首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A liquid chromatographic/turbo ionspray tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of L-753,037, a potent endothelin receptor antagonist currently under development for the treatment of cardiovascular diseases, in human plasma. L-753,037 is extracted from 0.5 ml of human plasma using liquid-liquid extraction and analyzed by LC/MS/MS with a turbo ionspray interface. Method validation results showed that this method is very sensitive, reliable, selective and reproducible. L-753,048, an ethoxy analogue of L-753,037, was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 50 pg ml(-1) with a linear calibration range of 0.05-50 ng ml(-1). The intra-day precision and accuracy (n = 5) were measured to be below 10% relative standard deviation (RSD) and between 97.4 and 102.8% of the nominal values, respectively, for all calibration standard concentrations within the calibration curve range. The inter-day precision and accuracy (n = 3 days, 5 replicates per day) were measured to be below 6.5% RSD and between 99.3 and 102.0% of the nominal values, respectively, for all quality control concentrations. The extraction recovery was determined to be approximately 99% on average. The analyte was found to be stable in plasma through three freeze-thaw cycles, for at least 4 h at ambient temperature and for up to 40 days under -20 degrees C freezer storage conditions. The analyte was also shown to be stable for at least 24 h in the reconstitution solution at room temperature and for up to 3 days as a dried extract at 4 degrees C. Additional variations in plasma concentration of the analyte due to the use of different sources of plasma were also evaluated.  相似文献   

2.
The simultaneous purification and concentration of synthetic human beta-endorphin from plasma is described, which when used together with an appropriate isocratic high-performance liquid chromatographic-electrochemical detection (HPLC-ED) system allows the determination of elevated physiological levels of beta-endorphin. Purification of plasma was gained by flash-freezing in liquid nitrogen, acidifying with 100 microliters of trifluoroacetic acid (10%, v/v) per ml of plasma, thawing at 4 degrees C and centrifuging to remove any precipitate. Solid-phase extraction with silica sorbent was utilised, which allowed further isolation of the analyte, a method of concentration and a procedure whereby beta-endorphin could be transferred to the HPLC mobile phase. Silica sorbent demonstrated greater selectivity than C18 for synthetic human beta-endorphin and, in addition, provided improved recovery of this analyte when utilising elution volumes of 500 microliters or less. Proteolytic degradation and heparin-induced high-affinity binding in plasma were shown not to effect the recovery of beta-endorphin if blood was rapidly chilled and plasma quickly obtained, frozen and acidified. Validation of this purification/concentration method using [125I]beta-endorphin demonstrated a recovery of 85.6% which was not jeopardised when concentrating the sample twenty-fold. This provided an increase in the sensitivity of detection, when used in conjunction with HPLC-ED, from 5 ng/ml to 250 pg/ml.  相似文献   

3.
An improved high-performance liquid chromatographic method with UV detection at 313 nm has been developed for quantitation of ranitidine in 100 microliter of rat plasma over the range 25 to 1000 ng/ml. To each sample were added the internal standard (metiamide) and 2 M NaOH. After dichloromethane extraction, the nitrogen-dried extracts were reconstituted in the mobile phase of 0.01 M phosphate buffer-triethylamine-methanol-water (530:5:390:75 v/v). Chromatography on mu Bondapak C18 with quantitation by peak height ratios showed an analyte recovery of 97%; a limit of detection of 10 ng/ml; a precision of 1-10% and an accuracy of 1-5%. About 90 samples can be processed in 24 h.  相似文献   

4.
A sensitive and specific high-performance liquid chromatographic method has been developed to measure the catechol-O-methyl-transferase (COMT) inhibitor 3,4-dihydroxy-4'-methyl-5-nitrobenzophenone (Ro 40-7592) in human plasma. The compound and the internal standard were extracted from plasma at pH 2 with n-butyl chloride-ethyl acetate (95:5, v/v). The extract was chromatographed on a reversed-phase column (Hypersil ODS, 5 microns) using a mixture of phosphate buffer (0.05 M, pH 2), methanol and tetrahydrofuran (45:55:5, v/v/v) as the mobile phase. Long-retained components were removed from the system by means of a simple column-switching system. Quantification of the catechol-O-methyltransferase inhibitor was performed by means of coulometric detection (0.1 V). The limit of quantification was about 1 ng/ml, using a 1-ml specimen of plasma. The recovery from human plasma was greater than 88%. The mean inter-assay precision was 5.3% in the range 2.5-1000 ng/ml. Linearity of the standard curve was obtained in the concentration range 2.5-500 ng/ml. The catechol-O-methyltransferase inhibitor was stable in human plasma when stored for six months at -20 degrees C and for 24 h at room temperature. The practicability of the new method was demonstrated by the analysis of more than 400 plasma samples from a tolerance study performed in human volunteers.  相似文献   

