首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sol–gel coating technique was applied for the preparation of a solid‐phase microextraction fiber by coating the metal–organic framework UiO‐67 onto a stainless‐steel wire. The prepared fiber was explored for the headspace solid‐phase microextraction of five nitrobenzene compounds from water samples before gas chromatography with mass spectrometric detection. The effects of the extraction temperature, extraction time, sample solution volume, salt addition, and desorption conditions on the extraction efficiency were optimized. Under the optimal conditions, the linearity was observed in the range of 0.015–12.0 μg/L for the compounds in water samples, with the correlation coefficients (r) of 0.9945–0.9987. The limits of detection of the method were 5.0–10.0 ng/L, and the recoveries of the analytes from spiked water samples for the method were in the range of 74.0–102.0%. The precision for the measurements, expressed as the relative standard deviation, was less than 11.9%.  相似文献   

2.
In the present work, for the first time, an all‐in‐one solid‐phase microextraction technique was developed for the simultaneous and efficient extraction of analytes within a vast polarity range. A novel fiber assembly composed of two different steel components each coated with different coatings (polydimethylsiloxane and polyethylene glycol) in terms of polarity by sol–gel technology was employed for the extraction of model compounds of different polarity in a single run followed by gas chromatography with mass spectrometry. Effective parameters in the extraction step and gas chromatography with mass spectrometry analysis were optimized for all model compounds. The detection limits of the developed method for model compounds were below 0.2 ng/L. The repeatability and reproducibility of the proposed method, explained by relative standard deviation, varied between 7.22 and 9.15% and between 7.95 and 14.90 (n = 5), respectively. Results showed that, under random conditions, compared to separate extractions performed by two other differently end‐coated components that had not been assembled as the final dual fiber, as two individual fibers; simultaneous, efficient and relatively selective extraction of all model compounds was obtained in a single run by the proposed all‐in‐one technique. Finally, the optimized procedure was applied to extraction and determination of the model compounds in spiked water samples.  相似文献   

3.
We have synthesized an organic–inorganic polyaniline–halloysite nanotube composite by an in situ polymerization method. This nanocomposite is immobilized on a stainless‐steel wire and can be used as a fiber coating for solid‐phase microextraction. It was found that our new solid‐phase microextraction fiber is an excellent adsorbent for the extraction of some volatile organic compounds in aqueous samples in combination with gas chromatography and mass spectrometry. The coating can be prepared easily, is mechanically stable, and exhibits relatively high thermal stability. It is capable of extracting phenolic compounds from water samples. Following thermal desorption, the phenols were quantified by gas chromatography with mass spectrometry. The effects of extraction temperature, extraction time, sample ionic strength, stirring rate, pH, desorption temperature and desorption time were studied. Under optimal conditions, the repeatability for one fiber (n = 5), expressed as the relative standard deviation, is between 6.2 and 9.1%. The detection limits range from 0.005 to 4 ng/mL. The method offers the advantage of being simple to use, with a shorter analysis time, lower cost of equipment and higher thermal stability of the fiber in comparison to conventional methods of analysis.  相似文献   

4.
In this study, organic aerogels were synthesized by the sol–gel polycondensation of mixed cresol with formaldehyde in a slightly basic aqueous solution. Carbon aerogels and xerogels are generated by pyrolysis of organic aerogels. The novel sol–gel‐based micro‐solid‐phase extraction sorbent, resorcinol–formaldehyde xerogel, was employed for preconcentration of some selected herbicides. Three herbicides of the aryloxyphenoxypropionate group, clodinafop‐propargyl, haloxyfop‐etotyl, and fenoxaprop‐P‐ethyl, were extracted from aqueous samples by micro‐solid‐phase extraction and subsequently determined by gas chromatography with mass spectrometry. The effect of different parameters influencing the extraction efficiency of these herbicides including sample flow rate, sample volume, and extraction time were investigated and optimized. Under optimum conditions, linear calibration curves in the range of 0.10–500 ng/L with R2 > 0.99 were obtained. The relative standard deviation at 50 μg/L concentration level was lower than 10% (n = 5) and detection limits were between 0.05 and 0.20 μg/L. The proposed method was successfully applied to the sampling and extraction of herbicides from Zayanderood and paddy water samples.  相似文献   

