首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
The present work describes the development and validation of an analytical method based on liquid chromatography (LC), coupled with tandem mass spectrometry (MS/MS) that allows the determination and confirmation of several endocrine-disrupting chemicals (EDCs) in honey. The EDCs studied were nine phenols of different nature: chlorophenols (2,4-dichlorophenol, 2,4,5-trichlorophenol, and pentachlorophenol), alkylphenols (4-tert-butylphenol, 4-tert-octylphenol, and 4-n-octylphenol) bisphenols (bisphenol-A and bisphenol-F), and 4-tert-butylbenzoic acid. The method incorporates a restricted-access material (RAM), coupled on-line to the LC-MS/MS system, which allows direct injection of the matrix into the RAM-LC-MS/MS system. The optimized method developed, RAM-LC-MS/MS, was applied to fortified honey samples, affording detection limits in the 0.6–7.2 ng g−1 range, calculated for a signal-to-noise ratio of 3. In addition, the method was validated as a quantitative confirmatory method according to European Union Decision 2002/657/EC. The validation criteria evaluated were linearity, repeatability, reproducibility, recovery, decision limits, detection capabilities, specificity, and ruggedness. Repeatability and within-laboratory reproducibility were evaluated at two concentration levels, being ±11% or below at 20 ng g−1. The decision limits (CCα) and detection capabilities (CCβ) were in the 1.7–12.6 and 2.8–21.6 ng g−1 range, respectively.  相似文献   

2.
A method for separation and quantitative determination of the iodosulfuron-methyl-sodium in water samples by high-performance liquid chromatography (HPLC) was developed and in-house validated in order to demonstrate its performance for monitoring of heterogeneous photocatalytic elimination of the herbicide iodosulfuron-methyl-sodium from water. Surface and ground water samples were used to demonstrate its selectivity, detection and quantification limits, linearity, trueness and precision. In addition, stability of iodosulfuron-methyl-sodium was studied in function of temperature and time. Method accuracy was quantified through measurement uncertainty estimate based on method validation data. The paper gives practical and easy to follow guidance on how uncertainty estimates can be obtained from method validation experiments. It shows that, if properly planned and executed, key precision and trueness studies undertaken for validation purposes can also provide much of the data needed to produce an estimate of measurement uncertainty. Our analytical protocol allowed us to quantify iodosulfuron-methyl-sodium in ground water and surface water in concentration level between 2.50–50.0 μmol L−1 with satisfactory recoveries (99–104%) and repeatability lower or equal than 0.3% for all the matrices. We also estimated within-laboratory reproducibility over 3-month period, which was 0.7%. We proved that the method was selective for determination of iodosulfuron-methyl-sodium in the relevant matrices. Measurement uncertainty of results was evaluated to be 4.0% with 95% confidence level. After validation and measurement uncertainty evaluation steps, results obtained showed that the method can be applied to efficiently monitor heterogenous photocatalytic degradation of the herbicide iodosulfuron-methyl-sodium.  相似文献   

3.
A novel, simple, and rapid reversed-phase liquid chromatography–tandem mass spectrometric methodology was developed for the analysis of natamycin in wine samples. Natamycin was protonated to form singly charged ions in an electrospray positive ion mode. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of three fragment ion transitions (666.3 → 648.2, 666.3 → 503.3, and 666.3 → 485.2) to provide a high degree of sensitivity and specificity. Chromatographic separation was performed on a rapid resolution column using a mobile phase consisting of an acetonitrile/water mixture with a total run time of 5.0 min. After only filtration as pretreatment, the sample was injected into the chromatographic system. The proposed method was validated in terms of selectivity, trueness, precision, decision limit (CCα), and detection capability (CCβ) according to 2002/657/EC Commission decision. The values for trueness, reported as bias (%), agreed with those established by the aforementioned document. Repeatability (intraday variability) values were 12.37% at a concentration of 1.0 μg L−1 and 8.99–4.19% at concentrations between 2.5 and 10 μg L−1. The overall within-laboratory (interday variability) reproducibility was 15.47% at a concentration of 1.0 μg L−1, which was significantly lower than the indicative value reported in the EU decision. The results indicated that the proposed approach is a sensitive, fast, reproducible, and robust methodology suitable for the analysis of natamycin levels in wine samples.  相似文献   