5.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of both remacemide (a novel anticonvulsant and cerebroprotectant) and an active, major metabolite in human plasma. After the addition of an internal standard, the analytes were extracted from the plasma by ion-exchange solid-phase extraction and measured by an isocratic HPLC system with ultraviolet detection at 210 nm. The recovery of the analytes was > 90%. The standard curves were linear over the range of quantitation of approximately 10-500 ng/ml for remacemide itself and 15-250 ng/ml for the metabolite. Both intra-day and inter-day accuracy and precision data were excellent. Remacemide and its metabolite were shown to be stable in human plasma for at least a year when stored at -20 degrees C.  相似文献   

7.
A rapid, sensitive and specific method for quantifying clonazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a hexane/diethylether (20 : 80, v/v) solution. The extracts were analysed by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on a Jones Genesis C8 4 microm analytical column (100 x 2.1 mm i.d.). The method had a chromatographic run time of 3.0 min and a linear calibration curve over the range 0.5-50 ng/ml (r2 > 0.9965). The limit of quantification was 0.5 ng/ml. This HPLC/MS/MS procedure was used to assess the bioequivalence of two clonazepam 2 mg tablet formulations (clonazepam test formulation from Ranbaxy Laboratories Ltd and Rivotril from Roche Laboratórios Ltda as standard reference formulation).  相似文献   

8.
Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was used for the quantification of the neuromuscular blocking agent rocuronium in human plasma. Verapamil was used as internal standard. The samples were subjected to a dichloromethane liquid-liquid extraction after ion pairing of the positively charged ammonium compound with iodide prior to LC-MS. Optimized conditions involved separation on a Symmetry Shield RP-18 column (50 x 2.1 mm, 3.5 microm) using a 15-min gradient from 10 to 90% acetonitrile in water containing 0.1% trifluoroacetic acid at 250 microl/min. Linear detector responses for standards were observed from 25 to 2,000 ng/ml. The extraction recovery averaged 59% for rocuronium and 83% for the internal standard. The limit of quantification (LOQ), using 500 microl of plasma, was 25 ng/ml. Precision ranged from 1.3 to 19% (LOQ), and accuracy was between 92 and 112%. In plasma samples, at 20 and 4 degrees C, rocuronium was stable at physiological pH for 4 h; frozen at -30 degrees C it was stable for at least 75 days. The method was found suitable for the analysis of samples collected during pharmacokinetic investigations in humans.  相似文献   

9.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

10.
A rapid, simple, selective and specific high performance liquid chromatography (HPLC) method with UV detection (230 nm) was developed and validated for estimation of guaifenesin from spiked human plasma. The analyte and internal standard (eplerenone) were extracted with dichloromethane. The chromatographic separation was performed on HiQSil C 18HS column (250 × 4.6 mm, 5 μm) with a mobile phase of methanol: water (60: 40%, v/v) at a flow rate of 1 mL/min. Guaifenesin was well resolved from plasma constituents and internal standard. The calibration curve was linear in the range of 100–3200 ng/mL. The heteroscedasticity was minimized by using weighted least square regression with weighing factor of 1/x. The intra- and inter-day % RSD was less than 15. Results of recovery studies prove the extraction efficiency. Stability data indicated that guaifenesin was stable in plasma after three freeze thaw cycles and upon storage at ?20°C for 30 days.  相似文献   

11.
Huperzine A is a potent, reversible acetylcholinesterase inhibitor. In the present work, a rapid and sensitive LC-MS-MS method for the determination of huperzine A in human plasma using codeine phosphate as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using ethyl acetate, chromatographed on a C(18) column (5 microm, 150 x 4.6 mm i.d.) with a mobile phase consisting of 1% formic acid-methanol (40:60, v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. Good linearity was achieved in the range 0.126 -25.2 ng/mL and the limit of detection in plasma was 0.064 ng/mL. The average recovery for huperzine A was 83.4% from plasma. The analytical sensitivity and accuracy of this assay is adequate for characterization of huperzine A in human plasma.  相似文献   

12.
A rapid, simple and specific method for estimation of anastrazole in human plasma was validated using letrozole as internal standard. The analyte and internal standard were extracted from plasma using simple solid‐phase extraction. The compound were separated on a reverse‐phase column with an isocratic mobile phase consisting of 0.1% formic acid in water and acetonitrile (12 : 88, v/v) and detected by tandem mass spectrometry in positive ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 294.1 → 225.1 for anastrazole and m/z 286.1 → 217.1 for internal standard. Linearity in plasma was observed over the concentration range 0.3–30 ng/mL for anastrazole. The mean recovery for anastrazole was 83.7% with a lower limit of quantification of 0.3 ng/mL. The coefficient of variation of the assay was less than 6.8% and the accuracy was 96.1–102.2%. The validated method was applied to a bioequivalence study of 1 mg anastrazole tablet in healthy human volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) and chromatographed on a column packed with Spherosil XOA 600 (5 micrometers) using a 7:3 (v/v) mixture of diisopropyl either--isooctane (1:1, v/v + 0.2% triethylamine and diisopropyl ether--methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. less than 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

