首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A comparative study of two mathematical approaches was performed in order to correct systematic errors due to the presence of the unexpected interferences which appear when the quantitation of the analyte in real samples is carried out with calibration curves built using standards in pure solvent. These methods consisted in the establishment of different mathematical expressions which transform the concentration (Cs) obtained using calibration graphs built using pure solvent into the corrected concentration (C(M)) that should be obtained if the quantitation is carried out with calibration curves built using standards dissolved in blank matrix extracts. In the two approaches the correction is performed from the results of an intermediate precision study which was carried out using both calibration graphs (prepared using pure solvent and blank matrix extract). By using ANCOVA to compare the slope of both solvent-based and matrix-matched calibration graphs, matrix effect was found in the determination of deltamethrin in tomato and acrinathrin in tomato and pepper. In these cases, both approaches led to good results.  相似文献   

2.
Research papers in different fields of analytics indicate that the effect of matrix-induced chromatographic response enhancement (matrix effect) is a commonly encountered problem in gas chromatography applications. In this paper, an example of the effect of sample matrix on the quantitative determination of total petroleum hydrocarbons (TPH) by GC–FID in soil is presented. Two types of soil were selected for the evaluation. Extraction and analysis of the soil samples was in accordance with CEN prEN 14039. The relative systematic error resulting from the matrix effect was obtained for three different TPH concentrations by statistical comparison of the slopes of the matrix-matched calibration lines and a pure solvent calibration line. Too high TPH concentrations were obtained when conventional solvent calibration was used for quantitation. This demonstrates that matrix-matched calibration should be exploited in the determination of petroleum hydrocarbons in soil samples. However, there was also significant enhancement of the response due to an interfering matrix with decreasing analyte concentration. Enhancement seems to be especially evident in the quantification of TPH over the concentration range encountered in polluted environments. As a result, even when matrix-matched calibration is used for quantitation, it is still necessary to establish the range over which a linear response can be expected. Otherwise too high results for sample TPH concentrations will be obtained.  相似文献   

3.
The aim of this study was to evaluate the applicability of different calibration approaches in a multi- and single-residue analysis of modern pesticides in plant matrices using liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS). In the first set of experiments the determination of eight pesticides representing different groups of polar/unstable pesticides (carbamates, benzimidazoles, azoles, benzoylphenylurea) in apple samples was performed. The trueness and precision of data obtained by using: (i) external solvent standard calibration, (ii) external matrix-matched standard calibration and (iii) echo-peak internal standard calibration was compared. The last mentioned method is a novel technique providing the possibility to inject internal standard of the same identity as a target analyte, so that its retention time is close to the analyte from the sample. According to expectation, when using external standard solvent calibration the results were under- or overestimated due to suppression or enhancement of analyte's signal by matrix components. On the other hand with the use of matrix-matched calibration accurate data were obtained. With echo-peak technique accurate results comparable to those obtained by matrix calibration were obtained for six out of eight pesticides. In the second set of experiment we used the echo-peak technique to overcome the problem with the response instability in the analysis of chlormequat in pear concentrate samples. As an internal standard method the echo-peak technique provided the possibility of monitoring of signal decrease during the analytical sequence and to compensate this decrease by relating sample peak area relatively to this internal standard.  相似文献   

4.
A new methodology is proposed for obtaining analytical results free from bias errors, it is based on a modification of the standard addition method. Bias or systematic errors are taken as the differences between the amounts of analyte in the test portion and the image of the analytical signal on a calibration relationship where the amounts of added analyte act as the predictors. The constant component of the error, the matrix interactive effect and the direct matrix interference are jointly discussed as the main sources of bias. The latter two are considered to be different forms of interference. As an example, the new methodology was applied to the determination of sulphate ion in a magnesium chloride sample (Merck AR) using a spectrophotometric and an atomic absorption spectrophotometric procedure. No direct matrix interference or interactive matrix effect on the analytical results was found.  相似文献   

