首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Yasunari Monguchi 《Tetrahedron》2006,62(35):8384-8392
The catalytic degradation method of p,p′-DDT [1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane] and its regioisomer o,p′-DDT [1,1,1-trichloro-2-(o-chlorophenyl)-2-(p-chlorophenyl)ethane] using the Pd/C-Et3N system under ambient hydrogen pressure and temperature was established. The presence of Et3N was necessary for the quick and complete breakdown of DDT. The independent degradation study of two intermediates, p,p′-DDD [2,2-bis(p-chlorophenyl)-1,1-dichloroethane] and p,p′-DDE [2,2-bis(p-chlorophenyl)-1,1-dichloroethylene] using GC-MS let us to speculate the degradation pathway of p,p′-DDT. In the initial phase of the reaction, p,p′-DDT degradation splits into two ways: a dehydrochlorination pathway and a hydrodechlorination pathway. In each pathway, reaction starts from an aliphatic moiety and subsequent hydrodechlorination from the benzene moieties takes place in a stepwise manner. The former pathway leads to the formation of 1,1-diphenylethane and the latter leads to the formation of 1,1-dichloro-2,2-diphenylethane. These diphenylethane analogs, which are less toxic compared with p,p′-DDT, are terminal degradation products in our system. The distinctive features of our catalytic degradation method of DDTs are reliability, simplicity, efficiency, and inexpensiveness.  相似文献   

2.
Dong C  Zeng Z  Li X 《Talanta》2005,66(3):721-727
A novel laboratory-made sol-gel calix[4]arene/hydroxy-terminated silicone oil coated fiber has been applied for headspace solid-phase microextraction (HS-SPME) combined with gas chromatography (GC) with electron capture detection (ECD) to determine 12 organochlorine pesticides (OCPs) and their metabolites in radish sample. The analytes in the study consisted of α-, β-, γ- and δ-hexachlorocyclohexane (BHC), 1,1,1-trichloro-2-(2-chlorophenyl)-2-(4-chlorophenyl)ethane (o,p′-DDT), 1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane (p,p′-DDT), 2,4-dichlorobenzophenone (o,p′-DBP), 4,4-dichlorobenzophenone (p,p′-DBP), 1,1-dichloro-2,2-bis(4-chlorophenyl)ethylene (p,p′-DDE), bis(4-chlorophenyl)methane (p,p′-DDM), 1,1-dichloro-2,2-bis(4-chlorophenyl)ethane (p,p′-DDD) and endrin. The following parameters were adjusted to optimize HS-SPME in order to obtain the maximum sensitivity: extraction temperature, extraction time, the addition of salt, desorption temperature and time. Especially, the effect of the complex radish matrix on quantitative extraction of pesticides was discussed in detail. Detection limits of the developed method for radish matrices were below 174 ng/kg for all pesticides. Relative standard deviations for quintuplicate analyses of radish samples fortified each analytes were not higher than 13.1%. The results demonstrate the suitability of the HS-SPME/GC-ECD approach for the analysis of multi-residue OCPs and metabolites in radish.  相似文献   

3.
Zhou YY  Wang SW  Kim KN  Li JH  Yan XP 《Talanta》2006,69(4):970-975
Dichlorodiphenyltrichloroethane (DDT) and its metabolites are a typical kind of persistent organic pollutants (POPs). Development of a simple, cost-effective and sensitive methodology to monitor DDTs concentrations in water environment is of particular significance for understanding the fate and behavior of these pollutants. In this paper, a method on the basis of solid-phase extraction (SPE) using expanded graphite (EG) as sorbent coupled on-line with high performance liquid chromatography (HPLC) was developed for the determination of trace levels of p,p′-DDD (2,2-bis(4-chlorophenyl)-1,1-dichloroethane), p,p′-DDT, o,p′-DDT and p,p′-DDE (2,2-bis(4-chlorophenyl)-1,1-dichloroethene) in water. The analytes in water were preconcentrated onto the SPE column packed with expanded graphite, and subsequently eluted with methanol-water (90:10) mixed solvent. HPLC with a photodiode array detector was used for their separation and detection. The developed on-line solid-phase extraction protocol for HPLC permits the current HPLC separation and the next preconcentration proceeded in parallel, and thus allows one determination within 8 min. The precision (R.S.D.) for 10 replicate injections of a mixture of 1 μg l−1 of each analyte was 3.2-6.2% for the peak area measurement. The detection limits (S/N = 3) for preconcentrating 50 ml of sample solution ranged from 10 to 25 ng l−1 at a sample throughput of 7.5 samples h−1. The enhancement factors were about 700. The method was applied to the determination of trace p,p′-DDD, p,p′-DDT, o,p′-DDT and p,p′-DDE in local lake, river and tap water samples.  相似文献   