4.
Stilbenes and zeranol are nonsteroidal estrogenic growth promoters which are banned in the European Union (EU) for use in food-producing animals by Council Directive 96/22/EC. A liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed for the screening and confirmation of stilbenes (diethylstilbestrol, dienestrol, hexestrol) and resorcylic acid lactones (zeranol and its metabolites taleranol and zearalanone as well as the mycotoxins α-zearalenol, β-zearalenol and zearalenone) in bovine urine. The method permits the confirmation and quantification of stilbenes and resorcylic acid lactones at levels below 1 μg L−1 and 1.5 μg L−1, respectively. The validation was carried out according to Commission Decision 2002/657/EC, Chap. 3.1.3 “alternative validation” by a matrix-comprehensive in-house validation concept. Decision limit CCα, detection capability CCβ, recovery, repeatabiliy, within-laboratory reproducibility and the uncertainty of measurement were calculated. Furthermore, a factorial effect analysis was carried out to identify factors that have a significant influence on the method. Factors considered to be relevant for the method in routine analysis (e.g. operator, matrix condition, storage duration of the extracts before measurement, different cartridge lots, hydrolysis conditions) were systematically varied on two levels. The factorial analysis showed that different cartridge lots, storage durations and matrix conditions can exert a relevant influence on the method.  相似文献   

5.
An isocratic HPLC method for the determination with screening purposes of anabolic androgenic steroids (AASs: fluoxymesterone, boldenone, nortestosterone, metandrostenolone, norethindrone, methyltestosterone and bolasterone), used as growth promoting agents, in finishing pig feed samples has been developed and validated. The separation was achieved by using a reversed-phase Chromolith RP-18e column at controlled temperature, UV-detection at 245 nm and epitestosterone as internal standard. The method development involved optimization of different aqueous-organic mobile phases using methanol or acetonitrile as organic modifiers, flow-rate and temperature. The optimum separation for these compounds was achieved at 40 °C using ultrapure water:acetonitrile (71:29, v/v) as mobile phase and 3 mL min−1 flow-rate, allowing the separation of AASs with baseline resolution in about 15 min. The optimized method was applied to the analysis of AASs in finishing pig feed samples. Prior to HPLC, sample preparation procedure was used by leaching using acetonitrile, saponification in a basic medium and solid-phase extraction using polymeric Abselut Nexus cartridges. Method validation has been carried out according to the European Commission Decision 2002/657/EC. The extraction efficiencies, decision limits (CCα) and detection capabilities (CCβ) for these compounds were in the range 83-96%, 27-37 and 32-47 μg kg−1 range, respectively. The within-laboratory reproducibility at 1, 1.5 and 2 CCβ concentration levels were smaller than 13, 10 and 8%, respectively. Finally, the proposed method was successfully applied to nine different kinds of animal feed.  相似文献   

6.
This study describes the design and optimisation of a field flow system for the in-situ collection and on-line determination of phosphate, nitrate and nitrite by flow injection analysis-spectrophotometry. The method is based on the initial determination of phosphate as its phosphoantimonylmolybdenum blue complex which is then oxidized on-line by nitrite and the decrease in absorbance is monitored at 880 nm. Nitrate is determined as the difference between total and initial nitrite content in a separate flow after reduction to nitrite in a cadmium reductive column. The calibration curves were linear in the range 0–2.00 mg L−1 P-phosphate, 0–10.00 mg L−1 nitrite and 0–7.00 mg L−1 nitrate with correlation coefficients of 0.9979, 0.9993 and 0.9995, respectively. The detection limits, calculated as 3S/N, were 0.15 mg L−1 for P-phosphate, 0.17 mg L−1 for nitrite and 0.09 mg L−1 for nitrate. The reproducibility was below 3.0% (n = 7). Method validation in the analysis of natural water and wastewater samples revealed that it can efficiently be applied to the determination of the target analytes, with recoveries in the range of 92–108%. Correspondence: Athanasios G. Vlessidis, Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, Ioannina 45110, Greece  相似文献   

