首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Five new rat monoclonal antibodies (mAbs) for 2,4,6-trinitrotoluene (TNT) and other nitroaromatic compounds, including, especially, the metabolite 2-amino-4,6-dinitrotoluene (2-ADNT), are described. Five heterogeneous, competitive enzyme-linked immunosorbent assays (ELISAs) were developed. Assay 1 uses mAb DNT4 3F6 as recognition element and gives a standard curve for TNT in 40 mmol L–1 phosphate buffered saline (PBS) with a test midpoint (IC50) of 0.26±0.08 g L–1 (n=20). Assay 2 (mAb DNT4 4G4) has an IC50 of 0.35±0.07 g L–1 (n=18), assay 3 (mAb DNT4 1A3) has an IC50 of 0.73±0.14 g L–1 (n=15), and assay 4 (mAb DNT4 1A7) has an IC50 of 2.32±0.70 g L–1 (n=15). Assay 5 (mAb DNT2 4B4) is very selective for 2-ADNT and has an IC50 of 8.5±1.7 g L–1 (n=15) in PBS. These antibodies for nitroaromatic compounds differ not only in their sensitivity but also in their selectivity. Major cross-reactants are 1,3,5-trinitrobenzene, 2-ADNT, 4-amino-2,6-dinitrotoluene (4-ADNT), 2,4-dinitroaniline, 3,5-dinitroaniline, and 2,6-dinitroaniline. Although assay 5 is not highly sensitive, the mAb DNT2 4B4 in this assay is highly selective for 2-ADNT. Of all the compounds tested, only 2,4-dinitroaniline and 3,5-dinitroaniline had relevant cross reactivities, 18% and about 26%, respectively. Two ELISAs, using mAbs DNT4 3F6 and DNT2 4B4, were used to analyze different concentrations of TNT and 2-ADNT, respectively, in three different surface water matrices (river and lake water). Both assays were affected by the matrix, but usually performed well (recovery within the range 70–120%). In addition, these ELISAs were used to analyze mixtures of TNT, 2-ADNT, and 4-ADNT, at three different concentrations, in the same water matrices. A different recognition pattern was clearly visible with both assays and depended on the cross reactivities of the corresponding mAb.Dedicated to the memory of Wilhelm Fresenius  相似文献   

2.
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L−1, respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L−1. The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L−1 could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5–16 μg L−1 (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.  相似文献   

3.
A mid-infrared enzymatic assay for label-free monitoring of the enzymatic reaction of fructose-1,6-bisphosphatase with fructose 1,6-bisphosphate has been proposed. The whole procedure was done in an automated way operating in the stopped flow mode by incorporating a temperature-controlled flow cell in a sequential injection manifold. Fourier transform infrared difference spectra were evaluated for kinetic parameters, like the Michaelis–Menten constant (K M) of the enzyme and V max of the reaction. The obtained K M of the reaction was 14 ± 3 g L−1 (41 μM). Furthermore, inhibition by adenosine 5′-monophosphate (AMP) was evaluated, and the K MApp value was determined to be 12 ± 2 g L−1 (35 μM) for 7.5 and 15 μM AMP, respectively, with V max decreasing from 0.1 ± 0.03 to 0.05 ± 0.01 g L−1 min−1. Therefore, AMP exerted a non-competitive inhibition.  相似文献   

