首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Magnesium can be separated from calcium by elution with 3.0 M hydrochloric acid containing 60% ethanol from a column of AG50W-X8 cation-exchange resin. Calcium is retained and can be eluted with 3.0 M hydrochloric acid or 2.0 M nitric acid. The separation factor of (αMgca=5.6 is considerably higher than that in aqueous hydrochloric acid and comparable to those obtained with organic complexing reagents. Separations are sharp and quantitative; up to 10 mmol of magnesium can be separated from 0.01 mmol of calcium and vice versa on a 60-ml column. Al, Fe(III), Mn, Ni(II), Co(II), Zn, Cd, Cu(II), Pb(II), U(VI), Be, Ga, Ti(IV) in the presence of H2O2 and many other elements accompany magnesium and can be separated from calcium quantitatively. Sr, Ba, Zr, Hf, Th, Sc, La and the rare earths are retained together with Ca, but can be separated by other methods.  相似文献   

2.
Gold(III) can be separated from Cd, In. Zn, Ni, Cu(II), Mn(II), Co(II), Mg, Ca, Al, Fe(III), Ga and U(VI) by adsorbing these elements on a column of AG50W-X8 sulphonated polystyrene cation-exchange resin from 0.1M HCl containing 60% v v acetone, while Au(III) passes through and can be eluted with the same reagent. Separations are sharp and quantitative. The amounts of gold retained by the resin are between 1 and 2 orders of magnitude lower than encountered during adsorption from aqueous 0.1M HCl. Recoveries for mg amounts of gold are 99.9% or better and for ng amounts are still better than 99%, as shown by radioactive tracer methods. Hg(II), Bi, Sn(IV), the platinum metals and some elements which tend to form oxy-anions in dilute acid accompany gold. All other elements, though not investigated in detail, should be retained, according to their known distribution coefficients. Relevant elution curves, results of quantitative separations of binary mixtures and of recovery tests are presented.  相似文献   

3.
Strelow FW  Baxter C 《Talanta》1969,16(8):1145-1151
Tervalent rare earths and Sc are separated from the silicate-forming elements Al, Fe(III), Mg and Ti(IV), and also from Mn(II), U(VI), Be, Ga, In(III), Tl(III), Bi(III), Ni, Zn, Cu(II), Cd and Pb by cation-exchange chromatography. The other elements are eluted with 3.0 M HC1 containing 50% ethanol from a column of 60 ml of AG50W-X8 resin (200-400 mesh) while the rare earths are retained. Separation factors are larger than in aqueous hydrochloric acid. Th, Zr, Hf, Ba, Sr, Ca, K, and Rb are the only elements which accompany the rare earths group, but these can easily be separated by other methods which are described. Relevant distribution coefficients, elution curves and accurate results of quantitative separations of synthetic mixtures are presented.  相似文献   

4.
Strelow FW 《Talanta》1980,27(3):231-236
Gallium can be separated from Zn, Cu(II), In, Cd, Pb(II), Bi(III), Au(III), Pt(IV), Pd(II), Tl(III), Sn(IV) and Fe(III) by elution of these elements with 0.50M hydrobromic acid in 80% acetone medium, from a column of AG50W-X4 cation-exchange resin. Gallium is retained and can be eluted with 3M hydrochloric acid. Separations are sharp and quantitative except for iron(III) which shows extensive tailing. With 0.20M hydrobromic acid in 80% acetone as eluting agent, all the species above except iron(III) and copper(II) can be separated from gallium with very large separation factors. Only a 1-g resin column and small elution volumes are required to separate trace amounts and up to 0.5 mmole of gallium from more than 1 g of zinc or the other elements. Hg(II), Rh(III), Ir(IV), Se(IV), Ge(IV), As(III) and Sb(III) have not been investigated, but should be separated together with zinc according to their known distribution coefficients. Relevant elution curves, results for the analysis of synthetic mixtures and for amounts of some elements remaining in the gallium fraction are presented.  相似文献   

5.
Lithium can be separated from sodium, beryllium and many other elements by eluting lithium with 1 M nitric acid in 80% methanol from a column of AG50W-X8 sulphonated polystyrene cation-exchange resin. The separation factor is not quite as large as that in 1 M hydrochloric acid in 80% methanol, but many elements, such as Zn, Cd, In, Pb(II), Bi(III) and Fe(III), which form chloride complexes in 1 M HCl-80% methanol are retained quantitatively together with Na, Be, Mg, Ca, Mn(II), Al, Ti(IV), U(VI), and many other elements, when 1 M HNO3-80% methanol is used for elution of lithium. A method for the accurate determination of traces of lithium in rock samples is described, and some results obtained are presented together with relevant distribution coefficients, elution curves and results for the analysis of synthetic mixtures.  相似文献   

