首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.

Purpose

The aim of this study was to determine the adequate MR sequence for the lesion conspicuity of hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide (SPIO)-enhanced MRI.

Materials and Methods

SPIO-enhanced MRI was performed using a 1.5-T system. Among 25 patients with hypovascular hepatocellular nodules on contrast-enhanced dynamic CT (no early enhancement at arterial phase and hypoattenuation at equilibrium phase), 39 lesions with increased iron uptake on SPIO-enhanced MRI were evaluated. SPIO-enhanced MRI included (1) T1-weighted in-phase gradient recalled echo (GRE) images, (2) T2-weighted fast spin echo (FSE) images, (3) T2*-weighted GRE with moderate TE (7 ms) and (4) long TE (12 ms). The lesion-to-liver contrast-to-noise ratios of the hepatocellular nodule and the signal-to-noise ratio (SNR) of the hepatic parenchyma were calculated by one radiologist for a quantitative assessment. MR images were reviewed retrospectively by two independent radiologists to compare the subjective lesion conspicuity in each image set based on a four-point rating scale.

Result

The mean lesion-to-liver contrast-to-noise ratios with T2*-weighted GRE with moderate TE (7 ms) was highest (5.79±3.71) and was significantly higher than those with T1-weighted, in-phase images (3.79±3.23, P<.01), T2-weighted images (2.72±1.52, P<.001) and T2*-weighted GRE with long TE (12 ms) (3.93±2.69, P<.05). The subjective rating of lesion conspicuity was best on the T2*-weighted GRE with moderate TE (7 ms), followed by that on the T2*-weighted GRE with moderate TE (7 ms; P<.05).

Conclusion

T2*-weighted GRE sequence with moderate TE (7 ms) showed high lesion-to-liver contrast-to-noise ratios in hepatocellular lesions with increased iron uptake on SPIO-enhanced MRI, indicating better lesion conspicuity of hypointense hepatocellular nodules in cirrhosis or chronic hepatitis.  相似文献   

2.
Non-human primates (NHPs) are vital models for neuroscience research. These animals have been widely used in behavioral, electrophysiological, molecular, and more recently, multimodal neuroimaging and neuro-engineering studies. Several RF coil arrays have been designed for functional, high-resolution brain magnetic resonance imaging (MRI), but few have been designed to accommodate multimodal devices. In the present study, a 16-channel array coil was constructed for brain imaging of macaques at 3 Tesla (3 T). To construct this coil, a close-fitting helmet-shaped form was designed to host 16 coil loops for whole-brain coverage. This assembly is mountable onto stereotaxic head frame bars, and the coil functions while the monkey is in the sphinx position with a clear line of vision of stimuli presented from outside of the MRI system. In addition, 4 openings were allocated in the coil housing, allowing multimodal devices to directly access visual cortical regions such as V1-V4 and MT. Coil performance was evaluated in an anesthetized macaque by quantifying and comparing signal-to-noise ratios (SNRs), noise correlations, and g-factor maps to a vendor-supplied human pediatric coil frequently used for NHP MRI. The result from in vivo experiments showed that the NHP coil was well-decoupled, had higher SNRs in cortical regions, and improved data acquisition acceleration capability compared with a vendor-supplied human pediatric coil that has been frequently used in macaque MRI studies. Furthermore, whole-brain anatomic imaging, diffusion tensor imaging and functional brain imaging have also been conducted: the details of brain anatomical structure, such as cerebellum and brainstem, can be clearly visualized in T2-SPACE images; b0 SNR calculated from b0 maps was higher than the human pediatric coil in all regions of interest (ROIs); the time-course SNR (tSNR) map calculated for GRE-EPI images demonstrates that the presented coil can be used for high-resolution functional imaging at 3 T.  相似文献   