4.
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

5.
Specific polyclonal antibodies against s-triazine herbicides were obtained by preparing immunogens coupling home-synthesized haptens derivatives of simazine (6-chloro-N-ethyl-N′-ethyl-1,3,5-triazine-2,4-diamine) to lysine groups of hemocyanin from keyhole limpets and bovine serum albumin carrier proteins. Three highly sensitive rabbit antisera were obtained and evaluated with a battery of six enzyme tracers derived from triazine structures in an optimized ELISA format. The antiserum As8 and the HRP-2f tracer, which yield the best assay sensitivity for simazine (detection limit 0.11 ± 0.02 μg L−1, IC50 0.88 ± 0.04 μg L−1), were applied to the development of a sensitive flow-through immunoassay for the analysis of this herbicide. The automated assay was based on a direct competitive immunosorbent assay and fluorescence detection. The optimized method presents an IC50 value of 0.35 ± 0.04 μg L−1 with a detection limit of 1.3 ± 0.9 ng L−1 and a dynamic range from 0.010 to 7.5 μg L−1 simazine. The generic nature of the antiserum was shown by good relative cross-reactivities with other triazines such as atrazine (420%) or propazine (130%) and a lower response to terbutylazine (6.4%) and desethyl-atrazine (2.2%). No cross-reactivity was obtained for nonrelated pesticides such as 2,4-dichlorophenoxyacetic acid or linuron and the assay could be applied as a screening method for triazine herbicides. The total analysis time was 30 min per determination and the immunosensor could be reused for more than 150 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of simazine in surface water samples at the nanogram per liter level. The results obtained by comparative analysis of the immunosensor with a chromatographic procedure for triazines showed a close correspondence.  相似文献   

6.
To measure dermal exposure of a non-agricultural occupationally exposed population to pesticides, a new method has been developed for analysis of 13 pesticides from different classes (fungicides, herbicides, insecticides) on dermal patches. The method includes extraction of the patches and analysis of the pesticides by GC–MS and/or HPLC–fluorescence. Water-soluble pesticides (glyphosate and glufosinate) on patches were ultrasonically extracted twice with ultra-pure water for 10 min and analysed by HPLC–fluorescence after derivatisation with FMOC. Organic-soluble pesticides (bifenthrin, cyprodinil, difufenicanil, fludioxonil, oxadiazon, pyriproxyfen, clopyralid, 2,4-D, fluroxypyr, 2,4-MCPA, and triclopyr) were extracted ultrasonically twice for 10 min with 70:30 dichloromethane–acetonitrile and analysed by GC–MS directly or after derivatisation with N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide. Detection limits varied between 3 and 4 μg L−1 for water-soluble pesticides and between 1 and 10 μg L−1 for organic-soluble pesticides.  相似文献   

7.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

8.
The development of a direct competitive enzyme-linked immunosorbent assay based on polyclonal antibodies for N-methylcarbamate insecticide metolcarb is described. Two new haptens for the metolcarb were designed and synthesized. Both haptens were conjugated with keyhole limpet hemocyanin to form the immunogens. Four rabbits were immunized with the immunogens for production of polyclonal antibodies against metolcarb. Antisera titers were tested on the homologous coating antigens using a noncompetitive indirect enzyme-linked immunosorbent assay. The high titer antisera were used to develop the direct competitive enzyme-linked immunosorbent assay for the detection of metolcarb. The antibody–antigen combination with the highest selectivity for metolcarb was further optimized and its tolerance to changes in chemical conditions (ionic strength, pH value, and organic solvent) was studied. Under optimum conditions, the sensitivity and the limit of detection were determined to be 22 μg L−1 and 1.2 μg L−1 respectively. Determination of metolcarb in fruit juices and vegetables was accomplished by simple, rapid, and efficient extraction methods. Recoveries of metolcarb from spiked samples ranged from 80.5% to 109.5%. Validation of the developed immunosorbent assay was conducted by comparison of results from high-performance liquid chromatography. The correlation between the data obtained using developed immunosorbent assay and high-performance liquid chromatography was high (R 2 = 0.9884). Therefore, the developed immunosorbent assay in this study was suitable for the rapid quantitative determination of metolcarb in agricultural products.  相似文献   