5.
In this work, a fast thermal methodology is developed for the determination of leachable Cu, Cr, Ni and Pb in sediments by electrothermal atomic absorption spectrometry. Fast thermal programs were tried using hot injection, removal of the ashing stage and matrix modifier and their performance compared with that obtained under conventional thermal programs. For this purpose, the BCR three-stage sequential extraction scheme was applied for partitioning of Pb, Cu, Ni and Cr. CRM BCR 601 lake sediment, which is provided with certified values for the extractable contents of the above metals according this scheme, was used for validation.A shortening of the measurement time by a factor of 3-4 was attained without losing analytical performance. Additionally, other features for speeding up determinations such as calibration are considered. Thus, specifically designed fast thermal programs allowed calibration with matrix-matched standards with extractants to be performed for most metals and fractions instead of standard additions. Background signals, LODs, repeatability and sensitivity were generally similar with both types of programs, hence yielding a comparable analytical performance.  相似文献   

6.
The matrix enhancement effect in gas chromatography (GC) has been a problem for the last decade and results in unexpected high recovery. Most efforts, including the use of different types of injectors/matrix simplification procedures, and further clean-up associated with removing this effect has focused on equalizing the response of the standard in the solvent and matrix. However, after eliminating the matrix enhancement effect, the sensitivity of GC remained unchanged. But, GC sensitivity can be increased by utilizing this matrix effect originating from a matrix-matched standard. Very few studies have highlighted utilizing the matrix effect but have rather advocated eliminating it. Analyte protectants (3-ethoxy-1,2-propanediol, gulonolactone and sorbitol) have been introduced as an alternative for GC–mass spectroscopy (GC–MS) (not examined for other GC detectors), as they equalize the response without removing the matrix effect, and, hence, increase sensitivity. Versatile applications of analyte protectants are not observed in practice. The European guidelines recommend the use of matrix-matched standard calibration for residue measurements. As a result, numerous applications are available for matrix-matched standards that compensate for the matrix effect. Moreover, the matrices (among them pepper leaf matrix) act as a protectant for thermolabile analytes in some cases. A lower detection limit should be achieved to comply with the maximum residue limits. Therefore, the matrix enhancement effect, which is considered a problem, can play an important role in lowering the detection limit by increasing the transfer of analyte from the injection port to the detector.  相似文献   

7.
A multi-residue method has been developed and validated for the simultaneous quantification and confirmation of around 130 multiclass pesticides in orange, nectarine and spinach samples by GC-MS/MS with a triple quadrupole analyzer. Compounds have been selected from different chemical families including insecticides, herbicides, fungicides and acaricides. Three isotopically labeled standards have been used as surrogates in order to improve accurate quantitation. Samples were extracted by using accelerated solvent extraction (ASE) with ethyl acetate. In the case of spinach, an additional clean-up step by gel permeation chromatography was applied. Determination was performed by GC-MS/MS in electron ionization mode acquiring two MS/MS transitions for each analyte. The intensity ratio between quantitation transition (Q) and identification transition (q) was used as confirmatory parameter (Q/q ratio). Accuracy and precision were evaluated by means of recovery experiments in orange, nectarine, and spinach samples spiked at two concentration levels (0.01 and 0.05 mg/kg). Recoveries were, in most cases, between 70% and 120% and RSD were below 20%. The limits of quantification objective for which the method was satisfactorily validated in the three samples matrices were for most pesticides 0.01 mg/kg. Matrix effects over the GC-MS/MS determination were tested by comparison of reference standards in pure solvent with matrix-matched standards of each matrix. Data obtained showed enhancement of signal for the majority of analytes in the three matrices investigated. Consequently, in order to reduce the systematic error due to this effect, quantification was performed using matrix-matched standard calibration curves. The matrix effect study was extended to other food matrices such as raisin, paprika, cabbage, pear, rice, legume, and gherkin, showing in all cases a similar signal enhancement effect.  相似文献   

8.
The assessment of matrix effects in the quantification of organophosphorus pesticides in fruit and vegetables by GC-NPD, were studied applying ANCOVA. Calibration curves prepared in solvent were compared with calibration curves prepared in a blank matrix extract for eight different commodities, establishing whether the matrix induces systematic or proportional errors in the quantification of the pesticides. In such cases correction functions were obtained and validated by quantifying spiked samples using solvent calibrations and applying the correction functions to the data obtained. The results were compared with those obtained by quantification using matrix-matching calibrations and with those from 100% recovery experiments. It was found that the matrix effects can be avoided using the correction functions. Finally the contribution of the correction functions to the uncertainty of the results was estimated as well as their stability during a four month period.  相似文献   

