首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hou S  Zhu J  Ding M  Lv G 《Talanta》2008,76(4):798-802
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for simultaneous determination of three representative phytohormones in plant samples: gibberellic acid (GA3), indole-3-acetic acid (IAA) and abscisic acid (ABA). A solid-phase extraction (SPE) pretreatment method was used to concentrate and purify the three phytohormones of different groups from plant samples. The separation was carried out on a C18 reversed-phase column, using methanol/water containing 0.2% formic acid (50:50, v/v) as the isocratic mobile phase at the flow-rate of 1.0 mL min−1, and the three phytohormones were eluted within 7 min. A linear ion trap mass spectrometer equipped with electrospray ionization source was operated in negative ion mode. Selective reaction monitoring (SRM) was employed for quantitative measurement. The SRM transitions monitored were as 345 → 239, 301 for GA3, 174 → 130 for IAA and 263 → 153, 219 for ABA. Good linearities were found within the ranges of 5–200 μg mL−1 for IAA and 0.005–10 μg mL−1 for ABA and GA3. Their detection limits based on a signal-to-noise ratio of three were 0.005 μg mL−1, 2.2 μg mL−1 and 0.003 μg mL−1 for GA3, IAA and ABA, respectively. Good recoveries from 95.5% to 102.4% for the three phytohormones were obtained. The results demonstrated that the SPE-LC–MS/MS method developed is highly effective for analyzing trace amounts of the three phytohormones in plant samples.  相似文献   

2.
Green onions (Allium fistulosum) enriched with 10 or 100 μg mL− 1 Se(IV) or SeMet were analyzed for total selenium and species distribution. Anion and cation exchange chromatographies were applied for the separation of selenium species with mass spectrometric detection. Two different sample preparation methods (NaOH and enzymatic) were compared from the Se extraction efficiency point of view. Total selenium concentration accumulated by the onions reached the 200 μg g− 1 level expressed for dry weight when applying SeMet at a concentration of 100 μg mL− 1 as the source of Se. Speciation studies revealed that both in onion bulbs and leaves the predominant form of organic selenium is Se-methyl-selenocysteine (MeSeCys). When Se(IV) was applied for Se-enrichment at a concentration level of 100 μg mL− 1 both onion leaf and bulb contained a significant amount of inorganic selenium. An unknown compound was also detected.  相似文献   

3.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

4.
Galera MM  García MD  Valverde RS 《Talanta》2008,76(4):815-823
This study reports the first analytical application of luminol chemiluminescence reaction for the sensitive detection of two benzoylurea insecticides (diflubenzuron and triflumuron). Off-line experiments demonstrated that previously irradiated traces of these benzoylurea insecticides largely enhanced the chemiluminescence emission yielded from the oxidation of luminol in methanol:water mixtures, by potassium permanganate in alkaline medium, the enhancement being proportional to the concentration of both pesticides. The two benzoylureas were determined in tomato samples by coupling liquid chromatography with post-column photoderivatization and detection based on this chemiluminescence reaction. Tomato samples were extracted using the QuEChERS method based on extraction with acetonitrile and dispersive solid-phase clean-up using primary and secondary amine (PSA). Interferences due to matrix effect were overcome by using matrix-matched standards. The optimised method was validated with respect to linearity, limits of detection and quantification, precision and accuracy. Under the optimised conditions, calibrations graphs were linear between 0.05 and 0.50 μg mL−1 for diflubenzuron and between 0.10 and 1.00 μg mL−1 for triflumuron. Method detection limits were 0.0025 and 0.0131 μg mL−1 (equivalent to 0.0005 and 0.0026 mg kg−1) and quantification limits were 0.05 and 0.10 μg mL−1 (equivalent to 0.01 and 0.02 mg kg−1) for diflubenzuron and triflumuron, respectively. In both cases, quantification limits were lower than the maximum residue levels (MRLs) established by the European legislation. The relative standard deviation of intra-day precision was below 10% and recoveries were between 79.7% and 94.2% for both pesticides.  相似文献   