6.
Traces of lead and minor amounts up to 20 mg, can be separated from gram amounts of thallium by cation-exchange chromatography on a column containing only 2 g of AG50W-X4 resin. Thallium passes through the column in 0.1 M HCl in 40% acetone. The retained lead can be eluted with 3 M HCl or HNO3. Other elements, including Cd, Zn, In, Ga, Cu(II), Fe(III). Mn(II), Co(II). Ni(II), U(VI) and Al, are retained quantitatively with lead. Only Hg(II), Au(III), the platinum metals, bismuth and elements forming oxyanions accompanying thallium. Results for the determination of trace elements in 99.999% pure thallium are presented.  相似文献   

7.
Strelow FW 《Talanta》1985,32(10):953-956
Traces of silver and amounts up to 50 mg can be separated from up to gram amounts of Zn, Cu(II), Ni, Co(II), Mg, Be, Ti(IV), V(IV), Li and Na by eluting these with 2.0M nitric acid from a column containing 54 ml (20 g) of macroporous AG MP-50 cation-exchange resin of 100-200 mesh particle size, in the H(+)-form. Silver is retained and can be eluted with 0.5M hydrobromic acid in 9:1 v v acetone-water. Separations are sharp and quantitative and only a few microg of the other elements are found in the silver fraction. Cadmium and manganese (II) can also be separated quantitatively but show tailing and require larger elution volumes. Some typical elution curves and results of analyses of synthetic mixtures are presented.  相似文献   

8.
Beryllium is separated from Mg, Ca, Mn(II), Fe(III), Al, Co(II). Zn. U(VI), La and Gd by elution with 2.0 M nitric acid in 70 % methanol from a column of AG50W-X8 sulphonated polystyrene cation exchanger, while the other elements are retained quantitatively. Sr, Ba, Sc, Y, the other lanthanides, Zr, Hf, Th, Ga, In, Cd and Ni(II) should also be separated according to their distribution coefficients or elution behaviour. Separations are sharp and recoveries quantitative from millimolar amounts down to 10 μg of beryllium. The separation of Ti(IV) and Cu(II) from beryllium is not satisfactory and requires rather large columns. Bi(III), Pb(II), Hg(II) and the alkali metals are eluted together with beryllium, but can be separated by other methods. Typical elution curves and results for the quantitative separation of binary synthetic mixtures are presented.  相似文献   

9.
Summary The cation-exchange behaviour of Mg(II), Ca(II), Sr(II), Ba(II), Mn(II), Cd(II), Co(II), Ni(II), Zn(II), Cu(II) and Fe(III) in succinate media at various concentrations and pH, was studied with Dowex 50 WX8 resin (200–400 mesh) in the NH 4 + form. As examples separations of Cd(II)/Co(II), Cd (II)/Ni(II), Fe(III)/Cu(II)/Ni(II) and Mg(II)/Ca(II)/Sr(II)/Ba(II) have been achieved.This work was supported by C.N.R. of Italy.  相似文献   

10.
Lead is separated from gram amounts of Zn, In, Ga, Fe(III), Cu(II), Co(II), Mn(II), U(VI), Ca and Ba on a short column of AG1-X4 anion-exchange resin in the bromide form. Lead is retained from 0.2 M hydrobromic acid while the other elements are eluted completely with this reagent. Lead is then eluted with 2 M nitric acid. Separations are sharp and quantitative and, especially for gram amounts of zinc, much better than those obtained with an 8% cross-linked resin; up to 10 mg of lead can be separated from 2 g of zinc. Results are given for synthetic mixtures and lead is determined in several analytical grade chemicals.  相似文献   

11.
Strelow FW  Weinert CH 《Talanta》1973,20(11):1127-1137
U(VI) can be separated from Ga, Fe(III), Bi, Pb, Cd, Zn, Cu(II) and Au(III) by quantitative elution with 0.50M HBr in 86% acetone or with 0.35M HBr in 90% acetone from a column of AG50W-X4 cation-exchange resin of 200-400 mesh particle size. U(VI) and many other ions are retained. U(VI) then can be eluted selectively with 0.50M HCl in 83% acetone or with 0.35M HCl in 85% acetone. Co(II), Mn(II), Mg, Ca, Ti(IV), Al, Zr, Th and La are quantitatively retained by the column. These elements then can be eluted with 5M HNO(3). At the higher acid concentration (0.50M) the separation between U(VI) and Li is not satisfactory but is excellent at the lower acid concentration; the U(VI) peak is sharper at the higher acid concentration. Separations are sharp and quantitative, as is demonstrated by results for some synthetic mixtures. Distribution coefficients and elution curves are presented.  相似文献   

