首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present cyclodextrin-modified capillary electrophoresis equipped with a microfabricated chip consisting of an array of eight interdigitated microband platinum electrodes (IDs) for simultaneous analysis of three chiral models: epinephrine, norepinephrine and isoproterenol. The IDE chip, positioned very close to the capillary outlet, served as an amplification/detection system. Emerging neurotransmitters at the IDE surface were oxidized at +1.1 V by seven electrodes of the array and then detected by the remaining electrode, poised at +0.0 V. There was an amplification effect on the detecting electrode owing to the recycle between the reduced and oxidized forms of the optical isomers at the electrode surface. The detecting "amplification" current response was governed by the applied potential, the detecting electrode position, the number of adjacent electrodes used for recycling and the distance between the oxidative and reductive electrodes. The six chiral forms of the three neurotransmitters were resolved using 25 mM heptakis(2,6,di-o-methyl)-beta-cyclodextrin with a detection limit of approximately 5 microM. The scheme detected a reduced compound at a reducing potential instead of conventional oxidation detection to alleviate electrode fouling and electroactive interferences. The concurrent oxidation/reduction detection of compounds also facilitated and ascertained peak identification as interfering compounds were unlikely to have the same oxidative/reductive characteristics and mobilities as the analytes of interrogation.  相似文献   

2.
Mu S  Wang X  Li YT  Wang Y  Li DW  Long YT 《The Analyst》2012,137(14):3220-3223
A novel multi-channel electrode array sensing device was fabricated by screen-printing techniques using 96-well plate as the template. To confirm its practical value, we developed a one-step preparation of multi-walled carbon nanotubes (MWCNTs) doped electrode array by an ink containing MWCNTs, which was applied to the simultaneous detection of a variety of biological samples and environmental pollutants. Results demonstrated that the designed sensing device could carry out the multiple measurements of different analytes at the same time, while MWCNTs enhanced the electrocatalytic activity of electrodes toward electroactive molecules. The required amount of each sample was only ~200 μL. Moreover, the excellent differential pulse voltammetric (DPV) response toward dopamine, hydroquinone and catechol was obtained and the detection limits was determined to be 0.337, 0.289 and 0.369 μM, respectively. Comparing it with the traditional screen-printed electrode (SPE), this sensing device possesses the advantages of high-throughput, fast electron transfer rate for electrodes, short-time analysis and low sample consumption.  相似文献   

3.
Male KB  Luong JH 《Electrophoresis》2003,24(6):1016-1024
An array of eight interdigitated microband gold electrodes (IDEs) has been developed together with electrophoretic separation for analysis of chlorinated hydroquinones (ClHQs) and benzoquinones (ClBQs). The IDE chip positioned very close to the separation capillary outlet served as an amplification/detection system without the requirement for frequent "capillary-electrode" alignment. ClHQs, electrophoretically migrating to the IDE surface, were oxidized at +1.1 V by seven electrodes of the array and then detected by the remaining electrode, poised at -0.1 V. Conversely, ClBQs were detected at +1.1 V by the detecting electrode after having been reduced at the 7 adjacent electrodes poised at -0.1 V. There was an amplification effect on both the detecting electrode as well as the adjacent electrodes because of the recycle between ClHQs and ClBQs. The detecting "amplification" current response was dependent on the potentials applied, the position of the detecting electrode on the array, the number of adjacent electrodes being used for recycling and the distance between the oxidative and reductive electrodes. Micellar electrokinetic chromatography (MEKC) separation of the analytes was achieved using 30 mM sodium dodecyl sulfate (SDS) with a detection limit in the range of 2-20 micro M. In addition to a facile "capillary-electrode" alignment, the important aspect described here was the capability of detecting through recycling a reduced compound (in the case of ClHQs) at a negative potential to circumvent fouling and electroactive interferences. An appealing feature was also the concurrent oxidation/reduction detection for each compound to ascertain peak assignment, as interfering compounds are less likely to exhibit the same oxidative/reductive characteristics and electrophoretic mobilities as the target analytes.  相似文献   