4.
A simple and fast method is presented to be used for example in studies on the relationship between serum levels of persistent organic pollutants and type 2 diabetes mellitus. Method is based on liquid–liquid extraction and gas chromatography coupled with high-resolution mass spectrometry. In the sample pre-treatment special attention was paid to minimize the number of sample manipulation steps and the amounts of organic solvents needed. Compounds analyzed were 2,2′,4,4′,5,5′-hexachlorobiphenyl (PCB-153) and 1,1-dichloro-2,2-bis (p-chlorophenyl)-ethylene (p,p′-DDE), the major metabolite of DDT. The method included extraction and cleanup of 0.2 ml of serum in a single test tube and subsequent analysis of the extract from 0.2 ml final volume. Validation was conducted to explore the performance of the method. The limits of detection for p,p′-DDE and PCB-153 based on the standard deviation of the blank samples were 4.3 and 3.1 pg/ml, respectively. Repeatability was less than 2.5% at three concentration levels tested and recovery from Certified Reference Material SRM 1589a was 84% for p,p′-DDE and 87% for PCB-153 of the certified values, respectively. Serum samples from the AMAP intercalibration round 2008-2 were also analyzed, and results were 101–116% of the assigned values. The presented method was used for an epidemiological study with more than 700 serum samples from a type 2 diabetes cohort from Sweden.  相似文献   

5.
The organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control in certain areas of South Africa. The strict Stockholm Convention on Persistent Organic Pollutants (POPs) allows spraying on the inside of traditional dwellings with DDT. In rural villages contaminated dust presents an additional pathway for exposure to DDT. We present a new method for the determination of DDT in indoor air where separate vapour and particulate samples are collected in a single step with a denuder configuration of a multi-channel open tubular silicone rubber (polydimethylsiloxane (PDMS)) trap combined with a micro quartz fibre filter. The multi-channel PDMS trap section of the denuder concentrates vapour phase insecticide whereas particle associated insecticide is transferred downstream where it is collected on a micro-fibre filter followed by a second multi-channel PDMS trap to capture the blow-off from the filter. The multi-channel PDMS trap and filter combination are designed to fit a commercial thermal desorber for direct introduction of samples into a GC–MS. The technique is solvent-free. Analyte extraction and sample clean-up is not required. Two fractions, vapour phase and particulate phase p,p′-DDT, o,p′-DDT; p,p′-DDD, o,p′-DDD; p,p′-DDE and o,p′-DDE in 4 L contaminated indoor air, were each quantitatively analysed by GC–MS using isotopically labelled ring substituted 13C12p,p′-DDT as an internal standard. Limits of detection were 0.07–0.35 ng m−3 for p,p′-DDT, o,p′-DDT, p,p′-DDD, o,p′-DDD, p,p′-DDE and o,p′-DDE. Ratios of airborne p,p′-DDD/p,p′-DDT and of o,p′-DDT/p,p′-DDT are unusual and do not match the ideal certified ingredient composition required of commercial DDT. Results suggest that the DDT products used for indoor residual spraying (IRS) prior to, and during 2007, may have been compromised with regards to insecticidal efficacy, demonstrating the power of this new environmental forensics tool.  相似文献   