7.
A simple, reproducible, and efficient liquid chromatographic method was developed with UV detection. Water (0.05% TFA):acetonitrile (0.05% TFA) was used as the mobile phase in a gradient system for the determination of procyanidin B2 (PB2) and epicatechin (EC) in the bark of Guazuma ulmifolia Lam. The analysis was performed using a Phenomenex Gemini RP C18 column (5 μm) as stationary phase, at 30 °C, with a flow rate of 0.8 mL min−1, at a wavelength of 210 nm for detection and determination. The main validation parameters of the method were also determined. Calibration curves were found to be linear, with ranges of 20.00–150.00 (PB2) and 10.00–110.00 μg mL−1 (EC). The correlation coefficients of linear regression analysis were between 0.9981 and 0.9988, and the detection limits were between 2.89 and 2.54 μg mL−1. The contents of PB2 and EC were successfully determined, with satisfactory reproducibility and recovery. Recoveries of the PB2 and EC were 103.00 and 104.01%, respectively. The method was successfully applied to the determination of procyanidins in the bark of G. ulmifolia.  相似文献   

8.
A fully automated method has been developed for analysis of eighteen antibacterial compounds, including penicillins, cephalosporins and sulfonamides, in animal feed with limits of quantification in the range 0.25–5.79 μg kg−1. The method is based on pressurized liquid extraction of 3 g homogenized feed with water and online clean-up of 500 μL of the extract with C18HD cartridges. The purified sample was directly analysed by liquid chromatography–electrospray tandem mass spectrometry (SPE–LC–ESI-MS–MS). Chromatographic separation was achieved within 10 min by use of a C12 Phenomenex Hydro-RP reversed-phase analytical column and a mobile phase gradient (water + 0.1% formic acid–methanol + 0.1% formic acid). The method was validated, revealing capability for detection of concentrations as low as 0.09 μg kg−1, decision limits (CCα) and detection capabilities (CCβ) in the range 10–174 μg kg−1 and 22–182 μg kg−1, respectively, and inter-day precision ranging from 0.7 to 8.3%. Recovery, with internal standard correction, was in the range 93–134% for all analytes. The method was then applied to analysis of fifteen feed samples, nine of which contained at least one antimicrobial at concentrations between 0.006 and 1.526 mg kg−1. The performance data and results from the method were compared with those from a previous method developed by our group, using offline SPE, by analyzing the same set of samples by both methods. The online SPE approach resulted in slightly improved sensitivity, with LODs of 0.09–2.12 μg kg−1 compared with 0.12–3.94 μg kg−1 by the offline approach. In general, better recovery was achieved by use of online purification (for 72% of the analytes) and the correlation between the two methods was good. The main advantages of the new online method are rapid and automated sample pre-treatment, and reduction of sample manipulation, enabling high-throughput analysis and highly accurate results. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety.  相似文献   

9.
Summary Eight triazine herbicides, prometon, propazine, atrazine, simazine, prometryn, ametryn, metribuzin, and cyanazine, have been extracted from human whole blood and urine samples by headspace solid-phase microextraction (SPME) with a polydimethylsiloxane-coated fiber and quantified by capillary gas chromatography with nitrogen-phosphorus detection. Extraction efficiencies for all compounds were 0.21–0.99% for whole blood, except for cyanazine (0.06%). For urine, the extraction efficiencies for prometon, propazine, atrazine, prometryn and ametryn were 13.6–38.1%, and those of simazine, metribuzin and cyanazine were 1.35–8.73%. The regression equations for the compounds extracted from whole blood were linear within the concentration ranged 0.01–1 μg (0.5 mL)−1 for prometon, propazine, atrazine, prometryn, and ametryn, and 0.02–1 μg (0.5 mL)−1 for simazine, metribuzin, and cyanazine. For urine, regression equations for all compounds were linear within the concentration range 0.005–0.25 μg mL−1. Compound detection limits were 2.8–9.0 ng (0.5 mL)−1 and 0.4–2.0 ng mL−1 for whole blood and urine, respectively. The coefficients of within-day and day-to-day variation were satisfactory for all the compounds, and not greater than 10.3 and 14.2%, respectively. Data obtained from determination of atrazine in rat whole blood after oral administration of the compound are also presented.  相似文献   