9.
Procalcitonin (PCT)—a diagnostic serum parameter for bacterial infection and sepsis—is of great interest in the field of biosensors for point-of-care testing. Its detection needs specific biological recognition elements, such as antibodies. Herein, we describe the development and characterization of rat monoclonal antibodies (mAbs) for PCT, and their application in enzyme-linked immunosorbent assays (ELISAs) for the determination of PCT in patient serum samples. From about 50 mAbs, two mAbs, CALCA 2F3 and CALCA 4A6, were selected as a pair with high affinity for PCT in sandwich immunoassays. Both mAbs could be used either as capture or as detection mAb. They were Protein G-purified and biotinylated when used as detection mAb. The setup of two sandwich ELISAs with standards of human recombinant (hr) PCT, using either CALCA 2F3 (assay A) or CALCA 4A6 (assay B) as capture mAbs and the biotinylated mAbs CALCA 4A6 or CALCA 2F3, respectively, as detection mAbs, led to highly specific determinations of PCT without cross-reactivity to calcitonin and katacalcin. Test midpoints (IC50) of both assays were determined for hrPCT standards in 4% (w/v) human serum albumin and found with 2.5 (assay A) and 2.7 μg L−1 (assay B). With both sandwich ELISAs a collection of eight patient serum samples have been determined in comparison to the determination by the Elecsys BRAHMS PCT assay. Good correlations between our prototype ELISAs and the BRAHMS assay could be demonstrated (R 2: assay A, 0.996 and assay B, 0.990). The use of these newly developed anti-PCT mAbs should find broad applications in immunosensors for point-of-care diagnostics of sepsis and systemic inflammation processes.  相似文献   

10.
A novel, simple, and rapid reversed-phase liquid chromatography–tandem mass spectrometric methodology was developed for the analysis of natamycin in wine samples. Natamycin was protonated to form singly charged ions in an electrospray positive ion mode. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of three fragment ion transitions (666.3 → 648.2, 666.3 → 503.3, and 666.3 → 485.2) to provide a high degree of sensitivity and specificity. Chromatographic separation was performed on a rapid resolution column using a mobile phase consisting of an acetonitrile/water mixture with a total run time of 5.0 min. After only filtration as pretreatment, the sample was injected into the chromatographic system. The proposed method was validated in terms of selectivity, trueness, precision, decision limit (CCα), and detection capability (CCβ) according to 2002/657/EC Commission decision. The values for trueness, reported as bias (%), agreed with those established by the aforementioned document. Repeatability (intraday variability) values were 12.37% at a concentration of 1.0 μg L−1 and 8.99–4.19% at concentrations between 2.5 and 10 μg L−1. The overall within-laboratory (interday variability) reproducibility was 15.47% at a concentration of 1.0 μg L−1, which was significantly lower than the indicative value reported in the EU decision. The results indicated that the proposed approach is a sensitive, fast, reproducible, and robust methodology suitable for the analysis of natamycin levels in wine samples.  相似文献   

11.
A simple and efficient method, based on ultrasound-enhanced surfactant-assisted dispersive liquid–liquid microextraction (UESA-DLLME) followed by high-performance liquid chromatography (HPLC) has been developed for extraction and determination of ketoconazole and econazole nitrate in human blood samples. In this method, a common cationic surfactant, cetyltrimethylammonium bromide (CTAB), was used as dispersant. Chloroform (40 μL) as extraction solvent was added rapidly to 5 mL blood containing 0.068 mg mL−1 CTAB. The mixture was then sonicated for 2 min to disperse the organic chloroform phase. After the extraction procedure, the mixture was centrifuged to sediment the organic chloroform phase, which was collected for HPLC analysis. Several conditions, including type and volume of extraction solvent, type and concentration of the surfactant, ultrasound time, extraction temperature, pH, and ionic strength were studied and optimized. Under the optimum conditions, linear calibration curves were obtained in the ranges 4–5000 μg L−1 for ketoconazole and 8–5000 μg L−1 for econazole nitrate, with linear correlation coefficients for both >0.99. The limits of detection (LODs, S/N = 3) and enrichment factors (EFs) were 1.1 and 2.3 μg L−1, and 129 and 140 for ketoconazole and econazole nitrate, respectively. Reproducibility and recovery were good. The method was successfully applied to the determination of ketoconazole and econazole nitrate in human blood samples.  相似文献   