9.
In this study, suitability of fast gas chromatography-mass spectrometry (GC-MS) on a narrow-bore column with a programmed temperature vaporizer for the analysis of pesticide residues in non-fatty food was evaluated. The main objectives were ruggedness and stability of chromatographic system with regards to co-extractives injected. The chromatographic matrix induced response enhancement was found to be strongly dependent on the concentration of residues and is reaching up to 700% compared to the pesticides solutions in a neat solvent. However, the responses of pesticides in matrix-matched standards at different concentration levels do not significantly change during 130 injections. Response enhancement/or decrease is influenced by the sample preparation technique. External calibration with matrix-matched calibration standards should, therefore, provide results with good precision also at the concentration level of 0.005 mg kg(-1). Special attention is given to the performance of the chromatographic column and retention gap with regards to peak widths, peak tailing and different sample preparation methods. During approximately 460 matrix sample injections, the performance of the analytical column was acceptable. GC-MS set-up with 0.15 mm i.d. column can be successfully utilized for the pesticide residues analysis.  相似文献   

10.
Matrix-matched calibration allows to quantify accurately without the necessity of correcting results for the bias error caused by matrix effects. In this work, an approach to estimate the decision limit CCα and the detection capability CCβ using matrix-matched calibration data series that were obtained at different times and under different conditions is described. The basic idea underlying the approach is to consider the set of the calibration submodels to be an ensemble of equally probable events. By way of illustration, the methodology is applied to a data set acquired within a validation study of an LC–MS assay for the determination of the aminoglycoside antibiotic dihydrostreptomycin in kidney.  相似文献   

11.
This work presents a new methodology to quantify ethyl carbamate (EC) in fortified wines. The presented approach combines the microextraction by packed sorbent (MEPS), using a hand-held automated analytical syringe, with one-dimensional gas chromatography coupled with mass spectrometry detection (GC–MS). The performance of different MEPS sorbent materials was tested, namely SIL, C2, C8, C18, and M1. Also, several extraction solvents and the matrix effect were evaluated. Experimental data showed that C8 and dichloromethane were the best sorbent/solvent pair to extract EC. Concerning solvent and sample volumes optimization used in MEPS extraction an experimental design (DoE) was carried out. The best extraction yield was achieved passing 300 μL of sample and 100 μL of dichloromethane. The method validation was performed using a matrix-matched calibration using both sweet and dry fortified wines, to minimize the matrix effect. The proposed methodology presented good linearity (R2 = 0.9999) and high sensitivity, with quite low limits of detection (LOD) and quantification (LOQ), 1.5 μg L−1 and 4.5 μg L−1, respectively. The recoveries varied between 97% and 106%, while the method precision (repeatability and reproducibility) was lower than 7%. The applicability of the methodology was confirmed through the analysis of 16 fortified wines, with values ranging between 7.3 and 206 μg L−1. All chromatograms showed good peak resolution, confirming its selectivity. The developed MEPS/GC–MS methodology arises as an important tool to quantify EC in fortified wines, combining efficiency and effectiveness, with simpler, faster and affordable analytical procedures that provide great sensitivity without using sophisticated and expensive equipment.  相似文献   

12.
Membrane-assisted solvent extraction coupled to large volume injection in a programmable temperature vaporisation injector using gas chromatography–mass spectrometry analysis was optimised for the simultaneous determination of a variety of endocrine disrupting compounds in environmental water samples (estuarine, river and wastewater). Among the analytes studied, certain hormones, alkylphenols and bisphenol A were included. The nature of membranes, extraction solvent, extraction temperature, solvent volume, extraction time, ionic strength and methanol addition were evaluated during the optimisation of the extraction. Matrix effects during the extraction step were studied in different environmental water samples: estuarine water, river water and wastewater (influent and effluent). Strong matrix effects were observed for most of the compounds in influent and effluent samples. Different approaches were studied in order to correct or minimise matrix effects, which included the use of deuterated analogues, matrix-matched calibration, standard addition calibration, dilution of the sample and clean-up of the extract using solid-phase extraction (SPE). The use of deuterated analogues corrected satisfactorily matrix effect for estuarine and effluent samples for most of the compounds. However, in the case of influent samples, standard addition calibration and dilution of the sample were the best approaches. The SPE clean-up provided similar recoveries to those obtained after correction with the corresponding deuterated analogue but better chromatographic signal was obtained in the case of effluent samples. Method detection limits in the 5–54 ng L−1 range and precision, calculated as relative standard deviation, in the 2–25% range were obtained.  相似文献   