10.
A simple, rapid, sensitive high performance liquid chromatography method with fluorescent detection was developed and validated for the determination of bendroflumethiazide in human plasma. Extraction from the plasma was by liquid-liquid extraction using ethyl acetate. Mosapride citrate was used as the internal standard. The chromatographic separation was performed on reverse phase LiChrosphere C18 column with mobile phase comprising of acetonitrile and phosphate buffer (38:62 v/v). The assay precision ranged from 0.9–12.5 and accuracy between 96.8–108.8%, revealing that the method has good reproducibility over the concentration range of 0.98–100.16 ng mL−1. The validated method has been applied to analyze the bendroflumethiazide concentrations for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

11.
This contribution describes use of a separation method based on on-line coupling of a multisyringe flow system with a chromatographic monolithic column for simultaneous determination of hydrochlorothiazide and losartan potassium in tablets. The system comprised a multisyringe module, three low-pressure solenoid valves, a monolithic C18 column (25 mm × 4.6 mm i.d.), and a diode-array detector. The mobile phase was 10 mmol L−1 potassium dihydrogen phosphate (pH 3.1)-acetonitrile-methanol (65:33:2 v/v/v) at a flow rate 0.8 mL min−1. UV detection was carried out at 226 nm. The multi-syringe chromatographic (MSC) method with UV spectrophotometric detection was optimized and validated. Results from validation were very good. The analysis time was about 400 s. The method was found to be applicable to routine analysis of both compounds in tablets. The coupling of the monolithic columns with a multi-syringe flow-injection analysis manifold provides an excellent and inexpensive tool to solve the separation problems without use of HPLC instrumentation.  相似文献   

12.
A reversed-phase ion-pairing liquid chromatographic method was developed and validated for the assay of Fe(II) in ferrous bisglycinate (Fe-bis-gly) capsules using 4-(2-pyridylazo) resorcinol reagent. The analysis was carried out using a Gemini RP-18 (150 mm × 4.6 mm I.D., particle size 5 μm) analytical column; the mobile phase consisted of a mixture of acetonitrile–water (28:72 v/v) containing 1 mM tetrabutylammonium hydrogensulfate and 1% phosphate buffer (pH 8.0). The flow rate was 1.0 mL min−1 and the detection was achieved with a photodiode array (PDA) detector at 706 nm. The specificity of the method was proved using stress conditions and evaluated using a PDA detector. The data validation showed that the method is specific, fast, accurate, and reproducible for the determination of Fe-bis-gly in dosage form. The response was linear over a range of 1.0–2.6 μg mL−1 (r = 0.9999). The accuracy of the method ranged from 98.02 to 102.75%. The RSD values for intra- and inter-day precision studies were below 1.3 and 1.1%, respectively. There was no interference of the excipients on the determination of the active pharmaceutical ingredient.  相似文献   

13.
Summary A method for determination of trace amounts of the pesticides tebufenpyrad and oxadiazon, previous solid-phase microextraction (SPME), was developed using gas chromatographymass spectrometry and selected ion monitoring (GC-MS; SIM). Both pesticides were extracted with a fused silica fiber coated with 100 μm polydimethylsiloxane. The effects of pH ionic strength, sample volume, extraction and desorption times as well as extraction temperature were studied. The linear concentration range of application was 0.5–250 ng mL−1 for both compounds, with a detection limit of 0.06 ng mL−1 for tebufenpyrad and 0.02 ng mL−1 for oxadiazon. SPME-GC-MS analysis yielded good reproducibility (RSD between 7.5–10.1%). It was used to check the eventual existence of tebufenpyrad and oxadiazon above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. It can be applied as a monitoring tool for water, soil and urine in the investigation of environmental and occupational exposure to tebufenpyrad and oxadiazon.  相似文献   

