field after the DEP forces were removed. Cells remained viable after DEP manipulation for up to 8 d, during which time the P19 cells were induced to differentiate into NLCs. This approach could have further applications in areas such as cell-cell communication, three-dimensional cell aggregates to create cell microenvironments, and cell cocultures.  相似文献   

9.
The spatial and temporal control of biological species is essential in complex microfluidic biosystems. In addition, if the biological species is a cell, microfluidic handling must ensure that the cell's metabolic viability is maintained. The use of DEP for cell manipulation in microfluidics has many advantages because it is remote and fast, and the voltages required for cell trapping scale well with miniaturization. In this paper, the conditions for bacterial cell (Escherichia coli) trapping using a quadrupole electrode configuration in a PDMS microfluidic channel were developed both for stagnant and for in‐flow fluidic situations. The effect of the electrical conductivity of the fluid, the applied electric field and frequency, and the fluid‐flow velocity were studied. A dynamic exchange between captured and free‐flowing cells during DEP trapping was demonstrated. The metabolic activity of trapped cells was confirmed by using E. coli cells genetically engineered to express green fluorescent protein under the control of an inducible promoter. Noninduced cells trapped by negative DEP and positive DEP were able to express green fluorescent protein minutes after the inducer was inserted in the microchannel system immediately after DEP trapping. Longer times of trapping prior to exposure to the inducer indicated first a degradation of the cell metabolic activity and finally cell death.  相似文献   

10.
We describe the development and testing of a setup that allows for DEP field‐flow fractionation (DEP‐FFF) of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells based on their different polarizabilities. We first optimized the channel and electrode dimensions, flow rate, and electric field parameters for efficient DEP‐FFF separation of moderately heat‐treated CHO cells (50°C for 15 min) from untreated ones, with the former used as a uniform and stable model of electroporated cells. We then used CHO cells exposed to electric field pulses with amplitudes from 1200 to 2800 V/cm, yielding six groups containing various fractions of nonporated, reversibly porated, and irreversibly porated cells, testing their fractionation in the chamber. DEP‐FFF at 65 kHz resulted in distinctive flow rates for nonporated and each of the porated cell groups. At lower frequencies, the efficiency of fractionation deteriorated, while at higher frequencies the separation of individual elution profiles was further improved, but at the cost of cell flow rate slowdown in all the cell groups, implying undesired transition from negative into positive DEP, where the cells are pulled toward the electrodes. Our results demonstrate that fractionation of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells is feasible at a properly selected frequency.  相似文献   

11.
Dielectrophoretic (DEP) force is exerted when a neutral particle is polarized in a non-uniform electric field, and depends on the dielectric properties of the particle and the suspending medium. The integration of DEP and microfluidic systems offers numerous applications for the separation, trapping, assembling, transportation, and characterization of micro/nano particles. This article reviews the applications of DEP forces in microfluidic systems. It presents the theory of dielectrophoresis, different configurations, and the applications of such systems for particle manipulation and device fabrication.  相似文献   

12.
Under the influence of electric pulses cells undergo membrane electroporation (EP), which results in increased permeability of the membrane to exogenous compounds. EP is applied in oncology as a method to enhance delivery of anticancer drugs. For that reason it was essential to combine photodynamic tumor therapy (PDT)--the cancer treatment method based on the use of photosensitizers that localize selectively in malignant tumors and become cytotoxic when exposed to light, and EP, with the aim to enhance the delivery of photosensitizers into the tumor and therefore to increase the efficacy of PDT. Thus, the aim of study was to evaluate the cytotoxic effect of PDT in combination with EP. A Chinese hamster lung fibroblast cell line (DC-3F) was used. The cells were affected by photosensitizers chlorin e(6) (C e(6)) at the dose of 10 mug/ml and aluminium phthalocyanine tetrasulfonate (AlPcS4) at the dose of 50 microg/ml. Immediately after adding of photosensitizers the cells were electroporated with 8 electric pulses at 1200 V/cm intensity, 0.1 ms duration, 1 Hz frequency. Then, after 20 min of incubation the cells were irradiated using a light source--a visible light passing through a filter (KC 14, emitted light from 660 nm). The fluence rate at the level of the cells was 3 mW/m(2). Cytotoxic effect on cells viability was evaluated using MTT assay. Our in vitro data showed that the cytotoxicity of PDT in combination with EP increases fourfold on the average. Based on the results we suggest that EP could enhance the effect of PDT.  相似文献   