5.
A mesoporous carbon was fabricated using MCM‐41 as a template and sucrose as a carbon source. The carbon material was coated on stainless‐steel wires by using the sol–gel technique. The prepared solid‐phase microextraction fiber was used for the extraction of five volatile aromatic compounds (chlorobenzene, ethylbenzene, o‐xylene, bromobenzene, and 4‐chlorotoluene) from tea beverage samples (red tea and green tea) prior to gas chromatography with mass spectrometric detection. The main experimental parameters affecting the extraction of the volatile aromatic compounds by the fiber, including the extraction time, sample volume, extraction temperature, salt addition, and desorption conditions, were investigated. The linearity was observed in the range from 0.1 to 10.0 μg/L with the correlation coefficients (r) ranging from 0.9923 to 0.9982 and the limits of detection were less than 10.0 ng/L. The recoveries of the volatile aromatic compounds by the method from tea beverage samples at spiking levels of 1.0 and 10.0 μg/L ranged from 73.1 to 99.1%.  相似文献   

6.
A high‐performance metal oxide polymer magnetite/polyethylene glycol nanocomposite was prepared and coated in situ on the surface of the optical fiber by sol–gel technology. The magnetite nanoparticles as nanofillers were synthesized by a coprecipitation method and bonded with polyethylene glycol as a polymer. The chemically bonded coating was evaluated for the headspace solid–phase microextraction of some environmentally important volatile organic compounds from aqueous samples in combination with gas chromatography and mass spectrometry. The prepared fiber was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The mass ratio of nanofiller and polymer on the coating extraction efficiency, morphology, and stability were investigated. The parameters affecting the extraction efficiency, including the extraction time and temperature, the ionic strength, desorption temperature, and time were optimized. The sol–gelized fiber showed excellent chemical stability and longer lifespan. It also exhibited high extraction efficiency compared to the two types of commercial fibers. For volatile organic compounds analysis, the new fiber showed low detection limits (0.008–0.063 ng/L) and wide linearity (0.001–450 × 104 ng/L) under the optimized conditions. The repeatability (interday and intraday) and reproducibility were 4.13–10.08 and 5.98–11.61%, and 7.35–14.79%, respectively (n = 5). For real sample analysis, three types of water samples (ground, surface, and tap water) were studied.  相似文献   

7.
A fast gas chromatography/mass spectrometry method was developed and validated for the analysis of the potential endocrine disrupters octinoxate and oxybenzone in swimming pool water samples based on the solvent‐free solid‐phase microextraction technique. The low‐pressure gas chromatography/mass spectrometry method used for the fast identification of UV filter substances was compared to a conventional method in terms of sensitivity and speed. The fast method proposed resulted in 2 min runs, leading to an eightfold decrease in the total analysis time and a sevenfold improvement in detection limits. The main parameters affecting the solid‐phase microextraction process were also studied in detail and the optimized conditions were as follows: fiber coating, polyacrylate; extraction mode, direct immersion; extraction temperature, 25°C; sample volume, 5 mL; extraction time 45 min; pH 6.5. Under the optimized conditions, a linear response was obtained in the concentration range of 0.5–25 μg/L with correlation coefficients in the range 0.990–0.999. The limits of detection were 0.17–0.29 μg/L, and the recoveries were 80–83%. Combined method uncertainty was assessed and found to be less than 7% for both analytes for concentrations equal to or higher than 5 μg/L. Pool water samples were analyzed to demonstrate the applicability of the proposed method. Neither octinoxate nor oxybenzone were detected in the swimming pool water samples at concentrations above the respective limits of detection.  相似文献   

8.
The inclusion of a polyamidoamine dendrimer in a silica sol–gel yielded a solid nanosorbent that was used for the preconcentration, extraction, and determination of citalopram in hospital waste water, hemodialysis solution, and some drinking water. The method was developed by applying a novel nanosorbent for the solid‐phase microextraction of citalopram, containing a silica sol–gel reinforced by polyamidoamine second‐generation dendrimer, which was protected by a polypropylene hollow fiber. Plackett–Burman design and central composite design were utilized to evaluate the significance of several factors on the extraction efficiency. The adsorption mechanism and thermodynamic and kinetic aspects were studied. The adsorption process was exothermic and well fitted to the Bangham equation kinetic model. Under optimal conditions, the presented method was liner in the range of 0.05–100 μg/mL. The limits of detection of quantification of citalopram were 0.0095 and 0.031 μg m/L, respectively.  相似文献   