4.
In this work we report on the design, microfabrication and analytical performances of a new electrochemical sensor array (ESA) which allows for the first time the simultaneous amperometric detection of nitric oxide (NO) and peroxynitrite (ONOO(-)), two biologically relevant molecules. The on-chip device includes individually addressable sets of gold ultramicroelectrodes (UMEs) of 50 μm diameter, Ag/AgCl reference electrode and gold counter electrode. The electrodes are separated into two groups; each has one reference electrode, one counter electrode and 110 UMEs specifically tailored to detect a specific analyte. The ESA is incorporated on a custom interface with a cell culture well and spring contact pins that can be easily interconnected to an external multichannel potentiostat. Each UME of the network dedicated to the detection of NO is electrochemically modified by electrodepositing thin layers of poly(eugenol) and poly(phenol). The detection of NO is performed amperometrically at 0.8 V vs. Ag/AgCl in phosphate buffer solution (PBS, pH = 7.4) and other buffers adapted to biological cell culture, using a NO-donor. The network of UMEs dedicated to the detection of ONOO(-) is used without further chemical modification of the surface and the uncoated gold electrodes operate at -0.1 V vs. Ag/AgCl to detect the reduction of ONOOH in PBS. The selectivity issue of both sensors against major biologically relevant interfering analytes is examined. Simultaneous detection of NO and ONOO(-) in PBS is also achieved.  相似文献   

5.
Qi H  Ling C  Ma Q  Gao Q  Zhang C 《The Analyst》2012,137(2):393-399
A novel electrochemical immunosensor array for the simultaneous detection of multiple tumor markers was developed by incorporating electrochemically addressing immobilization and one signal antibody strategy. As a proof-of-principle, an eight-electrode array including six carbon screen-printed working electrodes was used as a base array for the analysis of two important tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) and a horseradish peroxidase-labeled antibody was employed as a signal antibody. The immunosensor in the array was fabricated in sequence by covalently coupling the capture antibody onto the surface of the desired working electrode, which was firstly electrochemically addressably grafted with an aminophenyl group by reduction of in situ generated aminophenyl diazonium cation generated from p-phenylenediamine, using glutaraldehyde as cross-linker. This allowed the selective immobilization of the capture antibody at the desired position on a single array via an electrochemical operation. The immunoassay in sandwich mode was performed by specifically binding the targets, second antibodies and one signal antibody to the immunosensor array. The result showed that the steady current density was directly proportional to the concentration of target CEA/AFP in the range from 0.10 to 50 ng mL(-1) with a detection limit of 0.03 ng mL(-1) for CEA and 0.05 ng mL(-1) for AFP (S/N = 3), respectively. This work demonstrates that the employment of an electrochemically addressing method for the fabrication of an immunosensor array and one signal antibody is a promising approach for the determination of multiple tumor markers in clinical samples.  相似文献   

6.
《Analytical letters》2012,45(12):1854-1864
Nickel-nickel oxide core-shell nanorod array electrodes were fabricated and a preliminary application for nonenzymatic glucose determination exhibited excellent performance. The nanorod array electrode was synthesized for the first time by an anodic aluminum oxide template assisted electrochemical deposition technique. Facile oxidation was employed to convert nickel at the outer surface of the nanorods to nickel oxide, resulting in a nickel-nickel oxide core-shell nanorod array. The successful conversion was confirmed by x-ray diffraction, cyclic voltammetry, and scanning electron microscopy. The modified electrode possessed high surface area contributed by the nanorods, and efficient mass transfer due to the wide internanorod gap. The electrode provided high sensitivity (127 microampere square centimeter per millimolar), a low limit of detection (~0.5 micromolar), and a long linear dynamic range (up to 14 millimolar) for the determination of glucose. Accurate determination of glucose in human serum was performed. This synthetic strategy may have further application for the preparation of high surface area thin-film electrodes for a variety of applications.  相似文献   

7.
Recessed generator–collector assemblies consisting of an array of recessed disks (generator electrodes) with a gold layer (collector electrode) deposited over the top‐plane insulator reportedly allow increased selectivity and sensitivity during electrochemical detection of dopamine (DA) in the presence of ascorbic acid (AA), a situation which is frequently encountered. In sensor design, the potential of the disk electrodes is set to the wave plateau of DA, whereas the plane electrode is biased at the irreversible wave plateau of AA before the onset of the DA oxidation wave. Thus, AA is scavenged but DA is allowed to enter the nanocavities to be oxidized at the disk electrodes, and its signal is further amplified by redox cycling between disk and plane electrodes. Several different theoretical approaches are elaborated herein to analyze the behavior of the system, and their conclusions are successfully tested by experiments. This reveals the crucial role of the plane‐electrode area which screens access to the recessed disks (i.e. acts as a diffusional Faraday cage) and simultaneously contributes to amplification of the analyte signal through positive feedback, as occurs in interdigitated arrays and scanning electrochemical microscopy. Simulations also allow for the evaluation of the benefits of different geometries inspired by the above design and different operating modes for increasing the sensor performance.  相似文献   