14.
A highly sensitive liquid chromatographic-tandem mass spectrometric method (LC-MS-MS) is developed to quantitate ranolazine in human plasma. The analyte and internal standard tramadol are extracted from plasma by liquid-liquid extraction using diethyl ether-dichloromethane (60:40 v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (60:40 v/v, pH 4.0) at a flow of 1.0 mL/min. Detection is carried out by multiple reaction monitoring on a QtrapTM LC-MS-MS system with an electrospray ionization interface. The assay is linear over the range 10-5000 ng/mL with a limit of quantitation of 10 ng/mL and a lower limit of detection (S/N > 3) of 1 ng/mL. Intra- and inter-day precision are < 3.1% and < 2.8%, respectively, and the accuracy is in the range 96.7-101.6%. The validated method is successfully used to analyze the drug in samples of human plasma for pharmacokinetic studies.  相似文献   

15.
A high-performance liquid chromatographic method was developed for the simultaneous determination of haloperidol and reduced haloperidol in human plasma, urine and rat tissue homogenates using bromperidol as an internal standard. The method involved extraction followed by injection of 50-80 microliters of the aqueous layer onto a C18 reversed-phase column. The mobile phase was 0.5 M phosphate buffer-acetonitrile-methanol (58:31:11, v/v/v) and the flow-rate was 0.6 ml/min. The column effluent was monitored by ultraviolet detection at 214 nm. The retention times for reduced haloperidol, haloperidol and bromperidol were 5.4, 7.2 and 8.4 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.5 ng/ml, and the corresponding values in human urine were both 5 ng/ml. The coefficients of variation of the assay were generally low (below 10.7%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or any drug tested were found.  相似文献   

16.
Abstract

A rapid method for the simultaneous quantitation of the H2-receptor antagonist drugs cimetidine and ranitidine in human plasma by isocratic ion-pair reverse-phase HPLC is described. The method involves a simple organic extraction step of the alkalinized plasma containing added internal standard followed by back extraction of the extract with dilute acetic acid and subsequent analysis of the aqueous acidic phase on a reverse-phase (C18) column. The eluting solvent was acetonitrile-water (20:80 v/v) containing 0.005 mole/litre octanesulphonic acid and was monitored at 229 nm. The run time for the assay was 12.5 minutes, with a detection limit for cimetidine of 50 ng/m1/(0.2 μmole/1) and that for ranitidine was 20 ng/ml (0.06 umole/1).  相似文献   

17.
An improved assay for the determination of rofecoxib in human plasma samples is described. The analyte and an internal standard were extracted from the plasma matrix using solid-phase extraction in the 96-well format with an Empore C8-SD extraction plate. The analytes are chromatographed on a Waters Symmetry C18 analytical column (3.5 microm, 50x4.6 mm) with a mobile phase consisting of acetonitrile-water (35:65, v/v). Analyte detection was via fluorescence following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 0.5-80 ng/ml yielded a linear response when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day assay precision was better than 8% RSD at all points on the calibration curve, within-day accuracy was within 6% of nominal at all standard concentrations. The between-run precision and accuracy of the assay, as calculated from the results of the analysis of quality control samples, was better than 7% RSD and within 5% of nominal. Assay throughput was improved by a factor of three as compared to previously described methods. The method was partially automated using a combination of a Packard Multi-Probe liquid handling system and a TomTec Quadra 96 workstation.  相似文献   

18.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin.  相似文献   

19.
A sensitive, enantioselective, high-performance liquid chromatographic (HPLC) method was developed and validated to determine S-(-)- and R-(+)-bisoprolol in human plasma. Baseline resolution was achieved using the teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100 : 0.02 : 0.025, v/v/v) at a flow rate of 1.5 ml/min and fluorescence detection set at 275 nm for excitation and 305 nm for emission. All analyses with S-(-)-atenolol as the internal standard were conducted at ambient temperature. The assay involved the use of a solid-phase extraction procedure for human plasma samples prior to HPLC analysis. The C18 cartridge gave good recovery rates for both enantiomers without any interference. The method was validated over the range of 20-200 ng/ml for each enantiomer concentration. Recovery rates for S-(-)- and R-(+)-bisoprolol enantiomers were in the range of 95-102%. The method proved to be precise (within-run precision expressed as % RSD ranged from 1.0-6.2% and between-run precision ranged from 0.9-6.7%) and accurate (within-run accuracies expressed as percentage error ranged from 0.2-4.8% and between-run accuracies ranged from 0.3-1.7%). The limit of quantitation and limit of detection for each enantiomer in human plasma were 20 and 5 ng/ml, respectively.  相似文献   

20.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号