9.
A method based on direct immersion solid‐phase microextraction (DI‐SPME) coupled with high performance liquid chromatography combined with post‐column photochemically induced fluorimetry derivatization and fluorescence detection (HPLC‐PIF‐FD) was developed to extract three pyrethroid insecticides, i.e. cyfluthrin, cypermethrin, and flumethrin from water samples. A sol‐gel based coating fiber using 3‐(trimethoxysilyl propyl) amine as precursor was prepared and used for the extraction of the pyrethroids from groundwater samples. A post‐column photochemical reactor was designed and constructed for the derivatization of these environmentally important pollutants to increase their fluorescence sensitivity and determination in HPLC. The parameters affecting extraction process (extraction time and temperature, pH, salt addition, and co‐solvent) and desorption step (solvent, desorption time, and temperature) of the analytes from the sol‐gel‐based fiber, along with photochemical reaction conditions were investigated. The developed method proved to be relatively rapid, simple, and easy and offers high sensitivity and reproducibility. Linear dynamic ranges (LDR) for these insecticides were ranged between 0.25 to 50 μg/L. The regression coefficients were satisfactory (R2 > 0.984) for these pyrethroids. The limits of detection and limits of quantification varied between 0.09 and 0.35 μg/L and 0.25 and 1.00 μg/L, respectively. Relative standard deviation RSDs values varied between 4.41% and 6.20%. Relative recoveries obtained from analysis of Jajroud river water sample ranged between 94% and 104%.  相似文献   

10.
A new sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was prepared as sorbent for solid‐phase extraction. The extraction efficiency of the prepared sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography–mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method showed good linearity range (0.05‐1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01–0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3–6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33–120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3–100.2%) and relative standard deviations (6.3–8.8%). The solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.  相似文献   

11.
In this study, a novel technique is proposed for preparation of an efficient and unbreakable metal‐wire‐supported solid‐phase microextraction fiber. A sol–gel film was deposited on electrophoretically deposited carbon nanotubes on a stainless‐steel wire. The applicability of the fiber was evaluated through the extraction of some aromatic pollutants as model compounds from the headspace of aqueous samples in combination with gas chromatography and mass spectrometry. The parameters affecting the structure and extraction efficiency of the fiber (including the type of solvent, time, and potential for electrophoretic deposition) and the parameters affecting the extraction efficiency (such as coating type, salt content, extraction temperature, and time) were investigated. The results showed that the film thickness will be increased by increasing the potential and time duration. Finally, the characterization of the deposited film was accomplished by scanning electron microscopy and thermogravimetric analysis. After the optimization of the extraction parameters, the limit of detection of less than 20 pg/mL was achieved, and the calibration curves were all linear (r 2 ≥ 0.9737), in the range from 50 to 500 pg/mL. The solid‐phase microextraction fiber has a high mechanical strength; good stability and long service life, making it potentially applicable in the extraction of trace polycyclic aromatic hydrocarbons from aqueous samples.  相似文献   

12.
We report the electrochemical fabrication of a poly(2,2‐bithiophene‐co‐3‐methylthiophene)‐graphene composite coating and its application in the headspace solid‐phase microextraction and gas chromatography determination of benzenes (i.e., bromobenzene, 4‐bromotoluene, 2‐nitrotoluene, 3‐nitrotoluene and 1,2,4‐trichlorobenzene). The coating was uniform and showed cauliflower‐like microstructure. It had high thermal stability (up to 375°C) and could be used for at least 180 times of solid‐phase microextraction without a decrease in extraction performance. Furthermore, it presented high extraction capacity for the benzenes due to the hydrophobic effect and π–π interaction between the analytes and the coating. Under optimized extraction conditions, good linearity (correlation coefficients higher than 0.9946), wide linear range (0.01–50 μg/L), and low limits of detection (5.25–12.5 ng/L) were achieved for these analytes. The relative standard deviation was lower than 5.7% for five successive measurements with one fiber, and the relative standard deviation for fiber‐to‐fiber was 4.9–6.8% (n = 5). The solid‐phase microextraction and gas chromatography method was successfully applied for the determination of three real samples, and the recoveries for standards added were 89.6–106% for nail polish, 85.8–110% for hair dye, and 90–106.2% for correction fluid, respectively.  相似文献   