8.
《Electroanalysis》2017,29(11):2444-2453
Heavy metals, being one of the most toxic and hazardous pollutants in natural water, are of great public health concern. Much effort is still being devoted to the optimization of the electroanalytical methods and devices, particularly for the development of novel electrode materials in order to enhance selectivity and sensitivity for the analysis of heavy metals. The ability of 3D‐printing to fabricate objects with unique structures and functions enables infinite possibilities for the creation of custom‐made electrochemical devices. Here, stainless steel 3D‐printed electrodes (3D‐steel) have been tested for individual and simultaneous square wave anodic stripping analysis of Pb and Cd in aqueous solution. Electrodeposition methods have also been employed to modify the steel electrode surface by coating with a thin gold film (3D−Au) or a bismuth film (3D−Bi) to enhance the analytical performance. All 3D‐printed electrodes (3D‐steel, 3D−Au and 3D−Bi) have been tested against a conventionally employed glassy carbon electrode (GC) for comparison. The surface modified electrodes (3D−Au and 3D−Bi) outperformed the GC electrode demonstrating higher sensitivity over the studied concentration ranges of 50–300 and 50–500 ppb for Pb and Cd, respectively. Owing to the bismuth property of binary alloys formation with heavy metals, 3D−Bi electrode displayed well‐defined, reproducible signals with relatively low detection limits of 3.53 and 9.35 ppb for Pb and Cd, respectively. The voltammetric behaviour of 3D−Bi electrode in simultaneous detection of Pb and Cd, as well as in individual detection of Pb in tap water was also monitored. Overall, 3D‐printed electrodes exhibited promising qualities for further investigation on a more customizable electrode design.  相似文献   

9.
《Electroanalysis》2003,15(21):1677-1681
This work describes the use of interdigitated array electrodes (IDAE) for proton detection. Methanol electrooxidation in sulfuric acid solution was exemplified. Reduction currents originating in the reaction product generated by methanol electrooxidation on a Pt generator electrode were observed at the Pt collector electrode, the potential of which was fixed in the hydrogen evolution region. In order to reduce the background current of hydrogen evolution, an Hg‐plated Pt collector electrode was fabricated. Compared to the Pt collector electrode, the reduction current observed at the Hg collector electrode was extremely small. The product detected was found to be a proton from the current responses observed at Pt and Hg collector electrodes.  相似文献   

10.
Mecker LC  Filla LA  Martin RS 《Electroanalysis》2010,22(19):2141-2146
In this communication, we demonstrate that a carbon ink microelectrode array, where the electrodes are held at the same potential, affords significant signal enhancement in microchip electrophoresis with amperometric detection. The ability to fabricate an array of carbon ink microelectrodes with a palladium decoupler was demonstrated and the resulting electrodes were integrated with a valving microchip design. The use of an 8 electrode array led to a significant improvement in the limits of detection at the expense of separation resolution due to the increased detection zone size. It is also shown that microdialysis sampling can be integrated with the microchip device and a multi-analyte separation achieved.  相似文献   

11.
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.  相似文献   

12.
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.  相似文献   

13.
A simple method using an unmodified edge plane pyrolytic graphite electrode (EPPGE) is reported for the simultaneous determination of dopamine (DA), serotonin (ST) and ascorbic acid (AA). The performance of this electrode is superior to other unmodified carbon-based electrodes and also to many modified electrodes in terms of detection limit, sensitivity and peak separation for determination of DA, ST and AA. Using this method, detection limits of 90 nM, 60 nM and 200 nM were obtained for DA, ST and AA respectively. No electrode fouling is observed during a set of experiments and good sensitivity is obtained for the simultaneous determination of DA, ST and AA. The peaks for the three species are well resolved from each other and the electrode is successfully utilised for their determination in standard and real samples.   相似文献   

14.
We present Finite Element Method (FEM) simulations of interdigitated array (IDA) electrode geometries to study and verify redox selectivity and redox cycling amplification factor. The simulations provide an adequate explanation of an earlier found, but poorly understood, high amplification factor (65×) in a 1 μm‐spaced IDA microdevice. Moreover, using the FEM calculations we present selectivity measurements with IDA electrodes in a mixture of two redox species, as for example dopamine and ferricyanide. We show that it is possible to electrochemically detect dopamine in presence of the stronger reductor ferricyanide, which is impossible with direct amperometric detection, with the use of IDA electrodes with proper polarization potential of the collector electrode. Using our simulations, we show that a theoretical selectivity of dopamine over ferricyanide of 11 can be achieved.  相似文献   