13.
One of the quantification methods frequently applied to pesticide residue analysis in food by liquid chromatography — mass spectrometry (LC-MS) involves matrix-matched calibrations with a representative matrix used for all commodities belonging to one group. This approach, although very practical, is deemed to generate analytical errors. The effect of the application of a representative-matrix calibration curve on the pesticide quantification result was examined. Extractions of 56 pesticides from five soft fruits (strawberries, blackberries, raspberries, black currant and red currant) were carried out using QuEChERS method. Pesticide determinations were performed by LC-MS/MS in multiple reaction monitoring mode. Quantification difference functions and parameters were proposed and calculated. At the concentration of 0.05 mg kg?1 for ca. 90% of examined pesticides the quantification difference arising from the use of a representative matrix calibration curve (raspberries) instead of a specific fruit matrix calibration curve was below 20% for black and red currents, and below 30% and 35% in the case of strawberries and blackberries, respectively. The 25% difference limit was not exceeded for 51 pesticides in black and red currents, 46 pesticides in blackberries and 45 pesticides in strawberries. Quantification difference functions and parameters such as relative standard deviation of corrected process efficiencies were found to be helpful in data-driven decision-making on the applicability of a representative matrix; the former may be also used as a tool for data correction to ensure the reliability and accuracy of analyses.   相似文献   

14.
A new analytical method for the simultaneous determination of 90 pesticides in fruit juices by ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) has been developed and validated. Extraction was performed with acetonitrile, applying QuEChERS methodology, and the extracts were analyzed without any further clean-up step, providing better results than solid phase extraction (SPE) procedure. Before chromatographic step, extracts were diluted with water (1:1) in order to obtain good peak shapes. Several chromatographic conditions were evaluated in order to achieve a fast separation in Multiple Reaction Monitoring (MRM) mode, obtaining a run time of only 11 min. Matrix effect was studied for different types of fruit juices (peach, orange, pineapple, apple and multifruit), indicating that multifruit juice can be selected as representative matrix for routine analysis of these food commodities. Pesticides were quantified using matrix-matched calibration with recoveries between 70.4 and 108.5% and relative standard deviation lower than 20%. Limits of quantification were lower than 5 microg L(-1) in all the cases. The developed procedure was applied to commercial fruit juices, detecting carbendazim, cyprodinil and thiabendazol in a few samples.  相似文献   

15.
The use of the recovery term has presented some confusion in Analytical Chemistry. Recent IUPAC recommendations propose to distinguish between two terms: recovery or recovery factor, ℜ, and apparent recovery, ℜ*. Apparent recovery includes recovery factor and a new recovery term proposed in this paper, named calibration recovery, ℜC, which depends of the type of systematic error due to the matrix effect (constant and/or proportional) and is related to the applied calibration methodology. This paper highlights the dependence of the calibration recovery on the sample analyte concentration and, for extension, of the apparent recovery, defines the recovery profile, and makes evident the need to determine a “fit for purpose” analyte concentration interval to comply with a regulated recovery requirements. An approach to estimate the calibration recovery and its associated uncertainty in relation to the above-mentioned dependence is presented. The usefulness of the proposed methodology has been shown in the quantification of a pesticide by GC-ECD for assessing dermal exposure.  相似文献   

16.
A rapid method has been devised for the direct determination of chlormequat in tomato samples. No clean-up is required, and analysis uses ion-exchange liquid chromatography/tandem mass spectrometry interfaced with electrospray ionization (LC/ESI-MS/MS). A cation-exchange column was used with an aqueous ammonium acetate/acetonitrile mixture as the mobile phase under isocratic conditions. The method was validated in terms of detection limits (LOD), quantitation limits (LOQ), linearity, recovery, precision and accuracy. Good results in the low micro g kg(-1) level were obtained for the LOD and LOQ of chlormequat in tomato samples. Comparison of solvent and matrix-matched calibration curves demonstrated the absence of significant matrix effects and the feasibility of using external calibration. Linearity was established over two orders of magnitude by performing homoscedasticity and Mandel fitting statistical tests. The absence of both constant and proportional systematic errors was verified by evaluating the recovery function, demonstrating good method accuracy. Excellent precision in terms of intra-day repeatability was calculated (RSD% <3.4). Extraction recoveries from tomato products were calculated, by using a labelled internal standard (d(4)-chlormequat), to be in the 93 +/- 5-99 +/- 7% range. The applicability of the method to the determination of chlormequat residues in tomato products was demonstrated.  相似文献   