14.
This paper reports a novel approach for the detection, confirmation, and quantification of 15 selected pyrethroid pesticides, including pyrethins, and two metabolites of dithiocarbamates in foods by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS–MS). The proposed method makes use of a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure that combines isolation of the pesticides and sample cleanup in a single step. Analysis of pyrethroids and dithiocarbamate metabolites was performed by UPLC–MS–MS operated with electrospray and atmospheric pressure chemical ionization, respectively. Two specific precursor–product ion transitions were acquired per target compound in multiple reaction monitoring (MRM) mode. Such acquisition achieved the minimum number of identification points according to European Commission (EC) document no. SANCO/10684/2009, thus fulfilling the EC point system requirement for identification of contaminants in samples. The method was validated with a variety of food samples. Calibration curves were linear and covered from 1 to 800 μg kg−1 in the sample for all target compounds. Average recoveries, measured at mass fractions of 10 and 100 μg kg−1 for pyrethroids and 5 and 50 μg kg−1 for dithiocarbamate metabolites, were in the range of 70–120% for all target compounds with relative standard deviations below 20%. Method limits of quantification (MLOQ) were 10 μg kg−1 and 5 μg kg−1 for pyrethroids and dithiocarbamate metabolites, respectively. The method has been successfully applied to the analysis of 600 food samples in the course of the first Hong Kong total diet study with pyrethroids and metabolites of dithiocarbamates being the pesticides determined.  相似文献   

15.
Benzotriazoles are a group of UV absorbing compounds considered emerging contaminants that are used in different personal care products, and therefore, it is of high interest to develop sensitive and fast methods for investigating their presence in the environment. In this work, we present the development and application of a novel method based on on-line solid-phase extraction coupled to ultra-performance liquid chromatography with tandem mass spectrometry detection (SPE-UPLC-MS/MS) for the determination of seven benzotriazole UV stabilizers (BUVSs) in coastal marine and wastewater samples. This process is compared with a conventional off-line SPE procedure followed by UPLC-MS/MS. The parameters affecting the performance of the sample preparation and determination processes were evaluated. The results indicate that the on-line procedure provides for better sensitivity and reproducibility and is faster and easier than the off-line procedure. The detection limits and quantification limits achieved were in the range of 0.6–4.1 ng∙L−1 and 2.1–14 ng∙L−1 and relative standard deviation between 6.2 and 10 %. The developed method was applied to coastal marine and wastewater samples from Gran Canaria Island (Spain). All of the BUVSs studied were detected in the samples from wastewater treatment plants and two were found in the seawater samples (UV P in the range of 2.8–4.4 ng∙L−1 and UV 360 between 3.6 and 5.2 ng∙L−1).  相似文献   

16.
Thiacalix[4]arenetetrasulfonate was treated with Ce(IV) in water at pH 9.5 to give novel phosphoester-hydrolyzing complexes. The dinuclear Ce(IV) complex promoted the hydrolysis of p-nitrophenyl phosphate with a turnover frequency of 6.8 h−1 at 50 °C, showing fourfold higher activity than the mononuclear complex. The dinuclear complex was readily immobilized onto an antibody by simply mixing them in water, hence its phosphatase-like activity was applied to the color-developing reaction in immunoassay. The model assay using an antibody labeled with the dinuclear complex allowed the detection of as little as 10 ng mL−1 of a tumor marker, Bence–Jones protein, in a 96-well microtiter plate format. Analysis of urine for Bence–Jones protein was performed by the proposed method.  相似文献   

17.
Organophosphate triesters tris(1,3-dichloro-2-propyl) phosphate (TDCPP) and triphenyl phosphate are widely used flame retardants (FRs) present in many products common to human environments, yet understanding of human exposure and health effects of these compounds is limited. Monitoring urinary metabolites as biomarkers of exposure can be a valuable aid for improving this understanding; however, no previously published method exists for the analysis of the primary TDCPP metabolite, bis(1,3-dichloro-2-propyl) phosphate (BDCPP), in human urine. Here, we present a method to extract the metabolites BDCPP and diphenyl phosphate (DPP) in human urine using mixed-mode anion exchange solid phase extraction and mass-labeled internal standards with analysis by atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry. The method detection limit was 8 pg mL−1 urine for BDCPP and 204 pg mL−1 for DPP. Recoveries of analytes spiked into urine ranged from 82 ± 10% to 91 ± 4% for BDCPP and from 72 ± 12% to 76 ± 8% for DPP. Analysis of a small number of urine samples (n = 9) randomly collected from non-occupationally exposed adults revealed the presence of both BDCPP and DPP in all samples. Non-normalized urinary concentrations ranged from 46–1,662 pg BDCPP mL−1 to 287–7,443 pg DPP mL−1, with geometric means of 147 pg BDCPP mL−1 and 1,074 pg DPP mL−1. Levels of DPP were higher than those of BDCPP in 89% of samples. The presented method is simple and sufficiently sensitive to detect these FR metabolites in humans and may be applied to future studies to increase our understanding of exposure to and potential health effects from FRs.  相似文献   