15.
J. Alpí  zar  A. Cladera  V. Cerd    E. Lastres  L. Garcí  a  M. Catasú  s 《Analytica chimica acta》1997,340(1-3):149-158
A flow injection (FI) method using multiple differential pulse voltammetric detection for the simultaneous determination of two metal ions was developed and applied to the resolution of Cd(II)-Pb(II) mixtures. The metals are detected by applying two sequential pulses to a three-electrode voltammetric system that uses a flow-through cell accommodating a static mercury-drop working electrode. The influence of the electrode area, flow-rate, pulse frequency, pulse width and sampling time was investigated. Under the experimental conditions used, the two metals were found to interfere with each other. The use of a neural network allows the simultaneous determination of both, in mixtures, with good accuracy. The proposed method is applicable to other complex systems involving different working electrodes and more than two electroactive species.  相似文献   

16.
基于自制的集成化三阵列金膜电极,构建了一个简单、灵敏、非标记的凝血酶阵列电化学适体传感器。以聚乙烯不干胶掩膜版法结合金属溅射沉积技术,在FR-4玻璃纤维板上制作了由3个金膜工作电极、1个大面积金膜对电极和1个厚膜Ag/AgCl参比电极构成的集成化金膜阵列电极系统。以集成化金膜阵列电极作为基础电极,采用巯基自组装技术将带巯基的凝血酶适体固定在3个金工作电极表面,巯基己醇封闭后获得三阵列凝血酶适体传感器,以电活性物质铁氰化钾作为电化学探针,基于凝血酶适体和凝血酶结合前后铁氰化钾在电极表面传质的不同导致电流变化进行凝血酶的测定。采用方波脉冲伏安法,铁氰化钾氧化峰电流的变化值与凝血酶浓度在 1.52~63 nmol/L范围内呈良好的线性关系,检出限(S/N=3)为0.92 nmol/L。  相似文献   

17.
The voltammetric behaviour of selenium(IV) was studied at platinum and gold electrodes in sulphuric acid, perchloric acid and potassium chloride media as a basis for its voltammetric detection. The best voltammetric behaviour was recorded at gold electrodes with perchloric acid as the supporting electrolyte. The concomitant presence of metals, such as copper or lead, and of model biomolecules, such as bovine serum albumin, in the solution resulted in a deterioration of the electrochemical response for selenium(IV). Quantitative detection of selenium(IV) by square wave anodic stripping voltammetry at both a millimetre-sized gold disc electrode and a microband electrode array revealed linear responses to selenium concentration in the ranges 5–15 μM and 0.1–10 μM, respectively, with 60 s preconcentration. The sensitivities were 6.4 μA μM−1 cm−2 and 100 μA μM−1 cm−2 at the disc and the microband array, respectively. The detection limit at the microband electrode array was 25 nM, illustrating the potentiality of such microelectrodes for the development of mercury-free analytical methods for the trace detection of selenium(IV).  相似文献   

18.
Acetylcholinesterase (ACh) and acid phosphatase (AcP) have been simultaneously cross‐linked onto an array of SPCEs, which was set up by a Ag/AgCl reference electrode, a carbon counter electrode and two carbon working electrodes. The detection of As(III) and As(V) is based on their enzymatic inhibitory effect. Different immobilization conditions, substrates, supporting electrolytes and chronoamperometric experimental conditions have been studied for the sensitive and selective detection of both species of arsenic in complex matrices, such as tap water and wine, at once.  相似文献   

19.
《印度化学会志》2023,100(2):100900
In the present work RHDAC electrode was used to electrosorption of hexavalent chromium and fluoride (HCAF) by capacitive deionization from the aqueous feed. In this study multicomponent isotherm (MCI) modeling were done with different six MCI models for simultaneous removal of HCAF using RHDAC electrodes. This RHDAC electrode performance was indicated the simultaneous maximum electrosorption 2.47 and 2.34 mg/g for HCAF respectively for 100 mg/L aqueous feed. The results show that MCIM3 (Extended Langmuir) and MCIM5 (Non modified Redlich Peterson) models were found more fit to with experimental data with lower MPSD for both HCAF than other MCI models. The RHDAC was an effective electrode material for HCAF sorption from low concentrated feed.  相似文献   

20.
A sensitive and selective HPLC method with coulometric electrode array detection for the determination of pipecuronium bromide and its four impurities has been developed. The coulometric electrode array detection at increasing potentials from +300 to +900mV of the porous graphite electrode versus the palladium reference electrode was used. The limit of detection and quantitation for pipecuronium bromide was 8 and 25ngml(-1), respectively. This elaborate method for the simultaneous analysis of pipecuronium bromide and its impurities proved to be fast, precise, accurate, sensitive, and could be applied to analysis in substances and in pharmaceutical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号