12.
A fast and sensitive liquid chromatography–mass spectrometry method was developed for the determination of ursolic acid (UA) in rat plasma and tissues. Glycyrrhetinic acid was used as the internal standard (IS). Chromatographic separation was performed on a 3.5 μm Zorbax SB-C18 column (30 mm × 2.1 mm) with a mobile phase consisting of methanol and aqueous 10 mM ammonium acetate using gradient elution. Quantification was performed by selected ion monitoring with (m/z) 455 for UA and (m/z) 469 for the IS. The method was validated in the concentration range of 2.5 − 1470 ng mL−1 for plasma samples and 20 − 11760 ng g−1 for tissue homogenates. The intra- and inter-day assay of precision in plasma and tissues ranged from 1.6% to 7.1% and 3.7% to 9.0%, respectively, and the intra- and inter-day assay accuracy was 84.2 − 106.9% and 82.1 − 108.1%, respectively. Recoveries in plasma and tissues ranged from 83.2% to 106.2%. The limits of detections were 0.5 ng mL−1 or 4.0 ng g−1. The recoveries for all samples were >90%, except for liver, which indicated that ursolic acid may metabolize in liver. The main pharmacokinetic parameters obtained were T max = 0.42 ± 0.11 h, C max = 1.10 ± 0.31 μg mL−1, AUC = 1.45 ± 0.21 μg h mL−1 and K a = 5.64 ± 1.89 h−1. The concentrations of UA in rat lung, spleen, liver, heart, and cerebellum were studied for the first time. This method is validated and could be applicable to the investigation of the pharmacokinetics and tissue distribution of UA in rats.  相似文献   

13.
There is a lack of fundamental knowledge about the scale up of biosurfactant production. In order to develop suitable technology of commercialization, carrying out tests in shake flasks and bioreactors was essential. A reactor with integrated foam collector was designed for biosurfactant production using Bacillus subtilis isolated from agricultural soil. The yield of biosurfactant on biomass (Y p/x), biosurfactant on sucrose (Y p/s), and the volumetric production rate (Y) for shake flask were obtained about 0.45 g g−1, 0.18 g g−1, and 0.03 g l−1 h−1, respectively. The best condition for bioreactor was 300 rpm and 1.5 vvm, giving Y x/s, Y p/x, Y p/s, and Y of 0.42 g g−1, 0.595 g g−1, 0.25 g g−1, and 0.057 g l−1 h−1, respectively. The biosurfactant maximum production, 2.5 g l−1, was reached in 44 h of growth, which was 28% better than the shake flask. The obtained volumetric oxygen transfer coefficient (K L a) values at optimum conditions in the shake flask and the bioreactor were found to be around 0.01 and 0.0117 s−1, respectively. Comparison of K L a values at optimum conditions shows that biosurfactant production scaling up from shake flask to bioreactor can be done with K L a as scale up criterion very accurately. Nearly 8% of original oil in place was recovered using this biosurfactant after water flooding in the sand pack.  相似文献   

14.
The possibilities of different media formed by lecithin/n-butanol (n-BuOH)/water ternary mixtures for the analysis of all-trans-retinol by fluorescence have been studied. Fluorescence intensity of retinol increases in the presence of different types of aggregates formed in these media. Analytical features are good, the detection limit and quantification limit have micrograms per liter levels, and the linear range and sensitivity are appropriate to determine retinol in cosmetic samples. The analysis of retinol in anti-wrinkle creams can be achieved directly without any pretreatment of the sample. The vesicles built up from a biocompatible surfactant (lecithin) in aqueous solution with a low amount of n-BuOH permit an appropriated media for a simple, rapid, and sensitive analytical method. This method has a linear range between 64.1 and 800 μg L−1, a sensitivity of 202.3 L mg−1, and a low detection and quantification limit at 19.2 and 64.1 μg L−1, respectively.  相似文献   