13.
A novel solid phase microextraction fiber was prepared for the first time by using a sol–gel technique with hydroxypropyl‐β‐cyclodextrin‐functionalized reduced graphene oxide as the fiber coating material. The results verified that the β‐cyclodextrin was successfully grafted onto the surface of reduced graphene oxide and the coating possessed a uniform folded and wrinkled structure. The performance of the solid phase microextraction fiber was evaluated by using it to extract nine volatile aromatic compounds from water samples before determination with gas chromatography and flame ionization detection. Some important experimental parameters that could affect the extraction efficiency such as the extraction time, extraction temperature, desorption temperature, desorption time, the volume of water sample solution, stirring rate, as well as ionic strength were optimized. The new method was validated to be effective for the trace analysis of some volatile aromatic compounds, with the limits of detection ranging from 2.0 to 8.0 ng/L. Single fiber repeatability and fiber‐to‐fiber reproducibility were in the range of 2.5–9.4 and 5.4–12.9%, respectively. The developed method was successfully applied to the analysis of three different water samples, and the recoveries of the method were in the range from 77.9 to 113.6% at spiking levels of 10, 100, and 1000 ng/L, respectively.  相似文献   

14.
Through the use of a homemade sol–gel‐derived fiber, a headspace solid‐phase microextraction technique coupled to gas chromatography with mass spectrometry was developed for the determination of fatty acids with long, even‐numbered carbon chains (C12–C24) in soil samples. The experimental parameters such as reaction time, temperature, and ionic strength that might affect derivatization, extraction, and desorption were investigated. Under the optimized conditions, the linearity of the method ranged from 0.1 to 100 mg/L with a correlation coefficient >0.997. The limit of detection values based on a signal‐to‐noise ratio of 3:1 were determined with the concentration from 0.39 to 39.4 μg/L. The recoveries of the method for the soil samples were from 91.15 to 108.1%. This developed method using a homemade fiber showed a higher sensitivity than that using a commercial polydimethylsiloxane fiber and was also for the analysis of real soil samples from the Paomaling geological park of China.  相似文献   

15.
In this work, a graphene composite was coated onto etched stainless‐steel wire through a sol–gel technique and it was used as a solid‐phase microextraction (SPME) fiber. The prepared fiber was characterized by SEM, which revealed that the fiber had a highly porous structure. The application of the fiber was evaluated through the headspace SPME of five halogenated aromatic hydrocarbons (chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, 1,2‐dichlorobenzene, and 1,2,4‐trichlorobenzene) in water samples followed by GC with flame ionization detection. The main factors influencing the extraction efficiency, including headspace volume, extraction time, extraction temperature, stirring rate, ionic strength of sample solution, and desorption conditions, were studied and optimized. Under the optimum conditions, the linearity of the method ranged from 2.5 to 800.0 μg/L for 1,2,4‐trichlorobenzene and from 2.5 to 500.0 μg/L for chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, and 1,2‐dichlorobenzene, with the correlation coefficients (r) ranging from 0.9962 to 0.9980, respectively. The LODs (S/N = 3) of the method for the analytes were in the range between 0.5 and 1.0 μg/L. The recoveries of the method for the analytes obtained for the spiked water samples at 50.0 and 250.0 μg/L were from 76.0 to 104.0%.  相似文献   

16.
To prevent the stripping of coating sorbents in headspace solid‐phase microextraction, a porous extraction probe with packed sorbent was introduced by using a porous stainless steel needle tube and homemade sol–gel sorbents. The traditional stainless‐steel needle tube was punched by a laser to obtain two rows of holes, which supply a passageway for analyte vapor during extraction and desorption. The sorbent was prepared by a traditional sol–gel method with both poly(ethylene glycol) and hydroxy‐terminated silicone oil as coating ingredients. Eight polycyclic aromatic hydrocarbons and six benzene series compounds were used as illustrative semi‐volatile and volatile organic compounds in sequence to verify the extraction performance of this porous headspace solid‐phase microextraction probe. It was found that the analysis method combining a headspace solid‐phase microextraction probe and gas chromatography with mass spectrometry yielded determination coefficients of no less than 0.985 and relative standard deviations of 4.3–12.4%. The porous headspace solid‐phase microextraction probe showed no decrease of extraction ability after 200 uses. These results demonstrate that the packed extraction probe with porous structure can be used for headspace solid‐phase microextraction. This novel design may overcome both the stripping and breakage problems of the conventional coating fiber.  相似文献   