3.
Magnetic Resonance Imaging (MRI) affords a considerable improvement in image contrast over other methods by virtue of the intrinsic NMR parameters spin density, T1, and T2. However, the clinical utility of routine quantification of these parameters is currently unknown. Calculated T2 images might afford additional disease specific information provided the calculation algorithm generates accurate T2 values. In this study, calculated T2 images of a MnCl2 phantom (spanning a T2 range of interest of 45.7 ms to 346.6 ms at 6 MHz) were generated utilizing a variety of calculation algorithms based upon a data set of 32 sequential spin-echo (SE) images. In general, when utilizing only the earliest sequential SE after the 90 degree pulse for the T2 calculation, the greater the number of SE used in the calculation algorithm, regardless of how they were averaged, the more accurate and less noisy was the calculated image. When only limited numbers of SE were used in the calculation algorithm, accuracy and noise varied with the choice of TE suggesting that there may be optimal timings for TE for a particular T2 range of interest. Forty-two calculated T2 head images of normal subjects, based upon data sets of 16 sequential SE, were evaluated for the T2 values of normal brain. These were compared to T2 images calculated via 7 different algorithms based upon 16 SE data sets from two patients with CNS pathology. An optimal algorithm was identified in which 16 SE Carr-Purcell-Meiboom-Gill (CPMG) were averaged into two images for the T2 calculation. With this algorithm, calculated images could be generated efficiently which were accurate and relatively noise free. The availability of such images maximized whatever disease specificity, and thus clinical utility, T2 information affords.  相似文献   

4.
The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present a technique based on the use of echo shifting (ES) in conjunction with a multislice (MS) echo planar imaging (EPI) readout, which allows T2*-weighted images to be generated with a repetition time per slice that is less than the echo time (TE). Using this ES-MS-EPI approach, it is shown that images with a TE of 40 ms can be acquired with an acquisition time per slice of only 27 ms. The utility of the MS-ES-EPI sequence is demonstrated in a visual-motor, event-related fMRI study in which nine-slice image volumes are acquired continuously at a rate of 4.1 Hz. The sequence is shown to produce reliable activation associated with both visual stimuli and motor actions.  相似文献   

5.
In magnetic resonance imaging (MRI), T(2)(*)-weighted contrast is significantly enhanced by extremely high magnetic field strength, offering broad potential applications. However, the T(2)(*)-weighted image contrast distortion and signal loss artifact arising from discontinuities of magnetic susceptibility within and around the sample are also increased, limiting utilization of high field systems for T(2)(*)-weighted contrast applications. Due to the B(0) dependence of the contrast distortions and signal losses, and the heterogeneity of magnetic susceptibility in biological samples, magnetic susceptibility artifacts worsen dramatically for in vivo microimaging at higher fields. Practical applications of T(2)(*)-sensitive techniques enhanced by higher magnetic fields are therefore challenged. This report shows that magnetic susceptibility artifacts dominate T(2)(*)-weighted image contrast at 14 T, and demonstrates that the GESEPI (gradient echo slice excitation profile imaging) technique effectively reduces or eliminates these artifacts at long TE in the highest field (14 T) currently available for (1)H imaging.  相似文献   

6.
In this study, we combined the advantages of a fast multi-slice spiral imaging approach with a multiple gradient-echo sampling scheme at high magnetic field strength to improve quantification of BOLD and inflow effects and to estimate T2* relaxation times in functional brain imaging. Eight echoes are collected with echo time (TE) ranging from 5 to 180 ms. Acquisition time per slice and echo time is 25 ms for a nominal resolution of 4 x 4 x 4 mm3. Evaluation of parameter images during rest and stimulation yields no significant activation on the inflow sensitive spin-density images (rho or I0-maps) whereas clear activation patterns in primary human motor cortex (M1) and supplementary motor area (SMA) are detected on BOLD sensitive T2*-maps. The calculation of relaxation times and rates of the activated areas over all subjects yields an average T2* +/- standard deviation (SD) of 46.1+/-4.5 ms (R2* of 21.8+/-2.2 s(-1)) and an average increase (deltaT2* +/- SD) of 0.93+/-0.47 ms (deltaR2* of -0.4+/-0.14 s(-1)). Our findings demonstrate the usefulness of a multiple gradient echo data acquisition approach in separating various vascular contributions to brain activation in fMRI.  相似文献   