6.
This report highlights the characteristics of a general method of performing non-competitive immunoassays for low-molecular-mass analytes, which was developed and applied to 1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane (DDT) determination in aqueous samples. The method is based on the separation of the analyte-bound antibody from the excess of the free antibody by a chromatographic step, followed by the dissociation of the complex and the capture of the previously bound antibody on a solid phase. The measured signal is linearly correlated to the concentration of the complex and, consequently, to the analyte concentration. The 3σ limit of detection (LOD, 8 ng l−1) obtained by the above method enabled us to decidedly improve the sensitivity of the corresponding enzyme-linked immunosorbant assay (ELISA) and of all reported immunoassays for DDT.In addition, by applying this new format, even if a very selective antibody was used, a broad selectivity was observed, which allowed DDT + DDD + DDE to be determined instead of only p,p′-DDT as in the ELISA performed with the same antibody. In addition, real water samples were validated in a percentage recovery test. Very good recovery rates were obtained, highlighting the validity of the proposed method to accurately determine the total DDT content in water.  相似文献   

7.
Certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing CRMs of organic calibration solutions since 2003, and has issued several NMIJ CRMs. The development of these materials was conducted at the NMIJ in cooperation with candidate material producers. The freezing-point depression method was principally adopted for assessment of the purity of starting materials to give reliable certified values. Gas chromatography with flame ionization detection (GC–FID) and/or high-performance liquid chromatography (HPLC), which are based on independent principles and whose levels of accuracy are well evaluated, were applied in combination with other methods to avoid any possible analytical bias. Purity assessment is outlined for two typical examples, 1,1-dichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDD) and 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDT), which were used as starting materials for a CRM under development. Methods adopted for gravimetric preparation and ampouling of solutions were qualified and optimized to reduce the uncertainties of certified values due to these factors. Furthermore, a new experimental scheme for assessment of stability and preparation variation is proposed for the proper estimation of uncertainties. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

8.
In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p′-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p′-DDT and its chiral degradation product, o,p′-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC × GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p′-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p′-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC–TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p′-isomers from the complex sample chromatogram, 1D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p′-DDT and o,p′-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by 1D GC–TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC × GC–TOFMS using the same enantioselective column, this time as the first dimension of separation.  相似文献   

9.
A correlation between the electronic structure and biological activity of chosen dichlorodiphenyltrichloroethane (DDT)-type insecticides: 1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane, 1,1-dichloro-2,2-bis(4-chlorophenyl)ethane, 2,2-bis(p-chlorophenyl)-1,1-dichloroethylene, 2,2-bis(4-chlorophenyl)ethanoic acid and 4,4'-dichlorobenzophenone (used in agriculture) has been analysed on the basis of the (35)Cl-nuclear quadrupole resonance (NQR) spectroscopy. The (35)Cl-NQR resonance frequencies measured at 77 K have been correlated with the lethal dose (LD(50)) parameter that characterises the biological activity of these insecticides.  相似文献   

10.
In the current paper we describe a novel sample preparation technique termed dispersive liquid-phase microextraction for the preconcentration and determination of 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its degradation products in water samples that includes 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene(2,4′-DDE), 1,1-dichloro-2,2-bis(4-chlorophenyl)ethane(4,4′-DDE) and 1,1,1-trichloro-2-(2-chlorophenyl)-2-(4-chlorophenyl)ethane (2,4′-DDT) coupled with gas chromatography mass spectrometry (GC-MS), in which a new ionic liquid 1,3-diisooctylimidazolium hexafluorophosphate abbreviated as [D(i-C8)IM][PF6] was used as extraction solvent. For each one extraction, 1.00 mL of the methanol solution containing 40 µL of the ionic liquid was sprayed into 25.00 mL of water sample. In the meantime the ionic liquid was finely dispersed into the aqueous phase and analytes were rapidly migrated into the ionic liquid. After the solution was centrifuged for 2 min at 5000 rpm, the droplets of the ionic liquid are subsided in the bottom of the conical test tube (30.0 ± 0.2 µL). Moreover, the factors relevant to extraction efficiencies were investigated and optimised including the volume of the ionic liquid, disperser solvent, extraction time, sample pH and ionic strength. Under optimal conditions, the enrichment factors of the extraction were between 550 and 725 with an extraction efficiency ranging from 66% to 87% for each different analyte. Finally, 1.0 µL of the ionic liquid collected from above extraction was injected into the injector block of GC-MS instrument for analysis. The detection limit (S/N = 3), the relative standard deviations for 2.0 µg L?1 of the standard analyte (n = 5) and linearity in a calibration range were found to be 3–8 ng L?1, 1.0–2.7% and 10–3000 ng L?1, respectively. Good spiked recoveries over the range of 92.0–13.5% were obtained. The proposed method offers the advantages of simplicity of operation, rapidity, good extraction efficiency and enrichment factor; it has been successfully applied to determination of dicofol and its degradation products in environmental water samples.  相似文献   