12.
Strelow FE  Wienert CH  van der Walt TN 《Talanta》1974,21(11):1183-1191
Indium can be separated from Zn, Pb(II), Ga, Ca, Be, Mg, Ti(IV), Mn(II), Fe(III), Al, U(VI), Na, Ni(II) and Co(II) by selective elution with 0.50M hydrochloric acid in 30% aqueous acetone from a column of AG50W-X8 cation-exchange resin, all the other elements being retained by the column. Lithium is included in the elements retained by the column when 0.35M hydrochloric acid in 45% aqueous acetone is used for eluting indium, but the elution of indium is slightly retarded. Ba, Sr, Zr, Hf, Th, Sc, Y, La and the lanthanides, Rb and Cs should also be retained according to their distribution coefficients. Cd, Bi(III), Au(III), Pt(IV), Pd(II), Rh(III), Mo(VI) and W(VI) can be eluted with 0.20M hydrobromic acid in 50% aqueous acetone before the elution of indium, and Ir(III), Ir(IV), As(III), As(V), Se(IV), Tl(III), Hg(II), Ge(IV), Sb(III) and Sb(V), though not investigated in detail, should accompany these elements. Relevant distribution coefficients and elution curves and results for analyses of synthetic mixtures of indium with other elements are presented.  相似文献   

13.
Summary The cation-exchange behaviour of Mn(II), Cd(II), Co(II), Ni(II), Zn(II), Cu(II), Fe(III), Sc(III), Y(III), Eu(III), Dy(III), Ho(III), Yb(III), Ti(IV) and Nb(V) in malate media at various concentrations and pH, was studied with Dowex 50 WX8 resin (200–400 mesh) in the ammonium form. Separation of Fe(III)/Cu(II), Fe(III)/Cu(II)/Zn(II), Fe(III)/Co(II)/Mn(II), Cu(II)/Ni(II)/Mn(II), Fe(III)/Cu(II)/Co(II)/Mn(II), Fe(III)/Cu(II)/Ni(II)/Cd(II), Yb(III)/Eu(III), Sc(III)/Y(III),Sc(III)/Yb(III)/Dy(III) and Nb(V)/Yb(III)/Ho(III) has been achieved, among others.This work was supported by C.N.R. of Italy.  相似文献   

14.
Molodovan Z  Vlãdescu L 《Talanta》1996,43(9):1573-1577
Chrome Azurol S (CS) was mobilized on an strongly basic anion-exchange resin (Dowex 2 x 4, in Cl(-) form) by batch equilibration. The modified resin was stable in acetate buffer solution and in 0.1 M HCl and H(2)SO(4), but it was readily degraded with 2-6 M HCl and HNO(3). Retention of Ba(II), Sr(II), Ca(II), Mg(II), Al(III), Cr(III), Zn(II), Fe(III), Ti(IV), Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) was studied using the batch equilibration method. The uptake and recovery yields were determined by using inductively-coupled plasma atomic emission spectroscopy (for Mg, Al, Cr, Ti, Fe, Mn, Ni, Zn, Cu, Cd and Pb) and atomic absorption spectrophotometry (for Ba, Sr, Ca and Co). The optimum pH value was established for performing a selective separation of Al(III) from the other metal ions. The sorption capacities of the CS-loaded resing for Al(III), Cr(III), Mg(II) (at pH 6), Fe(III) (at pH 5) and Ti(IV) (at pH 4) were 14, 2.9, 0.3, 3 and 3.9 mumoles g(-1) respectively. On this basis a method for separating Al(III) from other cations was established.  相似文献   

15.
The lanthanides plus yttrium and scandium are separated from Ba, Sr, Ca, Mg, Pb(II), Bi(III), Zn, Mn(II) and U(VI) by eluting these elements with 2.0 M nitric acid from a column of AG50W-X8 cation exchange resin (200-400 mesh). The lanthanides are retained and can then be eluted with 4 M nitric or hydrochloric acid. Separations are quantitative and applicable to microgram and millimolar amounts of the lanthanides and the other elements. Elements such as Cu(II), Co(II), Ni(II), Cd. Hg(II), T1(I). Ag, Be, Ti(IV) and the alkali metals should accompany barium quantitatively according to their known distribution coefficients. Relevant elution curves and results of analysis of synthetic mixtures are presented.  相似文献   

16.
Khater MM  Korkisch J 《Talanta》1971,18(10):1001-1004
The batch distribution coefficients of Cu(II), Za, Cd, Fe(III), Hg(II), Mg, Co(II), Ni, Pb, Ca and Bi were determined on the strongly acidic cation-exchange resin Dowex 50 x 8 in 0.1M trioctylphosphine oxide in tetrahydrofuran-5% 12M nitric acid. In this mixture all these metal ions, except Bi, have high K(d)-values and can be separated quantitatively from uranium which has a distribution coefficient of 0.1. Mixtures of U with Cu, Ni, Co, Cd or Fe were analysed to test the applicability of such separations. Different titrimetric and spectrophotometric methods were used to determine the elements subsequent to their separation from uranium on ion-exchange columns. The results show that accurate and effective separations can be achieved.  相似文献   