18.
A rapid and inexpensive method for simultaneous quantification of terbumeton (TER), and its major potential metabolites (TED; terbumeton-desethyl, TOH; terbumeton-2-hydroxy and TID; terbumeton-deisopropyl) in soil bulk water (SBW) samples is proposed. The analytical method involves extraction–concentration from SBW samples using a graphitized carbon black (GCB) cartridge followed by their separation–detection by reversed-phase high-performance liquid chromatography analysis using a C18 column and a diode array detector. A mobile phase of acetonitrile−0.005 mol L−1 phosphate buffer (pH 7.0) (35:65, v/v) at a flow rate of 0.8 mL min−1 in isocratic elution mode has been used. After optimization of the extraction and separation conditions, this method can be used for the simultaneous determination of investigated compounds in the range of the international limits of 0.1 μg L−1. For TER the detection limit was 0.009 μg L−1 and it was 0.100, 0.550, and 0.480 μg L−1 for TED, TOH, and TID, respectively. The recoveries of TER, TED, TOH, and TID from SBW samples, measured at three levels of concentration range, were found to be between 48.0 and 102.0%. The intra-day precision measured by relative standard deviation (RSD) was always lower than 9.0%.  相似文献   

19.
D. Sircar  G. Dey  A. Mitra 《Chromatographia》2007,65(5-6):349-353
A reverse phase HPLC method was developed and validated for the simultaneous determination of 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid in the root extracts of Hemidesmus indicus. A comprehensive validation of the method including sensitivity, linearity, reproducibility, accuracy, limit of detection (LOD) and limit of quantification (LOQ) was conducted using the optimized chromatographic conditions. The method was found to be linear (r > 0.998) in the range of 5–350 μg mL−1 for 2-hydroxy-4-methoxybenzaldehyde and for 2-hydroxy-4-methoxybenzoic acid (r > 0.999) in the range 10–300 μg mL−1. The method was found to be precise with inter-day precision values (% RSD) in the ranges of 0.61–1.76% for 2-hydroxy-4-methoxybenzaldehyde and 1.3–2.8% for 2-hydroxy-4-ethoxybenzoic acid while intra-day precisions (% RSD) of two analytes were in the range of 0.41–1.07 and 0.95–2.5%. The limits of detection (LODs) for 2-hydroxy-4-methoxybenzaldehyde and 2-hydroxy-4-methoxybenzoic acid were 0.84 and 2.34 μg mL−1. The described method was fast, sensitive and reproducible, and thus well suited for routine analysis of these two compounds from root extracts of H. indicus and other plants.  相似文献   

20.
A kinetic method for the determination of organosulfur compounds by UV spectrophotometry is described. Organosulfur compounds have been shown to inhibit the Hg(II)-catalyzed substitution of cyanide in hexacyanoferrate(II) by 2-methylpyrazine (2-Mepz). The inhibitory effect is proportional to the concentration of inhibitor and can be used as the basis for the determination of trace amounts of organosulfur compounds such as cysteine, 2,3-dimercaptopropanol (DMP) and thioglycolic acid (TGA). Both the influence of the reaction variables and interference of a variety of ions have been studied. A mechanism for the inhibition process is proposed. The determination range depends on the amount of Hg(II) added and stability of the Hg(II)–ligand complex. Kinetic parameters were determined from Lineweaver–Burk plots, obtained in the absence and presence of the inhibitor. Excellent linearity is observed for all analytes over their respective concentration ranges with correlation coefficient >0.9. The condition calibration curves were linear in the range of 5 × 10−6–15 × 10−6 M for cysteine, 1 × 10−7–7 × 10−7 M for DMP and 1 × 10−6–10 × 10−6 M for TGA. The detection limits were 1.18 × 10−7 M for cysteine, 4.16 × 10−8 M for DMP and 1.30 × 10−7 M for TGA. The effects of amino acids that can interfere in the determination of cysteine were studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号