7.
The authors report the technical feasibility of measuring event-related changes in blood oxygenation for studying brain function in humans at high temporal resolution. Measurements were performed on a conventional wholebody 1.5 T clinical scanner with a nonactive-shielded standard gradient system of 1 ms rise time for a maximum gradient strength of 10 mT/m. The radiofrequency (RF) transmitting and receiving MR unit consists of a commercially available circular polarized head coil. Magnet shimming with all first-order coils was performed to the volunteer's head resulting in a magnetic field homogeneity of about 0.1–0.2 ppm. The measuring sequence used was a modified 3D, first-order flow rephased, FLASH sequence with reduced bandwidth = 40 Hz/pixel, TR = 80 ms, TE = 56 ms, flip angle = 40–50°, matrix = 64 × 128, field-of-view = 200–250 mm2, slice thickness = 4 mm, NEX = 1, 128 partitions, and a total single scan time of about 10 min. In this sequence the 3D gradient table was removed and the 3D partition-loop acts as a time-loop for sequential measurement of 128 or 32 consecutive images at the same slice position. This means that event-related functional MRI could be performed with an interscan delay of 80 ms for a series of 128 sequential images or with an interscan delay of 320 ms for a simultaneous measurement of four slices with a series of 32 sequential images for each slice. We used a TTL signal given by the gradient board at the beginning of every line-loop in the measuring sequence and a self-made “TTL-Divider-Box” for the event triggering. This box was used to count and scale down the TTL signals by a factor of 128 and to trigger after every 128th TTL signal a single white flash-light, which was seen by the volunteer in the dark room of the scanner with a period of 10.24 s. As a consequence, the resulting event-related scan data coincide at each line of the series of 128 sequential images, which were repeated in 128 × 80 ms or 32 × 320 ms for the single- or four-slice experiment, respectively. Visual cortex response magnitude measured was about 5–7% with an approximate Gaussian shape and a rise time from stimulus onset to maximum of about 3–4 s, and a fall time to the baseline of about 5–6 s after end of stimulus. The reported data demonstrate the feasibility of functional MRI studies at high temporal resolution (up to 80 ms) using conventional MR equipment and measuring sequence.  相似文献   

8.
Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor in 80% of the MRI examinations but only in 62% of the CT scans. MRI and CT were equally effective in determining the presence or absence of bony invasion. The MRI images of all the tumors showed increased signal intensity relative to normal muscle when spin-echo (SE) sulse sequences with long repeat times were used (SE: echo time [TE], 60 ms; repetition time [TR], 2,000 ms). When T1 weighted pulse sequences were used (SE: TE, 30 ms; TR, 500 ms or inversion recovery: inversion time, 500 ms; TE, 40 ms; TR, 2,000 ms) the malignant tumors showed decreased signal intensity compared to normal muscle. Only lipomas showed high signal intensity on both T1 and T2 weighted pulse sequences.  相似文献   

9.
Previous studies have shown that T2(dagger)-weighted magnetic resonance images acquired using localization by adiabatic selective refocusing (LASER) can provide early tissue contrast following ischemia, possibly due to alterations in microscopic susceptibility within the tissue. The purpose of this study was to make a direct in vivo comparison of T2-, T2(dagger)- and diffusion-weighted image contrast during acute ischemia. Acute middle cerebral artery (MCA) occlusion was attempted in 14 rats using a modified Tamura approach incorporating electrocoagulation of the left MCA. T2(dagger)-weighted LASER images (Echo Time [TE]=108 ms), T2-weighted Carr-Purcell-Meiboom-Gill (CPMG) images (TE=110 ms) and diffusion-weighted images (b value=105 s/mm(2)) were acquired at 4 T within 1.5 h of ischemia onset. Tissue contrast in the MCA territory was quantified for histologically verified ischemic tissue (n=6) and in sham controls (n=4). T2(dagger)-weighted LASER images demonstrated greater contrast compared to the T2-weighted CPMG images, and more focal contrast compared to the diffusion-weighted images, suggesting different contrast mechanisms were involved.  相似文献   

10.
We retrospectively examined MR images in 82 patients to evaluate the usefulness of short inversion time inversion recovery (STIR) in bone marrow imaging at 0.5 and 1.5 T. The study included 56 patients at 1.5 T and 26 patients at 0.5 T with a variety of pathologic bone marrow lesions (principally oncological), and compared the contrast and image quality of STIR imaging with spin-echo short repetition time/echo time (TR/TE), long TR/TE, and gradient-echo sequences. The pulse sequences were adjusted for optimal image quality, contrast, and fat nulling. STIR appears especially useful for the evaluation of red marrow (e.g., spine), where contrast between normal and infiltrated marrow is greater than with either gradient-echo or T1-weighted images. STIR is also extremely sensitive for evaluation of osteomyelitis, including soft tissue extent. In more peripheral (yellow) marrow, T1-weighted images are usually as sensitive as STIR. Limitations of STIR include artifacts, in particular motion artifact that at high field strength necessitates motion compensation. At 0.5 T, however, motion compensation is usually not necessary. Also, because of extreme sensitivity to water content, STIR may overstate the margins of a marrow lesion. With these limitations in mind, STIR is a very effective pulse sequence at both 0.5 and 1.5 T for evaluation of marrow abnormalities.  相似文献   