11.
A very selective polyclonal antiserum against 1,1,1-trichloro-2,2-bis-(4-chlorophenyl)-ethane (p,p′-DDT) was obtained by a careful choice of the haptenic structure (2,2-bis(4-chlorophenyl)-ethanol hemisuccinate). This hapten was conjugated to BSA to prepare the immunogen. The effects of different types of solid phases on the equilibrium reaction between the hapten on solid phase and the polyclonal antiserum were evaluated to obtain a fine tuning of the antiserum performances in terms of specificity for p,p′-DDT and sensitivity to low levels of this pesticide. The calibration curves obtained show that it is possible to set up a sensitive assay for p,p′-DDT, employing a p,p′-dichlorodiphenylacetic acid-based solid phase, with a detection limit of 0.12 ng/mL and a working range of about 0.21–40 ng/mL. Selectivity towards several p,p′-DDT-related substances was good (o,p-DDT 17%, p,p′-DDD 1.2% o,p-DDD 6.3%, p,p′-DDE 6.7%).  相似文献   

12.
Pressurised liquid extraction (PLE) was used to extract DDT [1,1,1,-trichloro-2,2-bis(p-chlorophenyl)ethane] and its metabolites, DDD [1,1-dichloro-2,2-bis(p-chlorophenyl)ethane] and DDE [1,1-dichloro-2,2-bis(p-chlorophenyl)ethylene] from an aged, contaminated soil. Using three sequential static phases, PLE removed an equivalent quantity of DDT and its metabolites as Soxhlet extraction, in less time and with less solvent. Recovery was almost quantitative, implying appropriate sample work-up and manipulation.  相似文献   

13.
Tetrabromobisphenol A is the most widely used brominated flame retardant. A sensitive and selective enzyme-linked immunosorbent assay (ELISA) for the detection of tetrabromobisphenol A was developed. The limit of detection and the inhibition half-maximum concentration of tetrabromobisphenol A in phosphate buffered saline with 10% methanol were 0.05 and 0.87 ng mL−1, respectively. Cross-reactivity values of the ELISA with a set of important brominated flame retardants including tetrabromobisphenol A-bis(2,3-dibromopropylether), 2,2′,6,6′-tetrabromobisphenol A diallyl ether, hexabromocyclododecane, 1,2-bis(pentabromodiphenyl) ethane, 1,2-bis(2,4,6 tribromophenoxy) ethane, bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate, 2-ethylhexyl-2,3,4,5-tetrabromobenzoate, and polybrominated diphenyl ethers were <0.05%. Concentrations of tetrabromobisphenol A determined by ELISA in the soils from farmlands, the soils from an e-waste recycling site, and the sediments of a canal were in the range of non-detectable–5.6 ng g−1, 26–104 ng g−1 and 0.3–22 ng g−1 dw, respectively, indicating the ubiquitous pollution of tetrabromobisphenol A. The results of this assay for 16 real world samples agreed well with those of the liquid chromatography–tandem mass spectrometry method, indicating this ELISA is suitable for screening of tetrabromobisphenol A in environmental matrices.  相似文献   

14.
Racemic 2,2′-bis[diarylstibano]-1,1′-binaphthyls [(±)-BINASbs] and 2,2′-bis[di(p-tolyl)bismuthano]-1,1′-binaphthyl [(±)-BINABi], which are the antimony and bismuth congeners of BINAP, have been prepared from 2,2′-dibromo-1,1′-binaphthyl (DBBN) via 2,2′-dilithio-1,1′-binaphthyl intermediate by treatment with the appropriate metal halides [(p-Tol)2SbBr, Ph2SbBr and (p-Tol)2BiCl]. The optical resolution of the (±)-BINASbs could be achieved via the separation of a mixture of the diastereomeric Pd-complexes derived from the reaction of (±)-BINASbs with di-μ-chlorobis{(S)-2-[1-(dimethylamino)-ethyl]phenyl-C1,N}dipalladium(II). Optically active (R)-BINASb and (R)-BINABi could be also obtained from optically active (R)-DBBN by the same procedure. The enantiopure BINASbs have been shown to be effective chiral ligands for the rhodium-catalyzed asymmetric hydrosilylation of ketones.  相似文献   