15.
Quorum sensing (QS) is a communication mechanism between bacteria using diffusible chemical signaling molecules, which are called autoinducers (AI). By detecting the concentration of quorum sensing molecules through binding to a specific receptor protein, bacteria regulate their gene expressions when the concentration of autoinducers and thus the cell density reaches a threshold level. Many Gram-negative bacteria use acylated homoserine lactones (HSLs) as autoinducers. Because of the broad biological functions of HSLs, interest in detection and analysis of HSLs is increasing with a view to their medical, biotechnological, and agricultural applications. In this study, an anti-HSL antibody-based immunochemical detection method has been developed. Four structurally distinct HSL haptens, named HSL1, HSL2, HSL3, and HSL4, have been designed for antibody and assay development. New rat anti-HSL monoclonal antibodies (mAbs) have been produced in-house and characterized with enzyme-linked immunosorbent assays (ELISA), both in the coating antigen and in the enzyme tracer format. Eight mAbs (HSL1-1A5, HSL1-8E1, HSL1/2-2C10, HSL1/2-4H5, HSL4-4C9, HSL4-5E12, HSL4-5H3, and HSL4-6D3) will be presented in this paper. We demonstrate that the anti-HSL mAbs have distinguished sensitivity and selectivity toward HSLs depending upon their chemical structures. The optimized assays are capable of detecting HSLs in the microgram per liter (low micromolar to nanomolar) range. The best IC50 (test midpoint) was 134 ± 30 μg L−1 (n = 54) for N-(3-oxodecanoyl)-l-homoserine lactone (3-oxo-C10-HSL) using mAb HSL1/2-2C10 and HSL1–HRP in the enzyme tracer format. In the coating antigen format, the most selective mAb for N-octanoyl-l-homoserine lactone (C8-HSL) was mAb HSL4-4C9. Additionally, anti-HSL mAbs showed higher sensitivity against hydrolyzed HSLs, namely homoserines. These compounds might also occur under certain biological conditions. This study marks the beginning of new ways for quick and cost-effective HSL detection, requiring small sample amounts (less than 1 mL) and little to no sample preparation.  相似文献   

16.
2,4-二硝基苯胺与牛血清白蛋白相互作用的研究   总被引:1,自引:0,他引:1  
通过荧光和紫外光谱法研究了2,4-二硝基苯胺同牛血清白蛋白(BSA)的相互作用. 2,4-二硝基苯胺对牛血清白蛋白的内源荧光具有强烈的猝灭作用. 二者之间形成不发荧光的复合物是导致荧光猝灭的主要原因. 计算了其结合常数和结合位点数. 紫外光谱法进一步证明了其猝灭机理为静态猝灭. 根据能量转移理论计算了作用距离(3.13 nm). 同步荧光的结果表明2,4-二硝基苯胺的存在改变了牛血清白蛋白的分子构象.  相似文献   

17.
This work presents a comparison of convective interaction media (CIM) and controlled pore glass (CPG) as solid supports for immunoglobulin antibodies used in bioanalytical detection of allergens in foodstuffs. A flow-injection manifold with highly sensitive thermal lens spectrometric detection was used for this purpose. Using beta-lactoglobulin, a milk allergen, as a model analyte, CIM disc supports had a higher linear range (0.2–3.5 μg L−1), better reproducibility (intra-day RSD = 1%, inter-day RSD = 10%), lower consumption of reagents, and better immunocolumn stability (1 month, over 240 injections of substrate), while providing comparable LODs (0.1 μg L−1). Application of CIM discs as solid supports in immunocolumns for allergen detection enables fast and sensitive screening of allergens in foodstuffs with sample throughput of up to eight samples per hour.  相似文献   