5.
Wang X  Zhao X  Liu X  Li Y  Fu L  Hu J  Huang C 《Analytica chimica acta》2008,620(1-2):162-169
In this study, a new method was developed for analyzing malathion, cypermethrin and lambda-cyhalothrin from soil samples by using homogeneous liquid–liquid extraction (HLLE) and gas chromatography with electron capture detector (GC–ECD). Acetone was used as extraction solvent for the extraction of target pesticides from soil samples. When the extraction process was finished, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to carbon tetrachloride, using HLLE. Under the optimum conditions, linearity was obtained in the range of 0.05–40 μg kg−1 for malathion, 0.04–10 μg kg−1 for lambda-cyhalothrin and 0.05–50 μg kg−1 for cypermethrin, respectively. Coefficients of correlation (r2) ranged from 0.9993 to 0.9998. The repeatability was carried out by spiking soil samples at concentration levels of 2.5 μg kg−1 for lambda-cyhalothrin, and 10 μg kg−1 for malathion and cypermethrin, respectively. The relative standard deviations (RSDs) varied between 2.3 and 9.6% (n = 3). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, varied between 0.01 and 0.04 μg kg−1. The relative recoveries of three pesticides from soil A1, A2 and A3 at spiking levels of 2.5, 5 and 10 μg kg−1 were in the range of 82.20–91.60%, 88.90–110.5% and 77.10–98.50%, respectively. In conclusion, the proposed method can be successfully applied for the determination of target pesticide residues in real soil samples.  相似文献   

6.
Sun H  Qiao F  Liu G  Liang S 《Analytica chimica acta》2008,625(2):154-159
A simple and sensitive method for the simultaneous determination of six fluoroquinolones from serum samples was developed by selective molecularly imprinted matrix solid-phase dispersion (MI-MSPD) coupled with chromatographic separation. By using ethylene glycol dimethacrylate as crosslinker and reformative methanol–water system as reaction medium, the improved water-compatible imprinted polymers were synthesized which show higher affinity to template and its analogues in aqueous environment. The molecularly imprinted polymers (MIPs) were applied as the selective dispersant of matrix solid-phase dispersion (MSPD) could selectively extracted the six fluoroquinolones from serum, while interferences originated from serum matrices were eliminated simultaneously. Good linearity was obtained in a range of 0.05–100 μg mL−1 with the correlation coefficients >0.999. The average recoveries of the six fluoroquinolones at four different spiked levels (0.25–10 μg mL−1) were ranged from 72.2% to 114.1% with the relative standard deviations less than 6.6%. This method is simple and sensitive, and can be used as an alternative tool to the existing HPLC methods for analyzing the residues of fluoroquinolones in biological samples.  相似文献   

7.
This work reports on a novel nanosized calcium carbonate–chitosan (nanoCaCO3–chi) composite film fabricated by a one-step co-electrodeposition method. The generated nanoCaCO3-based matrix possessed a three-dimensional (3D) porous, network-like structure, providing a favorable and biocompatible microenvironment to immobilize enzyme. By using such a composite film as enzyme immobilization matrix, a highly sensitive and stable acetylcholinesterase (AChE) sensor was achieved for determination of methyl parathion as a model of organophosphate pesticides (OPs) compounds. The inhibition of methyl parathion was proportional to its concentration ranging from 0.005–0.2 to 0.75–3.75 μg mL−1. The detection limit was found to be as low as 1 ng mL−1 (S/N = 3). The designed biosensor exhibited good reproducibility and acceptable stability.  相似文献   

8.
The synthesis of one pyrethroid insecticide [2-methyl-4-oxo-3-prop-2-yn-1-ylcyclopent-2-en-1-yl-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate (Abbrev. JZ) (Fig. 1)] conjugated with a series of α-terthienyl derivatives (2–8) (Fig. 1) by palladium/copper-catalyzed cross-coupling reaction is presented here for evaluating the photoactivated cytotoxicity. The photoactivated cytotoxicity on Spodoptera litura (SL) cell line was detected by MTT assay. The inhibitory activity of all the conjugates was enhanced in the irradiation condition, compared with that of JZ. The IC50 values of the most effective compound 9 (Fig. 1) treated with irradiation were 11.60 μg mL−1 at 24 h and 8.93 μg mL−1 at 48 h, respectively. Generation of intracellular reactive oxygen species (ROS) and change of mitochondrial transmembrane potential (MMP) on SL cells treated with compound 9 were used for the further photoactivated study. A summary of these experiments on compound 9 demonstrated the notable ROS generation and dramatic MMP decrease when irradiated with UVA light. The results also represented statistically significant difference between dark and irradiation treatment of compound 9. However, in control and JZ groups, the effects were not statistically different. It was proved that our prepared compounds were ideal candidates for new photoactivated pyrethroid insecticides.  相似文献   