15.
A novel technique, high temperature headspace liquid-phase microextraction (HS-LPME) with room temperature ionic liquid (RTIL), 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as extractant, was developed for the analysis of dichlorodiphenyltrichloroethane (p,p′-DDT and o,p′-DDT) and its metabolites including 4,4′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 4,4′-dichlorodiphenyldichloroethane (p,p′-DDD) in water samples by high performance liquid chromatography with ultraviolet detection. The parameters such as salt content, sample pH and temperature, stirring rate, extraction time, microdrop volume, and sample volume, were found to have significant influence on the HS-LPME. The conditions optimized for extraction of target compounds were as follows: 35% NaCl (w/v), neutral pH condition, 70 °C, 800 rpm, 30 min, 10 μL [C4MIM][PF6], and 25 mL sample solutions. Under the optimized conditions, the linear range, detection limit (S/N = 3), and precision (R.S.D., n = 6) were 0.3-30 μg L−1, 0.07 μg L−1, and 8.0% for p,p′-DDD, 0.3-30 μg L−1, 0.08 μg L−1, and 7.1% for p,p′-DDT, 0.3-30 μg L−1, 0.08 μg L−1, and 7.2% for o,p′-DDT, and 0.2-30 μg L−1, 0.05 μg L−1, and 6.8% for p,p′-DDE, respectively. Water samples including tap water, well water, snow water, reservoir water, and wastewater were analyzed by the proposed procedure and the recoveries at 5 μg L−1 spiked level were in the range of 86.8-102.6%.  相似文献   

16.
TiO(2) nanotubes, novel nanomaterials synthesized from hydrothermal treatment, were investigated for being used as a new solid-phase extraction adsorbent with o,p'-DDT, [1,1,1-trichloro-2-(o-chlorophenyl)-2-(p-chlorophenyl)ethane, p,p'-DDT, [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] and its principle metabolites p,p'-DDD, [1,1-dichloro-2,2-bis(4-chlorophenyl)ethane] and p,p'-DDE [1,1-(2,2-dichloro-ethanylidene)-bis(4-chlorobenzene)] as the target analytes. Several factors such as eluant and its volume, the sample pH, sample volume and the flow rate of samples, were optimized. The effect of humic acid, which is often present in natural water system, was also investigated. Under the optimal conditions, lower detection limits of 0.0031, 0.0037, 0.0053 and 0.0025 ng mL(-1) for p,p'-DDD, p,p'-DDT, o,p'-DDT and p,p'-DDE, respectively, were obtained. The proposed method was successfully applied to the analysis of the target compounds in several environmental water samples. Good recoveries over the range of 81.2-115% were obtained. These results indicated that titanium nanotubes had enormous potential in environmental field as a novel SPE adsorbent material.  相似文献   

17.
A procedure based on QuEChERS extraction and a simultaneous liquid–liquid partition clean-up was developed. The procedure involved extraction of hydrated soil samples using acetonitrile and clean-up by liquid–liquid partition into n-hexane. The hexane extracts produced were clean and suitable for determination using gas chromatography–tandem mass spectrometry (GC–MS/MS). The method was validated by analysis of soil samples, spiked at five levels between 1 and 200 μg kg−1. The recovery values were generally between 70 and 100% and the relative standard deviation values (%RSDs) were at or below 20%. The procedure was validated for determination of 19 organochlorine (OC) pesticides. These were hexachlorobenzene (HCB), α-HCH, β-HCH, γ-HCH, heptachlor, heptachlor epoxide (trans), aldrin, dieldrin, chlordane (trans), chlordane (cis), oxychlordane, α-endosulfan, β-endosulfan, endosulfan sulfate, endrin, p,p′-DDT, o,p′-DDT, p,p′-DDD and p,p′-DDE. The method achieved low limits of detection (LOD; typically 0.3 μg kg−1) and low limits of quantification (LOQ; typically 1.0 μg kg−1). The method performance was also assessed using five fortified soil samples with different physico-chemical properties and the method performance was consistent for the different types of soil samples. The proposed method was compared with an established procedure based on Soxtec extraction. This comparison was carried out using six soil samples collected from regions of Pakistan with a history of intensive pesticide use. The results of this comparison showed that the two procedures produced results with good agreement. The proposed method produced cleaner extracts and therefore led to lower limits of quantification. The proposed method was less time consuming and safer to use. The six samples tested during this comparison showed that soils from cotton growing regions contained a number of persistent OC residues at relatively low levels (<10 μg kg−1). These residues were α-HCH, γ-HCH, heptachlor, chlordane (trans), p,p′-DDT, o,p′-DDT, p,p′-DDD, p,p′-DDE, β-endosulfan and endosulfan sulfate.  相似文献   