18.
The purpose of this study was the development and validation of an LC–MS–MS method for simultaneous analysis of ibuprofen (IBP), 2-hydroxyibuprofen (2-OH-IBP) enantiomers, and carboxyibuprofen (COOH-IBP) stereoisomers in fungi culture medium, to investigate the ability of some endophytic fungi to biotransform the chiral drug IBP into its metabolites. Resolution of IBP and the stereoisomers of its main metabolites was achieved by use of a Chiralpak AS-H column (150 × 4.6 mm, 5 μm particle size), column temperature 8 °C, and the mobile phase hexane–isopropanol–trifluoroacetic acid (95: 5: 0.1, v/v) at a flow rate of 1.2 mL min−1. Post-column infusion with 10 mmol L−1 ammonium acetate in methanol at a flow rate of 0.3 mL min−1 was performed to enhance MS detection (positive electrospray ionization). Liquid–liquid extraction was used for sample preparation with hexane–ethyl acetate (1:1, v/v) as extraction solvent. Linearity was obtained in the range 0.1–20 μg mL−1 for IBP, 0.05–7.5 μg mL−1 for each 2-OH-IBP enantiomer, and 0.025–5.0 μg mL−1 for each COOH-IBP stereoisomer (r ≥ 0.99). The coefficients of variation and relative errors obtained in precision and accuracy studies (within-day and between-day) were below 15%. The stability studies showed that the samples were stable (p > 0.05) during freeze and thaw cycles, short-term exposure to room temperature, storage at −20 °C, and biotransformation conditions. Among the six fungi studied, only the strains Nigrospora sphaerica (SS67) and Chaetomium globosum (VR10) biotransformed IBP enantioselectively, with greater formation of the metabolite (+)-(S)-2-OH-IBP. Formation of the COOH-IBP stereoisomers, which involves hydroxylation at C3 and further oxidation to form the carboxyl group, was not observed.  相似文献   

19.
Nickel(II) and lead(II) ionic imprinted 8-hydroxyquinoline polymers were synthesized by a precipitation polymerization technique and were used as selective solid phase extraction supports for the determination of nickel and lead in seawater by flow injection solid phase extraction on-line inductively coupled plasma-optical emission spectrometry. An optimum loading flow rate of 2.25 mL min−1 for 2 min and an elution flow rate of 2.25 mL min−1 for 1 min gave an enrichment factor of 15 for nickel. However, a low dynamic capacity and/or rate for adsorption and desorption was found for lead ionic imprinted polymer and a flow rate of 3.00 mL min−1 for 4-min loading and a flow rate of 2.25 mL min−1 for 1-min elution gave a enrichment factor of 5. The limit of detection was 0.33 μg L−1 for nickel and 1.88 μg L−1 for lead, with a precision (n = 11) of 8% (2.37 μg Ni L−1) for nickel and 11% (8.38 μg Pb L−1) for lead. Accuracy was also assessed by analyzing SLEW-3 (estuarine water) and TM-24 (lake water) certified reference materials, and the values determined were in good agreement with the certified concentrations.  相似文献   

20.
The effect of substrate (glucose) concentration on the stability and yield of a continuous fermentative process that produces hydrogen was studied. Four anaerobic fluidized bed reactors (AFBRs) were operated with a hydraulic retention time (HRT) from 1 to 8 h and an influent glucose concentration from 2 to 25 g L−1. The reactors were inoculated with thermally pre-treated anaerobic sludge and operated at a temperature of 30 °C with an influent pH around 5.5 and an effluent pH of about 3.5. The AFBRs with a HRT of 2 h and a feed strength of 2, 4, and 10 g L−1 showed satisfactory H2 production performance, but the reactor fed with 25 g L−1 of glucose did not. The highest hydrogen yield value was obtained in the reactor with a glucose concentration of 2 g L−1 when it was operated at a HRT of 2 h. The maximum hydrogen production rate value was achieved in the reactor with a HRT of 1 h and a feed strength of 10 g L−1. The AFBRs operated with glucose concentrations of 2 and 4 g L−1 produced greater amounts of acetic and butyric acids, while AFBRs with higher glucose concentrations produced a greater amount of solvents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号