11.
We investigated the effects of transcranial magnetic stimulation (TMS) coils and electroencephalographic (EEG) electrodes on T(2)*-weighted echo-planar images (EPI) at 2.0 T (gradient-echo EPI, mean TE = 53 ms, 2x2x4 mm(3)). In comparison with anatomic gradient-echo images (3D FLASH, TE = 4 ms, 1x1x1 mm(3)), T(2)*-weighted EPI acquisitions of a water-filled spherical phantom revealed severe signal losses and geometric distortions in the vicinity of TMS coils. Even remote effects were observed for image orientations perpendicular to the coil plane. EEG electrodes and the fixation gel caused milder localized distortions. In humans, complications were avoided by the large distance between the TMS coil and the cortical surface and when using an EPI orientation parallel to the plane of the coil. It is concluded that T(2)*-weighted EPI studies of human brain function may be performed without distortions caused by TMS coils and EEG electrodes.  相似文献   

12.
Significant improvements in spin-echo MRS are possible when voxel localisation is performed using high bandwidth frequency offset corrected inversion (FOCI) pulses as opposed to more conventional lower bandwidth pulses. The reduced chemical shift displacement errors result in a spectrum that more accurately reflects the actual metabolite distribution within any region of interest that is selected graphically on a series of scout images, and can lead to improved metabolite detection in the case of homonuclear J-coupled spins. At 4.7T, FOCI pulses with a 20 kHz bandwidth result in extremely sharp and uniform selection profiles, and negligible contamination from outside of the voxel of interest, for all signals in the 1H spectral range that is normally studied. A 'FOCI' adiabatic half-passage is observed to provide good excitation over the 1H spectral range. Single shot performance with echo-time (TE)48 ms is reported using a four-port drive birdcage head coil. GAMMA simulations show that, for many detectable metabolites at 4.7 T, LASER localisation using FOCI pulses with TE=48 ms results in 1H anti-phase spectral components that are the same order as would be obtained from a symmetric PRESS sequence with TE=32 ms. Timing schemes are proposed to enable good measurement of lactate with very little signal loss arising from chemical shift displacement errors at TE=144 and 288 ms.  相似文献   

13.
We evaluated two methods for correcting inhomogeneity-induced signal losses in magnetic resonance gradient-echo imaging that either use gradient compensation or simply acquire thin sections. The strategies were tested in the human brain in terms of achievable quality of T2*-weighted images at the level of the hippocampus and of functional activation maps of the visual cortex. Experiments were performed at 2.0 T and based on single-shot echo-planar imaging at 2. 0 x 2.0 mm(2) resolution, 4 mm section thickness, and 2.0 s temporal resolution. Gradient compensation involved a sequential 16-step variation of the refocusing lobe of the slice-selection gradient (TR/TE = 125/53 ms, flip angle 15 degrees ), whereas thin sections divided the 4-mm target plane into either four 1-mm or eight 0.5-mm interleaved multislice acquisitions (TR/TE = 2000/54 ms, flip angle 70 degrees ). Both approaches were capable of alleviating the inhomogeneity problem for structures in the base of the brain. When compared to standard 4-mm EPI, functional mapping in the visual cortex was partially compromised because of a lower signal-to-noise ratio of inhomogeneity-corrected images by either method. Relative to each other, consistently better results were obtained with the use of contiguous thin sections, in particular for a thickness of 1 mm. Multislice acquisitions of thin sections require minimal technical adjustments.  相似文献   