9.
Mir SA 《Analytica chimica acta》2008,620(1-2):183-189
A rapid technique for determination of nitrate by acid reduction and diazotization at elevated temperature has been standardized. The technique is based on quantitative diazotization of sulfanilamide by nitrate on incubation in boiling water bath for 3, 5 or 10 min in presence of high concentration of HCl, ca. 64.5%. The diazotized sulfanilamide is coupled at room temperature to N-1-(naphthyl)-ethylenediamine dihydrochloride, and the chromophore evaluated spectrophotometrically at 540 nm. The technique provides linear estimate of nitrate over the test range of 0.5 through 10 μg N mL−1 sample with all test incubation time periods using alkali nitrate and nitric acid as sources of nitrate anion. Urea treatment enables selective determination of nitrate in presence of nitrite with overall 99 ± 1% recovery, and without affecting nitrate determination (P > 0.1) or its regression coefficient. The technique has obvious advantages over metal-reduction technique. It is simple, rapid, selective in presence of nitrite, and an inexpensive method for routine determination of nitrate with detection range 0.5–10 μg N mL−1 sample. Besides, the technique provides opportunity to detect nitric acid as low as 35 μM even in presence of other acids.  相似文献   

10.
A new rapid spectrophotometric method for the determination of Si is described. Chloranilic acid (CA) reacts with Si(IV) forming a complex, which is stable for several hours. The procedure is suitable for the determination of Si in the concentration range of 0.5–5.0 μmol/ml, at pH 1.25 ± 0.05 measured at 370 nm. The relative standard deviation at the level of 1.0 μmol/ml Si is ± 3.5%. Of the foreign ions investigated, Fe, Ti, Mo, and PO43− interfere significantly.  相似文献   

11.
The aim of this study was to develop an optical biosensor inhibition immunoassay, based on the surface plasmon resonance (SPR) principle, for use as a screening test for 13 (fluoro)quinolones, including flumequine, used as veterinary drugs in food-producing animals. For this, we immobilised various quinolone derivatives on the sensor chip and tested binding of a range of different antibodies (polyclonal and one engineered antibody) in the presence and absence of free (fluoro)quinolones. The main challenge was to detect flumequine in an assay giving good results for the other compounds. One antigen–antibody combination proved satisfactory: polyclonal antibodies raised against a dual immunogen and, on the sensor chip, a fluoroquinolone derivative. It was the first time that this concept of the bi-active antibody was described in the literature.The assay, optimised for detection in three matrices (poultry muscle, fish, and egg), was tested on incurred samples prepared by liquid extraction followed by two washing steps. This rapid, simple method proved adequate for detecting at least 13 (fluoro)quinolones at concentrations below established maximum residue levels (MRLs). The reference molecule norfloxacin could be detected in the range of 0.1–10 μg kg−1 in extracts of egg and poultry meat and in the range of 0.1–100 μg kg−1 in extracts of fish. The determined midpoints of these calibration curves were about 1, 1.5 and 3 μg kg−1 in poultry meat, egg and fish, respectively.  相似文献   

12.
Pd (IV)-doped CuO oxide composite nanofibers (PCNFs) have been successfully fabricated via electrospinning and then employed to construct an amperometric non-enzymatic glucose sensor. The PCNFs based glucose sensors display distinctly enhanced electrocatalytic activity towards the oxidation of glucose, showing significantly lower overvoltage (0.32 V) and ultrafast (1 s) and ultrasensitive current (1061.4 μA mM−1 cm−2) response with a lower detection limit of 1.9 × 10−8 M (S/N = 3). Additionally, excellent selectivity, reproducibility and stability have also been obtained. These results indicate that PCNFs are promising candidates for amperometric non-enzymatic glucose detection.  相似文献   