18.
An approach to the synthesis of hydroxyl-terminated polymethylphenylsiloxane (PMPS-OH) was proposed and the synthesized PMPS-OH was successfully applied as a precursor to prepare a novel coating for solid-phase microextraction (SPME) via the sol-gel process. The thickness and length of the prepared coating was 70 μm and 1.5 cm, respectively. The extraction efficiency of the PMPS-coated fiber for selected pesticides was higher than that of commercial fibers including 100 μm polydimethylsiloxane (PDMS), 85 μm polyacrylate (PA) and 65 μm polydimethylsiloxane/divinylbenzene (PDMS/DVB). The influence of the extraction process, extraction temperature, extraction time, stirring rate, ionic strength, GC inlet conditions, desorption temperature and time for PMPS-coated fiber application was studied and optimized. Several experiments were carried out to evaluate the analytical characteristics of the proposed SPME-GC-ECD method under optimized conditions. The linearity was from 0.5 to 100 ng g−1 for p,p′-DDE, p,p′-DDD and bifenthrin, and from 2 to 100 ng g−1 for o,p′-DDT, p,p′-DDT, fenpropathrin, beta-cyfluthrin and cyhalothrin. The detection limits of these pesticides were between 0.13 and 1.45 ng g−1. The recovery of the pesticides spiked in various vegetables at 4 ng g−1 ranged from 42.9% to 105.3%, and the relative standard deviations were less than 16.2%.  相似文献   

19.
A method involving the simultaneous extraction and separation of 12 organochlorine pesticides (OCPs) from Angelicae sinensis was developed using supercritical fluid extraction (SFE). The pesticides in the study were alpha-, beta-, gamma- and delta-benzene hexachloride, PCNB (pentachloro- nitrobenzene), PCA (pentachloroaniline), HEPT (heptachlor), MPCPS (methyl-pentachlorophenyl sulfide), pp'-DDE [1,1-dichloro-2,2-bis (p-chlorophenyl) ethylene], op'-DDT [1,1,1,-trichloro-2-(o-chlorophenyl)-2-(p-chlorophenyl) ethane], pp'-DDD [1,1-dichloro-2,2-bis(p-chlorophenyl) ethane], and pp'-DDT [1,1,1,-trichloro-2,2-bis (p-chlorophenyl)ethane]. The extraction conditions were optimized as follows: pure CO(2), extraction pressure 15 MPa, extraction temperature 60 degrees C, extraction time 20 min, and flow-rate 1.5 mL/min. A GC method with electron capture detection was employed to determine the OCPs in Angelicae sinensis. An HPLC method was developed for the quantitative determination of active constituents. The SFE provided high decontamination rate of OCPs and low loss of active constituents in Angelicae sinensis.  相似文献   

20.
A photocatalytic degradation method was developed for polychlorobiphenyl (PCB) and organochloride pesticide (OCP) discrimination and quantification. A mixture of Aroclor 1260 and p,p′-DDT was irradiated at 254 nm by UV lamp (40 W) in the presence of TiO2 (30 mg mL−1 non-aqueous solution). Comparison of gas chromatograms showed that p,p′-DDT signals decreased significantly after irradiation, while Aroclor 1260s chromatograms did not show any difference before and after irradiation. Detection limits were 0.30 mg L−1 and 0.15 mg L−1 for p,p′-DDT and Aroclor 1260, respectively. The method was applied to spiked egg samples, the recoveries were found as 72% for DDT and 82.01% for Aroclor 1260.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号