17.
In this research, the headspace solid‐phase microextraction (SPME) coupled with GC flame ionization detector was applied for the determination of some monocyclic aromatic amines in real water and urine samples. A sol–gel technique was applied for the preparation of the SPME fibers. Two different sol–gel coatings, (PEG and poly(ethylene glycol) modified with multi‐walled carbon nanotubes [PEG/CNTs]), were prepared and compared. Extraction efficiency of PEG/CNTs was better than PEG fiber in the same conditions. To obtain maximum extraction efficiency, some parameters such as desorption temperature and time, temperature and time of extraction, salt effect, pH, and stirring speed were investigated and optimized for PEG/CNTs fiber. Under optimized conditions, the LODs (S/N = 3) were in the range of 0.5–50 ng/L and limits of quantification (S/N = 10) were between 1 and 500 ng/L. Repeatability (n = 5) was in the range of 3.2–9.1% and reproducibility (n = 3) was obtained from 5.5 to 12.0%. The method was successfully applied to the analysis of real water and urine samples with recoveries from 63.7 to 97.0%.  相似文献   

18.
A solution of polyamide (PA) containing polyethylene glycol (PEG) as a side low‐molecular‐weight polymer was electrospun. After synthesizing the PA–PEG nanofibers, the constituent was subsequently removed (modified PA) and confirmed by Fourier transform infrared spectroscopy. The scanning electron microscopy images showed an average diameter of 640 and 148 nm for PA and PA–PEG coatings, respectively, while the latter coating structure was more homogeneous and porous. The extraction efficiencies of PA, PA–PEG, and the modified PA fiber coatings were assayed by headspace solid‐phase microextraction of a number of chlorophenols from real water samples followed by their determination by gas chromatography with mass spectrometry. To prepare the most appropriate coatings, the amounts and the flow rate of the electrospinning solution were investigated. Various extraction parameters, such as the salt content, desorption condition, extraction temperature, and time were optimized. The limits of detection of the method were in the range of 0.8–25 ng/L, while the RSDs at two concentration levels of 200 and 80 ng/L were between 2.1 and 12.2%. The analysis of real water samples led to relative recoveries between 85 and 98% with a linearity of 8–1500 ng/L.  相似文献   

19.
A superhydrophobic polystyrene hollow fiber was electrospun around a copper spring collector. This approach led to the construction of a hollow fiber membrane, and the copper spring acted as a scaffold. The characteristic properties of the hollow fiber were studied by scanning electron microscopy. The membrane was used as a probe to transfer the extracting solvent from aquatic media to a gas chromatograph. After performing the liquid–liquid microextraction procedure on 10 mL of water sample by octanol, the whole solution was passed through the prepared polystyrene hollow fiber. Propanol, containing 2 mg/L lindane as the internal standard, was used for desorption and an aliquot of 2 μL of the desorbing solvent was subsequently injected into gas chromatography with mass spectrometry. Effects of different parameters influencing the extraction efficiency were optimized. The limits of detection and quantification were 2 and 6 ng/L, respectively. The relative standard deviations at a concentration level of 100 ng/L were between 2 and 6% (n = 3) while the method linearity ranged from 6 to 200 ng/L. Some real water samples were analyzed by the developed method and relative recoveries were in the range of 76–107%.  相似文献   

20.
A sensitive technique to determinate naproxen in hair samples was developed using hollow‐fiber micro‐solid‐phase combined with fluorescence spectrophotometry. The incorporation of multi‐walled carbon nanotubes modified with a Keggin polyoxometalate into a silica matrix prepared by the sol–gel method was reported. In this research, the Keggin carbon nanotubes /silica composite was used in the pores and lumen of a hollow fiber as the hollow‐fiber micro‐solid‐phase extraction device. The device was used for the microextraction of the analyte from hair and water samples under the optimized conditions. An orthogonal array experimental design with an OA24 (46) matrix was employed to optimize the conditions. The effect of six factors influencing the extraction efficiency was investigated: pH, salt, volume of donor and desorption phase, extraction and desorption time. The effect of each factor was estimated using individual contributions as response functions in the screening process. Analysis of variance was employed for estimating the main significant factors and their contributions in the extraction. Calibration curve plot displayed linearity over a range of 0.2–10 ng/mL with detection limits of 0.072 and 0.08 ng/mL for hair and aqueous samples, respectively. The relative recoveries in the hair and aqueous matrices ranged from 103–95%. The relative standard deviation for fiber‐to‐fiber repeatability was 3.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号