17.
The multivariate effects of Na, K, Mg and Ca as nitrates on the electrothermal atomisation of manganese, cadmium and iron were studied by multiple linear regression modelling. Since the models proved to efficiently predict the effects of the considered matrix elements in a wide range of concentrations, they were applied to correct the interferences occurring in the determination of trace elements in seawater after pre-concentration of the analytes. In order to obtain a statistically significant number of samples, a large volume of the certified seawater reference materials CASS-3 and NASS-3 was treated with Chelex-100 resin; then, the chelating resin was separated from the solution, divided into several sub-samples, each of them was eluted with nitric acid and analysed by electrothermal atomic absorption spectrometry (for trace element determinations) and inductively coupled plasma optical emission spectrometry (for matrix element determinations). To minimise any other systematic error besides that due to matrix effects, accuracy of the pre-concentration step and contamination levels of the procedure were checked by inductively coupled plasma mass spectrometric measurements. Analytical results obtained by applying the multiple linear regression models were compared with those obtained with other calibration methods, such as external calibration using acid-based standards, external calibration using matrix-matched standards and the analyte addition technique. Empirical models proved to efficiently reduce interferences occurring in the analysis of real samples, allowing an improvement of accuracy better than for other calibration methods.  相似文献   

18.
A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon >2.3%) and LS (organic carbon <2.3%). The method was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrix-matched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70-120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg(-1) and from 11.41 to 79.23 μg kg(-1), respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg(-1) and the limits of quantification from 20.37 to 49.27 μg kg(-1) . In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg(-1) ) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.  相似文献   

19.
We propose a mathematical model from an analytical application viewpoint inspired in the limit dilution method. The theoretical development of the model and its results are given. The model shows that there is a linear relation between the inverse of fluorescence intensity and the inverse of the dilution factor; each analytic system (sample, diluent and analyte) is characterised by a general linear function which is easily obtained. The analytical applications arising from this linearity are of great importance in X-ray fluorescence analysis. The following immediate applications are proposed: direct procurement of the total correction factor Y/H, rapid calculation of the fluorescence intensity of the analyte in a sample (Iis) and direct calculation of the corrected fluorescence intensity (IisF). The suggested model makes it possible to deduce a linear function between the fluorescence intensity of the analyte and the analyte concentration in successive dilutions of a standard; this straight line behaves as a calibration curve with direct application in X-ray fluorescence analysis. The proposed model may be applied to complex samples of geological origin, with elimination of the matrix effect. The results obtained in the determination of Ca, K, Fe and Ti in a standard soil show complete agreement with the certified reference values with a relative error about 0.5%, even using a standard shale with very different chemical composition as reference sample.  相似文献   

20.
In the present study a second-order calibration strategy for high performance liquid chromatography with diode-array detection (HPLC-DAD) has been developed using parallel factor analysis (PARAFAC) and has been applied for simultaneous determination of aflatoxins B1, B2, G1 and G2 in pistachio nuts in the presence of matrix interferences. Sample preparation was based on solvent extraction (SE) followed by solid phase extraction (SPE) on Bond Elut C18 cartridges. Since the sample preparation procedure was not selective to the analytes of interest, exploiting second-order advantage to obtain concentrations of individual analytes in the presence of uncalibrated interfering compounds seemed necessary. Appropriate pre-processing steps have been applied to correct background signals and the effect of retention time shifts. Transferred calibration data set obtained from standardization of solvent based calibration data has been used in prediction step. The results of PARAFAC on a set of spiked and naturally contaminated pistachio nuts indicated that the four aflatoxins could be successfully determined. The method was validated and multivariate analytical figures of merit were calculated. The advantages of the proposed method are using a low-cost SPE step relative to standard method of aflatoxin analysis (immune affinity column assay), a unique and simple isocratic elution program for all samples and a calibration transfer for saving both chemicals and time of analysis. This study show that coupling of SPE-HPLC-DAD with PARAFAC as a powerful second-order calibration method can be considered as an alternative method for resolution and quantification of aflatoxins in the presence of unknown interferences obtained through analysis of highly complex matrix of pistachio samples and cost per analysis can be reduced significantly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号