13.
The reduction of 17-ketosteroid estrone or androstenedione to corresponding 17α- and 17β-estradiol or testosterone and epitestosterone has been performed with Saccharomyces cerevisiae. In the analysis of the cell culture, the solid-phase extraction (SPE) method was on-line coupled to high-performance liquid chromatography electrospray-ionization/mass spectrometry (HPLC-ESI/MS) for sample pretreatment to eliminate the complicated matrix interference and preconcentrate of the analytes before chromatographic separation. A novel quantification method with the continuous postcolumn infusion of internal standard was developed for the determination of substrate and products. This novel quantitative method can stabilize and enhance the ionization of all analytes during analysis. The HPLC-ESI/MS analysis of estrone, 17α-, and 17β-estradiol was operated with a negative ion mode and the analysis of androstenedione, testosterone, and epitestosterone was operated with a positive ion mode. The optimal concentration of the internal standard progesterone with the continuous postcolumn infusion technique was 3 μg mL−1 for estrogen analysis and 1 ng mL−1 for androgen analysis and both were at a constant infusion rate of 0.5 μL min−1. All of the linear correlation coefficients of the standard calibration curves were over 0.99 and had a linear range from 0 to 50 ng mL−1. The limit of detections (LODs) and the limit of quantitations (LOQs) for steroids analyzed were from 0.12 to 0.36 ng mL−1 and from 0.4 to 1.2 ng mL−1, respectively. The analysis accuracies and precisions were better than 94% and lower than 8.8% R.S.D., respectively. The developed method for the analysis of steroids in the cell culture was successful.  相似文献   

14.
Salicylaldehyde rhodamine B hydrazone (SRBH) was developed as a new spectrofluorimetric probe for the selective and sensitive detection of CrO42− in acidic conditions. The proposed method was based on the special oxidation reaction between non-fluorescent SRBH by potassium dichromate to produce a highly fluorescent rhodamine B, as a product. Under the optimum conditions described, the fluorescence enhancement at 591 nm was good linearly related to the concentration of CrO42− from 1.0 × 10−8 to 3.0 × 10−7 M (0.42–12.6 ng mL−1) with a correlation coefficient of R2 = 0.9989 (n = 10) and a detection limit of 1.5 × 10−9 M (0.063 ng mL−1). The relative standard deviation (R.S.D.) was 2.0% (n = 6). The proposed method was also successfully applied to the determination of chromium (VI) in drinking water, river water and synthetic samples.  相似文献   

15.
A new approach for decreasing the detection limit for a copper(II) ion-selective electrode (ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3–5.4, and its detection limit is 2.7 × 10−8 mol L−1 (1.2 μg L−1). This sensor exhibits a good Nernstian slope of 29.4 ± 0.5 mV/decade in a wide linear concentration range of 2.3 × 10−7 to 1.0 × 10−3 mol L−1 of Cu(II). It has a short response time (8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples.  相似文献   

16.
3-3′-Dimethoxybenzidine (o-dianisidine, ODA) is oxidised by Br2, among other oxidants, generating a compound that absorbs at 450 nm, while the non-oxidised reagent absorbs in the UV region. This reaction has been used previously as the basis of a continuous-flow method for the determination of bromate in ozonised water, with a detection limit lower than the maximum permitted for drinking water (10 μg L−1). The only interference observed in the method was that due to the chlorite ion (ClO2), which generated the same ODA bromation product. Thus, in systems in which O3 is employed as a disinfectant and disinfection is later enhanced with ClO and ClO2, there exists the possibility of finding BrO3 and ClO2, oxoanions generated as subproducts. The kinetic behaviour of the reaction between bromate and chlorite with bromine in acidic medium is different, allowing the proposal of a continuous-flow method for the simultaneous or sequential determination of both subproducts in water purification systems. None of the other subproducts interfered in the reaction. Kinetic differentiation was achieved by combining the temperature of the reaction and the length of the coils, after which it was possible to determine both analytes sequentially within a concentration range of 6–160 μg L−1.  相似文献   