14.
The purpose of this study was to evaluate the potential of superparamagnetic iron oxide particles (SPIO) as tissue specific contrast agent in magnetic resonance (MR) imaging in detection and characterization of focal hepatic lesions. We investigated 45 patients with focal hepatic lesions. T1-weighted SE (TR 650/TE 15 ms) and T2-weighted SE (TR 2015-2030/TE 45 and 90 ms) unenhanced images were obtained. After SPIO application we performed T1-weighted images with and T2-weighted images with and without fat suppression using the same image parameters. Liver signal intensity decreased by 74% (min 47%, max 83%) on T2-weighted images after application of the contrast agent. Benign lesions (FNH, adenoma) showed an average signal drop of 40% (min 20%, max 47%) whereas malignant lesions showed no significant change of signal intensity on post-contrast images. The mean tumor-to-liver contrast-to-noise ratio (C/N) was improved in all post-contrast sequences irrespective of the lesion type. An additional increase of tumor-to-liver contrast by use of fat suppression technique could be established in the slightly T2-weighted sequence (TE 45 ms). In metastases, divided in different size groups, we could determine a significant size relation of tumor-to-liver C/N. After SPIO application the number of detected lesions increased distinctly, especially small foci are more easily demonstrated. SPIO particles are a efficacious contrast agent for MR examinations of the liver. For tumor characterization T1- and T2-weighted pre- and post-contrast images are necessary. The T1-weighted sequences are helpful to differentiate benign lesions such as cysts and hemangiomas from malignant lesions. Detection and differential diagnoses of hepatic lesions are improved by use of the SPIO-particles.  相似文献   

15.
The purpose of this study was to compare the effects of high dose (HD) and low dose (LD) ferumoxides infusions on lesion-to-liver contrast-to-noise ratio (CNR) using four different T(2)-weighted MR sequences. Seventy-three patients with known colorectal liver metastases underwent T(2)-weighted fast spin echo (FSE) imaging before and after ferumoxides. After ferumoxides, T(2)-weighted dual echo (DE) and T(2)-weighted GRE FLASH images were also obtained. To evaluate the relationship between TE length and lesion-to-liver CNR, the same FLASH sequence was repeated in 18 LD patients after lengthening the TE. Ferumoxides was administered at a dose of 15 micromol/kg (HD) and 7.5 micromol/kg (LD) in 45 and 28 patients, respectively. The effects of HD and LD ferumoxides infusions were measured as the percentage signal intensity change (PSIC) in the liver and lesions, lesion-to-liver CNR and the change in lesion-to-liver CNR (DeltaCNR). In both LD and HD groups, all CNR values obtained after SPIO were significantly greater than those observed with unenhanced FSE (p < 0.01). There was no significant difference between the mean CNR values obtained with either dose for any sequence. With the FLASH sequence, CNR increased progressively with longer TE. At the longest TE of 26 ms, mean CNR was higher than that recorded with any of the other sequences. Although mean liver PSIC was significantly greater in the HD group than in the LD group (p < 0.01) because the mean lesion PSIC was also greater in the HD group, the mean DeltaCNR after ferumoxides was not significantly different in the two groups. LD SPIO enhanced MR significantly increases lesion-to-liver CNR compared with unenhanced images. At 1. 0 T, HD and LD ferumoxides infusions produce comparable lesion-to-liver CNR. Our results suggest that at 1.0 T ferumoxides may be administered at a dose of 7.5 micromol/kg without loss of image quality.  相似文献   

16.
The inability to observe the transient, irregular shape of the frozen region that develops during cryosurgery has inhibited the application of this surgical technique to the treatment of tumors in the brain and deep in visceral organs. We used proton NMR spin-echo and spoiled gradient-echo imaging to monitor the development of frozen lesions during cryosurgery in the rabbit brain and the resulting postervosurgical changes up to 4 hr after freezing. Spoiled gradient-echo images (TE = 14 ms; TR = 50 ms) were acquired during freezing and thawing at a rate of 15 s/slice. Although the frozen region itself is invisible in MR images, its presence is distinguished easily from the surrounding unfrozen soft tissue because of the large contrast difference between frozen and unfrozen regions. T2-weighted spin-echo images (TE = 100 ms, TR = 2 s) obtained after thawing suggest that edema forms first at the margin of the region that was frozen (cryolesion) and then moves into the region's core. Histological examination showed complete necrosis in the cryolesion and a sharp transition to undamaged tissue at the margin of the lesion and its image. Blood-brain barrier (BBB) damage was investigated using gadolinium-DTPA. The region of edema in the T2-weighted spin-echo images was coincident with the area of BBB damage in the Gd-DTPA-enhanced T1-weighted spin-echo images (TE = 33 ms, TR = 400 ms) and both were distinguishable as areas of high signal relative to the surrounding normal tissue. The results of these experiments indicate that MR can both effectively monitor the cryosurgical freezing and thawing cycle and characterize the postcryosurgical changes in tissue during follow-up.  相似文献   