17.
Summary An optimal separation system is presented for the rarer elements Ga(III), In(III), Tl(III) and the main intergrowth elements such as Fe(III), Cu(II), Pb(II), Zn(II) etc., using the cation-exchange column Nucleosil SA and 0.1 mol/l tartrate –0.12% NaCl, pH 2.25, as mobile phase, by means of which complete separations of these metal ions can be obtained within 15 min. Under these chromatographic conditions, the detection sensitivities of these metal ions were compared by post column derivatisation using the reagents PAR, PAR-Zn-EDTA and 5-Br-PADAP [2(5-Bromo-pyridylazo)-5-diethylaminophenol]. The optimum detection system was 1 mmol/l PAR-0.5 mmol/l Zn-EDTA – 2 mol/l NH3, pH 11, with a 6 m reaction coil heated to 60°C and measured at 495 nm.In addition, a technique of pre-column washing was also developed to eliminate matrix effects of sample solutions, and, if necessary, to concentrate ultra trace amounts of metal ions. A procedure is presented for the simultaneous determination of the rarer elements Ga(III) and In(III) in complex ores. Tested by analyses of synthetic and natural samples with contents of 0.004% to 0.1%, this new method shows high selectivity, good precision, simplicity and practicability.  相似文献   

18.
Zusammenfassung Die verhältnismäßig schnell durchführbare Trennung des Calciums und Magnesiums von Mn, Fe, Al und Ti erfolgt durch deren selektive Sorption an dem Iminodiacetatgruppen enthaltenden Kationenaustauscher Dowex A-1 aus alkalischer Lösung, die Triäthanolamin und Citrat enthält. Es erwies sich, daß Mn(III), Fe(III) und Al bei pH>13±0,5 Komplexe bilden, die am Kationit nicht haftenbleiben. Titan verbleibt als Citratkomplex in Lösung. Magnesium wird mit alkoholischer Ammoniumoxalatlösung eluiert, Calcium mit 0,3 N HCl. Die Bestimmung von Ca, Mg und Mn erfolgt komplexometrisch.Entwickelt wurden zwei Varianten der Methode: für die Analyse von Eisenerzen, Manganerzen und Agglomeraten, sowie von Silicaten.
Separation of calcium and magnesium and of both ions from Mn, Fe, Al and Ti using chelate resin, triethanolamine and oxalat
The method is based on the selective sorption of Ca2+ and Mg2+ on a cation-exchange resin with iminodiacetic groups from alkaline solution containing triethanolamine and alkali metal citrates. In solution with pH>13±0.5 Mn(III), Fe(III) and Al(III) form complexes with triethanolamine, which are not sorbed by the cation-exchange resin. Titanum(IV) forms citrate complexes and also remains in the solution. Magnesium is eluted with alcoholic solution of ammonium oxalate, calcium with 0.3 N hydrochloric acid. The determination of calcium and magnesium in the corresponding eluates as well as that of manganese in the solution is carried out complexometrically.Two variants of the method are described: for the analysis of iron ores, manganese ores, agglomerates and for silicates.
  相似文献   

19.
Traces of the specified elements can be separated from 1-g amounts of manganese(II), using a 20-g column of AG50W-X8 cation-exchange resin. The trace elements are separated into four groups and are determined by atomic absorption spectrometry, except titanium, which is determined spectrophotometrically. With the exception of sodium, recoveries for 10 μg amounts vary between 94% (for nickel) and 101% (for magnesium). Relevant elution curves, results for the analysis of synthetic mixtures and for the determination of eight trace elements in samples of manganese metal, manganese chloride and manganese dioxide are presented.  相似文献   

20.
A method is presented for the quantitative separation of the trivalent rare earths plus Sc(III) as a group from Al(III), Ga(III), In(III), Tl(III), Fc(III). Ti(IV), U(VI), Be(II). Mn(II), Co(II), Cu(II), Ni(II). Zn(II). and Cd(II). These elements can be eluted from a cation-exchange column with 1.75 N HCl, while the rare earth group elements are retained. Numerous other elements not investigated have low distribution coefficients in 1.75 N HCl and therefore should be separated by the same procedure; Th(IV) is retained by the column when the rare earths are elutcd with 3.0 N HCl. The only elements which partially accompany the rare earths plus Sc(III) are Zr(IV), Hf(IV), Sr(II), and Ba(II) ; these have to be separated by special procedures. The method is suitable for accurate reference analysis over a wide range of concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号