13.
Urdaneta M  Smela E 《Lab on a chip》2008,8(4):550-556
This paper presents a method of using multiple frequencies to counteract electric field distortions that interfere with the dielectrophoretic (DEP) manipulation of particles or cells. To demonstrate the technique, simulations were performed for a scenario in which cells were to be loaded into a cage whose walls created parasitic trapping sites that prevented cells from entering it. By employing negative DEP on one electrode in conjunction with positive DEP on another, these traps could be almost completely cancelled. The model predictions were validated experimentally: multiple frequency DEP was used to load many cells into a cage in a matter of seconds in fluid flows of up to 300 microm s(-1), which could not be done with single frequency DEP. Actively cancelling field distortions permits the presence of features that would otherwise be prohibited near regions of dielectrophoretic manipulation, significantly expanding the environments in which dielectrophoresis can be used.  相似文献   

14.
This paper presents the development and experimental verification of a DEP fluidic system capable of fractionation of intact biological cells in suspension into purer subpopulations. This was accomplished by employing a specially shaped nonuniform electric field, synthesized by microfabricated planar microelectrode arrays, housed on an insulating glass substrate. To improve the efficiency of cell sorting, the microelectrodes are individually biased by a variable frequency alternating current (ac) voltage source, which allows us to exploit both positive and negative dielectrophoresis (DEP) to affect cell separation. Furthermore, through suitable establishment of a cell stream supported by sheath flow, such fractionation is achieved in a continuous fashion. The proposed DEP fluidic fractionation may be configured to operate in three (3) different modes. In this work, however, a detailed account is only presented for one mode of operation. The simulation of the electric field and force profiles, together with the experimental results obtained on model cells (plant protoplasts), confirm our theoretical predictions and furthermore demonstrate improvements in both separation efficiency and throughput over a wide range of frequencies (10 Hz to 5 kHz).  相似文献   

15.
A new dielectrophoretic particle separation method is demonstrated and examined in the following experimental study. Current electrodeless dielectrophoretic (DEP) separation techniques utilize insulating solid obstacles in a DC or low-frequency AC field, while this novel method employs an oil droplet acting as an insulating hurdle between two electrodes. When particles move in a non-uniform DC field locally formed by the droplet, they are exposed to a negative DEP force linearly dependent on their volume, which allows the particle separation by size. Since the size of the droplet can be dynamically changed, the electric field gradient, and hence DEP force, becomes easily controllable and adjustable to various separation parameters. By adjusting the droplet size, particles of three different diameter sizes, 1 microm, 5.7 microm and 15.7 microm, were successfully separated in a PDMS microfluidic chip, under applied field strength in the range from 80 V cm-1 to 240 V cm-1. A very effective separation was realized at the low field strength, since the electric field gradient was proved to be a more significant parameter for particle discrimination than the applied voltage. By utilizing low strength fields and adaptable field gradient, this method can also be applied to the separation of biological samples that are generally very sensitive to high electric potential.  相似文献   

16.
Fan SK  Huang PW  Wang TT  Peng YH 《Lab on a chip》2008,8(8):1325-1331
Two important electric forces, dielectrophoresis (DEP) and electrowetting-on-dielectric (EWOD), are demonstrated by dielectric-coated electrodes on a single chip to manipulate objects on different scales, which results in a dielectrophoretic concentrator in an EWOD-actuated droplet. By applying appropriate electric signals with different frequencies on identical electrodes, EWOD and DEP can be selectively generated on the proposed chip. At low frequencies, the applied voltage is consumed mostly in the dielectric layer and causes EWOD to pump liquid droplets on the millimetre scale. However, high frequency signals establish electric fields in the liquid and generate DEP forces to actuate cells or particles on the micrometre scale inside the droplet. For better performance of EWOD and DEP, square and strip electrodes are designed, respectively. Mammalian cells (Neuro-2a) and polystyrene beads are successfully actuated by a 2 MHz signal in a droplet by positive DEP and negative DEP, respectively. Droplet splitting is achieved by EWOD with a 1 kHz signal after moving cells or beads to one side of the droplet. Cell concentration, measured by a cell count chamber before and after experiments, increases 1.6 times from 8.6 x 10(5) cells ml(-1) to 1.4 x 10(6) cells ml(-1) with a single cycle of positive DEP attraction. By comparing the cutoff frequency of the voltage drop in the dielectric layer and the cross-over frequency of Re(fCM) of the suspended particles, we can estimate the frequency-modulated behaviors between EWOD, positive DEP, and negative DEP. A proposed weighted Re(fCM) facilitates analysis of the DEP phenomenon on dielectric-coated electrodes.  相似文献   