17.
Sterile, chemical and bacterial abscesses were induced in the paraspinal muscles of 16 rats before obtaining magnetic resonance (MR) images using a 0.35-T resistive system. Abscess intensity, T1 and T2 values were recorded before and after the intravenous administration of Gd-DTPA (0.2 mmol/kg). The MR appearances of the abscesses were correlated with histologic sections. Both sterile and bacterial abscess were detected on MR images without the use of contrast medium, particularly on the T2-weighted spin echo sequence (TE/TR 56/2000 ms). However, the inflammatory zones of abscesses markedly enhanced in intensity with a corresponding decrease in T1 values after the administration of Gd-DTPA (TE/TR 28/500 ms). A clear distinction between the necrotic center and the cellular periphery of each abscesses was evident only after contrast enhancement (TE/TR 28/500 ms). Thus paramagnetic Gadolinium-DTPA was beneficial for defining the histologic components of abscesses on spin echo MR images.  相似文献   

18.
The ripening of the tomato fruit was delayed for several days (average 5 days) by a 1-day heat treatment at 42 degrees C. Ethylene production increased during the first 3 h, but, after 6 h inhibition was almost total in tomato fruit incubated at 42 degrees C. However, recovery of ethylene production was rapid if fruits were returned to a temperature of 25 degrees C after heating. In NMR microimaging, three imaging pulse sequences with different repetition and echo times at 42 degrees C were used to obtain the proton density (TR = 6000 ms, TE = 15 ms), the T1 weighted image (TR = 1000 ms, TE = 15 ms) and the T2-weighted image (TR = 6000 ms, TE = 120 ms). After 12 h heating, the water in locular tissues began to show shorter T1 and T2 values. Though the tomatos were returned to 25 degrees C and preserved one more day, the water having a shorter T2 value in locular tissues, did not change. These results show that tomato fruit do not fully recover from heating even after one day, although ethylene production is recovered almost immediately. For this reason, we suggest that some denaturation event inside the tomato, which goes on after the end of heating, is the cause of the delay in tomato ripening.  相似文献   

19.
Recent advances in J-difference-edited proton magnetic resonance spectroscopy (1H MRS) data acquisition and processing have led to the development of Hadamard Encoding and Reconstruction of MEGA-Edited Spectroscopy (HERMES) techniques, which enable the simultaneous measurement of ɣ-aminobutyric acid (GABA), the primary inhibitory amino acid neurotransmitter in the central nervous system, and of glutathione (GSH), the most abundant antioxidant in living tissue, at the commonly available magnetic field strength of 3 T. However, the reproducibility of brain levels of GABA and GSH measured across multiple scans in human subjects using HERMES remains to be established. In the present study, twelve healthy volunteers completed two consecutive HERMES scans of the dorsal anterior cingulate cortex (dACC) to assess the test-retest reproducibility of the technique for GABA and GSH measurements at TE = 80 ms. Eleven of the twelve participants additionally completed two consecutive MEGA-PRESS scans at TE = 120 ms, with editing pulses configured for GSH acquisition, to compare the reliability of GSH in the same voxel measured using the standard MEGA-PRESS at TE = 120 ms. The primary findings of study were that, 1) the coefficient of variation (CV) of measuring GABA with HERMES was 16.7%, which is in agreement with the reliability we previously reported for measuring GABA using MEGA-PRESS; and 2) the reliability of measuring GSH with MEGA-PRESS at TE = 120 ms was more than twice as high as that for measuring the antioxidant with HERMES at TE = 80 ms (CV = 7.3% vs. 19.0% respectively). These findings suggest that HERMES and MEGA-PRESS offer similar reliabilities for measuring GABA, while MEGA-PRESS at TE = 120 ms is more reliable for measuring GSH relative to HERMES at TE = 80 ms.  相似文献   

20.
Spectral analysis of short TE in vivo proton magnetic resonance spectroscopic imaging (MRSI) data are complicated by the presence of spectral overlap, low signal to noise and uncharacterized signal contributions. In this study, it is shown that an automated data analysis method can be used to generate metabolite images from MRSI data obtained from human brain at TE = 25 ms and 1.5 T when optimized pulse sequences and a priori metabolite knowledge are used. The analysis approach made use of computer simulation methods to obtain a priori spectral information of the metabolites of interest and utilized a combination of parametric spectral modeling and non-parametric signal characterization for baseline fitting. This approach was applied to data from optimized PRESS-SI and multi-slice spin-echo SI acquisitions, for which sample spectra and metabolite images are shown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号