17.
The insoluble multi-walled carbon nanotubes (MWNT) was successfully dispersed into water in the presence of hydrophobic surfactant. After that, MWNT film-coated glassy carbon electrode (GCE) was achieved via dip-coating and evaporating water. Owing to huge surface area, high sorption capacity and subtle electronic properties, MWNT film exhibits highly efficient accumulation efficiency as well as considerable surface enhancement effects to Sunset Yellow and Tartrazine. As a result, the oxidation peak currents of Sunset Yellow and Tartrazine remarkably increase at the MWNT film-modified GCE. Based on this, a novel electrochemical method was developed for the simultaneous determination of Sunset Yellow and Tartrazine. The limits of detection are 10.0 ng mL−1 (2.2 × 10−8 mol L−1) and 0.1 μg mL−1 (1.88 × 10−7 mol L−1) for Sunset Yellow and Tartrazine. Finally, the proposed method was successfully used to detect Sunset Yellow and Tartrazine in soft drinks.  相似文献   

18.
Spectrophotometric Determination of Titanium(IV) with Chlorpromazine HydrochlorideThe extraction of titanium(IV)-thiocyanate complex from hydrochloric acid with chlorpromazine (CPA) dissolved in chloroform has been studied. The composition of the extracted species was found to be (CPAH+)2[Ti(CNS)62−]. This complex, dissolved in chloroform, has maximum absorbance at 417 nm and a molar absorptivity of 2.6 × 104 mol−1 · cm−1 · liter. Titanium(IV) was determined spectrophotometrically in the organic phase. Beer's law is obeyed in the titanium concentration range 0.2-2.2 μg/ml.  相似文献   

19.
A simple and efficient liquid-phase microextraction (LPME) technique was developed using directly suspended organic microdrop coupled with gas chromatography–mass spectrometry (GC–MS), for the extraction and the determination of phthalate esters (dimethyl phthalate, diethyl phthalate, diallyl phthalate, di-n-butyl phthalate (DnBP), benzyl butyl phthalate (BBP), dicyclohexyl phthalate and di-2-ethylhexyl phthalate (DEHP)) in water samples. Microextraction efficiency factors, such as nature and volume of the organic solvent, temperature, salt effect, stirring rate and the extraction time were investigated and optimized. Under the optimized extraction conditions (extraction solvent: 1-dodecanol; extraction temperature: 60 °C; microdrop volume: 7 μL; stirring rate: 750 rpm, without salt addition and extraction time: 25 min), figures of merit of the proposed method were evaluated. The values of the detection limit were in the range of 0.02–0.05 μg L−1, while the R.S.D.% value for the analysis of 5.0 μg L−1 of the analytes was below 7.7% (n = 4). A good linearity (r2 ≥ 0.9940) and a broad linear range (0.05–100 μg L−1) were obtained. The method exhibited enrichment factor values ranging from 307 to 412. Finally, the designed method was successfully applied for the preconcentration and determination of the studied phthalate esters in different real water samples and satisfactory results were attained.  相似文献   

20.
Flow cytometric immunoassay for sulfonamides in raw milk   总被引:2,自引:0,他引:2  
Sulfonamide antibiotics are applied in veterinary medicine for the treatment of microbial infections. For the detection of residues of sulfonamides in milk, a multi-sulfonamide flow cytometric immunoassay (FCI) was developed using the Luminex MultiAnalyte Profiling (xMAP) technology. In this automated FCI, a previously developed biotinylated multi-sulfonamide mutant antibody (M.3.4) was applied in combination with fluorescent beads, directly coated with a sulfathiazole derivative, and streptavidin–phycoerythrin (SAPE) for the detection. With this FCI, at least 11 different sulfonamides could be detected (more than 50% inhibition at the 100 ng mL−1 level) and, after an incubation of 1 h, measurements were rapid (10 s per sample). For the application with raw milk, a 96-well microplate-based filtration step was included into the protocol to remove disturbing milk fat particles. Because of differences in sensitivity towards different sulfonamides, the FCI was considered and validated as a qualitative screening assay. For sulfadoxine, the most applied sulfonamide in Dutch dairy cattle, the detection capability (CCβ) was <50 μg L−1 and this level seems feasible for five other sulfonamides. For sulfadiazine, the CCβ was <200 μg L−1 and this level seems feasible for four other sulfonamides. A major advantage of the applied xMAP-technology, with its 100 different color-coded bead sets, is the possibility to develop multiplex immunoassays for the simultaneous detection of several antibiotics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号