17.
This article describes a dielectrophoresis (DEP)-based simulation and experimental study of human epidermal keratinocyte (HEK) cells for wounded skin cell migration toward rapid epithelialization. MyDEP is a standalone software designed specifically to study dielectric particles and cell response to an alternating current (AC) electric field. This method demonstrated that negative dielectrophoresis (NDEP) occurs in HEK cells at a wide frequency range in highly conductive medium. The finite element method was used to characterize particle trajectory based on DEP and drag force. The performance of the system was assessed using HEK cells in a highly conductive EpiLife suspending medium. The DEP experiment was performed by applying sinusoidal wave AC potential at the peak-to-peak voltage of 10 V in a tapered aluminum microelectrode array from 100 kHz to 1 MHz. We experimentally observed the occurrence of NDEP, which attracted HEK cells toward the local electric field minima in the region of interest. The DIPP-MotionV software was used to track cell migration in the prerecorded video via an automatic marker and estimate the average speed and acceleration of the cells. The results showed that HEK cell migration was accomplished approximately at 6.43 μm/s at 100 kHz with 10 V, and FDEP caused the cells to migrate and align at the target position, which resulted in faster wound closures because of the application of an electric field frequency to HEK cells in random locations.  相似文献   

18.
In this study, a new micro electroporation (EP) cell chip with three-dimensional (3D) electrodes was fabricated by means of MEMS technology, and tested on cervical cancer (HeLa) cells. Extensive statistical data of the threshold electric field and pulse duration were determined to construct an EP "phase diagram", which delineates the boundaries for 1) effective EP of five different size molecules and 2) electric cell lysis at the single-cell level. In addition, these boundary curves (i.e., electric field versus pulse duration) were fitted successfully with an exponential function with three constants. We found that, when the molecular size increases, the corresponding electroporation boundary becomes closer to the electric cell lysis boundary. Based on more than 2000 single-cell measurements on five different size molecules, the critical size of molecule was found to be approximately 40 kDa. Comparing to the traditional instrument, MEMS-based micro electroporation chip can greatly shorten the experimental time.  相似文献   

19.
This paper develops a numerical simulation model to research the deformable particle-particle interactions caused by dielectrophoresis (DEP) under AC electric fields. The DEP force is calculated by using Maxwell stress tensor method, and the hydrodynamic force is obtained by calculating the hydrodynamic stress tensor. Simulation results show that the DEP interactive motion will facilitate the particles forming particle chains that are parallel to the electric field, and the particles with low shear modulus present a lower x-component velocity. Also, the electric field intensity and particles radius have some effects on the DEP motions, and for different particles, smaller particles with larger electric field intensity easily reach a larger velocity. The numerical research may provide universal guidance for biological cells manipulation and assembly.  相似文献   

20.
The design and fabrication of a self‐digitization dielectrophoretic (SD‐DEP) chip with simple components for single‐cell manipulation and downstream nucleic acid analysis is presented. The device employed the traditional DEP and insulator DEP to create the local electric field that is tailored to approximately the size of single cells, enabling highly efficient single‐cell capture. The multistep procedures of cell manipulation, compartmentalization, lysis, and analysis were performed in the integrated microdevice, consuming minimal reagents, minimizing contamination, decreasing lysate dilution, and increasing assay sensitivity. The platform developed here could be a promising and powerful tool in single‐cell research for precise medicine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号